AGE(I) Fatehgarh
AGE(I) MES Fatehgarh
REPAIR/MAINT OF LT EXTERNAL ELECTRIC SUPPLY SYSTEM AT FATEHGARH CANTT.
2021_MES_495219_3
AGE(I)/FAT/ET-49 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
180 days
AGE (I) Fatehgarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) Fatehgarh
₹20,000
Yes
30 Apr 2022
8 Mar 2022
28 Mar 2022
8 Mar 2022
26 Mar 2022
8 Mar 2022
60 days
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth and getting out soft /loose soil complete all as specified and as directed for laying of under ground cable, foundation of pole and stay etc. complete all as specified and as directed
Returning, filling in, including spreading, levelling, watering and well remmining in layers not exc 25 cm complete all as specified and as directed
Removing excavated material n.exc 50 m and depositing where directed at a level n. exc 1.5 m above the starting point all as directed.
M & L Sand cushioning for U/G cables in layers of 23 cm thick (8cm before laying the cable and 15cm thick after laying the cable) in trenches complete and all as specified and directed . ( Note : Punned down volume shall be measured )
Supply and lay burnt best quality locally available old size sub class 'B' bricks laid in trenches perpendicular to U/G cable for cable protection complete all as specified and as directed.
Laying only serviceable bricks obtained from the items specified here-in-before (i.e during taking out of under ground cable),laid flat dry, in trenches with width of the bricks laid to the axis of cable for protection of cable complete all as specified and as directed
Dismantling of overhead ACSR conductor of any size including removing of PG Clamps jumpering etc and kept in safe custody for reuse serviceable ACSR in the work & removing unserviceable conductor from site complete all as specified & as directed.
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting a side serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting a side serviceable insulators for reuse in the work & removing unserviceable insulator from site complete all as specified & as directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as reqd. and removing the same from site complete all as specified & as directed.
M & L for staining of Aluminium conductor steel reinforeced (ACSR) on over head LT electric line required sag and binding the conductor with insulator and jumper with aluminium binding wire conforming to IS:398 Part-II complete all as specifie and as directed.
M & L for refixing and restringing serviceable ACSR (any size) as recovered from dismantling on over head LT electric line required sag and binding the conductor with insulator and jumper with aluminium binding wire conforming to IS:398 Part-II complete all as specifie and as directed.
S&F of cross arms bracing, supports, clamps and back plate fabricated from structural steel section including nut bolts, washers, welding, bending, cold or hot, drilling hole for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint complete all as specifed and directed
S & F pin type insulator porcelain vitreous, white, brown or green including one galvanized mild steel spindle, two galvanized iron washer and one galvanized iron nut 100 mm height, 65 mm dia for 1100 volts grade complete all as directed.
..ditto as above but for fixing only old serviceable pin type insulator as obtained dismanlting …..ditto....
S & F shackle type porcelain vitreous white, brown or green insulator of size 75 mm height 90 mm dia including MS strips 31x3 mm washers, insulator bolts 12 mm dia & nuts suitable for working pressure 1100 volts grade all as directed.
..ditto as above , but fixing oly old serviceable shackle type insulator as obtained from dismantling …ditto….
S&F of stay assembly comprising of 7/3.15 mm galvanised stay strandard wire of required length fixed to pole with and including flat iron clamp ,bolts, nut and washer, galvanised 20mm dia, 400 mm long stay bow with 16 mm dia 1.80 m long stay rod with threaded ends, GI nut and washer, GI stay plate 230x230x6mm thick plate, two nos thimble, MS clamp made out of 50 x 6mm flat iron, loop insulator 65mm x 90mm dia, 16 mm porcelain complete all as specified and shown in electrical plate No 1 including excavation and earth work and PCC copping.
Cutting of tree branches touching LT overhead lines to maintain a clearance of 1.50 metre from the overhead line to near by trees complete all as directed. Note: The scop of work shall be repeated in three months.
Dismantling of old unserviceable PCC/steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation, earth work as reqd & removing the same from site complete all as specified and as directed.
Supply and errecting steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screw and specified type 410 SP -31 09 Mtr long) all as specified including the following:- (a) Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in deep for pole foundation & getting out in soft /loose soil, returning filling in the excavated of soil after fixing the pole in foundation ramming earth around in layer n. exe 25 cm thick and disposal of surplus soil to a distance n.exc 50 m. (b) M&L for providing PCC 1:4:8 type D2 (Using 40 mm graded stone aggregate) in foundation 450 mm x 450 mm cross section planting depth 1.5 m for concrete incasing the pole upto GL all as directed. (c) M&L for providing PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) for plinth block/Collar above GL 300 mm high and 450 mm dia all as directed and specified. (d) M&L for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block/concrete collar with two coat of aluminium paint over a coat of red oxide steel primer including preparation of surface including painting of 30cm wide black and Yellow bands 5 Nos with synthetic enamel paint in alternate layer upto the height of 1.5m abvoe plinth block complete. (e) M&L for writing letter or figures (Block, Roman, italic as indian) with thick synthetic enamel paint of apprised shade n. exc height in numbring of pole all as directed by EIC.
M&L for drilling / Boring holes horizontally under road without damaging the surface of road ( minimum 1.0 Metre below the road surface with the help of GI tubing not exc 80 mm bore(dia) for passing UG cable, complete all as specified and as directed. NOTE : - GI Pipe laid will be measured and paid separately under respective item
S & F of 80 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers all as specified.
S&F in replacement of 50 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified
S&F in replacement of 40 mm bore GI tubing light grade with all fittings laid across road, in trenches or across PCC drain, along electric pole or floor/wall for cable protection with suitable size of MS clamps and nut and botls/washers complete all as specified and directed.
Taking out unserviceable LT U/G cable of any size from any position i.e ground/ walls/ poles/ culverts etc complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 150 Sqmm 3.5 core complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 120 Sqmm 3.5 core complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 95 Sqmm 3.5 core complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 70 Sqmm 3.5 core complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified and directed.
Supply and lay in trenches or passing through pipe XLPE insulated armoured, heavy duty electric cable with aluminium conductor 1100 volts grade, cross-sectional area 6 Sqmm 2 core complete all as specified and directed.
Relaying of existing serviceable underground cable of size 70 Sqmm to 240 Sqmm 3.5 Core obtained from dismantling complete all as specified and as directed.
M & L for cable route indicator for 1100 Volts grade cable with 150 mm dia cast iron plate circular or rectangular in shape of minimum 8 mm thickness welded with 35x35x4 mm angle iron mast 0.5 mtr from the GL including PCC foundation 1:3:6 type C1 of size 30x30x45 cm and necessary earth work complete all as specified and directed.
Fabrication, supply, installation,commissioning and testing in replacement of outdoor type feeder pillar box floor mounted made out from 3.15 mm thick MS sheet ( CPRI type tested) with canopy type roof, over all size 0.75 x 0.60 x 0.30 m front operated, two part hinged doors with locking arrangement comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter with heat strinkable PVC sleeving having RYB-B colour code drilling holes for connection of incoming and outgoing cable, complete powder coated painting, testing and installation on PCC/brick foundation, connection of cable with suitable aluminium lugs all as specified and directed. ( Note :-MCCB will be measured and paid separately.)
Fabrication, supply, installation, commissioning and testing in replacement of out door type LT Feeder pillar box size 0.90 m x 0.75 m x 0.45 m in depth made out of 3.15mm thick CRCA sheet ( CPRI type tested) and MS structural section of 50 x50 x 6 mm comprising of copper bus bar suitable for 3 phase, 4 wire, 415 volts,50 Hz, AC supply mounted on suitable bus bar insulators, 200 Amps rating suitably drilled and tapped for bolts with openable two part front and rear shutter, hinged front and rear panels and locking arrangement, bottom plate provided with the requires numbers of cable entries / opening including cable glands and cable lugs with heat strinkable PVC sleeving having RYB-B colour code , powder coated painting complete embedded in PCC 1:3:6 type C-2 ( using 40 mm graded aggregate ) n. exc. 0.45 cum and provision of following accessories complete all as specified and as directed ( Note :-MCCB will be measured and paid separately.)
S & F MCCB 100 Amps, 4 pole, 415 volts, 50 Hz 25 KA breaking capacity with adjustable thermal magnetic release with spreader link on both sides
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized GI strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints including excavation and earth work, GI pipe light grade 40mm bore for protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 using 20mm graded stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1 using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm bore GI Pipe light grade for watering complete all as shown in electrical plate No 3 of SSR Part-I(2009) and connected to earth test point including testing complete all as specified and directed.
M & L MS clamp made out of 50x6 mm flat iron bending cold or hot,drilling holes for bolts , in any shape or size as indicated or directed and inclusive of one primer coat,one under coat and one finishing aluminium coat of paint complete all as specified and directed.
Disconnection and dismantling of existing 11 KV VCB from the foundation including removing from the Site and carrying from Rajput Sub Stn to Yadunath Sub Stn and Reinstall the 11 KV VCB at site in position as directed after repair connecting HV electrical connections, earthing connections and testing to entire satisfaction on load complete all asspecified and as directed.complete all asspecified and as directed.
Disconnection and dismantling of existing 11 KV OCB from the foundation including removing from the Site and carrying from Yadunath Sub Stn to Rajput Sub Stn and Reinstall the 11 KV OCB at site in position as directed after repair connecting HV electrical connections, earthing connections and testing to entire satisfaction on load complete all asspecified and as directed.
Supply, installation and fabrication in replacement of reflective information sign board, single sided of size 16 ft x 3 ft made out of 2 mm thick aluminium sheet , pasted with blue colour back ground reflective paper, digital printed white colour lettering including marking MES Logo symbols and all fixing arrangements like nuts , bolts & washer to fix the sign board on existing steel structure incl surface preparation of steel structure and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. ( MH DG SET INSTALLATION AT AGE(I) FATEHGARH)
Supply, installation and fabrication in replacement of reflective information sign board, single sided of size 16 ft x 3 ft made out of 2 mm thick aluminium sheet , pasted with blue colour back ground reflective paper, digital printed white colour lettering including marking MES Logo symbols and all fixing arrangements like nuts , bolts & washer to fix the sign board on existing steel structure incl surface preparation of steel structure and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. ( 50 KLD STP AT AGE(I) FATEHGARH)
Supply, installation and fabrication of steel structure made out of 02 nos 200 mm dia,3 metre long flanged MS tube and angle iron work to make the base frame for fixing reflective information sign board incl necessary foundation nuts & bolt , excavation and PCC 1:3:6 and surface preparation of steel structure and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed
Disconnection and dismantling of existing serviceable under ground cable of size 25 Sqmm to 70 Sqmm 3.5/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
Disconnection and dismantling of existing serviceable under ground cable of size 95 Sqmm to 240 Sqmm 3.5/4 core from LT Panel/FPB and taking out cable/cable loop from underground by excavtion of soft/loose soil and insertion of heat shrinkable PVC colour sleeves on cable cores and crimping of suitable size aluminium cable lugs as required and refixing the same in its original position complete all as specified and as directed.
M & L for preparation of old painted steel or iron surfaces of LT FPB of various size by scrapping with steel wire brush /scrapper emery paper etc and applying one coat of synthetic enameled siemens grey/exising colour( painting shall be done by spray machine) including welding the LT FPB door matching with the LT FPB complete all as specified and as directed.
M/S shree traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .