Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC 5 A KALPANA NAGAR 7TH CROSSING MORAR GWALIOR MP | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹39.4 L+₹10.5 L (36.4%)Rejected-AOC 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹39.8 L+₹10.9 L (37.5%)Rejected-AOC MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹40.0 L+₹11.0 L (38.2%)Rejected-AOC 123 B CENTRAL AVENUE SAINIK FARMS NEW DELHI 110062 | NEW DELHI | NEW DELHI | DELHI | 110062 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹41.0 L+₹12.1 L (41.7%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
5 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE JHANSI
HQ CWE JHANSI
REPAIR AND MAINTENANCE OF 33/11 KV MRS AND CONNECTED WORKS AT MORAR CANTT UNDER GE GWALIOR
2020_MES_376574_1
CWE/JHA/GWL/60 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE GWALIOR
₹80,000
Yes
30 Dec 2020
11 Sept 2020
10 Oct 2020
11 Sept 2020
5 Oct 2020
30 Sept 2020
60 days
Amount
Excavation in trenches n exc. 1.5 m wide and n exc 1.5m deep for foundation, etc. or for shafts, wells cesspits, manholes, pier holes,etc.n exc.10 sq m on plan and n' exc. 1.5 m in depth and getting out in soft/loose soil complete all as specified.
Excavation in trenches n exc. 1.5 m wide and exc 1.5m deep and n.exc 3.0 m deep for foundation ,etc. or for shafts, wells cesspits, manholes, pier holes, etc. n exc.10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in ,including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick in soil complete all as specified and directed.
Removing excavated material (soil) to a distance n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for sand cushioning with layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded BT stone aggregate as in bed block for hold fast or coping including necessary form work complete all as specified and directed.
M&L for laying precast concrete cable cover, class HV, Type 1 of size 300mmx180mmx40mm complete all as specified and directed.
S&F tube 'Light' grade galvanised with all fitting laid in trenches, fixed to wall and floor of 100mm dia for cable protection complete all as specified and directed.
Dismantling steel/PCC pole any size and removing from site complete all as directed.
M&L, Steel tublar swaged poles, complete with cast iron base plate, finials taper plug bolts, nuts & screws as specified type 410 SP-55 (11.00 mtr long) complete all as directed. Note : Earth work and PCC shall be measured & paid separately under respective items .
Dismantling of cross- arms, clamps, danger plate of MS channel or angle sections etc.and removing from site complete all as specified and directed.
M&L ,mild steel work (structural) as in cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers , welding, bending, drilling holes for bolts, in any size or shape as indicated or directed and inclusive of one primer coat with red oxide primer, one under coat & one finishing coat of aluminium paint complete all as specified and directed.
Dismantling insulators any type, any size.complete all as specified and directed.
Supply and fixing disc type insulator porcelain, vitreous, brown with ball socket and tensioning clamps 2U type for 33 KV complete all as specified and directed.
Supply and fixing pin type porcelain, vitreous, brown insulator for 33 KV including one galvanised MS spindle with washer, nut and bolts complete all as specified and directed.
S&F, pin type, porcelain, vitreous ,white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm hieght & 150 mm dia for 11000 volts grade complete all as specified and directed.
S&F in repair Bymatelic connector suitable for 33/11 KV CT/PT all as specified and directed.
M&L for wrapping 3 band of radium strips of 45mm width of approved colour each (made of HIP retro reflective radium sheet) all around HT 33/11 KV Steel tubular pole ( height from foundation as approved ) complete all as specified and directed.
M&L for lightening arresters expulsion type for 11 KV complete with all fittings 30 Kilo amp discharge capacity distribution capacity , distribution class complete all as directed.
M&L, earthing complete with GI earth plate electrode 60cm x 60cmx 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with the top edge of the earth plate not less than 1.5 metre below normal ground level connected to GI earth strip 32 x6 mm by means of brass bolts ,nuts, check nuts and washers of galvanized iron steel all as shown in electrical plate No.3 of MES Schedule parts-I 2009 .and including excavation & earth work in any type of soil , disposal of soil , providing charcoal dust and common salt upto top edge of earth plate, construction of PCC pit in mix 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 as in cover slab, reinforced with 6 mm dia MS bars 3 Nos. both ways with lift hook made out of 6mm dia bar, watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 15mm dia light grade pipe for earth lead protection upto 7.50m length (beyond 7.5 m length will be measured and paid separately) and testing on completion, complete all as specified and directed.
M&L, earth continuity conductor or main earthing lead 32X6 mm galvanized iron strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
Dismantling of unservisable HT cable of any size from pole trench etc complete all as specified and directed.
Supplying, laying, jointing & testing 95 sqmm 3 core XLPE insulated & PVC sheathed armoured earthed HT cable, 11000 volts grade heavy duty with aluminium conductor laid in trenches/pipe/fixed on the wall etc .complete all as specified and directed.
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed.
Supply and install in replacement HT 11 KV outdoor type gang operated air break switch in repair suitable for horizontal or verticle mounting rotating type complete with 12 insulator of rating upto 400 Amps complete all as specified and directed.
S & F in repair heat shrink end termination outdoor type Cable jointing kit for 11KV HT XLPE cable of size 95 to 120 Sqmm 3 core complete with jointing material and accessories.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size, for HT of size 25x20cm size complete all as specified and directed.
Disconnecting 33 KV incoming and outgoing connections of VCB of any description and any make of rating 33 KV, 1250Amps dismantling / opening of the VCB for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling / servicing and its testing and commissioning complete all as specified and directed. Note: - The new spare parts any type will be measured and paid separately.)
Disconnecting 33 KV incoming and outgoing connections of SF6 BREAKER of any description and any make of rating 33 KV,1250Amps complete all as specified and directed by Engineer-in-Charge. dismantling / opening of the SF6 for servicing / overhauling, taking out and removing unserviceable/defective parts including cleaning & servicing, greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the SF6 after overhauling / servicing and its testing and commissioning complete all as specified and directed. Note- The new spare parts any type will be measured and paid separately.)
Taking down the existing relays (two Nos over current and one no earth fault relays) fixed in 33/11KV HT Panels for primary and secondary injection and calibration of all the relays and setting the relay tripping timings in advance to the feeding sub-station to ensure pockets wise installation of various relays in position with complete control and test and trial complete all as specified and directed by Engineer-in-Charge. Note :- (i) The primary injection kit shall be arranged by the contractor. (ii) The DC supply for relay testing shall be arranged by the contractors.
Disconnecting & taking out indoor VCB of any description and any make of rating 11 KV, 400 Amps/630/800/ 1200 Amps dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable /detective parts including cleaning and servicing greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing and commissioning complete all as specified and directed by Engineer-in-Charge.. (Note: - The new spare parts any type will be measured and paid separately.)
Disconnecting & taking out VCB outdoor of any description and any make of rating 11 KV, 400 amps/800 Amps, dismantling/opening of the VCB for servicing/over hauling taking out and removing unserviceable/detective parts including cleaning and servicing greasing, oiling of the movable materials, parts etc and replacement of unserviceable parts with new one, reassembling the VCB after over hauling /servicing and its testing and commissioning complete all as specified and directed. (Note: - The new spare parts any type will be measured and paid separately.)
Testing of leakage of gas of SF6 breaker 33 KV rectifying leakage testing with filling Nitrogen gas making the breaker leak proof filling gas in breaker and testing complete all as specified and directed..
Disconnection and taking out of control cables of any core any size from VCB indoor and out door panels/CTS/PTS/33 KV transformer protection system etc complete all as specified and directed..
Supply and fixing copper pipe of size 32 mm and thickness 3mm bend to shape as requ for 33/11 kv yard complete all as specified and directed..
Supply only following items on completion for 11 KV VCB 400/800 Amps capacity of conforming to the respective cat part given as under complete all as specified and directed. Make:- Crompton Greaves cat part No mentioned against each item or equivalent model as approved by GE. (Note (i) fixing and testing element of following item is deemed to be included under sch 'a' item No - above (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Vacuum interrupter type 190241725/SP VI (3" Dia) Type 34599 M3+ for 11 KV VCB.complete all as specified and directed.
Epoxy bushing for 11 with metal parts complete all as specified and directed.
Isolating contact assembly 400/630 Amp. Cat part No 503. complete all as specified and directed. (Make - CG)
Spout bushing. Cat part No 580 complete all as specified and directed. Make - CG)
Phase barrier with spacer. Cat part No 528 complete all as specified and directed.. (Make - CG)
Motor and gear assembly for 230 volt AC/DC for 11 KV VCB, Cat part No 537 complete all as specified and directed. (Make - CG)
Spring charging handle for hand operating 558SP complete all as specified and directed. Make- CG/ALSTHOM
Support insulator. Cat Part No 591 complete all as specified and directed. Make - CG)
Big gear assembly. Cat part No 543 complete all as specified and directed. (Make - CG)
Small gear assembly. Cat part No 573 complete all as specified and directed.. (Make - CG)
Auxiliary switch (7 No + 7 NC). Cat part No 563 complete all as specified and directed. (Make - CG)
Closing coil assembly 30 volts DC. Cat part No 594 complete all as specified and directed. (Make - CG)
Tripping coil assembly 30 volts DC. Cat part No 599 complete all as specified and directed. (Make - CG)
Trip catches assembly. Cat part No 626 complete all as specified and directed. (Make - CG)
Spout insulator assembly (Back) complete 11 KV 400 AMP complete all as specified and directed.
Plug and socket assembly 560 SP complete all as specified and directed. Make - CG
Trip shaft assembly. Cat part No 574 SP complete all as specified and directed.
Close shaft assembly Cat part No 575 SP complete all as specified and directed.
Big and small gear assembly for out door VCB 11 KV 543 SP1 CG complete all as specified and directed.
Upper and lower insulator assembly for 11 KV 350 MVA out door breaker with flanges assembly..11P002 complete all as specified and directed.
Supply only following items on completion for 33 KV VCB/SF6 breaker 1200 Amps capacity of conforming to the respective cat part given as under complete all as specified and directed. Make:- Crompton Greaves/finolax/ABB/scheneider cat part No mentioned against each item or equivalent model as approved by GE. (Note (i) fixing and testing element of following item is deemed to be included under sch 'a' item No - above (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
Closing coil assembly 30 volts DC for 33 KV VCB/SF6 Breaker.33P019 complete all as specified and directed.
Tripping coil assembly 30 volts DC for 33 KV VCB/SF6 Breaker. 33P018 complete all as specified and directed.
Remote control switch(TNC) for 11/33 kv SF6/VCB panel 618SP complete all as specified and directed.
Motor and gear assembly for 230 volt AC/DC (as per sample) for 33 KV VCB/SF 6. 33P007 complete all as specified and directed. (Make - CG)
Driver rod with slide shaft 33P003 CG complete all as specified and directed.
Trip shaft with spring 33P014 complete all as specified and directed.
Closing shaft with spring 33P015 complete all as specified and directed.
Trip cath with linkage 33P023 complete all as specified and directed.
Big cam with main shaft 33P022 complete all as specified and directed.
Auxiliary switch (7 No + 7 NC). Cat part No 33P024 complete all as specified and directed. (Make - CG)
Vacuum interrupter type VL 35416-13 for 33 KV VCB.complete all as specified and directed.
Ratchet Wheel for 33 KV SF6 BREAKER complete all as specified and directed.
Powel set for 33 KV SF6 BREAKER complete all as specified and directed.
Set of `O' ring for pole for 33 KV SF6 BREAKER complete all as specified and directed.
NATV Roller 15 for 33 KV SF6 BREAKER complete all as specified and directed.
NATV Roller 20 for 33 KV SF6 BREAKER complete all as specified and directed.
Indicator LED lamps of different colour 30 V DC complete all as specified and directed.
Indicator LED lamps of different colour 230 V DC complete all as specified and directed.
Digital multi funcitinal meter for VCB indoor panel Rish master 3440 complete all as specified and directed.. Make : Rishab/Conserve/Alpha
Digital Amp meter for VCB indoor panel 96 sq mm complete all as specified and directed. Make : Rishab/Conserve/Alpha
Digital Volt meter for VCB indoor panel 96 sq mm complete all as specified and directed. Make : Rishab/Conserve/Alpha
Supply and fixing in replacement over current earth fault relay 30V DC for 33/11 KV pannal complete all as specified and directed . Make CG/EASUN/ABB
Supply and laying in replacement 4 core 2.5 sqmm control cable for VCB/CT/PT complete all as specified and directed
Supply and laying in replacement 8 core 2.5 sqmm control cable for VCB/CT/PT complete all as specified and directed.
Supply and fixing in replacement master trip relay 30V DC . MAKE CG/EASUN/ABB complete all as specified and directed
M&L for Cleaning/scraping/decarbonising of VCB indoor panel from inside, bus bar chamber, cable entry box removal of dust carbon particals and painting with super enemaled synthetic paint without efecting wiring busbar and other items complete all as specified and directed.
Supply and fixing PT (Voltage Transformer) for 11 KV indoor VCB, draw out type, 11 KV, 11000/110 V, VA-5 CLASS 1 RATED FRIQUENCY 50 HZ complete all as specified and directed Make - CG/alsthom/laxmi
Supply and fixing CT (Current Transformer) for 11 KV indoor VCB, epoxy dry type, 11 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 100-50/5+5 complete all as specified and directed Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing CT (Current Transformer) for 11 KV indoor VCB, epoxy dry type, 11 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 200-100/5+5 complete all as specified and directed. Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing CT (Current Transformer) for 11 KV Out door, oil immersed type, 11 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 200-100/5+5 complete all as specified and directed Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing PT (Voltage Transformer) for 11 KV out door VCB,oil immersed, 11 KV, 11000/110 V, VA-5 CLASS 1 RATED FRIQUENCY 50 HZ complete all as specified and directed Make - CG/kappa/Alsthom/Laxmi/Pragti
Supply and fixing CT (Current Transformer) for 33 KV Out door, oil immersed type, 33 KV, core 1&2 -10VA CLASS 10P10 STC- 13.1 KA FOR 1 SEC Ratio 200-100/5+5 complete all as specified and directed Make - CG/kappa/Alsthom/Laxmi/Pragti
Reparing servicing overhauling of 33 kv CT/PT replacement of wisher packing set, bushing with brass metal parts, making leak proof and replacement of insulating oil and painting complete all as specified and directed
Reparing servicing overhauling of 11 kv CT/PT replacement of wisher packing set, bushing with brass metal parts, making leak proof and replacement of insulating oil and painting complete all as specified and directed
Reparing/servicing/overhauling to 11 KV air break switch, cleaning greasing and making smooth functioning from ground level complete all as specified and directed.
M/S Kumar Contractors
DURGAI ELECTRICALS
Third Wave Services Pvt Ltd
OM SAI POWER SYSTEMS
M/s SCHOLASTIC ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .