| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.2 CrAccepted-Finance NO 143 1 ARTHI NAGAR 2ND STREET NARASOTHIPETTAI KURANGUSAVADI SELAM 636 304 | SALEM | TAMIL NADU | 636304 | ₹11.2 Cr | L1 | Accepted-Finance Accepted |
| 2 | L2₹11.8 CrRejected-Finance NO 21 ANAIGOUNDEN PUDUR VELLOTTAMPARAPPU POST ERODE TAMIL NADU 638154 | ERODE | TAMIL NADU | 638154 | ₹11.8 Cr | L2 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | PONKULALI AND CO L2 | SRI VARI CONSTRUCTIONS L1 |
|---|---|---|---|---|---|
| 1.00 | Clearing Scrub Jungle and Surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish from site, lead upto 50m, transportat charges and labour charges etc., complete complying with standard specification. | 665 | Sqm | 8 ₹5,320 | 8 ₹5,320 |
| 2.00 | Dismantling & removing the existing Reinforced Cement Concrete work etc., by using required mechinaries including stacking of steel bars and disposal of unserviceable material within 50m lead, labour charges, as per direction of Engineer in charge. | 14 | Cum | 5,630 ₹78,820 | 5,377 ₹75,278 |
| 3.00 | Dismantling brickwork manually by mechanical means including stacking of serviceaboe material and disaposal of unservice material within 50 meters lead as per direction of Engineer in charge.. | 45 | Cum | 371 ₹16,695 | 355 ₹15,975 |
| 4.00 | Carting away surplus excavated earth / Debrish available with in the campus is to be carted to a lead of within 10 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge. | 458 | Cum | 230 ₹1.1 L | 220 ₹1.0 L |
| 5.00 | Replacing(translocation) of existing tree from the site to new alloted location The rate shall include loading into the tipper/ lorry transporting and unloading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge. | 8 | No | 68,265 ₹5.5 L | 65,190 ₹5.2 L |
| 6.00 | Providing and constructing cast in situ hydraulic bored piles of 600mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). | 1,580 | Rm | 6,412 ₹1.0 Cr | 6,123 ₹96.7 L |
| 7.00 | Providing and constructing cast in situ hydraulic bored piles of 450mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). | 65 | Rm | 4,137 ₹2.7 L | 3,951 ₹2.6 L |
| 8.00 | Providing and constructing cast in situ hydraulic bored piles of 300mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc ., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). | 198 | Rm | 2,479 ₹4.9 L | 2,367 ₹4.7 L |
| 9.00 | Carrying out initial pile load test on specified 600mm dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete | 2 | No | 6,25,691 ₹12.5 L | 5,97,507 ₹12.0 L |
| 10.00 | Carrying out Dynamic load test on Bored cast-in-situ pile as specified in IS:2911 (Part 4)for specified test loads.( 600 mm dia ). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete | 2 | No | 2,77,500 ₹5.5 L | 2,65,000 ₹5.3 L |
Tender Value
Refer Docs
EMD Value
₹5.0 L
Closing Date
18 Feb 2026, 3:00 pmClosed
Superintending Engineer II
Superintending Engineer II, CW, Koyambedu, Chennai
Construction of Multi Purpose centre at Kakkanji Nagar Vyasarpadi Chennai
2026_CMDAC_657410_1
20(a)/2025-26_Kakanji Nagar
Open Tender
Civil Works
365 days
Kakanji Nagar, Vysarpadi
Registration of Contractor Certificate
Annual Turnover
Similar Work experience
GST Registration
Income Tax Return
Pan card
7 documents required · 7 mandatory
₹0
₹5.0 L
Yes
20 Feb 2026
14 Feb 2026
19 Feb 2026
14 Feb 2026
18 Feb 2026
15 Feb 2026
Clearing Scrub Jungle and Surface dressing of the ground. The rate including hire charges of all machineries, removing of all rubbish from site, lead upto 50m, transportat charges and labour charges etc., complete complying with standard specification.
Dismantling & removing the existing Reinforced Cement Concrete work etc., by using required mechinaries including stacking of steel bars and disposal of unserviceable material within 50m lead, labour charges, as per direction of Engineer in charge.
Dismantling brickwork manually by mechanical means including stacking of serviceaboe material and disaposal of unservice material within 50 meters lead as per direction of Engineer in charge..
Carting away surplus excavated earth / Debrish available with in the campus is to be carted to a lead of within 10 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Replacing(translocation) of existing tree from the site to new alloted location The rate shall include loading into the tipper/ lorry transporting and unloading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in- charge.
Providing and constructing cast in situ hydraulic bored piles of 600mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).
Providing and constructing cast in situ hydraulic bored piles of 450mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).
Providing and constructing cast in situ hydraulic bored piles of 300mm diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³ in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipment's like piling rigs, temporary casing of appropriate length for setting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method duly through all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc ., Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap).
Carrying out initial pile load test on specified 600mm dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete
Carrying out Dynamic load test on Bored cast-in-situ pile as specified in IS:2911 (Part 4)for specified test loads.( 600 mm dia ). Includes all plant, equipment, machinery, instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete
Carrying out Pile integrity test (PIT) on the piles under each cluster by using a 6 lbs nylon lipped hand held hammer, glueing sensitive accelerometer on top of the pile by petro wax or petroleum jelly after making the pile head smooth and even by disc grinder, providing stage wise and final report along with revevant conclusions etc., as directed by Client / engineer-in-charge. as per latest IS-2911.
Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers.
0.0m to 2.0m depth
2.0m to 3.0m depth
Supplying and Filling with M - sand in foundation and others sub structures for 100mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of M sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification
Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive of giving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12"to a depth of 8" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc.,
Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation.
Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth.
Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over.
Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12" to a depth of 8" around the building before laying the plinth projection. This holes has to be be closed after the treatment.
Supplying and filling with Gravel or good earth well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers.
Construction of Granular sub-base of 150mm compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401 ,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers withmotor grader o n prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading maintenance of diversion road loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORTH technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work
Providing and laying, spreading and compacting graded stone aggregate to Wet mix macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage to mixed material by tipper to site laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achive the desired density complete as per clasue 406 of MORTH specifications.
Providing and laying plain cement concrete 1 : 4 : 8 ratio of (1 cement , 4 M sand and 8 graded stone aggregate 40mm nominal size) in foundation and basement including dewatering wherever necessary and laid in layers not more than 15 cm thick and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification.
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with
For column footing plinth beam bed blocks templates staircase, steps piers, raft beam, raft slab etc.
For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
for plane surfaces such as rectangular or square rcc columns, sunshades, top and bottom slab of rcc boxing, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical walls etc.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
strutting 1m/1sqm
Providing and laying in position, Standardised Concrete Mix M- 30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/ms and maximum water cement ratio of\ |0.45, including admixture (plasticiser/ super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of |concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone 10 jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but |excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including
Foundation and Basement
Ground Floor
First Floor
Second floor
Third floor
Terrace Floor
Supplying, fabricating and fixing in position of steel Fe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-incharge.
Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure using Fly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastages for working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.
Foundation and Basement
Ground Floor
First Floor
Second Floor
Third floor
Terrace floor
Fly ash Brick partition walls of 11.50cm thickness using best quality Fly Ash Bricks of size 23 x 11 x 7 cm in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
Ground Floor
First Floor
Second Floor
Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails.
Upto 3 M Height
For every additional height of 2.5 M (3m - 5.50m)
For every additional height of 2.5 M (5.50m -8.00m)
For every additional height of 2.5 M (8.00m -10.50m)
For every additional height of 2.5 M (10.50m -13.00m)
For every additional height of 2.5 M (13.00m -15.50m)
For every additional height of 2.5 M (15.50m -18.00m)
Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of P sand) according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. The rate including cost of all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturer's Specification with sponge finish (washed sand finish) all complete as per specification and as directed.The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing, cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge
Supply and painting of two coats of Acrylic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer. Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Client / Engineer-in-charge.(Ceiling & Internal surface)
Supplying and painting of 2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete. The rate including cost of materials, brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations, transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer- in-charge.
Supplying and fixing Dadooing the wall with Wall Mosaic of approved quality, colour and design joint free of size 300x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supplying and laying of Flooring with Full Body tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.. (Including Skirting)
Paving the floor with best quality Stain Free Nano Polish Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works)
Providing Ceramic tiles of size 305 x 305 x 6mm flooring approved make and quality with plain/colour with base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc.,
Supply and laying flooring with best quality the following materials of Machine Polished granite slab not less than 18 mm thick Grey Granite in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge.
Supply and Laying flooring with best quality approved colour 18mm thick Flamed Steel Grey Granite Slab for Staircase and Ramp flooring of size not less than 1200 x 600 mm machine cut and set in C.M 1:4 (1 of cement: 4 of manufactured sand) 20 mm thick topped with white cement slurry (tor surface contact of the bottom of the granite slab) as per approved pattern, Including tinishing the joints with matching shade cement slurry,cutting, edge chamfering and polishing rough medium, nice and tin-oxide polish.Rate including all materials, labour charges wastages, necessarylead and lifts, working at all levels, transportaton charges, loading, unloading. preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, antiskid grooves,tools and plants, fuel,
Polishing and Nosing the Granite Slab To Half Edge to round shape and finishing the surface neatly etc. complete complying with standard specification as directed by department officers
Nosing of Granite - Double Nosing
Terrace WaterproofingSupply and laying water proofing treatment for terrace covering the following order and consisting of following operations.i) Making V' grooves at the construction joints of size 20 x 20 mm and filling the "V" Groove with CICO No. 3 Quick Setting WaterproofingCompound admixed with cement.The roof slab gutter slab shall be thoroughly cleaned to remove debris and dust, and applying 2 coats notless than 2 mm of polymer based Elastomeric Coating like TAPECRETE - RTU compound and cured for 7 days and followed by a layer of 20 mm thick cement mortar 1:3 admixed with CICO NO: 1 (or) other approved equivalent make shall be spread over the prepared surface
The gap cement mortar 1:4 admixed with compound like CICO NO:1 or approved equivalent afterwards curing shall be carried out for two days a final layer of cement mortar of 1:3 admixed with water proofing compound like CICO NO:1 or approved equivalent make shall be laid to a thickness of 20 mm and draw a false line of 300 mm x 300 mm.
On the spread mortar provide and lay well burnt brick bats (COBA) to a average minimum thickness of 55 mm (i.e.. minimum 40 mm thickness at lower end and 70 mm thickness at higher end). An additional layer of brick bat (COBA) shall be laid over the existing brick bat COBA surface if required to get the required gradient for adequate drainage giving a slope of approximately 1 in 120, which will be measured separately under relevant item.
The parapet side wall / gutter wall shall be thoroughly cleaned to remove all dust particles and a layer of 15 mm thick C.M 1:3 shall be laid to a height of about 300 mm above the top of the terrace/Gutter slab on the Parapet / Gutter side wall admixed with water proofing compound like the CICO NO:1 or approved equivalent make. Providing, supplying, mixing, applying two coats of ready to use two component Acrylic polymer modified cement based, flexible, water proofing slurry like or approved equivalent to a thickness of 2 mm over the plastered surface of operation as per manufacturer's specification and as directed.(Plan area of Terrace only will be measured for payment )
Supplying and laying of Top of roof with Solar reflective tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three crushed stone sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as per The the direction of the Engineer-In-Charge. make and brand of the tiles should be got approved by the Executive Engineer before useon works)
Granolithic flooring 40mm thick with cement concrete 1:2:4 (1cement and 2 Crushed Stone Sand (Commercially called M- Sand) and 4 blue granite broken stone jelly 3to 10mm gauge) and top rendered smooth with cement at 10kg per10sq.m. including thread lining,curing,providing 25mm diaG.I.pipe of necessary length for water outlet etc.,complete asdirected during execution.
Supplying And Fixing of Rubber Moulded Grey Premium Concrete Pavers of Size 200X200X65mm Using M30 Concrete Placed Over 50mm Thick Crushed Stone Sand (M Sand). The Concrete Shall Be Moulded By Table Mount Vibrated With Polypropylene Fibers At 5% And Curing Compound. The Rate Shall Include Cost of Materials Transportation Loading Unloading Charges And All Taxes Including Filling of All Joints With Labour Charges Etc.
UPVC Window :Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm125GSMand 100% corrosion free, the profiles are multichambered sections with wall thick of 2mm. The EPDMrubber (black colour) covered with over all the edges offrame and shutter the shutter will be provided withEspag multi power point locks and also it operates ashandle. The corners and joints should be welded andcleaned. Radiations free pin headed plain or browncolour glass 4mm thick should be provided to theshutter and it should not allow leakage of water evenat most ranging storms and should have key lockableaction, security protective hinges, strong
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Providing and fixing welded M.S. grills to the window openings,along the details as per drawing with necessary screws, bolts and fixed with necessary M.S. lugs embedded in masonry with C.C. 1:2:4 and finishing the surface neatly. Rate shall welding and consumables, etc. complete, as directed. Design of grills and the size of members to be used shall be got approval before put into use & as directed by the Client / Engineer-in-charge.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors including cost of priming coat etc., complete complying with standard specification. ( The make quality and colour of paint should be got approved by the executive Engineer before use on works.)
Supplying and fixing solid core flush shutter 35mm thick with commercial ply on both sides, teak lipping alround with 1mm thick laminate on both sides with necessary adhesive and C.P.screws, including fixing for aldrop , tower bolt, hinges and lock strike plates , putty, fevical etc., and including the cost of aluminium hinges 125x 30mm size -3 Nos. aluminium aldrop of size 250x16mm 1No, Aluminium tower bolt of size 250x12 mm -1 No. , Aluminium tower bolt of size 200x12mm-1 No, aluminium door stopper with Nylon bush-2No. shall be provided. All aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1962 for anodic film thickness of not less than 15 microns. The rate is inclusive of cost of fevical, fixing charges, transportation, loading, unloading all other incidental charges and handling charges etc., complete complying with standard specification.
Steel Door - Elec & Pump Room
a) Door Frame : Fabricated from galvanized steel sheet to the profile and the thickness specified below : i. Fire Door- 1 Hr rating: Single rebate profile of size 100 x 57 mm (+/-0.3) with bending radius of 1.4 mm, using galvanized steel sheet of 1.20 mm thick (18 Gauge).
Frames shall be provided with the following i) Back Plates- 3mm thick on all jambs with provision for anchor bolt fixing to wall openings. ii) Hinge plates 3 mm thick pre-drilled to receive approved type and make of hinges for screw mounted fixing iii) Factory finish-pre-punched cut outs to receive specified type & make of hardware and iron mongery. All cut outs including hinge plates, strike plates to have mortar guard covers from inside to prevent cement, dust ingress into cut outs at the time of grouting of the frame iv) Reinforcement pads for fixing of door closer, locks and handles at appropriate location as per manufacturer's detail v) Plug-in type rubber silencer not less than 2 mm dia shall be provided on the strike jambs for single shutter frames and on the head jambs for double shutter frames. vi) Frames shall be in knock down form with butt joints for bolted assembly at site or as per manufacturers specification with out visible joints/welding marks in frames.
c) Door Shutter : Shutters should be press formed with double skins to total thick as below hollow shutter with lock seam joints at stile edges using galvanized steel sheet of thickness specified below i) Fire Door-2 Hour raling 0.80 mm thíck (19 Gauge). -48 mm
Shutters shall be provided with the following i) No visible screws or fasteners on either face and Internal reinforcement shall be provided at top, bottom and stile edges for desired fire rating. ii) Factory prepared shutter with pre-punched cutouts and reinforcement pads to receive the approved type and make of Hardware and lron mongery iii) Pre-drilled hinge plates with hinge guard covers and shutters with locks to have concealed lock box with lock fixing brackets with pre-tapped holes and screws. iv) Reinforcement pad at appropriate location to receive the hinge, vision panel, flush bolt ,locks, Door closer, Panic Bar, etc. as per the approved type and make of Hardware and all as per manufacturer's design and conforming to Standards. v) Necessary provision / fixing arrangements shall be provided in the shutter as well as in the frame to receive / fix the Electro magnetic latch, Electromagnetic contact for hooter with reinforcement pads and in such a way to connect the same to the card access control system / IBMS.
c) Infill material: Honeycomb paper core as infll material and to be bounded to the inner faces of the shutter or as per Manufacturer's specification. Door should have been tested with Infill material proposed by the manufacture and the same should have been approved by CBRI / BFRC
d) Finish: Surface of the frame and shutter shall be cleaned suitably & thoroughly with solvents and as per manufacturer's specification. Apply Zinc etch primer coating as shop coat to receive additional coat of primer and top coats, apply stove zinc phosphate primer (35 microns DFT) DFT) as additional coat and finish the surface neatly with thermo setting polyurethane paint (35 microns DFT) of approved colour and make.
e) Installation : The frame and shutter shall be installed in position as per the methodology described in the Technical specification with necessary accessories, tools & Plants etc
f) Grouting: Frame shall be pressure grouted with cement slurry 1:3 ratio or filling the pre cast solid block core to the frame profile as approved. The surface after grouting shall be neatly cleaned and to be ensured that there is no scratch in the door frames after grouting. Back fll the frame through holes provided and insert plug in type nylon plugs after cleaning the surface and to suit the frame finish and colour.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths,interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover
Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS (Sliding door) etc., with frame complete and as directed by the departmental officers.
Best Indian Teak Wood panelled and glazed door in double shutters with glazed head. The size of frames shall be 100x75mm at side,verticals,top transom and centre vertical for head. The height of glazed head is 40cm using 595 gm.glass panes for head. The shutters shall be of 40mm thick with moulded panels in 20 mm thick planks for the panelled portion and 595gm.glass panes for the glazed portion. 6Nos.of iron hold fasts fixed in C.C.1:2:4. 6Nos.of butt hinges 125mm long including wind appliances, furniture iron fittings.1No.of iron padlock 15cm long for locking arrangements and fixing in position with 2Nos.of 20mmdia M.S horizontal bars for the head portion, etc., complete. (ISISTD)
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete
Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturer's specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge
Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturer's specifications and as directed.
Supply and laying Terrace water proofing treatment for bottom and sides of RCC pond covering the following order and consisting of following operations. Supply and laying water proofing treatment for bottom and sides of RCC pond covering the following order and consisting of following operations. Supply and laying water proofing treatment for bottom and sides of RCC pond covering the following order and consisting of following operations. iii) Sealing off the nozzles and level the surface using integral Waterproofing compound CICO NO.3 or approved equivalent in the ratio 1:1by weight.iv)The concrete slab shall be thoroughly cleaned to remove debris and dust, and application of two coats not less than 2 mm thick of TAPECRETE - RTU Polymer Based Elastomeric Waterproof
Weathering course-using broken brick jelly 20 mm gauge in pure slacked lime (No sand to be used) over RCC roof slab. The proportion of broken brick jelly to slaked lime being 32:12½ cft well beaten by wooden beaters for giving required slope. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, transportation charges, loading, unloading, with all respects complete complying with relevant standard specification and as directed by the Engineer-in-charge
FALSE CEILING WITH GYPSUM BOARD Providing and fixing suspended false ceiling using SAINT - GOBAIN GYPROC or Equivalent make which includes providing and fixing GI perimeter channel of size 0.50mm thick having one flange of 20mm and another flange of 30mm and a web of 27mm along with perimeter of ceiling, screw fixed to brickwall / partition with the help of nylon sleeved and screws at 610mm centres. Then suspending GIintermediate channels of size 45mm, 0.9mm thick with two flange of 15mm each from the sofit at 1220mm centres with ceiling angle of width 25mm x 10mm X 0.55mm thick fixed to sofit with GI cleat and steel expansion fasteners. ceiling section 0.55mm thickness having knurled web of51.5mm and two flanges of 26mm each with lops of 10.5mm are then
Structural Glazing: Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875. Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12 16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x 53mm for frame horizontal section and section for reinforcement should be of 31 x 55mm. glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm. Accessories: Brackets made of CRCA powder coated / electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement. Polyurethane brackets should be used to connect horizontal section to vertical sections. Silicone: Natural cure, with good UV resistance to be used. The above frame should be fixed to brick / concrete masonry by using nylon self–expanding cap and driving MS electro plated 80mm long screws into the caps through frames. Glass: 5mm reflective
Supply and fixing Acrylic Solid Surface Corina Wall cladding panels Exterior grade with 12mm thick solid solid surface with LED backlighting to be non-porous and homogeneous seamless, stain resistant, repairable, durable and UV resistant surfacing material acrylic solid surface sheet of or approved make with a minimum thickness 12 mm in color, design, fixing in customised CNC engraving and cutting design arrangement as per direction of architect/Engineer. Acrylic solid surface sheet to be fixed on wall on top of Aluminium Channels complying it IS standards to withstand wind load.Adhesive of the same colour and make to provide inconspicuous joints. Thermoformable Acrylic solid surfaces should be used wherever required and shaped/bent using heat. Acrylic solid surfaces should be as per requirement in relevant colour and should be developed as per design. The LED backlighting should be of approved make and backlighting should have even spread and seamless.The rate is inclusive of all operation including transportation loading unloading and fixing of material and required pattern to be CNC engraved / Cut , buffing polishing to smooth finish, including cost of aluminium frame work and Scaffolding arrangements Complete. The final finished product should be seam less, joint less and shall maintain lustre and when etched it should have a smooth finish.
Providing And Laying of Hot Applied Thermoplastic Compound 2.5 mm Thick Including Reflectorising Glass Beads @ 250 Gms Per Sqm Area, Thickness of 2.5 mm Is Exclusive of Surface Applied Glass Beads As Per Irc:35 The Finished Surface To Be Level Uniform And Free From Streaks And Holes Etc Completed As Per Mort& H Specification No.803
Supplying and fixing of Room and Toilet Sinages of size 24" inch x 12" inch using 3mm acrylic board with individuals letter viniyl print with double border and laser cutting with hole corner and machine pasting etc., The rate including cost of all materials, Labour charges and transport charges etc., complete with realent standard specification.
Manufacturing, Supplying and fixing Brass cut letters of size 30cm height and 18mm thick. (Rate as per quotation inclusive of all Labours, Material & Transportation)
Providing band cornice work 350mm wide and 75mm deep using country bricks in cement mortar 1:4 (1 cement and 4 Crushed Stone Sand (Commercially called M-Sand) plastered with cement mortar 1:4 (1 cement and 4 Crushed Stone Sand (Commercially called M-Sand)),12mmthick including rendering smooth with cement at 22.5kg per 15m length,curing,necessary scaffolding and centering,etc.,completeas directed during execution.
INTERNAL PIPE LINE
Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm 'P' os 'S'' trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank.
Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing the best quality approved make of Two way bip cock with C.P. health faucet Hindware make (F160001) wall hook one metre long flexible tube, angle cock with wall flange including cutting and making good the walls wherever required etc.complete, complying with standard specification and as directed by the Department officers. The quality and make of health faucet should be got approved by Executive Engineer before use on work.
Supply and fixing in position of best Indian make white / colour glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Suppling and fixing in position 15mm diameter brass / C.P screw down tap / pillar tap / swan neck tap (heavy duty) of approved make conforming to I.S.specifications and quality including cost of shellac, thread etc.complying with standard specifications and including cutting and threading wherever necessary
Supplying and fixing heavy duty 15mm CP shower unit comprising of CP 15mm dia hot & cold mixer with CP spout, overhead shower set comprising of CP shower arm, rose etc.,complete with CP wall flanges. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge.
Supplying and fixing best approved quality Brass C.P / Al anodised Towel rail 600mm. long and 20mm Diameter with brackets of same material including cost of Teak-Wood plugs and C.P.Screws etc., complete complying with standard specifications
Supplying and fixing in position C.P. Soap tray of size 150 x 150mm including cost of teak wood plug and C.P. screws. etc. complete complying with standard specification.
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks)
Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly lime concrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) including dismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ).
Supplying, laying and jointing CPVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The CPVC pipes shall be got approved by Executive Engineer before use on works.
20mm dia Pipe conceled water supply
25mm dia Pipe
32mm dia Pipe
40mm dia Pipe
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
Supplying laying and jointing P.V.C pipes soil/ waste pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to wall with necessary teak - Wood Plugs,PVC Clamps and screws,making holes on the wall or drilling holes in roof and making good the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges.
110mm dia Pipe
75mm dia Pipe
40mm dia Pipe
EXTERNAL PIPE LINE
Supplying and fixing in position 150 x 100mm "P" or "S" stoneware gully trap 'A' grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three Crushed stone sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works.
Construction of Sewer Inspection chamber or manhole of the following size including necessary earth work excavation in all soils to full depth as may be directed with sand filling at bottom of the chamber for 10cm thick, concreting CC 1:5:10 using 40 mm guage HBGs jelly 10 cm thick and sode walls 9" thick brick work in cement mortar 1:5 using II class chamber burnt bricks of size 9" x 43/8" x 23/4" filling the size of foundation with excavated earth, plastering with cm 1:3 20m thick for inside and bottom and making necessary benching with brick jelly cement concrete to the required slope and fifnishing neatly etc., complete.
Inspection chamber of size 600 x 600 x 900mm Depth
Supplying laying and jointing of UPVC Pipe (Un-Plasticized Polyvinyl Chloride)(Schedule-80) pipes complete with necessary solvent cement weldable fittings, confirming to ASTM F-441 for water supply piping in the pumping system. The pipes shall be erected plumb in the risers. Erection of the above pipe including cutting, jointing of pipes with necessary fittings, erection of the pipes plumb to vertical, clamping the pipes on to MS Hot dip galvenized clamps, pressure testing of pipes, complete.. The pipes shall be laid burried Laying work to include excavating the necessary trenches,cutting and jointing and laying the pipes in the trenches.after laying and pressure testing of pipes, the excavated earth shall be back fill and compacted any excess shall be removed from site.
32mm dia UPVC
40mm dia UPVC
50mm dia UPVC
Supplying laying and jointing P.V.C pipes soil/ waste pipes (6Kg/SqCm) of approved quality and best variety conforming to I.S.S & with I.S.I mark, of the following sizes including cutting , Fixing to PVC specials using Adhesive but excluding cost of such specials and fixing to the pipes shall be duly laid at site, with necessary cutting & jointing of pipe with approved quality jointing lubricant. The pipes shall be fixed properly aligned and laid to slope. Before handing over, leak test shall be carried out and any defects found shall be rectified. Work shall also include necessary excavation and back filling 'with compaction etc, as directed by Engineer- Incharge (For sewer and Sullage line).
160mm dia Pipe
110mm dia Pipe
Supplying and fixing PVC RAIN WATER DOWNFALL PIPE of the following dia with necessary T.W.Clamps Plugs, Shoes,Bemds, other clamps, screws nails etc.,complete complying with standard specification. The rate is inclusive of cost of removable iron gratings of appropriate size. The size of Teak Wood plugs used is 150X25mm in front & 200x75mm in rear (wall side) with a depth of 110mm. The pipe is to be fixed by means of "U" clamps at the centre of pipes to be fixed.110mm dia PVC Pipe [4 Kg/SqCm]
160mm dia Pipe
Construction of Rain water Recharge well (1200mm dia) as per consultant drawing with necessary connections, Earth work-digging the well for recharge well supply and installation of Reinforced concrete Rings -4 feet OD & 1 feet Height 75 MM Thick - 20 no's supply and installation of einforced concrete slab 4 feet in dia. 200 mm thick, and 25 mm perforated 8 mm mild steel rods used for reinforcement-1" Perforated - 1no's supply and installation of Reinforced concrete closing slab 75 mm thick, 8 mm mild steel rods used for reinforcement with 600mm x 600mm Square HEAVY DUTY PERFORATED manhole cover Filtration Media Installation For recharge Well Unit 40 mm crushed stones-0.5cum, 20 mm crushed stones- 0.5cum, Brick Bats-0.5cum,fine sand 0.5 cub mtr Mixture of Brick Bats Shifting of excavated earth to the approved/authorised dumping yard as directed by the authorities/Site in charge. Drilling a bore well-200mm dia by high speed compressor-4MTRS, supply and installation of 110mm PVC PIPE PN-6-4 rmtr, 110mm PVC PIPE PN-6 Perforated with 10 mm Zigzag holes to easy percolate the water-4 mtr, 12mm Gravel Packing between bore well hole and PVC pipe and Inserting into the Bore Well- 4 mtrs. supply and installation of 180GSM Gio-fabric sheet to cover V-Wire screen, supply and installation of V WIRE SCREEN- 0.75 mm Slots. SS-304 Material -0.5 mtrs Height 6" diameter Shifting of excavated earth upto 1000mtrs as directed by site in charge (the well sholud be got approved by the concern department Engineer before use on works)
Supply and installation of equivalent approved make,For pumping the Domestice water from ug sump to OHT.Each Pumps shall deliver 15m3/hr @ head of 30mtr.,Skid mounted twin booster system with fixed speed system.1 working. of 5 HP Submersible Pump, with common galvanised delivery manifold.1no.s of gate valve and 1nos of non return valves.Control panel, Three phase preventer, with dry run control provision.
Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications
Drilling of 12" dia vertical borewell so as to have a finished size of 6" dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractor's rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. following references from SR-TWAD Board
Reaming from 200mm dia pilot bore to 350mm dia bore as direct by the Engineer incharge up to 60mtr depth ending below ground level
Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010
200mm dia CS
200mm dia RS
150mm dia RS
Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers.
150mm dia
200mm dia
Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock.
Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by 'V' notch method.
Supplying and using of bentonite powder for drilling bore well of 150mm dia to a depth of 75meters.
Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge.
Provision for the water diviner
Supplying and fixing Poly-propelene rungs of 25 mm square bar of size 260 x 170 mm for access way including anchorage in walls to a minimum depth of 100 mm with C.C 1:2:4 (one cement,two fine aggregate and four coarse aggregate) etc. complete and as directed by the Client / Engineer-in-charge.( Duct ,Shafts & UG sump,Over Head Tank and wherever necessary) Note: Rungs to be fixed before concreting and necessary provision to be made in the shuttering.etc complete, as directed by the Client / Engineer-in-charge.
FIRE FIGHRING ARRANGEMENTS
Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Equivalent)
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, erection, testing and commissioning Mono Block type Fire Fighting Pressurisation Pump of 180 LPM 110 metres head at 10 HP with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges., etc., complete as per standard specification and as directed by the Departmental Officers. (Make: Kirloskar / Equivalent)
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIARTAR / OMEX / EQUIVALENT.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply and kept in position of 9 litres capacity Fire Buckets of 4 Nos. with Bucket Stand as per standard specifications and as directed by the Departmental Officers
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Redpainting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.
150mm Dia
100mm Dia
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of following sizes to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
75mm Dia
100mm Dia
Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / EQUIVALENT.
Providing, fixing pipe supports from columns / wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening, arrangement design of hanger and should confirm with specification.
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.
Supply erection testing and commissioning of Electric Motor Driven Fire Pumpset suitable for automatic operation and consisting of following: a. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 4550 LPM against a total head of 110 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. 1 No. squirrel cage induction motor of 175 HP, 415 Volt, 3 phase 50Hz rating, conforming to IS:325-1978 with class "F" insulation, totally enclosed, IP 55 for enclosure fan cooled type conforming to relevant protection clause of IS 4691, synchronous speed of 2900 RPM. c. Common bed plate fabricated with MS channel / cast iron type for assembling the pump and motor flexible coupling between the pump and the motor with coupling guard for protection - 1 No. d. Making cement concrete foundation suitable for the above pumpset including vibration isolation pads as necessary, foundation bolts, brackets, clamp fixtures, grouting, etc., in accordance with the manufacturer's design and as per standard methods and including conveying, fixing and incidental charges, etc., complete as per standard Specification and as directed by the Departmental Officers.
Supply, installation, testing and commissioning of Diesel Engine Driven Main Fire Pump suitable for automatic operation and consisting of followings and complete in all respects as required. a. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 4550 LPM against a total head of 110 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. 190 BHP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant BS & IS standard complete. c. Auto starting mechanism, 12 volts / 24 volts electric starting equipment like self motor, dynamo, solenoid switches, etc. d. 110 litres capacity diesel tank mounted over stand fabricated using 25mm x 25mm x 6mm size MS angle providing with level indicator, inlet port, outlet port, drain port and diesel return line port and fuel pre-filter, after filter etc...............
e. Exhaust system having flexible metallic mufler, 100mm dia MS heavy pipe extended upto 1m outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residential silencer with necessary MS support arrangements from wall or ceiling as per site condition. f. Dash board consisting the instruments like Temperature Gauge, Galvano Type DC Ammeter, Lubricant Oil Pressure Gauge, Ignition Switch, Emergency Stop and all other protection equipment as per specification, stop soleneid for auto stop in the event of fault with audio indications, painted with Post Office Red Colour, etc., as required. g. 12V / 24V, storage battery, maintenance free tape, 180AH rating, MS fabricated common base plate, coupling guard, foundation bolts, etc., as required. h. Postioning the diesel engine driven fire pump over cement concrete foundation using suitable size antivibration mounting arrangement. All works including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KIRLOSKAR / EQUIVALENT.
Supplying, erection, testing and commissioning of Diesel Engine Pump Main Control Panel & Jockey Pump including necessary auto cut-in, cut-off and manual operations, battery charger switch arrangements, voltmeter, ammeter and running indication siren provision, wall mounting type, etc., as per the standard method and as directed by the Departmental Officers.
ELECTRICAL WORKS & HVAC Works
CT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars, internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., RYB indication lamps, internal wirings, Digital voltmeter and Ammeter and other required accessories for the complete operation as per the Tangedco requirements. Necessary approval to be obtained from Tangedco before procurement including all associated control wiring. 1set of 250/5A CT with TNEB metering provision and 1 nos of 250/5A CT for APFC.. 1no Earth Leakage Relay. For all items in this section, the rate includes necessary supports as required at site. No extra payment will be made for the same. Rate shall inclusive of factory witness test and all accessories, breakers , control wiring, models has to be followed as per in the technical specification. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
400A Isolator Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of 400A TPN MCCB panel, cubicle type, Free standing, floor mounted, single front, 14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors. The rate also includes labour charges and transportation charges etc. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Panel as directed by engineer-in charge/department superior engineers
Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steel made up of 2mm powder coated MCCB Indoor Type Three Phase Changer Over Main Panel with suitable to accommodate 400A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source 2nos of 400A 4Pole MCCB, 2nos of 250A 4Pole MCCB, 5nos of 160A 4Pole MCCB, 2nos of 125A 4Pole MCCB, 7nos of 100A 4Pole MCCB and 1no of 63A 4Pole MCCB's, compartment for as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 33x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The rate also includes labour charges and transportation charges etc. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
Diesel Generator set with AMF control panel
Supply, Erection, Testing and Commissioning of 250KVA Diesel Generator set with AMF control panel, Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specification comprising of Water cooled CPCB developing @ 1500 RPM and Alternator, complete with type approved canopy and all accessories. with the following technical specification: *Industries most reliable engines, proven over decades. *Low emission, High efficiency. *Compact, robust and rugged design. *Engine Dry type air cleaner *Exhaust Silencer (Residential type) Hospital Grade. *Expansion bellow *Lube oil cooler Lube oil filter (“Spin-on” type) *Fuel Filter (“Spin-on” type) *In line mono block fuel injection pump with Electronic Governor and fuel feed pump. *Dynamically balanced Flywheel with starter ring *Electronic Governor : Governing class G2 (as per ISO 8528 part V) *SAE 1 flywheel housing and flywheel suitable for SAE 14 disc coupling for close coupling of single bearing alternator.
*Exhaust gas turbocharger 24 Volt electric starter motor 24 Volt, 18 amps. Battery charging alternator *Engine instrument control panel consisting of: Engine safety module EMS (KG934) with built in On/Off Bush button. ALTERNATOR 250 KVA, Three phase 415V, 0.8 pf 4 wires 50 Hz at 1500 RPM brushless alternator. The voltage regulation will be 2 phase sensing +/¬ 1 %. The alternators shall be of Class H insulation, enclosure IP 23 and are designed built and tested to IS 4722 or any other equivalent Indian or international standards. Control Panel: 250 KVA DG Set AMF Control Panel Consisting of EMS KG934 unit consisting Volt, Amps, RPM, Hz, LLOP, HWT, Low fuel level, over Speed alarm, Over Load alarm, Load imbalance safety alarm, etc. Fuel Tank: 220-275 Letters Capacity inbuilt Battery: 24V DC, 130AH Supply of AMF Control Panel Suitable for 250 KVA DG set for EB Services with byepass arrangement. Exhaust Pipe: Supply and Fixing of Exhaust piping with MS pipe along the wall necessary supports, Flanges, Fasteners, Gaskets, etc (including Thermal insulation with Aluminium sheet wool, mesh,etc,Charges for laying of above Exhaust pipe & Cladding included and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
Bed Foundation with M30 Concrete:- Earth Work Excavation at length, width & depth of 20ft x 8ft x 8 ft (8 Cu.ft) and considate the soil at initial stage. Construction of single mat (with minimum of 6mm dia rod) and concrete the base structure at a depth of 1 feet & Height of 4feet using M30 grade concrete (for excavated length and breadth of 8 meter) in the excavated area. Along with this base mat extend with centering slabs for DG footing for 10 feet from the mat with suitable dimention (1 Cu.meter of foundation is exposed in the ground) considering the safe soil bearing capacity at site as 11 T / sq. mtr. and deposting on banks with initial lead of hard stiff clay stiff black cotton soil, hard red earth, shales, muram, gravel, stony earth and earth mixed with small boulders etc., as per SS 20B and as directed by departmental officers. Supply and fixing of foundation bolts with minimum of 1.25 Meter length manufactured from special steel along with necessary nuts, washers, anchor plates and templates with Erection of DG Set. ( Make: Kirlosker, Cummins or equvalent).
LIFT ( 13 Passenger) Supplying, erecting, testing and commissioning of machine room less passenger Elevator having 13 passengers capacity, rated speed 1.5 mtr. / sec., for GF,1st, 2nd, 3rd & Terrace floor 400 volt 3 phase, 50 Hz, AC variable voltage variable frequency derive with speed encoding, simplex full collective with / with out attendant, microprocessor based controller located top floor, variable frequency regenerative drive, flat polyurethane coated belts for traction media, stainless steel panels with hairline finish for car and door, gearless with permanent magnet motor located in the shaft top, all openings are located at the front of the hoist way, with centre opening Automatic with ACVVVF door operator with electronic door protective system, stainless steel hairline finish sliding doors, painted frame with down light false ceiling, Stainless Steel mirror finish hand rails, granite flooring of client choice, sixteen segment digital LED display position indicator in all floors, digital car position indicator, over load warning indicator, battery operated alarm bell and emergency light, fireman's switch at main lobby, with automatic rescue device, intercom between lift car and lobby and controller, voice synthesizer, 60 minutes fire rated car door. Car Entrance :- Clear opening and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
AC Panel -1 Supplying,erecting,connecting & commissioning FLOOR MOUNTED CUBICLE TYPE 14 SWG thick CRCA sheet compartmentalised modular type with powder coated SUB POWER PANEL.The Board shall be incorporated with the following:-INCOMER: 200 AMPS TPN MCCB With 25KA(Ics) Withstanding Capacity With adjustable Over load and Short circuit releases.OUTGOINGS : 160 AMPS FP MCCB with 16KA(Ics) Withstanding Capacity With both fixed Over load and Short circuit releases. … 9 Nos. 40 AMPS 4P MCB with 16KA(Ics) Withstanding Capacity With both fixed Over load and Short circuit releases. and Connected accessories etc.and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
AC Panel -2 Supplying,erecting,connecting & commissioning FLOOR MOUNTED CUBICLE TYPE 14 SWG thick CRCA sheet compartmentalised modular type with powder coated SUB POWER PANEL.The Board shall be incorporated with the following:-INCOMER: 200 AMPS TPN MCCB With 25KA(Ics) Withstanding Capacity With adjustable Over load and Short circuit releases.OUTGOINGS : 160 AMPS FP MCCB with 16KA(Ics) Withstanding Capacity With both fixed Over load and Short circuit releases. … 6 Nos. 40 AMPS 4P MCB with 16KA(Ics) Withstanding Capacity With both fixed Over load and Short circuit releases. and Connected accessories etc., and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
LIGHTING PANEL Supply and erection of 160 Amps capacity floor mounting / wall mounting panel board (Cubical type) with bus bar chamber made up of 14/16 SWG MS sheet for 3 phase 4 wire system with 25mm x 3mm tin coated copper flats for phases and neutral; cable chamber, switch chamber and with 2 Nos. 25mmx3mm tinned copper flat for the earth bus on the rear side of the panel board; necessary interconnections by copper flat of suitable sizes; suitable PVC colour sleeves for the interconnecting copper flats / rigid copper wire; earth connections to all swithces / bus bar by copper flats of suitable sizes from the earth bus; hylam sheet separation between bus bar and swithces; 1set LED pilot lamps with switches, fuse units, suitable angle iron frame size of 40mmx 40mmx 6mm with powder coated painting over one coat of red primer and with numbering; superscription of cables sizes, capacity of switches etc and incorporating the following:Incoming: 1 no.100A TPN 15KA MCCB with all protective devices.Bus capcity 3phase 4wire 100 A Aluminium bus Outgoings: 5 No. 63A TPN 16KA MCCB & 1 No. 32A TPN 16KA MCCB with all protective devices and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,
POWER PANEL Supply and erection of 125 Amps capacity floor mounting / wall mounting panel board (Cubical type) with bus bar chamber made up of 14/16 SWG MS sheet for 3 phase 4 wire system with 25mm x 3mm tin coated copper flats for phases and neutral; cable chamber, switch chamber and with 2 Nos. 25mmx3mm tinned copper flat for the earth bus on the rear side of the panel board; necessary interconnections by copper flat of suitable sizes; suitable PVC colour sleeves for the interconnecting copper flats / rigid copper wire; earth connections to all swithces / bus bar by copper flats of suitable sizes from the earth bus; hylam sheet separation between bus bar and swithces; 1set LED pilot lamps with switches, fuse units, suitable angle iron frame size of 40mmx 40mmx 6mm with powder coated painting over one coat of red primer and with numbering; superscription of cables sizes, capacity of switches etc and incorporating the following:Incoming: 1 no.100A TPN 15KA MCCB with all protective devices.Bus capcity 3phase 4wire 100 A Aluminium bus Outgoings: 3 No. 63A TPN 16KA MCCB & 3 No. 40A TPN 16KA MCCB with all protective devices and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.
VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixing of 12 way vertical TPMCB and neutral MCB sheet steel enclosure distribution board with double door (metal) TPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with 1 No. of 100A FP MCB as Incoming and 12 Nos.of 32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.
Supply and fixing of 7 segment 6 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 6 ways in each segment) and seperate provision for MCB / Isolators ( totally 18 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35sq.mm. with the following on wall with earth connection only.
VERTICAL THREE PHASE INDOOR DISTRIBUTION BOARD WITH MCB : Supply and fixing of 4 way vertical TPMCB sheet steel TPMCB DB with IP42 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 1 No.of 63A,10KA Triple Pole MCB and. 09Nos of 6A to 10A SP MCB for Outgoing in Flush with wall and making good of the concealed portion with earth connection. (TPMCB DB with IP54 Protections)
Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 32Amps DP MCB.1 no and 6 nos. 16A SP MCB as outgoing Concealed in flush with wall with earth connection only. IP42 Protection. Higher End.
Indoor / Outdoor Lights
Supply and fixing of 40W Spot Light LED fittings recessed mounted accent lighting luminaire with die cast aluminium heat sink and sand graind finishing reflector with DALI dimmable driver. and narrow, medium and wide beam optics with CCT option of 3000K to 5000K. Housing colour optionof white and black. The light fitting connected with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete. ( Make : Philips or Equivalent )
Supply and Fixing of 40w LED Round type Surface mounted Down light fitting with LED (Higher End) and a Correlated Color Temperature of 4000K, providing a bright and natural white light. on ceiling with suitable support from ceiling with hanging chain link support with coches screws mounting the fitting on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting. ( Reputed Make like : Crompton Proxima-ll 40W Natural White Indoor Lighting, CDR-216-40-40-SL-NWH )
supply, installation, and fixing of 6meter free-standing, single-arm bracket street lighting system. The system is built around an GI STEEL TUBULAR POLE FOR STREET Light. The pole specifications include a bottom diameter of 114.30mm and pole thickness of 3.65mm, and Length 6000mm. it is fitted with a 250mm x 250mm x 6mm base plate. The associated civil works include all necessary concreting and masonry for securing the post,The electrical components feature a high-end 48W LED street light fitting, a high-end 6A Single Pole MCB, Street Light SMC Box with 2/4 way terminal connector with 3R x1.0 sq.mm. FRLS PVC unsheathed copper wiring for terminal to LED fitting , and a complete foundation kit with J-bolts and nuts for a secure installation.
supply, installation, and fixing of 6meter free-standing, Double-arm bracket street lighting system. The system is built around an GI STEEL TUBULAR POLE FOR STREET Light. The pole specifications include a bottom diameter of 114.30mm and pole thickness of 3.65mm, and Length 6000mm. it is fitted with a 250mm x 250mm x 6mm base plate. The associated civil works include all necessary concreting and masonry for securing the post,The electrical components feature a high-end 2 nos of 48W LED street light fitting, a high-end 6A Single Pole MCB, Street Light SMC Box with 2/4 way terminal connector with 3R x1.0 sq.mm. FRLS PVC unsheathed copper wiring for terminal to LED fitting , and a complete foundation kit with J-bolts and nuts for a secure installation
Supply and fixing of 100W LED FLOOD LIGHT FITTING (High Bay Light) with cool day light suitable for wall / roof sheet mounting, made out CRCA powder coated body,IP65 aluminium reflectors, poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.
Supply, Installation, Testing & Commissioning of 40W LED Gate Light Fitting. The Light Fitting should be powder coated with high pressure die-cast aluminium LED housing. And the LED fixed on die-cast aluminium heat sink for proper thermal management. and the operating voltage range 140 – 270V AC, provided with open and short circuit protection and input surge voltage protection. Decorative post top for 360 degree Indirect light with IP 65 protection, Resistant to impact and corrosion. Glare-free and better uniformity. MAPLE LPTO-40-CDL/M make :Crompton Features and details Aesthetically designed and soft illumination effectiveness : 2450 lm power : 40W colour : multi colour Included components : post Top Rate shall inclusive of necessary joint kit,glands,etc for loop in/out connection suitable to outdoor application. Crompton CAT REF : - LPTO-40-WW-M Equivalent.
Supply and fixing of 36W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Supply and Fixing of 40W 4' LED Tube Light with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of pressure die cast aluminium housing Bulk Head 9W LED fitting with IP65 protected with PVC unsheathed copper leads from terminals to the fitting.
Supply and fixing of Floor mount LED Step Light for Outdoor 6W LED Light fitting ( BED Lamp)(IP67) fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. model equivalent to Crompton LSL-6-CDL(Make:Philips/ Crompton/ Havells)
Supply and fixing of Mirror Light 20W LED Batten with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Make:Philips/ Klite/ Havells)
Supply, Installaion, Testing and Commissioning of Inspired from the deep roots of Bohemia, Monarc is an amalgation of classical Indian grandeur along with elegant Bohemian crystal design. The Monarc of 12 Lamps E14 Chandelier Light with accessories . ( Make Havelles, Klite )
Supply and Fixing of Cove LED Light (10W) Flex Strip Trica AC Tri color LED (1Roll - 50m) model on floor or Ceiling with Flex strip Power cord and Aluminium Profile Mounting accessories ( IP65 ) Complete etc,. (Make :Philips /Crompton/Havelle
Supply and installation of LED multi coloured serial lights concealed in a moulded housing of thicknes 2mm suitable for outdoor hanging.The serial lights shall be having Light Modes: Constant Bright, Flicker, Wavy, Fast and Slow Flash. The Led serial lights shall be internally connected and the connecting straps for a proper conjuction of the single profile. The rate is inclusive of the power cables, drivers, 12V SMPS, IR Controller with connecting wires with required taping, cartage & labour charges.
Supply, fixing, testing & commissioning of 11W Bollard with concrete pedestal luminaire designed for surface mounted. Symmetrical light distribution. Luminaire made of square extruded aluminium tube (grade 6063) with pressure die cast aluminium components of high corrosion resistance and non corrosive stainless steel fasteners. Clear polycarbonate diffuser. Pressure die cast aluminium mounting plate 121 square x 4mm thick with 3 elongated holes 15 x 10 to suit M8 bolts at PCD 70 with pure polyester powder coating.The base plate have a cable entry hole of 30mm dia at the center. This mounting plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed foundation. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 4-6KV. Luminaire dimension : 121mm square x 970mm height.
Supply and fixing of 1200mm (48") sweep AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod with fan clamp with side plates and cross arm of size 450mm (18") (Higher end) and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessary accessories and hardware's as required.
Supply and fixing of 375mm(15")sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessary accessories and hardware's as required
Supply and Fixing of louvers shutters arragements for 375mm (15") sweep ( Heavy duty ) AC Exhaust fan
Supply and fixing of 1500W automatic electric water heater of 35 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire, but without plumbing work
Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required.
Supply and laying of 31/2 core 300 Sq.mm PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Laying of 3 1/2 x 240 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good
Supply and Laying of 3 1/2 x 150 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good
Supply and Laying of 3 1/2 x 120 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good
Supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Laying of 3 1/2 x 35 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good
Supply and Laying of 4C x 16 sq.mm. PVC armoured LTUG aluminium cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Clamping of following XLPE armoured LTUG cable in a Ceiling / wall with suitable clamping etc as required.
Supply and Clamping of 3 1/2 core x 240 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 3 1/2 core x 150 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable
Supply and Clamping of 3 1/2 core x 120 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 3 1/2 core x 50 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 3 1/2 core x 35 Sq.mm PVC armoured LTUG aluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 4 core x 16 Sq.mm PVC armoured LTUG Aluminum cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and Clamping of 4 core x 6 Sq.mm PVC armoured LTUG Copper cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable.
Supply and fixing of double compression brass cable gland for following Aluminium conductor XLPE insulated armoured cable of 1100 V grade with earth connection.
Supply and fixing of brass cable gland for 3.5C x 300 sqmm aluminium cable LTUG cable with earth connection.
Supply and fixing of brass cable gland for 3.5C x 240 sqmm aluminium cable LTUG cable with earth connection.
Supply and fixing of brass cable gland for 31/2C x 150 sq.mm PVC LTUG armoured cable with earth connection with necessary accessories etc
Supply and fixing of brass cable gland for 31/2C x 120 sq.mm PVC LTUG armoured cable with earth connection with necessary accessories etc
Supply and fixing of brass cable gland for 31/2C x 50 sq.mm PVC LTUG armoured cable with earth connection with necessary accessories etc
Supply and fixing of brass cable gland for 31/2C x 35 sq.mm PVC LTUG armoured cable with earth connection with necessary accessories etc
Supply and fixing of brass cable gland suitable for 4C x 16 PVC armoured LTUG cable with earth connection.
Supply and fixing of brass cable gland for 4C x 6 sqmm COPPER cable LTUG cable with earth connection.
Supply and providing cable end termination of the following size PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable)
Supply and providing cable end termination of 3 1/2 Core x 300 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 3 1/2 Core x 240 Sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete.
Supply and providing cable end termination of 3-1/2x150 sq.mm.PVC LT UG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and providing cable end termination of 31/2 C x 120sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete.
Supply and providing cable end termination of 3-1/2x50 sq.mm.PVC LT UG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and providing cable end termination of 3-1/2x35 sq.mm.PVC LT UG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete
Supply and providing cable end termination of 4C x 6 sq.mm PVC LTUG Copper armoured cable with necessary Copper cable sockets by crimping with electrical connection complete.(SOR-2025-26) (SD-223)
Supply and Run of 3 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 4 sq.mm copper wire and making good of the concealed position. (SD 352 )
Supply and Run of 2 Run x 2.5 sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe on wall and ceiling and 1R of 1.5sq sqmm continuous earth wire connection with painting of suitable colour. ( SD -348 )
Supply and run of 2 of 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in rigid pipe concealed in wall and ceiling with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour( SD 55)
Light / Fan Points
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5points / Coil) Higher End (SD-289)
Wiring with 2 x 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 1 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for PVC concealed light (6 points per coil) (for rooms like bath, toilet & pumproom, etc.). (SD-26)
Lift Shaft Wiring : Wiring, Connecting, Testing & Commissioning for lift well light point and 6Amps power socket outlet for all 4 floors with 2 x 2.5 sqmm FRLS PVC insulated stranded copper conductor of 1100V grade along with 1 x 2.5 sqmm FRLS PVC insulated standed copper conductor cable as earth wire in MS conduit including providing and fixing switch box, 2 Nos. of 5A single way module switch (for controlling light point and socket Outlet ) for each floor of the lift well , with bulkhead lamp 1 No. 5A 5 Pin shuttered socket outlet with flush type switch for each floor of the lift well and making necessary connections complete etc. ( 6 points)
Wiring with 3R x1.5 sq.mm. (22/0.3) PVC insulated unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate with continuous earth wire connection of 1 run of 2.5 Sq.mm wire and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End (SD-309)
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-319)
Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil) Higher End (SD-328)
SWITCH & SOCKETs
Supply and fixing of 20A Flush type Wall Socket 32A DPMCB complete set for AC Plug in flush with wall with earth connection. ( For AC Plug ) (SD 144)
Supply and fixing of 1 no.6A two module 3pin socket , 1 no. 6A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) in flush with wall wall with connections. Higher End (SD 378 )
Supply and fixing of 2 nos.6A two module 3 pin socket , 2 nos. 6A one module switch on suitable module surface mounting Box ( GI ) with module cover plate (plastic) in flush with wall with connections. Higher End. (SD 384 )
Supply and fixing of 3 nos.6A two module 3 pin socket , 3 nos. 6A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) in flush with wall with connections. Higher End (SD-390)
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box ( Plastic ) with module cover plate (plastic) in flush with wall with connections. Higher End.- (SD 402)
EARTHING SYSTEM
Supply and Installation maintenance free GI Earthing System comparing of 17.5 mm dia and 3 mtr long earth electrode of low carbon steel rod based environment friendly back fill compound and suitable clamp. (SR 2025-26,pg-282,M-2568)
Supply, Installation, Testing and Commissioning of earthing station consisting of 600 x 600 x 3 mm. thick, copper Plate earth electrode, back filling with alternate layer of charcoal, salt, brick masonry work for chamber 450 x 450 mm. heavy duty CI cover, watering pipe, funnel and earthing conductor as per IS:3043 specification. All civil works required such as excavation in all types of soils, rocks, PCC Earthing Chamber foundation, reinstatement and making good the surface to match original, removal of surplus earth etc. are included.(Rate as per Quotation)
Coil earth to street light poles with No.8 SWG GI wire of 11.5 metres of length in which 10 metres of total length compressed in to a coil of one meter length (75mm to 100mm dia) connected suitable with hexagonal earth bolt of size 8mm in to 25mm welded on the pole at one end with a coil position fixed on the earth. ( SD 78)
Supply, fabrication, of GI /Copper earth flat of following size in provided trench, clamping in wall, ceiling, with suitable Clamps/ saddles, connecting the joints through bracing / welding covering with termination in the earth pits, Panels, Distribution boards and equipments with bitumen paint including accessories wooden plugs, screws, fastener etc., all inclusive
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection (SD-76)
Supply and run of 25mm x 6mm GI flat with necessary clamps / supports on wall / floor / ground for earth connection.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection (SD -372)
Supply and Run of 1 of No.8 SWG GI wire in suitable PVC rigid pipe on wall / floor / ground for earth connection (SD -373)
EV CHARGING
LV PANELS-250A MCCB ENCLOSURE PANEL,Supply, Installation,Testing and Commissioning of cubicle type wall mounting outdoor type switch board comprising of the following, the board shall be fabricated as per the detailed specifications. Incomer-630 Amps FP 36KA Manualy operated fixed type MCCB with OL and SC Thermal magnetic releases with spreaders and front operated rotary handle mecahnism, door interlock ,shunt release for tripping and all other required necessary accessories - 1No. Instruments Panel for outgoings,Digital Multi function meter R,Y,B and ON / TRIP indicating lamps, CTs, Control fuses/MCBs, etc. as per the specification.
The panels are provided with Supporting rigid steel framework.Cubicle type, 14 / 16 gauge CRCA sheet steel enclosed.Complete with interconnections and distribution bus bars.Proper bonding to earth.Painting/lettering on Breakers and distribution boards and its circuit diagram.Degree of protection for distribution panel enclosure is as per IS:13947-1993.All MCCB’s are provided with extended operating mechanism for door interlock and spreader terminals for cable connectivity.Every MCCB is provided with one set of aux contacts duly wired and brought to the terminals for BMS connectivity.Current density for aluminium bus bars considered 0.8 amps for 1 sq.mm of rated current of bus bars and for copper bus bars 1.0 amps for 1 sq.mm of rated current of bus bars.Main earth bus bar is provided through out the length of each board.All Meters are digital electronic (LED Type) of approved make with RS485 port and have compatability for BMS.All hinged door are earthed through 2.5 sq mm tinned braided copper wire.Pad locking of Switch board doors.Pad locking of MCCB’s handles in “OFF” Position and Labour charges ,Transportation Charges, Including Loading and Unloading Charges etc.,[ Rate as per Quotation)
Supply and Installation of MS flat / angles / channels supports of various sizes including cable tray,cutting, welding, grinding, fixing accessories and one coat of primer & two coats of enamel paints, minor civil works like grouting existing floors and walls etc. as required. [QUOTATION]
The cable rack shall have runners rugs of suitable size, horizontal elbow, vertical elbow 90 Deg. Up vertical elbow 90 Deg. Down, re-deep, coupler plates, materials. The cable racks shall be suspended from ceiling supported from side walls in columns etc. with adequate size supporting angles / channels with fastners, welding, anchor bolts, nuts etc. The rack shall have suitable cable clamping arrangements etc., Cable Tray /ladder should be powder quoted as match with ceiling colour as per PWD requirements. The rate shall inclusive of necessary Wedge anchors theaded rods,nuts & bolts, making clamp for rcc roof fix / perlin/Truss, cable tray clamps etc, (8 mm threaded rod supports shall be provided at not more than 2 mtr center to center and as per site requirement )
Perforated type Supply and fixing of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 600mm width and 50mm height (Rate as per Quotation)
Ladder type Supply and fixing of GI Hot Dip / Powder Coated 16 SWG Ladder Type Cable Tray with 600mm width and 75mm height (Rate as per Quotation)
Perforated type Supply and fixing of GI Hot Dip / Powder Coated 16 SWG Cable Tray with 300 mm width and 50mm height
Ladder type Supply and fixing of GI Hot Dip / Powder Coated 16 SWG Ladder Type Cable Tray with 300mm width and 50mm height
Supplying and fabricating of MS structural steel supports for various applications using U channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above.
Lightning Protection System
Air termination rod 16/ 10 mm ( Lightning rod) - 4mtrs (PWD SR2025-26, pg no:283 , M-2563)
TEST LINK Supply of Test Link Box for each Down conductor in order to disconnect the earth termination system to enable measurement of resistance (PWD SR2025-26, pg no:283 , M-2565)
Supply and installation maintenance free GI Earthing System comprising of 50mm dia and 2 mtr. long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs. of carbon based environment friendly backfill compound and suitable clamp (PWD SR2025-26, pg no:283 , M-2568)
SURGE PROTECTION Supply and installation Cabinet Type Class 1 and 2 Combined Model SPD to arrest surges and overvoltages in the power line due to lightning switching action etc. they must be installed in the incoming MCC panel / DB of the respective building in parallel to the power circuit. Model: PSV4-12.5/250TT (3 phase power network) (PWD SR2025-26, pg no:283 , M-2570)
Telephone lines
Supply and fixing of telephone socket (telephone jack single line RJ 11) on suitable factory made metal box (necessed) with frame and face cover plate etc., complete required with connections
Supply and Clamping of armoured co-axial cable for TV (RG-06) in suitable PVC Pipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete.
Supply & fixing of TV socket (coaxial jack) on suitable factory made metal box (recessed) with frame and face cover plate etc., complete required with connections. (Rate as per quotation)
Fire Safety
First Aid Box complete with all First Aid Medicines( S.R.2025-26, P.No:251, Item no: M-1977)
Shock Treatment Chart fixed in glass frame ( S.R.2025-26, P.No:251, Item no: M-1978)
Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms ( S.R.2025-26, P.No:251, Item no: M-1982)
Metallic Danger Board as required by the Electrical Authorities ( S.R.2025-26, P.No:251, Item no: M-1981)
2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS (M-1976) (5 set) ( S.R.2025-26, P.No:251, Item no: M-1976)
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT ( S.R.2025-26, P.No:155, Item no: M-0851)
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT /SAFETY FIRST / EQUIVALEN ( S.R.2025-26, P.No:155, Item no: M-0852)
Fire Alaram
Supply, installation, testing and commissioning of Micro Processor based conventional 4 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply ,consisting 230/24 volt SMPS unit, 2Nos.of 12 volt 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.(SR-2025-26, pg-134, M-0769)
Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard method sand as directed by the Departmental Officers.(Make: Ravel / Equivalent) (SR-2025-26, pg-134, M-0771)
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers (Make: Ravel / Equivalent) (SR-2025-26, pg-134, M-0772)
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. (SR-2025-26, pg-134, M-0773)
CCTV System
Supply, Installation, Testing and commissioning of 40 channel 4 SATA NVR, with 8TB Hard Disk Drive 4 nos, with HDMI Cable up to 20 mtr New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected, Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output HDMI1 / VGA1 outputs provided HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 8 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback.Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Prama/ cp plus)
Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification: ●1/2.5" Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection) ● Face Detection ● BLC/3D DNR/ROI, IP67 complied ●On-board Storage - Built-in micro SD/SDHC/SDXC card slot, up to 128 GB, ● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W ● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. (Make : Hikvision / Dahua / Prama/ cp plus)
Supply and Installation of 2MP PTZ IP Camera 360 Degree, 150m IR, IP66, Built in Mic and Heater High resolution and sensittivity of 1 lux at F1.8 30IRE with 4.8 ~ 96 mm (optical 20x) & 16x Digital Zoom, Auto (ICR) / Color / B/W, Electronic Image Stabilization, Alarm in&out, Audio Support, Motion Detection, Network Loss detection, SD Card Support, IP66 and Vandal Proof IK10, receiver, driver, endless Pan/ 90Tilt and necessay mounting support / bracket, accessories as required for outdoor installation with ONVIF Compliant, Certified high Strength Metal Housing with POE support. Camera Power supply will be taken from Ethernet cable. (Suitable for 150mtrs coverage distance)
Supply, Installation, Testing and Commissioning of 55" smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS pannel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANR h) True colour generator i) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remote p) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). (As per quotation)
Supply and fixing of outdoor 4X6 PVC box with 102mm x 77mm x 102mm with all fixing accessories. IP 66 (As per quotation)
Supply and Clamping of CAT 6 armoured cable in suitable PVC Pipe 1" thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem) i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal) IEEE 802.3 : 10Base-T; 100Base-T; 630Base-T IEEE 802.5 16 MB; ISDN; TPDDI; ATM ii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. Fire Rating: PVC : IEC 60332-1. iii. Conductor - Bare Copper Wire iv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm.
Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges.
Supply and fixing of POE 24 port switch 10/ 100 / 630 Base -T / 2 x 630Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line.
Supply and fixing of POE 8 port switch 10/ 100 / 630 Base -T / 2 x 630Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK)
Supply and fixing of Heavy duty MS Powder coated made of Out Door Weather Proof Box 2Ft x 2Ft with Air Ventilation with 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch with 600VA UPS with 1Hour back up, with High voltage cutoff , Low voltage cutoff , Smart time delay , Overload protection , Short circuit protection, Spike protection, improved transformerand suitable bracket fixing in camera pole or wall.
Supply ofHeavy duty MS Powder coated made of Out Door Weather Proof Box 2Ft x 2Ft with Air Ventilation with Clamping and Accessoris(As per quotation)
Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch on suitable module Surface mounting Box ( Plastic ) with module cover plate (plastic) on wall with connections. Higher End. (SD 386/2025-26)
600VA UPS system with 1Hour inbuilt back up battery, with High voltage cutoff , Low voltage cutoff , Smart time delay , Overload protection , Short circuit protection, Spike protection, improved transformer,Sor 2025-26 (M-3087 Pg No.302)
Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour.(SD 347/2025-26)
Supply and fixing of 6m Length pole with base plate of size 250x250x6mm as per IS-875 with following specification. Pole Outer die -76.10mm x 3.65mm Thick x 6 meter. The rate also includes Concreting and masonary work for fixing the post.
Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up
Supply and Fixing of Rack with Accessories -Higher end 36U Rack and fan extra for the above rack.
Public Address System
Supply and Installation of 15 watts indoor Wall Speaker with Line Matching Transformer in the existing pole with supporting clamp Model:- Specification:- 1.Input Power : 15W RMS/20W Max 3. Frequency : 250-10,000Hz 4. SPL : 108dB/1W/1m,122dB/25W/1m at 1kHz 5. Power Taps : 40/30/20/10/5W (Make: Ahuja, Bose, Yamaha or equivalent) (Make: Ahuja AMH402T/Bosch or its equivalent) (SR-2025 - 26, M-2152, P-260)
Supply, Installation, Testing & commissioning of 480 watts P.A Mixer Amplifier with the output power of 1350 watts maximum, 750watt rms at 10% Thyristor harmonic distortion(THD), 1000watt RMS at 5% THD, 1000 watts RMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1500watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of 2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the input channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make: Ahuja SSA 10000 /Bosch or its equivalent) (SOR 2025-26)
Supply, Installation, Testing & commissioning of 240 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 watts RMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 630watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of 2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the input channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. (Make: Ahuja SSA 6300 /Bosch or its equivalent) (SR-2025 - 26, M-2150, P-259)
Supply, Installation, Testing & Commissioning of 10" gooseneck with suitable base incorporates separate bush switches for momentary and dynamic microphone with 600ohm impedance and has 2.5mv/pa sensitivity and frequency response ranging from 50-15000hz with multi tone chime model. (Make:-ACM66 Ahuja/Bosch/its equivalent) (Rate as per quotation)
Supply and run of Armoured Speaker Cable 2 core 2.5 sqmm PVC insulated SC unsheathed of 1100V Grade in suitable PVC conduit pipe on concealed wall and ceiling with painting of suitable colour.
Supply and fixing of custom built M.S Powder coated wall mounting 42U Audio rack and fan extra for the above rack with Lock & key for housing of Amplifier & player/Recorder conforms to EIA-310,IEC-60297 and able to withstand the load of 40kg with welded construction made up of CRCA steel with suitable height, width and depth. (SOR 2025-26)
Supply, Installation, Testing & Commissioning of Cordless mic UHF model. (Make:-ACM66 Ahuja/Bosch/its equivalent)
Split AC Unit / HVAC WORKS
Supply and erection, testing and commissioning of 1.5 TR (4500 K.cal/hr) ABS Split type Air conditioner ( 5 star rating) confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted with hermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZ single phase AC supply inverter technology with capable of the following performing a) Cooling b) Dehumidifying. c) Air circulating d) Filtering e) Refrigerant pipe lines – 6 mtr length The installation works for the above split type AC units include the following 1. Mounting / fitting indoor and outdoor units with Suitable MS Stand for Outdoor Unit at their respective locations. 2. Laying refrigerant pipe line of required length not exceeding 6 meters distance & connecting both units after drilling hole/holes in the wall is required, thickness of the copper tubing shall not be less than 0.7 mm. 3. Installing the section pipe with expanded polythene foam tubing. 4. Laying drain pipe to throw out the condensate water being formed within indoor unit. 5. Leak testing the entire system unit. 6. Charging refrigerant gas in the unit. 7. Suitable electrical wiring with to be provided with 2.5 sq.mm PVC insulated copper wire between indoor and outdoor unit upto 6 meter length and upto switch within 3 meters of location of indoor unit. (Like (Carrier / Voltas / Blue Star / Equivalent) as directed by the department officers
Supply and fixing of 4 KVA capacity Automatic Voltage Stabilizer with time delay relay (V Guard make ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 1.5 split AC with necessary inter connection and earth connection as directed by the departmental officers.
Supply, Installation, Testing, Commissioning and handing over of 11 TR Aircooled self contained ceiling mounted ductable AC units. (SR2025-2026, Pg -252, unique Code : M-1995)
Supplying and Installation of 16 SWG copper tube of following sizes including cutting, bending, jointing, brazing etc. as per specifications.
Supply and fixing of Copper Refrigerant Piping of 7/8" dia
Supply and fixing of Copper Refrigerant Piping of 5/8" dia
Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines.
Supply and Filling of Refrigerant gas R410A
Fabrication,Supply,Erection and testing GI ducting of 22 Gauge thickness.
Supply , Fabrication and erection of fabricated ducting made up of GI sheets of 24 Gauage Thickness.
Supply and providing thermal insulation of 9mm thick vidoflex with Aluminum Foil
Supply and providing acoustic for initial portion of ducting with 12mm thick Fibre Glass Rigid Board covered with Tissue Paper and Aluminum Perforated Sheet
Supply and fixing of extruded aluminum powder coated, Supply and return Air Grilles / Diffusers with Volume Control Damper
Supply and fixing of Flexible Canvas Connection
Supply and fixing of water drain pipe line (1” PVC Pipe)
Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Oudoor Unit
Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Indoor Unit .
Supply and fixing of Duct Mouth Dampers.
Supply and providing civil Concrete Block for Mounting the AC unit
Supply and Filling of R-22Refrigerant gas
Supply and fixing of Thread rod, Support angle Channel and Nut and Washers.
Supply and Fixing of Scoffolding ( steel pipes ) Connected accessories such as swing, shackles, couplers, clamps, putlogs and ladder etc.,
Pressure Testing ,Vaccuuming, Unit Positioning,Transportation, Loading, unloading, Lifting, shifting of Equipments and Materials
Supply and Run of 4 of 10 sq.mm. (84/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour
Supply and fixing of 32A FP sheet enclosure with 32A FP MCB in flush with wall with earth connection.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.22 MB
Cover_2.pdf
Additional Documents • 1.31 MB
Cover_1.pdf
Tender Documents • 0.38 MB
BOQ_788454.xls
BOQ • 0.71 MB
Download all tender documents and submit your bid