| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC Award of contract | |
| 2 | L2₹17.1 L+₹61,762.50 (3.75%)Rejected-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹19.4 L+₹3.0 L (18.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹22.1 L+₹5.6 L (34.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹22.6 L+₹6.2 L (37.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
9 Aug 2021, 6:00 pmClosed
GE NAGROTA
GE NAGROTA C/O 56 APO
REPAIR AND MAINTENANCE OF LT OH LINE, HT PANELS UNDER GROUND CABLE WITH OTHER CONNECTED ITEMS AT GE NAGROTA
2021_MES_456813_1
GEN-31/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
NAGROTA
Class D and above and category b(I)
8 documents required · 8 mandatory
₹500
GE NAGROTA
₹60,000
Yes
29 Sept 2021
3 Jul 2021
11 Aug 2021
3 Jul 2021
9 Aug 2021
18 Jul 2021
Amount
Excavation in trenches in any type of soil not exc 1.5m wide and n.exc 1.5m in depth for electric poles stay foundation and under ground electric power cables and getting out, complete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and directed.
Removing excavated surplus material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I 2009, complete all as specified and directed by Engr-in-Charge.
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Labour only for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ obtained from excavation, complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 240 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 185 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 150 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 120 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 95 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 70 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 50 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
Supply, laying, jointing and testing XLPE insulated PVC sheathed armoured under ground cable heavy duty with aluminium conductor LT 1100 V grade cross sectional area 35 Sqmm 3.5core including taking down old cable, complete all as specified and directed by Engineer-in-Charge
M&L cable jointing kit for 1.1 KV (Earthed) Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 to 50 Sqmm, complete all as specified and directed
M&L cable jointing kit for 1.1 KV (Earthed) Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 to 120 Sqmm, complete all as specified and directed
M&L cable jointing kit for 1.1 KV (Earthed) Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 150 to 180 Sqmm, complete all as specified and directed
M&L cable jointing kit for 1.1 KV (Earthed) Grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 240 to 300 Sqmm, complete all as specified and directed
Cleaning, preparing and painting with one coat of aluminium paint to steel tubular pole 9m long complete with cross arms, MS channels, angle iron, frame work, etc including numbering of pole with black enameled paint from stencil, complete all as specified and directed.
S&F aluminium strip of size 25 x 3 mm for earth continuity conductor or main earthing lead fixed to wall burried in gound fixed alongwith poles, complete all as specified and directed.
Dismantling of ACSR or AAC conductors of any size and set in site, complete all as specified and directed
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed , complete all as specified and directed.
Dismantling air break gang operated switches vertical/horizpntal mounted including insulators and operating mechanism any type and size complete all as specified and directed. Note: the item are not reuse in side and carrying to credit
S&F switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and continuous current rating upto 200 amp and volt 11 KV, complete all as specified and directed.
Lightning arrestor non liner resistor type comply with IS 3070 Part I 1985 for alternating current system multiple spark gap suitable for voltage grade 11000 volt discharge capacity 65 KA, complete all as specified and directed.
S&F GI strip of size 25 x 4 mm for earth continuity conductor or main earthing lead fixed to wall burried in gound fixed alongwith poles, complete all as specified and directed.
S & F danger notice plate of size 25cmx20cmx1.6mm thick, mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved , complete all as specified and directed.
M&L Stay assembly galvanised iron complete with accessories stay rod 18mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed.
Cutting wild grasses,bushes,creepers,unwanted vegtation etc from four poles/ two pole Structure ,poles/stays including cleaning cripper climbed on poles asand when directed and removing the spoil and deposit where directed(size of cutting 2mx2m around the structure) entier satisfaction of Engineer-in-Charge complete all as specified and directed.Note:- The item shall be operated maximum three times in the entire period of the contract.
Supply and fixing in replacement of MCCB 630 Amps four pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 400 Amps four pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 320 Amps four pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 250 Amps four pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 200 Amps four pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 100 Amps three pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCCB 63 Amps three pole 415 Volts with breaking capacity 36 KA alongwith adjustable thermal and adjustable magnetic settings, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB TPN 32 Amps 415 Volts 50 Hz AC 10 KA "C" series with necessary lugs, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB TPN 63 Amps 415 Volts 50 Hz AC 10 KA "C" series with necessary lugs, complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB SPN 32 Amps 415 Volts 50 Hz AC 10 KA "C" series with necessary lugs , complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of MCB SPN 63 Amps 415 Volts 50 Hz AC 10 KA "C" series with necessary lugs , complete all as specified and directed by Engr-in-Charge.
S&F in replacement indicator lamp set (RYB), complete all as specified and directed.
Feeder piller box out door type ‘factory made’ made out from 16 SWG MS sheet supported with legs of 45cm long made of iron angle 25x25x4mm thick of size 75cm x60cm x45 cm with 04 Nos aluminium bus bar of 400 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement provn for incoming and outgoing cables with glands including painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge. Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 30 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mmdia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 1991 Part I connected to equipment, complete all as specified and testing on completion.
M&L for preparation of old painted steel surface by cleaning, removing rust, grease and apply one coat of synthetic enamel paint of approved shade (spray painting outside/inside surface) of the feeder pillar box/Lt panels outdoor/indoor type of approximate size 900 x 600 x 500 mm complete with prior permission of Engr-in-Charge. Base frame with balck enamel paint ( Rate quoted shall deem to be included of numbering of panel/feeder pillar) complete all as specified and directed
M&L for bakelite strip connector, 4 way, 100 Amp capacity including electricaly connections including taking down old item complete all as specified and directed
S&F junction box made from FRP sheet 2.00 mm thick ready made of size 400x300x200mm fixed to pole/wall with MS clamp 25 x 5 mm and suitable size of nut, bolts and washers including taking down existing junction box, complete all as specified and directed
S&F in repair aluminium bus bar of required size shape length and making drilling for fixing in LT panel/feeder, pillar/change over switch etc including necessary addition /alteration to existing panel with welding cutting to steel structure and providing new steel items including taking down old item complete all as specified and directed
M&L for servicing of feeder pillar box/LT cubical panel , after dismantling the incoming and outgoing connections from MEEB/Bus bar and replacing the old burnt/over head unserviceable lugs, terminals, nuts, bolts, washer supporing indulator etc and checking ithe serviceability of MCB/MCCB earth continuity conductor and strip etc complete all as specified and directed. Note:(i) Spare parts such as terminals, lugs, nut bolts, insulators etc will be measured and paid under respective item in the schedule, (ii) labour for fixing charge of the spare parts deemed to be included in the rate quoted for the items.
Supply only 400 Sqmm aluminium lugs of any type/shape
Supply only 300 Sqmm aluminium lugs of any type/shape
Supply only 240 Sqmm aluminium lugs of any type/shape
Supply only 150 Sqmm aluminium lugs of any type/shape
Supply only 120 Sqmm aluminium lugs of any type/shape
Supply only 95 Sqmm aluminium lugs of any type/shape
Supply only 70 Sqmm aluminium lugs of any type/shape
Supply only 50 Sqmm aluminium lugs of any type/shape
Supply only 35 Sqmm aluminium lugs of any type/shape
Supply only 25 Sqmm aluminium lugs of any type/shape
Supply only 16 Sqmm aluminium lugs of any type/shape
Supply only GI nuts, bolts, screws, washsers of required sizes
Supply only min size 45x50mm dia bus bar insulators Epoxy type as required at site
S&F MCCB of capacity 125/160 Amp extension link four set complete all as specified and directed
S&F MCCB of capacity 250 Amp extension link four set complete all as specified and directed
S&F MCCB of capacity 400/630 Amp extension link four set complete all as specified and directed
S&F current transformer of rating from 100/5 to 400/5 CT ration in existing panel complete all as specifed and directed
Taking down rusted portion of sheet of feeder pillar boxes, damaged hinges etc and supply and fix new hinges heavy duty type, MS sheet patch work by cutting , welding and fabricating at site as required not exc 0.5 sqm painting with two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed
S&F locking arrangement with aldrop bolt set complete of size 225mm to existing feeder pillar box by welding including taking down old worn out locking arrangement complete all as specified and directed
S&F 20 mm stainless steel double compression cable glands complete all as specified and directed
All as per ser item No.73 here in above but size 25-40mm
All as per ser item No. 73 here in above but size 50-80mm
M & L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) as in foundation, filling and mass concrete, complete all as specified and directed.
M & L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping, band, bed plates and similar items including weathering slightly rounded or chamferred angles and throughting, complete all as specified and directed.
Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of Rs. 80,615.00 during AOC Note:- Tenderers shall not quote for this Schedule
MAMTA ENTERPRISES
J S ENGINEERS
ASHOKA ENGINEERS AND BUILDERS
M/S MANJIT SINGH AND SONS
R K BUILDERS
NEW INDIA TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .