Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹30.6 LAdmitted-Finance | -15.51% | ₹30.6 L | L1 | Admitted-Finance |
| 2 | Rejected-Technical OPP ANAND TALKIES SITABULDI NAGPUR 440012 | NAGPUR | MAHARASHTRA | 440012 | - | - | - | Rejected-Technical DOCUMENT NOT SUBMITTED AS PER MTF. |
Tender Value
₹36.2 L
EMD Value
₹72,500
Closing Date
19 Jan 2026, 5:00 pmClosed
AGM (EM) FCI RO Mumbai
FCI REGIONAL OFFICE MUMBAI
Annual Maintenance Contract of Various Electrical / Mechanical Services at FSD Manmad, FSD Ankai and FSD Ahmednagar
2026_FCI_893390_1
02/10/EE/2025-26
Open Tender
Electrical Works
365 days
FCI FSD MANMAD, FSD ANKAI AND FSD Ahmednagar
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹72,500
30 Jan 2026
10 Jan 2026
20 Jan 2026
10 Jan 2026
19 Jan 2026
10 Jan 2026
AT FSD Manmad, FSD Ankai Repairs & maintenance of the following Elect/Mech installation according to the terms & condition as per IE rule 1.Plug point/Power point 2. fans,E.I.,street light/compound lighting 3. water supply 4.LT panel maint. Further to provide insulation tape and Tools and Plant as per the site requirement. (Staff Required) Wireman Gr I - 04 Nos on all working Days & 03 Nos on all S / Saturday, Sunday & Holidays Khallasi - 04 Nos on all working Days & 02 Nos on all S / Saturday, Sunday & Holidays
AT FSD Ahmednagar Repairs & maintenance of the following Elect/Mech installation according to the terms & condition as per IE rule 1.Plug point/Power point 2. fans,E.I.,street light/compound lighting 3. water supply 4.LT panel maint. Further to provide insulation tape and Tools and Plant as per the site requirement. (Staff Required) Wireman Gr I - 01 Nos On Two Days Per Week Khallasi - 01 Nos On Two Days Per Week
Supply of 40W LED Lamp. Input voltage range 140-310 V AC alongwith holder etc. as required. Power consumption: 40W, Cool Daylight (6500-7500K) Light Colour: White, Lumen Output>=100 Lumens/Watt with 2 years manufacturing warranty.
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range-5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. complete in all respect etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Rewinding of open well submersible pump motor of all types and make upto and including 5 HP with coated copper wires and overhauling with minor repairs,etc., testing for the original speed H.P. and no load consumption & guarantee for one year.
Replacement the existing Impellar of approved make for pump 5 HP of all types with due alignment of the shaft and tested.
Replacement the existing Bush and Bearing of approved make for pump 5 HP of all types with due alignment of the shaft and tested.
Rewinding of mono block pump motor of all types and make upto and including 3 HP with coated copper wires and overhauling with minor repairs etc., testing for the original speed H.P. and no load consumption & guarantee for one year.
Replacement the existing Impellar of approved make for pump 3 HP of all types with due alignment of the shaft and tested
Replacement the existing Bush / Bearing of approved make for pump 3 HP of all types with due alignment of the shaft and tested.
Rewinding the motor of the table / pedstal / ceiling / exhaust fan of all type and make and over hauling including minor repairs and testing of original speed and consumption with gaurantee for one year along with Replacing the existing Ball Bearing & Bushing of complete with alignment of shaft and testing with replacement of Capacitor.
Supply of 1200 mm sweep ceiling fan capacitor type with double ball bearing suitable for single phase AC, 230V 50HZ Confirming to IS 374 / 1979 with upto date amendment.
Supplying of 5 A to 32 A rating 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles etc.as required.(As per IS/IEC 60898-1)
Single pole (32 A)
Double pole (32 A)
Triple pole and neutral or FP (32 A)
Supplying of following size of FRLS PVC insulated copper conductor, single core cable as required (ISI Certified)
Supplying of following piano type switch / socket as required.
3 / 5 pin 5 / 6 amp socket outlet ISI Marked
5/6 A one way Switch ISI Marked
6 pin 15/16 amp socket outlet ISI Marked
15/16 amps one way Switch ISI Marked
Supply of Stepped type Modular Fan regulator (2 module)
Supplying of following Modular type switch / socket as required.
3 / 5 pin 5 / 6 amp Modular socket outlet ISI Marked
5/6 A one way Modular Switch ISI Marked
Repairing of 250 kVA transformer and oil leakage arresting including replacement of gaskets, rubber packing, silica gel, HT/LT bushing repairing, oil filtration and BDV testing with report
Servicing and testing of 3 Nos of 11 kV HT VCB including cleaning, tightening, lubrication, inspection of vacuum interrupters, functional and operational testing, along with supplying and fixing of spare parts: 11 kV PT Fuse (9 Nos.), 3 OC + 1 EF Relay (3 Nos.), Multifunction Meter (2 Nos.), Power Pack (1 No.), Space Heater (6 Nos.), and Thermostat (3 Nos.)
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.28 MB
MTF.pdf
Tender Documents • 1.32 MB
BOQ_939034.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid