Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 13 218 MASJID EXTEN SADAR BAZAR | L1 | Accepted-AOC Being L1 tenderer | |
| 2 | L2₹34.7 L+₹42,536.20 (1.24%)Rejected-AOC | L2 | Rejected-AOC Not being lowest tenderer | |
| 3 | L3₹35.8 L+₹1.5 L (4.51%)Rejected-AOC NIVADA TIVAYA ROAD TIVYA MUST BUS STOP VILLAGE KHATAULI SAHARANPUR UP 247001 | SAHARANPUR | SAHARANPUR | UP | 247001 | L3 | Rejected-AOC Not being lowest tenderer | |
| 4 | L4₹38.7 L+₹4.4 L (12.9%)Rejected-AOC | L4 | Rejected-AOC Not being lowest tenderer | |
| 5 | L5₹40.0 L+₹5.8 L (16.8%)Rejected-AOC | L5 | Rejected-AOC Not being lowest tenderer |
Tender Value
₹43.0 L
EMD Value
₹85,900
Closing Date
28 Feb 2022, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
PROVN OF FLOOR TILES AND RENOVATION OF BATHROOMS AND KITCHEN IN BLDG NO P-114 AT ANUJ VIHAR MINOR WORK FOR ROOF TREATMENT OF BLDG NO P-68 PHILATELY MUSEUM AT 1 CBPO PROVN OF VIEW CUTTER ON THE PERIMETER FENCE TO PREVENT EXPOSURE AT THE DGIS OFFICER M
2022_MES_502546_2
GE/DS-80/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹85,900
Yes
23 Mar 2022
7 Feb 2022
2 Mar 2022
7 Feb 2022
28 Feb 2022
14 Feb 2022
8 Feb 2022 - 12 Feb 2022
Amount
B/R Works M&L for roughning sufaces of old concrete floor by packing, sweeping cleaning and washing down with water to remove dust etc brucing neat cement slury @ 3Kg of cement per Sqm complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) any description and thickness n.exc 25 mm and removal of rubbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for screed bed or bedding layer 15 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed by Engineer-in-charge.
M&L for backing coat 10 mm thick (cement mortar 1:4) on fair faces of brick work or concrete surfaces complete all as specified and directed by Engineer-in-charge.
M&L for vitrified Ceramic tiles 10 mm thick (square/ rectagular) polished, area of each tiles not exceeding 0.38sqm in floors/ wall etc, set and joint in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-charge.
M&L for vitrified Ceramic tiles 10 mm thick on vertical surfaces as in skirting/dado set and jointed in neat cement slurry and pointed in white or colour cement to match etc complete all as specified and directed by Engineer-in-charge.
S&F glazed ceramic tiles in colour, of size 300mm x 200mm x7mm thick, on vertical surfaces such as dados etc, set and jointed in neat cement slurry and pointed in white cement complete all as specified and directed by Engineer-in-charge.
Taking down shutter of any description exc 1 Sqm and n. exc 2 Sqm (refixing in same opening ) after cutting the bottom rail at requiared size complete all as specified and directed by Engineer-in-charge.
Dismantling of brick tiles (laid flat or on edge) on roof surface.laid bedded and pointed in any mortar complete all as specified and directed by Engineer-in-charge.
Demolition of mud in roof, any thickness, including plastering and leeping incl necessary scaffolding arrangement complete all as specified and directed(whether full thickness removed or only a part there of) and removing from cantonment area or as directed complete all as specified and directed by Enigneer-in-Charge.
M&L for brushing neat cement slurry with 3.00 Kg of cement per Sqm on existing surfaces complete all as specified and directed by Enigneer-in-Charge.
M&L plain cement concrete 40mm thick 1:2:4 type B-0 using (12.5 mm graded aggregate), as in roof, padding to maintain the uniform slope complete all as specified and directed by Enigneer-in-Charge.
M&L for rendering 10 mm thick using on concrete surfaces in CM (1:4) on roof, mixed with using water proofing compound and finishing the surface even and smooth without using extra cement complete all as specified and directed by Enigneer-in-Charge. Note:- WPC shall be measured and paid seperately under respective item of Schedule.
Supply only water proofing compound complete all as specified and directed by Engineer-in-charge.
M&L, Priming roof surfaces and applying water proofing treatment over roofs comprising of the following complete all as specified & as directed:- (a) Applying oil bound bituminous primer at the rate of 0.4 Ltrs/Sqm as per IS 3384-1986 on prepared surfaces. Surface shall be kept free till the moment, the primer is impregnated and the solvent oil in primer is evaporated. (b) Applying one coat of hot straight run bitumen @ 1.20 Kg/Sqm of grade 30/40 confirming to IS-73 (Grade S-35). (c) Laying 3mm thick APP polymeric water proofing membrane of weight not less than 3.6 kg/sqm, black finish reinforced with non woven polyster matt, with a thermo fusible finish, torching overlaps with a propane or a butane gas torch, with a overlap of 75mm at sides and 100mm at the ends and sealing including applying a coat of cold emulsion bituminous primer all as per manufacturer's instruction including preparation of surface. Note :- The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators. The contractor shall give 10 years guarantee for effectiveness of water proofing treatment, 2.5% of work done amount of this item shall be retained from contractors payment for a period of 10 years reckoned from date of physical completion of this work, or in lieu contractor may deposit bank FDR for the said amount for 10 years which shall be released by GE on expiry of satisfactory completion of 10 years period.
M&L cement concrete tiles 25cmx25cmx22mm thick, machine pressed, set jointed and pointed in neat cement slurry in floors, and cut and polished with grey cement and pigments over 15 mm thick screed bed in CM (1:6) complete all as specified and directed by Engineer-in-charge.
M&L for Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered and hold fast on edge including necessary form work complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc on walls and ceiling complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) complete all as specified and directed by Enigneer-in-Charge. Note:- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer. 3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for 10 mm thick cement plaster with readymix plaster (as per manufaturer's instruction) on fair faces of brick wall or concrete surfaces finished even and smooth, (without using extra cement) complete all as specified and directed by Enigneer-in-Charge. Note:- 1. Make of readymix plaster shall be Birla Aerocon/Ultratech readiplast/ACC Accoplast / Fosroc Chemical (India) Pvt Ltd Renderoc and as approved by GE) 2. The readymix plaster shall be procured directly from the manufacturer or their authorised dealer. 3 The contractor shall produced original purchase voucher alongwith test certificate of readymix plaster while claiming RAR/ Final Bill.
M&L for Preparing new plastered or unplastered surfaces of wall and ceiling and applying two coats of cement base paint, white or tinted complete all as specified and directed by Engineer-in-charge.
Excavating in post holes (or similar holes) each not exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance not exc 50m and making good surface, work in soft/loose soil, complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:2:4 Type B2 using (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel as in framed work using angle iron ,flat iron fillet etc including necessary cutting, drilling, welding as required complete all as specified and directed by Engineer-in-charge.
S&F Pre-Painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
Preparation of new untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-charge.
M&L for Excavation in trenches n.exc 1.5 mtr wide and n. exc 1.5 mtr in depth for foundation etc or shafts wells, cesspil, manhole, piperholes etc and getting out soft/loose soil complete all as specified and directed by Engineer-in-charge.
M&L for PCC/ Bitumen road cutting upto depth 200mm for laying of hume pipe after laying repair the surface as per exisiting surface complete all as specified and directed by Engineer-in-charge.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-charge.
M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engineer-in-charge.
M&L PCC 1:4:8 type D2 (Using 40mm grd agg ) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as incasing of RCC hume pipe with necessary form work complete all as specified and directed by Engineer-in-charge.
M&L for Cement concrete Type B-2,1:2:4 using (40mm graded stone aggregate) as in surface channels and drains complete all as specified and directed by Engineer-in-charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped end etc complete all as specified and directed by Engineer-in-charge.
M&L for brickwork with subclass ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for 15 mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4, surface is to be finished even and smooth (without using extra cement) including one coat of primer complete all as specified and directed by Engineer-in-charge.
M&L for providing perforated precast cement concrete 1:2:4 Type B1 (20 mm graded aggregate) cover slabs for drain, set as in cement mortor 1:4 with plain fair faces, including chamfers weatherings, throating etc. and cleaning old material before setting in mortar complete with joints to match, including necessary form work complete all as specified and directed by Engineer-in-Charge.
Mild steel TMT bars 6mm to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced concrete pipes , class NP3 laid and jointed complete with collars 600 mm dia (internal) in trenches & jointed etc complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 600 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-charge.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) exceeding 1.5 Sqm but not exceeding 4 Sqm each complete all as specified and directed by Engineer-in-charge.
Cutting holes in brick walls, built in cement mortar or cement lime mortar, exc half brick but not exc Half brick, for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 and match with Clour existing surface type B1 as required complete all as specified and directed by Engineer-in-charge.
S&F for clamps; hold fast; bands, straps, supports or stays for galvanised plain mild steel wire including bolts, rainwater, ventilating pipe and simillar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed by Engineer-in-charge.
S&F rolled mild steel grade Fe-290 Gde-E-165 quality-A as in framing for doors cladding, chowkhats/frame or like etc welding hold fast, hinges complete all as specified and directed by Engineer-in-charge.
M&L for joint free coloured glazed ceramic tiles in vertical surfaces 300x200x7mm/450x300x7mm thick set and jointed in cement slurry and pointed in white or coloured cement to match laid over & including 15mm thick cement rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premices complete all as specified and directed by Engineer-in-charge.
M&L for joint free non skid coloured ceramic tiles, 7 to 8mm thick (squre or rectangular) area of each tile n.exc. 0.11sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces, laid over & including 15mm thick screed bed in cement mortar 1:4 complete all as specified and directed by Engineer-in-charge.
S&F Prelaminated particle board,18-19 mm thick interior grade prelaminated both side decorative choice lamination & other side balancing white lamination, with all sieds 18x6mm wooden beding.fixed with screws to timber frame work complete all as specified and directed by Engineer-in-charge.
S&F Prelaminated particle board,18-19 mm thick interior grade prelaminated both side decorative choice lamination & other side balancing white lamination, with all sieds 18x6mm wooden beding.fixed including 25x 50 mm wooden Frame Below selvswith screws to timber frame work complete all as specified and directed by Engineer-in-charge.
S&F for butt hinges, stainless steel, ISI Marked 100mm size, complete all as specified and directed by Engineer-in-charge.
S&F for extruded aluminium alloy handles, fabricated type, anodised, 125 mm size complete all as specified and directed by Engineer-in-charge.
S&F for aluminium anodised hasp & staple including bolt hinge plate and fixed with screws 100mm size complete all as specified and directed by Engineer-in-charge.
S&F Magnetic catch for wooden cupbord with complete closer macanigum claps and clips fix with stainless steel screw complete all as specified and directed by Engineer-in-charge.
Surface excavation in soft/loose soil, not exceeding 30cm deep and averaging 15cm deep and getting out, complete all as specified and directed by Engineer-in-charge.
M&L for hard core of gauge n. exc 63 mm deposited ,spread levelled in layers n. exc 15 cm thick watered and rammed to a true surfaces complete all as specified and directed by Engineer-in-charge.
M&L for 75 mm thick plain cement concrete 1:3:6 type C2 (using 40 mm graded stone aggt) as in sub base of floor / plinth proctions etc finished surface fair & even complete all as specified and directed by Engineer-in-charge.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thick, M-35 grade fixed with grey cement and pigments complete all as specified and directed by Engineer-in-charge.
Sand filling under floors or in foundation including watering and consolidation for Paver block complete all as specified and directed by Engineer-in-charge.
M&L for roughning sufaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc brushing neat cement slurry @ 3Kg of cement per Sqm complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:3:6 type C2 (Using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B1 (Using 20mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges, cills, steps, seismic, and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs for water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
E/M Works Taking down carefully the old U/S Aluminium / Copper point wiring (light, fan, socket or power) complete fitting such as switches, ceiling roses, pendants, sockets, regulators, etc and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Enigneer-in-Charge.
M&L for point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through existing concealed PVC/ MS Conduit and including replacement of unserviceable pressed steel terminal boxes with Modular steel terminal boxes including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable earth continuity wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one 5 Amp switch one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) complete all as specified and directed by Engineer-in-Charge. Notes :- In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per item No 63 above but One 3 pin socket outlet, 5/6 Amps, independent, with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit.
All as per item No 63 above but 5 Amp socket outlet on same board.
All as Item No 63 above but for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing with through existing concealed PVC/MS conduit.
All as Item No. 63 above but for one light point controlled by two 2-way switches with cable 1.5 Sqmm size.
S&F switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engineer-in-Charge.
S&F switch piano type 15/16 Amps SP one way complete all as specified and directed by Engineer-in-Charge.
S&F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engineer-in-Charge.
S&F 0-4 step type electronic fan regulators for ceiling fan 1200/1400 mm sweep, 240V all as specified.
S&F switch piano flush type 5/6 Amps SP 2 way complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ,Decorative wall light mounting suitable for LED Lamp upto 15 Watt with all connections complete all as specified and directed by Engineer-in-Charge. .
S&F in replacement Wall mounted LED Integrated Batten 20 Watt - 4Ft White, indoor decorative PVC extruded LED battern complete all as specified and directed by Engineer-in-Charge.
S&F LED bulk head in engineering plastic housing with clear prismatic diffuser, 10W WHITE in replacement of old unsv bulk head fitting including all accessories connecting up twin core flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Wall mounted LED Integrated Batten 10 Watt-2 Ft White, indoor decorative PVC extruded LED batten, complete all as specified and directed by Engineer-in-Charge.
S&F LED RETROFIT Lamp of 12 Watt for fixing in batten holder/wall mounting/bulkhead point complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of building security light fitting 45W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for pole dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc complete all as specified and directed by Engineer-in-Charge.
S&F metal body exhaust fan 450 mm sweep, 230 Volts with louvers complete and copper wound (Heavy duty-1400 RPM) including necessary electric connection with appropriate size of PVC copper wire from ceiling rose/switch board to exhaust fan including fixing of nut-bolts of suitable size and making good the disturbed surface of wall with OBD/White wash to match with existing complete all as specified and directed by Engineer-in-charge.
S&F BLDC (Bruishless Direct Current) ceiling fan of 1200mm sweep, not less than 350 RPM and Air Delivery 215 cfm, Voltage 220V, high air flow with silence operation, having full copper motor & ribbed 3 Nos A/M blades. The BLDC motor fan shall have 100% rust-free blade. the fan shall have BEE 5 star rating and compliant with IS-374 and making necessary electric connection of suitable PVC copper wire from ceiling rose to ceiling fan including taking down old ceiling fan and deposited to MES store yard complete all as specified and directed by Engr-in-Charge.
S&F in replacement of single pole and neutral metal clad sheet steel enclosures with 2 pin and earth plug and socket complete with one no MCB SP 20 Amps as per site requirement of existing type, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of VTPN DB triple pole and neutral 4 way for fixing MCCB up to 125 Amps as incomer and MCBs as out goings with metal double door and IP 43 Protections and connecting complete including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 100 Amp 3 pole, 415 V, 16kA in replacement old unsv isolator any type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB SP 40 Amps 'C' series, breaking capacity 10 KA, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB DB SPN 12 Way double door type, (IP 43 Protection) flush mounting for MCBs complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB DB SPN 4 Way double door type, (IP 43 Protection) flush mounting for MCBs complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SP 6 to 32 Amps 240 Volts, 10 KA, `C' curve, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement for MCB SPN 32Amps, 240 Volts, 10 KA, `C' curve, complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring in replacement of PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia complete all as specified and directed by Engineer-in-Charge. Note:-(a) Two runs of main cable and one run of earth cable all-together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for Earthing complete with galvanized steel earth plate 600x600x6mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate n.less than 1.5 m below normal ground level, connected to galvanized iron wire 4 mm as earthing lead by means of bolts, nuts, check nuts & washers of galvanized iron or steel besides building at all joints as shown in drgs and including excavation and earth work, GI pipe light grade 25mm bore of protection of GI wire from earth electrode, supply and laying charcoal dust, common salt, PCC (1:2:4) type B-1 Chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type B-1using 20 mm graded stone aggregate Reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia , PGI funnel and wire mesh , 20 mm dia GI Pipe light grade for watering complete all as shown in drg and connected to earth test point including testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement ,Decorative wall light mounting suitable for LED Lamp including 12 Watt LED Lamp complete with all connections complete all as specified and directed by Engineer-in-Charge. .
S&F in replacement Surface mounting round shaped LED downlighter with durable housing with Al heat shrink with diffuser to give glare free light 12 Watt LED 6000K/6500K lamp type from ceiling of stairs/common areas, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of LED Building security light fitting 30 Watts and including taking down of old unsv existing building security light fitting any type, from existing bracket with and including replacement of unsv bolts,bracket, nuts and washers etc complete, all as per site requirement complete all as specified and directed by Engineer-in-Charge..
S&F in replacement of VTPN DB 4 way double door, vertical type for fixing MCCB up to 200 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engineer-in-Charge..
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCCB 3 Pole .415 V. fixed type, 160 Amps with breaking capacity 36kA complete all as specified and directed by Engineer-in-Charge.
Taking down and refixing of ceiling fan any size including all accessories connecting up twin core flexible copper conductor cable complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring in replacement of PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC concealed conduit 25 mm dia complete all as specified and directed by Engineer-in-Charge. Note:-(a) Two runs of main cable and one run of earth cable all-together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
M/S.Parmod Johar
Chaudhary Constructions
P R Constructions
ramveer Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .