| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹32.8 L+₹1.4 L (4.60%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹32.9 L+₹1.5 L (4.83%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹33.0 L+₹1.6 L (5.09%)Rejected-Finance | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹34.9 L+₹3.5 L (11.0%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
4 Jan 2023, 6:00 pmClosed
MAJ SRINATH PL
GE I Kanpur Cariappa Road Cantt Kanpur 208004
REPAIR TO SEEPAGE, LEAKAGE, ROOF TREATMENT AND OTHER ALLIED WORKS ZONE-I ZONE-II AREA UNDER AGE B R II OF GE(I) KANPUR
2022_MES_566788_1
GE(I)/KAN/T-80 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE(I) KANPUR
₹80,000
Yes
27 Jan 2023
2 Dec 2022
11 Jan 2023
2 Dec 2022
4 Jan 2023
23 Dec 2022
Amount
Dismantling of terracing tiles/brick tiles single layer on roof,laid bedded and pointed in any mortar complete all as specified and directed.
Demolition by using hand held electric drills, cutting machine, chisels etc (direct use of hammers on RCC roof for demolition is strcitly prohibited) of roof treatment including padding concrete of any description including mud in roof any thickness with and including roughening old concrete surfaces by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and as directed.
M&L for cement concrete type B0 (1:2:4 ) using 12.5 mm graded stone aggregate as in padding and coping including hunching, benching etc complete all as specified and directed.
M&L for 10 mm thick in CM(1:3) rendering on fair faces concrete surfaces/roof top mixed with liquid water proofing compound finished even & smooth without using extra cement complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.
Supply only liquid water proofing compound complete all as specified and directed.
M & L roof kerb of cement concrete 1:2:4 type B0 using 12.5 graded stone aggregate mixed with and including SBR ploymer as per manufacturer's instructions all around periphery of the wall complete all specified and directed.
M & L preparation of newly plastered sufaces of roof including cleaning the surfaces by using wire brush / pressure hose and applying high performance polyurethene liquid membrane roof coating cold applied in two coats @ 1.5Kg /Sqm/ 2 coats spray/ brush applied, with an elongation of 300% to 700% and tensile strength of not less than 3 N/Sqmm as per ASTM D412 and ASTM D2370, crack bridging abiltity of 3.5mm as per ASTM C1305, shore a hardness of not less than 60 as per ASTM D2240. The item includes epoxy primer applied @ 0.15Kg/Sqm and a geotextile of 40 GSM to be applied over first coat while first coat is still wet,complete as per manufacturer's instructions complete all as specified and directed. Note: The contractor shall submit a gurantee of 10 years from the date of completion of work for roof treatment alongwith manufacturer's gurantee. The amount of Rs. 40 ( Forty ) per Sqm and min of Rs. 4000/- for roof treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against guarantee money. 2. The roof treatment shall be carried out by authorised applicator of manufacturer. The name of applicator shall be got approved from GE before commencement of work.
M&L for Preparation of newly plastered roof surface by cleaning surface free from dust and other foreign materials etc. and laying Mineral finish APP polymer modified membrane pre fabricated 3mm thick with non woven polyester matt central core of 160 gms/Sqm weighing not less than 3.00 kg per sqm, laid over primer conforming to IS 3384 @ 0.4 lit/sqm by using LPG/Butane torch and applying uniform pressure with a roller with overlap of 100mm in longitudinal direction and 150mm in transverse direction laid as per manufacturers instructions and ends sealed with cement mortar 1:3 mixed with and inclduing SBR latex @200 ml/bag of cement curved well complete all as specified and directed.
Note: The contractor shall submit a gurantee of 10 years from the date of completion of work for waterproofing treatment alongwith manufacturer's gurantee. The amount of Rs. 25 ( Twenty Five ) per Sqm and min of Rs. 2500/- for waterproofing treatment shall be withheld from contractor's final bill till the expiry of gurantee period. The contractor at his own option may furnish fix deposit receipt pledged in favour of GE(I) Kanpur against guarantee money.
M&L for brick tiles 40mm thick with minimum flexural strength 1.5 N/Sqmm set, joints grouted flush in CM 1:3 mixed with chemical (plasticizer) by weight of cement over 15 mm thick screed bed in CM 1:4, complete all as specified and as directed.
Raking out joints/pointing to brick work , brick tiles, laid flat, in floors, surface channels, roofs, etc and complete all as specified and directed.
M&L flush pointing to 30 cm by 15 cm brick tiles laid flat in paving & roofs in cm 1:3 including chemical plasticizer by weight of cement complete all as specified and directed.
Taking down cement plaster on brick or stone walls exposing the surface till brick level, as specified and directed.
M & L for Complete removal of existing paint, Putty and primer coating and exposing the surface till plaster level, complete all as specified and directed.
M&L for 15 mm thick in CM(1:4) rendering on fair faces brick wall concrete surfaces and parapet wall mixed with liquid water proofing compound finished even & smooth without using extra cement complete all as specified and directed. Note : Liquid WPC shall be measured and paid separately.
M & L for Acid/Alkali wash and drying of any existing efflorescence and leaving the wall to dry for min. 3 days and watch for any extra efflorescence. The surface to be washed with clean water and left to dry for 3 to 4 hours before application of further treatment complete all as specified and directed.
Supplying and Applying , one component penetrative-cum-film forming interior waterproofing solution, with negative hydrostatic resistance upto 4 bar, with forced coverage of 350 ml per Sqm single coat using brush or roller, complete all as specified and directed.
Supplying and Applying, two components acrylic polymer modified cementitious coating on new masonry surfaces devoid of plaster, with Hydrostatic resistance upto 5 bars with forced coverage of 1.75 Kg per Sqm in two coats using roller or brush with a gap of 4 to 6 hrs between the coats. The coats to be applied shall be perpendicular to each other complete all as specified and directed. Note : The Coverage is to be strictly maintained for film formation.
M&L for preparation of new surfaces of wall and Applying Two coats of cement base paint over a coat of primer on wall complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coat oil bound distemper of any colour on over a coat of primer over applying a coat of wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc complete all as specified and directed.
M & L preparation of new surfaces of wall and applying three coats of white wash complete all as specified and directed.
Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets as specified and directed.
Supply & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling system with DUNE(MICRO LOCK) EDGE TILES WITH ARMSTRONG XL 15mm EXPOSED STEEL ANGLE. The tiles should have humidity Resistance (RH) of 99%, NRC upto 0.5, Light reflectance >85%, Thermal conductivity k=0.052 - 0.057 w/m K, Colour White, Fire performance Class 0/Class1 (BS 476 part 6&7) in module size of 600X600X16 mm with Bio Block coating on the face of tiles, suitable for green building application, with recycled content of 38-41%. The steel angle should be of 'Armstrong' make with 15mm wide T-section flanges colour white having rotary stitching on all T-sections i.e the Main Runner, 1200mm & 600mm Cross section tees with a web height of 32, 27 & 27mm and a load carrying capacity of 7.5Kgs/sqm. The T-sections have a Galvanizing of 90gms per Sqm & passed through 500hrs of salt test, perimeter trim to be Armstrong wall angles of Size 30X19X19 mm , secured to walls at 450mm maximum centre to centre complete all as specified and directed according to manufacturers instruction.
Taking down wall panelling,wooden flooring and similar work as specified and directed.
S & F 5mm thick plain/printed coloured PVC sheet in strips & channel feathered at the edges for fixing on solid PVC wall lining, Insulated PVC wall Lining, and solid PVC partitions inclusive of Solvent cement at site complete as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
M & L for MS Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (Fe-290 Gde E-165) complete all as specified and directed.
S & F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S & F for Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
Taking up or down steel tubing and connections of 15 mm bore complete all as specified and directed.
Taking up or down steel tubing and connections of 20 mm bore complete all as specified and directed.
Taking up or down 25 mm dia steel tubing and connection including cleaning for refixing or removal complete and all as specified and directed.
M&L for cutting chases for concealed water tubing and making good in CM (1:3), cutting not exc 10 cm girth in brick wall complete all as specified and directed.
S & F GI steel tubing 15 mm bore medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete as specified and directed.
S & F GI steel tubing 20 mm bore medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors as specified and directed.
Fixing only old steel tubing 15 mm dia of bore and connections in new or old position (Walls, ceiling, floors, etc.) and complete all as specified and directed.
Fixing only old steel tubing 20 mm dia of bore and connections in new or old position (Walls, ceiling, floors, etc.) and complete all as specified and directed.
Fixing only old steel tubing 25 mm dia of bore and connections in new or old position (Walls, ceiling, floors, etc.) and complete all as specified and directed.
S&F in repair 20mm dia Gun metal globe or gate valve with iron wheel head, screwd both ends for iron pipe complete as specified and directed.
Dismantling PVC water tanks and remove to store capacity exc 250 Ltrs and n exc 500 Ltrs complete all as specified and directed.
S & F HDPE triple layer rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) 500 litres capacity hoisted and fixed in position all as specified in SSR Pt-I including for hoisting into position either inside or outside of building, connecting up pipes, securing access cover etc including GI nipple of suitable size complete all as specified and directed.
S & F in repair 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod with high density plastic ball screwed for iron pipe and fixed complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required ) for repairs, cleaning etc. and hoisting if required & reconnecting and refixing in old or new position complete all as specified and directed.
S & F in repair water tank cover capacity exc 250 ltrs and n exc 1000 ltrs complete all as specified and directed.
Demolition of brick work built in cement mortar complete all as specified and as directed .
M &L for Brickwork with subclass `B' Old Size bricks, straight or curved on plan exc 6m mean radius, built in Cement mortar 1:6 complete all as specified and directed.
M&L for Brick work with fly ash brick straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 with complete all as specified and directed.
M&L Brick work (except bricks) old size sub class ' B' brick straight or curved on plan exceeding 6 mtr mean radius built in cement mortar (1:6) complete all as specified and as directed.
Taking down 75/ 110 mm dia rain water pipes, any pattern with all fittings complete all as specified and directed.
S&F (SWR) PVC Pipe 110 mm pipes double socketed in any length with rubber ring joints fixed to wall/ceiling and complete all as specified and directed.
S&F PVC (SWR) bends 110 mm bore and complete all as specified and directed.
Removing of demolished meterial to a distance of 200m or under, beyond the lead included in the rates, including loading, unloading complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) complete all as specified and directed.
M&L for 7 to 8 mm thick non skid ceramic coloured tiles (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc; laid jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles over & including 15mm thick screed bed in CM(1:6) complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450x300 mm & 6 to 7 mm thick on vertical surface of walls such as in dado, skirting etc; including and jointing in neat cement slurry and pointed in white cement mixed with pigment to match with shade of tiles, including 10mm thick rendering in CM(1:4) complete all as specified and directed.
Demolition of Concrete (unreinforced) of any description and in any position and complete all as specified and directed.
M&L for PCC 1:4:8 Type D2 (40mm graded aggregate) as in foundation and complete all as specified and directed.
M & L for PCC 1:2:4 type B2 using 40 mm graded stone agg as in flooring/path, etc complete all as specified and directed.
Agarwal Builders
M/S MAA TARA TREATMENT PROJECT
m/s sahu enterprises
M/S SDS Construction Co.
SHASHI CONTRACTORS
JOG CONSTRUCTION
M/s DKS Engineering Works
Khalil Ahmed and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .