Estt. For P.S to 01 no. 05 Hp Agri. Pump conn.SC Consumer at vill. Semrikhurd under Misrod D.c
2019_MKVVC_16914_1
DGM/STC/Tender/SCSDP/13795/01
Open Tender
Electrical Works
Turn-key
45 days
Dy. General Manager (STC) Dn. Chandbad Bhopal
Please refer Tender documents.
8 documents required · 8 mandatory
₹200
A.O.A.U. (O and M) Circle M.P.M.K.V.V.C.L. Bhopal
₹2,500
1 Feb 2021
18 Feb 2019
27 Feb 2019
18 Feb 2019
25 Feb 2019
18 Feb 2019
18 Feb 2019 - 20 Feb 2019
LT XLPE Arial Bunch Cable 3x25+1x16+1x25 sqmm with alumum alloy bare messenger
11 KV Composite Polymer Disc Insulators
11 KV Polymer Pin Insulators
11 KV Strain Hardware (T&C) type) fittings
11 KV Top clamp 65x65x6 mm angle type
11 KV V cross arm 65x65x6 mm angle type
Back Clamp for 140 kg PCC pole MS flat 50x6 mm
11 KV DO fuse unit polymer type
11 KV Polymer lightening arrestor gapless type
DC cross arms 8' Channel (100x50x6mm)
AB Cable hanging clamps/tension (Galvanised) as per enclosed drawing
Back filling of poles with boulders
Clamp for 140 kg PCC pole MS flat 50x6 mm1
Stay clamp 50x6 mm of MS flat for pcc pole 140 kg
Clamp for neutral for AB Cable
Concreting of stay (16mm/12 mm) @ 0.2 cmt. Per stay
Concreting of PCC Poles @ .30 cmt. Per pole for base padding for DP/T etc
Earthing coil of 115 turns of 50 mm dia and 2.5 mtr. Lead of 4.00 mm GI wire
GI wires 4.0 mm (8 SWG)1
Jointing sleeves suitable for Rabbit (55 sq.mm. Al. Eq.) AAAC conductor
MS Nuts and Bolts
Red oxide paint
Aluminium binding wire and type
Aluminium Paint
Anti Climbing Devices
Danger Boards enamelled 11 KV
Bimetalic clamp distribution transformers bushing
Bi-metallic clamps suitable for 12 mm dia stud and 80 sqmm AAAC
Piercing connector type-I for IP/3P (Main 16-50 sqmm tap-off 16-50 sqmm)
Piercing connector type-II for IP/3P (Main 16-50 sqmm tap-off 16-50 sqmm)
Stay wire 7/3.15 mm (7/10 SWG
Stay set complete without stay wire 16 mm (Painted)
Stone block/pre cast block for base pedding (450x450x75mm)
Suspension clamp for LT AB cable
Stay insulators 90x65 mm
Earthing set (DTR earthing) as per circular no. 1516 dated 17.03.08
DO mounting channel 75x40x6 mm
Three phase static energy meters 20-80 amps with L.S. & TOD facility with box
Trans. Mounting with belting with 50x50x6 mm angle with two cross fixing channel
Transformer mounting channel (100x50x6mm)
XLPE 1 core unarmoured 35 sqmm aluminium conductor 1100 volts
Bracing support angle of 65x65x6 mm for 4' (1.2 mtr.) centre DP
11 KV AB Switch polymer type 400 amp with complete fitting
Distribution box for 25 KVA transformer
LT Robust fuse unit
DC cross arms 4' Channel (100x50x6mm) Channel
MS strain plate 65x8mm 250 mm long
Spring loaded CP multi conn. Bus-bar in insulated box single phase 1 in 3 out
Tension clamps (dead end) with attachment
L&T Charges
SUBHASH MOHADKAR
POWERTECH ELECTRICALS
NAVEEN SAXENA CONTRACTOR
AMIT CONSTRUCTION
SUPER ELECTRICALS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .