| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹19.3 L+₹1.8 L (10.4%)Rejected-Finance RAM JANAKI THAKURBARI J T ROAD DIMAPUR 797112 NAGALAND | DIMAPUR | NAGALAND | 797112 | L2 | Rejected-Finance Quoted rate higher than L1 bidder |
Tender Value
₹22.3 L
EMD Value
₹44,700
Closing Date
14 Nov 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 137 Wks Engrs PIN 914137 co 99 APO
SPECIAL REPAIR TO BLDG NO BT 14 (OR LIVING) OF 220 TRANSIT CAMP AT RANGAPAHAR MILITARY STATION
2020_MES_386883_1
8502/E8
Open Tender
Civil Works
Item Rate
180 days
Rangapahar
Class E
Category a i
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹44,700
31 Dec 2020
16 Oct 2020
16 Nov 2020
16 Oct 2020
14 Nov 2020
30 Oct 2020
60 days
Amount
Dismantling of AC (corrugated, semi corrugated etc) roof sheets including ridge and valley etc as in roof covering and removing unserviceable materials from site of work complete all as specified and as directed.
Dismantling Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of reed, lathing, single or double including battens and plaster or chicken wire lathing and removing unserviceable materials from site of work complete all as directed.
Dismantling timber scantling 40 Sqcm and over in section, in any position in unframed work and removing materials from site of work complete all as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc.15cm thick (below or above ground level) and removal of rubbish from the site complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quions, arches, pillers etc complete all as specified and as directed.
Taking down shutters of any description n.exc. 1.00 Sqm each complete all as specified and as directed.
Taking down wooden chowkats or frames with shutters exc. 1.50 Sqm but n.exc. 4 Sqm each (without taking of shutters from the frames) complete all as specified and as directed.
Dismantling timber boarding of any description and fixed in any position secured with nails complete all as specified and as directed.
Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based corrugated / semi corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed.
Supply and fixing 0.50mm thick pre-painted galvalume aluminium Zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as per manufacturer instruction complete all as specified and as directed.
Material and labout for PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in foundation filling, mass concrete complete all as specified and as directed.
Supply and fixing Rolled mild steel joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe 410-W (Gde-E- 250) quality- A etc complete all as specified and as directed .
Material and labour for rolled mild steel for roof trusses ( framed), trussed, purlins, crane grantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe 410-W (Gde-E-250) quality-A complete all as specified and directed.
Supply and fixing rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe-410-W (Gde E-250) quality- A complete all as specified and as directed.
Material and labour for mild steel works as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
Supply and fixing 4 mm thick size 595 x 595 mm HPSC (High pressure Steam Cured) pre-primefered self embossed texture designer board E-board classic to be fixed with and including anodized aluminium grid / section of size 600 mm x 600 mm with main runner 38 x 24 x 0.90mm thick, cross tee 28.6 x 24 x 0.9 mm and wall angle 19 x 19 x 0.9 mm duly suspended with 2 mm dia GI wire hanger 1200 mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour / shade / matrix of tiles and shall be laid over and including 15mm thick screed bed / bedding layer in CM (1:6) finished the surface of screed bed even and fair to receive tile complete all as specified and as directed.
Material and labour for non skid ceramic coloured tiles 7 to 8mm thick (Square/ rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm on vertical surfaces as in dado / skirting etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour / shade / matrix of tiles shall be laid over and including 10mm thick cement plaster / backing coat in CM (1:4) finished the surface even and fair to receive tile complete all as specified and as directed.
Materials and labour for 15 mm thick rendering on one side of lathing in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Materials and labour for rendering 15mm thick plaster in cement mortar (1:6) on the other side of lathing finished even and smooth without using extra cement complete all as specified and as directed.
Supply and fixing GI wire netting 0.71mm dia and 12mm mesh lathing to wood or metal studding, joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified and as directed.
Material and labour for well seasoned 2nd class hard wood timber in scantlings, clean sawn, timber framed and fixed complete all as specified and as directed.
Materials and labour for half brick thick brick work with sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) complete all as specified and as directed.
Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed.
Materials and labour for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar (1:4) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Materials and labour for 15 mm thick rendering on other than fair faces of brick work or concrete surface in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 25 mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in leveling course finished the surface fair and even complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection, paving, footpath etc and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in surface channel and like etc complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc. complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm from item No. 32 above. (For adjustment only)
Supply and fixing well-seasoned 2nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Supply and fixing for 35mm thick factory made flush door shutters solid core construction with block board core and ply wood face panels commercial type on both faces complete all as specified and as directed.
Material and labour well seasoned 2nd class hard wood plain fillets, square, rectangular in section, clean sawn secured with nails or brads, sectional area exc. 13 but not exc. 25 Sqcm complete all as specified and as directed.
Material and labour for 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified.
Material and labour for 30mm thick 2nd class hard wood factory made Glazed and skelton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated without sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified.
Supply and fixing in repair Harrison rail mild steel chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
Supply and fixing for 300mm long mild steel ordinary rat tail rod pattern springs for doors including roller and roller plate complete all as specified and as directed.
Supply & fixing floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 150mm complete all as specified and as directed.
Supply and fixing 3 mm thick sheet glass, ordinary quality and glazing with oil putty, glazing pin etc or wooden beads in square n.exe 0.50 Sqm in each pane complete all as specified and directed.
Supply and fixing as mild steel galvanized iron wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 and fixed with tinned tacks or staples complete all as specified and as directed.
Supply and fixing 100mm size butt hinges, medium weight, cold rolled mild steel, complete all as specified and as directed.
Supply and fixing 75 mm size stainless steel butt hinge complete all as specified and directed.
Supply and fixing 150 mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed.
Supply and fixing 125 mm long extruded aluminium alloy handles, cast type, anodised complete all as specified and as directed.
Supply and fixing aluminium anodized, barrel tower bolts, 200mm long of extruded section complete all as specified and as directed.
Supply and fixing aluminium anodized, barrel tower bolts, 150mm long of extruded section complete all as specified and as directed.
Supply and fixing 300mm long aluminium alloy, anodized, sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts,of extruded sections or cast aluminium alloy complete all as specified and as directed.
Supply and fixing second class hardwood weather boarding, clean sawn, plain, 20mm thick or feather edged 15 mm to 20mm thick and fixed with 30mm laps complete all as specified and directed.
Material and labour for preparation of new wooden surfaces of any description n.exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of old painted wooden surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed.
Material and labour for preparation of new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Material and labour for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and as directed.
Material and labour for preparation of newly plastered or previously untreated wall surface by washing, rubbing down and stopping and applying two coats of distemper oil emulsion over a coat of chalk whitening primer complete all as specified and as directed.
Material and labour for preparation of newly plastered or previously untreated wall surface including cornices etc and applying two coats of cement base paint over a coat of primer complete all as specified and as directed.
Material and labour for preparation of old decorated wall surface including cornices etc and applying one coats of cement base paint complete all as specified and as directed.
Material and labour for 75 mm thick PCC 1:3:6 type C2 (using 40 mm graded stone aggregate) as in sub base of floor finish the surface fair and even to receive subsequent layer complete all as specified and directed.
Material and labour for anti fungal chequered cement concrete tiles of size 200 x 200 x 25mm thick as in floor, set and jointed in neat cement slurry and pointed with cement laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed.
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete, (including unscrewing from boards/out-let boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc.), removing materials off the site of work and making good disturbed surfaces of walls, floors, etc.all as directed.
Material and labour for point wiring (surface type) for one light/fan/call bell point with 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC (FR-LSH) insulated unsheathed copper cable multistrand conductor 1100 volts grade for earth continuity wire connected to common earth dolly drawn through and including PVC casing caping of adequate size with all accessories and PVC rectangular boxes for mounting switch socket and fan regulator etc complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
.-Ditto- all as per item No 62.00 here-in-before but for one additional light / fan point with 1.5 Sqmm cable and -ditto-.
.-Ditto- all as per item No 62.00 here-in-before but for 3 pin 6 amps switch socket outlet on the independant board with 1.5 Sqmm cable and -ditto-.
.-Ditto- all as per item No 62.00 here-in-before but for 3 pin 6 amps switch socket outlet on the same board with 1.5 Sqmm cable and -ditto-.
.-Ditto- all as per item No 62.00 here-in-before but for one 3 pin 16 Amps switch socket combination on independent board with 2.5 sqmm PVC (FR-LSH) insulated un-sheathed copper conductor cable multistranded conductor 1100 volts grade and 2.5 Sqmm PVC (FR-LSH) copper conductor cable as earth continuity conductor and -ditto-.
Supply and fixing Piano switch flush button single pole one way 6 Amps complete all as specified and as directed.
Supply and fixing socket outlet 5 pin, 6 Amps, 230 volt flush type complete all as specified and as directed.
Supply and fixing switch socket combination 2 in 1, 6A/16A, flush type universal complete all as specified and as directed.
Supply and fixing fan regulator 100/120 watt step type AC 220 Volt complete all as specified and as directed.
Supply and fix ceiling rose surface Polycarbonate/ PVC three terminal complete all as specified and as directed.
Supply and fixing sub-main wiring with PVC insulated & unsheathed two run of 4.00 Sqmm single core multi stranded copper conductor cable (FRLSH), 1100 Volt grade alongwith one run of 4.00 Sqmm PVC insulated & unsheathed copper conductor cable (FRLSH), 1100 Volt grade, connected to common earth dolly as earth continuity conductor, drawn through PVC Casing Caping of adequate size with all accessories including taking down existing unserviciable sub main wiring complete all as specified and as directed. Note : Three runs of 4.00 Sqmm cable and one run of Casing Caping shall be measured as one unit for payment purpose.
upply and fixing for lamp holder , PVC / Polycarbonate type with PVC round / square block with and including 9 watt LED lamp suitable for lamp holder fittings including taking down old unserviceable one complete all as specified and as directed.
Supply and fixing in replacement 20 watt LED, 4 feet long, wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation and electronic driver etc with all accessories, internally prewired and fixing the same on and including two Nos. PVC blocks and connecting up with flexible copper cable of size 0.75 Sqmm 3 core from ceiling rose to the light fittings includiong taking down old unserviceable light fitting complete all as specified and directed. (Make: Cat No. LHFXCEP1TNNW020 for batten and LHLDDCXCML8Q020 (LED Tube) of Havells or equivalent model of Bajaj / Philips)
Taking down existing unserviceable building security light fittings of any description with accessories and supply and fixing LED 1x20 W security light fittings drawn through and including GI brackets of of 25 mm dia light grade 1.40 metre long bend to shape with MS clamps made out of flat iron of size 40 X 4 mm , 02 Nos, including nuts, bolts, washers etc as required and connecting up with flexible copper cable of size 0.75 Sqmm, 3 core from ceiling rose to the light fittings complete all as specified and directed. (Cat No. SL20WLLED757SASYTOPCMP of Havells (ENDURAPEARL) or equivalent model of Bajaj / Philips)
Supply and fixing MCB DB SPN 8 ways double door, 230 Volts, including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall including taking down old unserviceable DB alongwith MCBs complete all as specified and as directed.
Supply and fixing MCB 6-32 Amps, SPN, 230 Volt "C" series, breaking capacity 10 KA complete all as specified and as directed.
Supply and fixing MCB 6 - 32 Amps, SP, 230 Volt "C" series, breaking capacity 10 KA complete all as specified and as directed.
Supply and fixing as MCB DB TPN 8 ways double door, powder coated including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall including taking down old unserviceable DB alongwith MCBs complete all as specified and as directed.
Supply and fixing MCB 100 Amps, TPN, 415 Volt "C" series, breaking capacity 10 KA complete all as specified and as directed.
Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 16 Sqmm 2 core laid in trenches or fixed to wall / pole / ceiling as per IS 7098 (Part I) including connection cable glands, aluminium lugs etc including taking down unservicable cable complete all as specified and as directed. Note : Earth work, brick protection and sand cushioning and GI Pipe will be measured and paid separately under respective item.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying cable etc. or for foundation of pole etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in, of soil including spreading leveling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed .
Removing exvated material to a distance n.exc 50M and deposited/ spreaded where directed at a level n. exc 1.5 M above the starting point complete all as specified and as directed .
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down complete all as specified and as directed. (Note: Punned thickness shall be measured for payment purpose)
Materials and labour for brick protection cover to underground cables with sub class ‘B’ over burnt brick of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting each other with gaps not exceeding 10mm complete all as specified and as directed.
Supply and laying GI tubing 40mm bore light grade with fittings laid in trenches or for road crossing for protection of LT underground cables including taking up/down unserviceable pipe complete all as specified and as directed.
Taking down ceiling fan carefully of any sweep from its original position, dismantling the complete fan, cleaning all dust particle, applying grease for bearing, applying spray painting of synthetic enamel paint of supirior quality including filling up cavities with filler, reassembling the fan and blades and hanging the fan in same position and testing on completion complete all as specified and directed.
Material and labour for rubber bush with clamp set comprising GI nuts, bolts, washers and split pin complete all as specified and directed.
Supply and fixing as in replacement of capacitor 2.5Mfd including making necessary electrical connection complete all as specified and as directed.
Supply and fixing as in replacement ball bearing/bush suitable for ceiling fan as per existing sample complete all as specified and as directed.
Material and labour for rewinding existing ceiling fan with suitable gauge of copper wire complete all as specified and directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised wire of 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe of 15mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed. (Note: Earthwire upto 7.50 m from earthplate shall be measured and paid in the quoted rate)
SHRI BANARSI PRASAD
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .