Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.5 LAccepted-AOC HOUSE NO 66 GALI NO 3 ARJUN NAGAR PATHANKOT 145001 PB | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Found lowest | |
| 2 | L2₹23.7 L+₹14,041 (0.60%)Rejected-Finance DALHOUSIE ROAD BYE PASS CHOWK PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not found lowest | |
| 3 | L3₹24.2 L+₹65,697.50 (2.79%)Rejected-Finance | L3 | Rejected-Finance Not found lowest | |
| 4 | L4₹25.2 L+₹1.6 L (6.90%)Rejected-Finance | L4 | Rejected-Finance Not found lowest | |
| 5 | L5₹29.7 L+₹6.2 L (26.2%)Rejected-Finance | L5 | Rejected-Finance Not found lowest |
Tender Value
₹28.1 L
EMD Value
₹56,220
Closing Date
12 Sept 2024, 6:00 pmClosed
Maj Nitin Bisht
GE Basoli PO Lakhanpur Distt Kathua (JK) 184152
GE/BAS-31/2024-25 Special repair to roof in Bldg No T-31(Sqm Store), T-42 (HRDC) and special repair to sewage system from single JCO Accn to Jco mess at Basoli station under GE Basoli
2024_MES_666646_1
GE/BAS-31/2024-25
Open Tender
Civil Works
Item Rate
120 days
Basoli Station under GE Basoli
As per tender docs
8 documents required · 8 mandatory
₹500
GE Basoli
₹56,220
Yes
4 Nov 2024
19 Jul 2024
14 Sept 2024
19 Jul 2024
12 Sept 2024
3 Aug 2024
Amount
Excavation in trenches n exc 1.5 m wide and nexc 1.5 m in depth for foundation and laying of UG cable/GI pipe and like getting out in any type of soil complete all as specified and directed.
M&L returning, filling and including spreading, levelling , watering and well ramming in layers not exceeding 25 cm complete all as specified and directed.
Removing excavated material nexc 50m and depositing where directed at a level nexc 1.5mtr above the starting point , complete all as specified and directed.
Surface excavation not exc 30cm deep and averaging 15cm deep and gettingout in any type of soil complete all as specified and directed.
Taking down chowkats or frames with shutter (without taking off shutter from the frames) n. exc 1.50 Sqm each complete all as specified and directed .
Taking down chowkats or frames with shutter (without taking off shutter from the frames) exc. 1.50 Sqm n.exc 4 Sqm each complete all as specified and directed.
Dismantling/Taking down of wrought iron or mild steel work of any description, any thickness. complete all as specified and directed .
S&F Structural steel work as in frames for roof trusses (Framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410 Gde E-250 quality B including welding complete all as specified and directed.
S&F Mild steel screw bolt 5 to 10mm dia,5cm long machine made, with hexagonal head at one and screwed the other or screwed bolts each screwed and to be fixed with washer and one hexagonal or square nut complete all as specified and directed.
M&L for pressed steel frames for doors with one or more rebates including necessary supply and fixing lugs, hinges, lock strike plate etc. complete of frame size 125 x 60 mm complete all as specified and directed .
M&L for providing cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and directed .
S&F 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed .
S&F For Glazed and skelton shutters 35mm thick of 2nd class HW open rebated and prepared to receive glass or wire gauze etc. shutters divided in square with sash bars, size of members of shutters as specified in SSR Part-1, secton 8, clause 8.20(a) complete all as specified and directed.
S&F Galvanised MS wire cloth 0.46mm nominal dia of wire and average width of aperture 1.18mm, complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane complete all as specified and directed.
S&F aluminium anodised barrel tower bolts 200 mm long of extruded section fixed with stainless steel screws ,ISI marked, complete all as specified and directed .
S&F aluminum anodised handle ,125 mm size.cast type complete all as specified and directed.
S&F 300 mm long aluminium anodised, sliding door bolt with hasp, staple (bolt type dia not less than 16 mm) including fittings and fixtures , ISI marked, complete all as specified and directed .
M&L for preparation of treated/un-treated wooden surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including Dismantling asbestos cement (corrugated, semi corrugated etc sheets in roof covering complete all as specified and directed .
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified including Dismantling asbestos cement (corrugated, semi corrugated etc sheets in roof covering complete all as specified and directed .
M&L Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25mm thick MS Sheet tube factory made with double side shutters wire guaged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150mm long for each leaf and 10mm square bar grills at spacing shown on drg welded to GI frame work, including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed .
M&L for preparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed .
M&L for preparation of old wooden surfaces of any description over 10cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed .
Dismantling timber scantlings unframed work, 40 sq. cm and over in section, in any position complete all as specified and directed .
Material and labour for plain cement concrete type B-1 1:2:4 (20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses,lacing courses, parapets and railings upto 60 cm in height,copings, kneelers, apex stones, bed plates, kerbs ,water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed ..
S&F in repair 110 mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints , fixed to wall complete all as specified and directed ..
S&F in repair 75 mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints , fixed to wall complete all as specified and directed ..
S&F in repair 110 mm bore PVC (SWR) Pipes single socketed in any length with rubber ring joints , laid in trenches/floor complete all as specified and directed ..
S&F PVC (SWR) Bends in any radius 110 mm bore in repair complete all as specified and directed ..
S&F PVC (SWR) Bends 110 mm bore with access door in repair complete all as specified and directed ..
S&F PVC (SWR) Bends 75 mm bore with access door in repair complete all as specified and directed ..
S&F in repairs for 125/110mm bore PVC (SWR) gully trap plain including jointing with solvent cement complete all as specified and directed
S&F in repairs Stainless steel grating 100mm dia fixed with white cement complete all as specified and directed
S&F PVC (SWR) junction single (single T) equal or unequal provided 110 mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T) equal or unequal provided 75 mm bore complete all as specified and directed.
PVC reducers 110 x 75 mm complete all as specified and directed.
S&F PVC (SWR) Vent cowl 75 mm bore in repair..complete all as specified and directed.
Demolition of reinforced cement concrete of any description. complete all as specified and directed .
M&L for 100 mm thick PCC type C-2, 1:3:6 (40mm graded stone aggregate) as in sub base complete all as specified and directed .
M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed .
M&L for 10mm thick rendering/screeding on fair faces of brick / concrete surfaces in cement mortar 1:4 and finished even and fair for receiving tiles complete all as specified and directed .
M&L for Vitrified tiles in dark shade 10mm thick (Square/reactangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed .
M&L for Vitrified tiles in dark shade 10mm thick (Square/reactangular) area of each tiles exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/dado etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed .
M&L for Premium Quality Durastone / Endura heavy duty vitrified tiles of size 300 mm x 300 mm x 10mm to 12mm thick as in floors and skirting set and jointed in neat cement slurry and pointed in white cement to match the surface complete over screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed .
Dismantling of floors, hearth or wall tiling including cement mortar bedding and removing rubbish off the premises complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in dado and skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed ..
Taking down cement plaster on brick or concrete surface of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6, on fair faces of brick work or concrete surfaces , finished even and smooth without using extra cement, preparation of new plastered surfaces of walls and applying 1mm thick wall care putty and two coat oil emulsion distemper on walls complete all as specified and directed .
M&L for preperation of old decorative surface of wall and applying applying 1mm thick wall care putty and one coat of oil bound distemper complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4, on fair faces of brick or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed .
M&L for Preparation of new plastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less then 50 gm/litre and UV resistence as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed .
M&L for Preparation of old plastered surface and applying two coats of 100% Premium acrylic emulsion paint having VOC less then 50 gm/litre and UV resistence as per IS 15489:2004, Alkali & Fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces. complete all as specified and directed.
S&F in position suspended false ceiling system using E-grid suspended ceiling grid system. The size of grid shall be 600x600mm with aluminium frame work main runner 38x24mm cross tee 25x24mm and wall angle 24mmx24mm using 9mm thick ceiling panel laminated wth PVC film on front face and foil back available in due drop texture as per IS- 2095 Part-I 1996 fixed in the grid of E grid suspended ceiling Grid system duly suspended by 4mm dia GI bar hangers from the purlins of the roof with butter fly clips.including dismantling of existing AC board any thickness complete all as specified and directed
M&L for concrete bed to drain pipes laid in trenches incl packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) for 150mm bore of pipe complete all as specified and directed
M&L for Reinforced concrete pipes150mm, class NP3, laid and jointed complete with collars bed complete incl testing all as specified (Concrete to be measured and paid for separately) complete all as specified and directed
M&L for concrete bed to drain pipes laid in trenches incl packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) for 200mm bore of pipe complete all as specified and directed
M&L for Reinforced concrete pipes200mm, class NP3, laid and jointed complete with collars bed complete incl testing all as specified (Concrete to be measured and paid for separately) complete all as specified and directed
M&L for concrete bed to drain pipes laid in trenches incl packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregates) for 100/110mm bore of pipe complete all as specified and directed
M&L Cement concrete M-7.5 (Nominal mix),type D-2, 1:4:8, (using 40 mm graded crushed stone aggregates) in foundation filling and mass concrete,post holes etc complete all as specified and directed
Demolition of brickwork built in cement mortar including all quions, arches, pillar complete all as specified and directed
M & L Brick work curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:6 and external pointed flush in same mortar as the work proceeds. complete all as specified and directed
All as per item No 66 above but except brick complete all as specified and directed
M & L Brick work curved on plan exc 6m mean radius with old size bricks built in cement mortar 1:4 and external pointed flush in same mortar as the work proceeds. complete all as specified and directed
M & L for Half thick Brick wall work curved on plan in any radius with old size bricks built in cement mortar 1:4 and external pointed flush in same mortar as the work proceeds. complete all as specified and directed
M&L for Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or conrete surfaces finishing the surface even and smooth without using extra cement mixed with water proofing compound @ 3% of cement weight complete all as specified and directed
M&L for Reinforced cement concrete M-20 (Nominal mx) using 20mm graded crushed stone aggregates as in slabs/shelves, supported on walls, beam and columns in floors, and in shelves and the like complete all as specified and directed
Use & waste of steel form work as in slabs/shelves, supported on walls, beam and columns , and in shelves and the like complete all as specified and directed
M&L Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed
M & L Precast cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover including necessary form work as required complete all as specified and directed
M & L Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified and directed
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 0f 60mm thickness with grey cement and pigment, M-35 grade including 50mm thick layer of sand cushioning complete all as specified and directed .
M&L PCC, type C-2, 1:3:6, ( using 40mm graded crushed stone aggregate) as in surface channel and drain including demolition of un-reinforced cement concrete in ground floor and paving complete all as specified and directed
Cleaning of blocked sewage drain pipe line of 100mm dia and removing all sludge and foreign material manually or mechanically as required etc complete from the pipe line and making it serviceable free flow of sewage complete all as specified and directed .
Demolition of cement concrete unreinforced in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for Construction of septic tank with cover slab RCC M-25 (Design mix) for "50" users brick work in CM 1:4 (with top of slab at ground level) incl necessary excavation and earth work in any type of soil and disposal of surplus soil as directed including RCC manohole covers with angle iron welded frame complete vent shaft cowl all as shown on drg and specified.Ref Drg no CEPZ/TD/013/13 Sht 1/5 to 5/5
M&L for construction of soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM 1:4, RCC cover slab in M-25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size,complete of size 3.0 m dia x 4.5 m deep, complete all as specified and as directed. Ref Drg no CEPZ/TD/013/13 Sht 1/5 to 5/5
Dismantling of PVC(SWR)/CI/Concrete pipe, drain pipe any type, including concrete bed, internal dia of pipe 100/110mm, and takingout from trenches complete all as specified and directed
Dismantling of PVC(SWR)/CI/Concrete pipe, drain pipe any type, including concrete bed, internal dia of pipe 150mm, and takingout from trenches complete all as specified and directed
Dismantling of PVC(SWR)/CI/Concrete pipe, drain pipe any type, including concrete bed, internal dia of pipe 200mm, and takingout from trenches complete all as specified and directed
Supply only integral Water Proofing Compound. complete all as specified and directed
M&L for complete removal of existing surfaces of walls and applying 3mm thick wall care putty and two coat oil emulsion distemper on walls complete all as specified and directed .
Taking down copper/aluminum point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as per specified and directed.
Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in and incl rigid PVC conduit concealed medium grade with pressed mild steel terminal boxes(sheet not less than 1.6 mm thick) duly painted with a coat of red oxide primer with suitable thickness plastic laminated sheet cover 3mm thick of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge.Note: a) Rate for cutting chases for conduits and sinking for boxes and making good to wall, floors deemed to be included in each point etc (b) On RCC roof ceiling PVC conduit shall be provided on surfaces for any necessary point with proper fixing clips and no extra cost shall be paid for the job etc complete all as per specified and directed.
All as per item No 86 but for one 3 pin 5 Amp socket outlet on independent board complete all as per specified and directed.
All as per item No 86 but for one 3 pin 5 Amp socket outlet on same board complete all as per specified and directed.
Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in and including rigid PVC concealed conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes(sheet not less than 1.6mm thick) of adequate size with suitable thickness plastic laminated sheet cover 3mm thick for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, complete all as per specified and directed.
Point wiring with 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable in existing rigid PVC conduit concealed medium grade with pressed mild steel terminal boxes(sheet not less than 1.6 mm thick) duly painted with a coat of red oxide primer with suitable thickness plastic laminated sheet cover 3mm thick of adequate size for one light or one fan controlled by one switch incl 1.5 Sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed by Engr-in-charge.
All as per item No 90 but for one 3 pin 5 Amp socket outlet on independent board complete all as per specified and directed.
All as per item No 90 but for one 3 pin 5 Amp socket outlet on same board complete all as per specified and directed.
Point wiring with 2.5 sqmm FRLS, PVC insulated and unsheathed multi stranded flexible copper conductor cable drawn in existing conduit medium grade of suitable size with sunk cast iron/pressed steel terminal boxes(sheet not less than 1.6mm thick) of adequate size with suitable thickness plastic laminated sheet cover 3mm thick for one 3 pin socket outlet 15 Amp on independent board including continuous 2.5 sqmm FRLS,PVC insulated and unsheathed copper conductor cable (multistranded) as earth wire to common earth dolly, complete all as per specified and directed.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in sheet metal box alongwith outer cover plate for mounting modular switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm complete all as per specified and directed..
All as per item No 94 above but for one 3 pin 5 amps socket outlet on the same board with other switchs complete all as per specified and directed..
All as per item No 94 above but for one 3 pin 5 amps socket outlet on independent board with other switchs complete all as per specified and directed..
All as per item No 94 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size complete all as per specified and directed. .
Supplying & Fixing switch piano flush button single pole one way 5 amps 230 volts, complete all as per specified and directed.
Supplying & Fixing fan regulator electronic flush type stepped (rotary type) with 5 steps speed control complete all as per specified and directed.
Supplying & Fixing socket out let, 5 pin, 5 amps, 230 volts, complete all as per specified and directed.
Supplying & Fixing socket out let, 6 pin, 5 and 15 amps, 230 volts, multi purpose 2 in 1 flush typecomplete all as per specified and directed.
Supplying & Fixing switch socket combination 2 in 1, 5 pin, 5 amps, 230 volts,flush type complete all as per specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate having matching colour to holder suitable for angle/batten fittings complete all as per specified and directed.
S&F ceiling rose surface bake lite two to three terminal isolated body fixed on PVC round block complete all as per specified and directed.
S&F modular switches 6 amps, 01module single pole one way complete all as specified and directed
S&F modular switches 16 A , 01 module single pole one way complete all as specified and directed
S&F modular socket out let 6/16 A 2/3pin combined 2 module complete all as specified and directed
S&F modular socket out let 6/10 A 2/3pin combined 2 module complete all as specified and directed
S & Fof mudular type electronic fan regulator 5 steps, 120 W-2 module suitable for 240 volt AC complete all as specified and directed
S&F modular white cover platewith frame 8 modular complete all as specified and directed.
S&F modular white cover platewith frame 6 modular complete all as specifed and directed by engineer-in-charge.
S&F modular white cover platewith frame 4 modular complete all as specifed and directed
S&F modular white cover plate with frame 3 modular complete all as specifed and directed .
S&F modular white cover plate with frame 2 modular complete all as specifed and directed .
S&F modular white cover platewith frame 1 modular complete all as specifed and directed .
S&F in replacement LED 20 watt batten tube light fitting with polycarbonate diffuser, 4 feet fitting fixtures, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as per specified and directed. Havells catpart:LUMILINEPLUSNEOBS20WLED830SPCSSIND or equivalent in Bajaj/Philips/Wipro/HPL
S&F in replacement LED 10watt batten tube light fitting with polycarbonate diffuser, 4 feet fitting fixtures, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as per specified and directed. Havells cat part No: LUMILINEPLUSNEOBS10WLED865SPCSS or equivalent in Bajaj/Philips/Wipro/HPL
Supply and fixing Plug and socket box with plastic plug with MCB SP 32Amp for AC socket complete all as specified and directed.
Taking down ceiling fan/Exhaust fan, and deposting the same in MES store for painting and refixing the same complete all as specified and directed.
Supply and fixing inreplacement LED 36 Watt Aesthetically designed LED flat panel for surface mounting which provides soft light and glare free symmetrical illumination 2 x 2 feet size fixed on ceiling with all accessories connecting up with three core twisted flexible copper conductor cable of suitable size complete all as per specified and directed. Havells cat part No:VENUSNEOHE4X1PLR36WLED857S or equivalent in Bajaj/Philips/Wipro/HPL
S&F in replacement sheet metal powder enclosure powder coated versatile double door single pole and neutral (SPN) 8 way fitted with copper bus bar rated 200 Amp (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link , earth bar complete all as per specified and directed.
S&F in replacement sheet metal powder enclosure powder coated versatile double door single pole and neutral (SPN) 4 way fitted with copper bus bar rated 200 Amp (SPN) distribution board for MCB provisions 230Volt, 50Hz AC with neutral link , earth bar complete all as per specified and directed.
S&F in replacement double door TPN vertical loadline DBs are fitted with bus bar, neutral links, blanking plate with MCCB four pole 100Amp, 25KA, 415Volts supply having protection IP-43 with GI frame fitting on wall with anchor, fastener and connect all electrical connections complete all as per specified and directed.
S&F MCB SPN 40 Amps with 10KA breaking capacity of c- series in distribution board complete all as per specified and directed.
S&F MCB SP 6-32 Amps with 10KA breaking capacity of c series in distribution board complete all as per specified and directed.
S&F MCB TPN 63 Amps with 10KA breaking capacity of c series in distribution board complete all as per specified and directed.
S&F in Replacement of existing sub main wiring with two run of single core (FRLS) PVC insulated and unsheathed cable with copper conductor (Multi strand) having nominal area 4.0 Sqmm drawing into and including PVC non metallic rigid conduit of adequate size and making electric connections including one run (FRLS) PVC insulated single core copper conductor cable 4.0 Sqmm as a earth continuity conductor(green colour) in and including in non metallic rigid PVC conduit, including cutting chases in brick wall, replastering and making good to match the existing specifications complete all as per specified and directed. Note :- (i) Rates are deemed to be included chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit (ii) Two run of 4.00 sqmm single core (FRLS) PVC insulated copper conductor cable one run of 4.0 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit of suitable size will be measured as a one unit.
Material & labour for Electrical earthing with GI plate electrode of size 60 cm x 60 cm x 6.3 mm thick burried directly in ground vertically earth pit not less than 2.5 mtr deep below ground level with the top edge of the earth plate at a depth not less than1.5 mtr below normal ground level connected to GI strip earth lead of size 25 x 4 mm by means of bolts, nuts, washers made of galvanised iron and connected main control board/switch gear/pannel boards all as specified and shown in electrical Plate No.3 of MES schedule (SSR) Part-I 2009 including necessary excavation and earth work in any type of soil, charcoal dust, salt and PCC 1:2:4 type B1 in chamber RCC 1:2:4 type B1 coverl slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways and with 6 mm dia MS hook complete and testing resistance all as specified and as directed.
WALIA ENTERPRISES (BID ID -3094042)
Ashoka Engineers (BID ID -3092984)
pardeep singh marwaha (BID ID -3094315)
G.M. ENGINEERING SERVICES (BID ID -3092941)
Ms International Engineers (BID ID -3094161)
KHOSLA ENGINEERS BUILDERS (BID ID -3094136)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .