| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹43.7 L+₹69,485 (1.62%)Rejected-Finance OPP MARUTI SERVICE CENTRE SARACHARMA POST SRI VIJAYA PURAM 744 105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹44.4 L+₹1.4 L (3.36%)Rejected-Finance GURUDWARA LANE PORT BLAIR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹44.6 L+₹1.6 L (3.72%)Rejected-Finance GROUND FLOOR HOTEL SHALIMAR DELANJPUR SRI VIJAYA PURAM 744 102 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744102 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹46.0 L+₹3.0 L (7.03%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹44.8 L
EMD Value
₹89,700
Closing Date
9 Nov 2024, 6:00 pmClosed
GE HADDO PORT BLAIR
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
SPECIAL REPAIRS TO ELECTIC POLES WITH LIGHT FITTINGS AND CONNECTED WORKS AT SPORT COMPLEX MO (PBR) AND PROVISIONING OF QTY-4 SINGLE PHASE 3KVA VOLTAGE STABILISERS FOR ALL FOUR AFNET L2 SWITCHES AT HQ ANC UNDER GE HADDO, PORT BLAIR
2024_MES_680290_1
8925/E8
Open Tender
Civil Works
Item Rate
180 days
GE HADDO PORT BLAIR
As per tender document
9 documents required · 9 mandatory
₹500
GE HADDO
₹89,700
Yes
21 Jan 2025
19 Oct 2024
16 Nov 2024
19 Oct 2024
9 Nov 2024
2 Nov 2024
20 Oct 2024 - 26 Oct 2024
Amount
Excavation in trenches n. exc 1.5m wide and n. exc 1.5m in depth in soft/loose soil for foundation, etc or for shafts, wells, cesspits, manholes, pierholes, etc n. exc 10 Sqm on plan and getting out complete all as specified and directed
All as per Item No. 1 but additional 1.5m or part there of in depth beyond the first 1.5m complete all as specified and directed
M&L for returning filling in soil including spreading levelling watering and well ramming in layers n. exc 25cm thick for cable laying complete all as specified and directed
M&L for removing excavated material (any type of soil) to a distance n. exc 50m and depositing where directed at a level n. exc 1.5m above the starting point complete all as specified and directed
M & L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in filling, foundation and mass concrete complete all as specified and directed
M & L for precast cement concrete Type C2 1:3:6 (using 40 mm graded aggregate) for making foundation of pole/stay assembly complete all as specified and as directed.
M&L for precast cement concrete 1:2:4 type B1 (Using 20mm graded stone agrregate) for making copings including use and waste of form work complete all as specified and directed
Taking down carefully old unserviceable light fittings any type and dismantling old unserviceable steel poles complete all as specified and as directed.
M&L for steel tubular swaged poles 410 SP-55 (11 metres long) conforming to IS:2713 (Part-I) 1980, welded with mild steel base plate of size 300x300x6mm thick, finial taper plug, bolts, nuts and washers including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. Make : Kalinga Tubes/The National Tubes CO/India tube & CO/Jindal steel / Bansal Poles / Calcutta poles and tubes
Supply,laying,testing and commissioning of PVC insulated and sheathed LT XLPE , armoured heavy duty multistanded electric aluminium conductor cable 1100 Volts, IS-7098 Part-I marked, grade of cross section 2 core 10 sqmm (laid in terenches,ducts,pole,wall etc.) incl taking down old unsv cable all as specified and directed Make : Polycab/Gloster/Anchor/Havells/Finolex
All as per S Item No. 10.00 here in before but of cable size 4 core 25 Sqmm all as specified and directed Make : Polycab/Gloster/Anchor/Havells/Finolex
All as per S Item No. 10.00 here in before but of cable size 3.5 core 35 Sqmm all as specified and directed Make : Polycab/Gloster/Anchor/Havells/Finolex
M&L for cutting the road / footpath / hard standing etc for laying of pipe complete all as specified and directed by Engg-in-Charge
Supply and laying in trenches or in cable ducts or clamping on wall DWC HDPE pipe of size 50 mm(OD) x 38mm (ID) along with connected accessories like couplers.bends,end caps etc. for LT cable protection all as specified and directed. Make:Rex Poly Extrusion Ltd/Tirupati Plastomatics Pvt Ltd.
Supply & fix FRP pole box 195 x 135 x 90 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6-16 A MCB SPN (as required) 01 No. along with internal wiring including taking down the old/unserviceable junction boxes all as specified and directed. Make : Hansel / SINTEX Cat No. GS-JB-1414 Make of MCB: L&T/Havells/Legrand/ Indo Asian
Supply & fix FRP pole box 270 x 225 x 135 mm (inside dimension) consisting of 1 No 50 A 4 pole connector and 1 No 6-16 A MCB SPN (as required) 02 No. along with internal wiring including taking down the old/unserviceable junction boxes all as specified and directed. Make : Hansel / SINTEX Cat No. GS-JB-1414 Make of MCB: L&T/Havells/Legrand/ Indo Asian
Supply and fixing of LED flood light made up of pressure die cast aluminum housing with Toughened glass and highbpower LEDs and secondary lenses with IP66 protection of capacity 150 Watt ,220V 50Hz supply ,pressure Die cast aluminium housing and IP 66 Class I protection, System efficiency >= 110/120 LPW 10KV SPD included, to be fixed on pole mounted iron frame or bracket including removing of the old unserviceable halogrn / any type of light fittings complete all as specified and directed. Make: CG Model No : LFLN-150-CDL/60-M or equivalent model of /Philips/Havells/Luker
S&F of outdoor type decorative post top for 360 degree indirect light with IP 65 protection, resistant to impact and corrosion of 240V, 50Hz of capacity 40 Watt LED suitable for mounting 60mm OD pipe on necessary PCC works complete all as specified and directed Make : CG Cat Part No. LPTO-40-CDL-M or equivalent model of /Philips/Havells/Luker
S&F PVC Insulated and PVC round sheathed 2 core 1.5 Sqmm bright annealed bare copper conductor heavy duty flexible cables for voltage grade 1100 Volts for connection of lights from junction box complete all as specified and directed by Engg-in-Charge
M&L for 50mm dia or bore galvanised steel tubing, light grade, with all fittings and fixed to walls/poles or laid in floors complete as in protection of cables complete all as specified and as directed. Make : Tata/Jindal/Surya/Prakash/Bansal
Supply, install, testing and commissioning outdoor cubical feeder pillar box / LT panel, IP-65, suitable for 3 phase, 4 wire, 415Volts, 50 Hz Supply system and size not less than 1.1mtrs (L) X 1.43 mtrs(H) x 0.62 mtr (D) the panel shall be made with thermoplastic polycarbonate provision compartmentalized front openable single door system lockable lnner shell completely to accommodate incoming /outgoing MCCBs MCBS bus bars and extension links should be copper of capacity should not be less than 1.5 times of lncoming /outgoing MCCB/ MCB duly insulated with colour coded heat shrinkable sleves. All control wires shall be with 1.5 sqmm multi stranded copper conductors and shall be properly bunched tied ferrulled for proper identification and crimped with adequate size of lugs and provision and fixing of digital voltmeter, ammeter, CTs of ratio 125/5 A, 5VA, CL-1 and pilot indication lamps complete alongwith provision of necessary cableentry/exit boxes for all incoming and out going cables with suitable cable glands etc. The panel should be installed above ground, embeded in ground on suitable PCC foundations. Danger notice plate having conventional symbol of bone & skull be provided. The panel shall consits of following accessories:-
(i) Incomer (a) Incomer -MCCB 4 pole, 16/18 KA, 125 Amps thermal magnetic setting - 01No (ii) Outgoing (a) MCCB 4 Pole, 16/18 KA, 40 Amps thermal magnetic setting - 04 Nos (b) MCB DP 32 Amp, 10KA, type 'C' -03 Nos (c) Digital voltmeter AC 50 Hz of size 96 x 96 sqmm flush mounted - 01 Nos (d) LED type RYB phase indicator lamp - 01Set (e) All MCCBs should be with separator terminals. Note : Quoted rate is deemed to be included cost of MCCBs , voltmeter, Ammeter, indication lamps, change over switches andconnected wiring with necessary spreader links, lugs, glands and connecting of cables complete all as specified as per site conditions and all directed by Engr-in-Charge. Make : HENSEL or equivalent.in Indo Asian/ C&S Electric / Havells India Ltd
S&F fixing cross Arms, bracings, supports, clamps, eye hook etc structural steel sections including pole clamps stay clamps, D clamps nuts, bolts, washers welding bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
M&L for earthing complete with GI earth plate electrode of size 600mmx600mmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level connected to 4mm dia GI earth wire as earth lead connected by means of bolts, nuts, washers and check nuts made out of galvanised iron or steel all as shown on electrical plate No. 3 of SSR Part-I connected to common earth dolly including testing on completion complete all as specified and directed. Notice : (i) The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, pre-cast RCC (1:2:4) type B-1 using 20mm graded stone aggregate cover 50mm thick reinforced with TMT bars 8mm dia @ 100mm c/c both ways, funnel with watering pipe 20mm dia medium grade, GI protection pipe light grade 40mm dia and wire mesh complete in addition to item No. 1(a) to (e) of preamble (notes) under sub-heading earthing, specified on Sl. Page Nos. 422 & 423 of SSR Part-II. (ii) Earthing lead and GI protection pipe beyond 7.5m will be measured and paid separately.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of +(-) 2.5 % and of capacity 3 KVA complete all as specified and as directed by Engr-in- Charge. Make : V-Guard/Premier/ Kirloskar /Recon.
M&L for Point wiring complete with 4.0 Sqmm (nominal area) single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral), drawn through and including rigid non metallic PVC conduit of suitable size (not less than 25mm dia) and accessories fixed on walls/ceilings etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor green in colour for earth continuity and connected to common earth dolly and sunk in modular type pressed steel terminal boxes of suitable modules made out of 1.6mm thick MS sheet duly painted with two coats of anti-corrosive paint all over and modular cover plates with frames on top for suitable modules on top for housing switches, sockets etc., all as specified and as directed for the following:-
S & F for switch modular type, 16 Amps 1 module, 230 volts AC circuit complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
S & F Socket outlet 2 in 1 modular type, 3 pin, 6 and 16, universal complete all as specified and directed. Make-Roma (Anchor) / Havells (Crabtree) / Legrand
M&L for Sub main wiring complete with two runs of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor (with colour coding of Red/Blue/Yellow for phase and Black for neutral) and one run of 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor as earth wire green in colour including lugs, drawn through and including 32 mm wide rigid non-metallic PVC casing and capping and its accessories fixed in concealed or on surface of wall/ceiling/roof/ floor complete all as specified and as directed. Note: 3 runs of 4.0 Sqmm cable along with PVC casing & caping will be measured as one unit.
M/s Ramesh Lal (BID ID -3160580)
B S Grewal (BID ID -3160654)
M/S AMBER PAVER PRODUCTS (BID ID -3160575)
M/s Prem Enterprise (BID ID -3161289)
M/s K Moorthi (BID ID -3160566)
M/S VISHAL CONSTRUCTION (BID ID -3161246)
CHANDER SEKER ENTERPRISE (BID ID -3160874)
SKV Engineering (BID ID -3160987)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .