Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84.0 CrAccepted-AOC DADRA AND NAGAR HAVELI DN | DADRA AND NAGAR HAVELI | THE DADRA AND NAGAR HAVELI AND DAMAN AND DIU | 396193 | ₹84.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹85.9 CrRejected-AOC | ₹85.9 Cr | L2 | Rejected-AOC L2 |
Tender Value
₹60.9 Cr
EMD Value
₹70.9 L
Closing Date
9 Jan 2023, 12:00 pmClosed
Executive Engineer, Project Cell, PWD,DNH,Silvassa
PWD Campus Block No.I,DNH,Silvassa
Construction of Additional Academic Block and Hostel in the Medical College Campus at Sayli, DNH. (3rd Call)
2022_UTDNH_6250_1
E-TENDER NOTICE NO.40 OF 2022-23 (Bldg)
Open Tender
Civil Works - Buildings
730 days
UT OF DNH
As per NIT refer
3 documents required · 3 mandatory
₹5,000
Executive Engineer, Project Cell, PWD,DNH,Silvassa
₹70.9 L
Silvassa
29 Mar 2023
20 Dec 2022
9 Jan 2023
20 Dec 2022
9 Jan 2023
20 Dec 2022
27 Dec 2022
Amount
CIVIL WORKS Sec.1.0 Earth work Providing material, labour, machinery for Excavation of foundation upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth including back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Excavation of foundation from 1.5 mt to 3.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth including back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Excavation of foundation from 3.0 mt to 5.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth including back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Excavation of foundation from 5.0 mt to 7.0 mt depth including sorting out and stacking of useful materials and disposing off the excavated stuff with in/ out side the campus upto 1.0 Km lead, all lift/ depth including back filling the trenches, sides of foundations, plot filling, plinth filling with excavted material (excluding hard rock and black cotton soil) anywhere from the site/ campus etc complete as directed by Engineer in charge. - Any type of soil or rock not requiring Blasting.
Providing material, labour for Disposing off the un-used excavated stuff (black cotton soil, debries, of above items for all lead and lift/ depth outside the campus at non objectional place or as directed by Engineer in charge.
Providing material, labour for Filling in plinth with sand under floors including watering, ramming, consolidating etc complete as directed by Engineer in charge.
Providing and injecting Chemical emulsion for PRE - CONSTRUCTIONAL anti-termite treatment and creating a chemical barrier on the top surface of plinth filling, inside junction of wall and floor, on top of damp proof course or on masonry at level of plinth filling as per IS 6313 (Part-2)-2013 using chemical like Imidacloprid 30.5% SC (CIB approved) and proportion of dilution with water shall be as per manufacturer's specification. The emulsion shall be applied as mentioned below, all as per specification and directions of Engineer-in-charge. Plinth area in plan at GF shall only be measured and paid. A guarantee bond of 10 years shall be furnished in prescribed proforma. Rate shall be inclusive of material required for Anti Termite Treatment and labour and equipment's required for applying in any condition all etc. complete as directed by engineer in charge. (Stage of treatment may vary as per site condition. Contractor shall get the same approved by Engineer in charge before execution.) a) Treatment to soil below raft - Before laying the PCC, the compact and levelled soil shall be treated at 5 liters per sq m. OR In case of soils/sand filled above the raft, the treatment at 5 liters per sq m shall be carried out on the top surface of filled soil/sand. b) Treatment to soil along the retaining wall - The soil retained by the walls (soil coming in contact with retaining wall) shall be treated at the rate of 7.5 liter per sq m of the vertical surface in full depth. c) Treatment of soil along external perimeter of building - After the building is complete, the earth along the external perimeter of the building shall be rodded at intervals of 150 mm and to a depth of 300 mm. The rods shall be moved backward and forward, parallel to the wall to break up the earth and emulsion poured along the wall at the rate of 7.5 liter per square meter of vertical surfaces. d) Top surface of the plinth filling including damp proof courses at the rate of 5 liter/sqm of internal plinth area ( As per IS:6313 Part II-2013). For any area without basement, treatment shall be done as per IS:6313 Part-II-2013. e) Treatment of soil surrounding pipes, wastes and conduits - When pipes, wastes and conduits enter the soil inside the area of the foundation, soil surrounding the point of entry shall be loosened around each of such pipe, waste or conduits for a distance of 150mm and up to a depth of 75 mm before the treatment is commenced. When they enter the soil external to the foundation, they shall be similarly treatment for a distance of 300 mm, unless they stand clear of the walls of the building are about 75 mm. f) 1 liter / linear meter along the junction of wall and floor at all stages g) 2 litre per linear meter for expansion joints in touch with soil/sand. Foot print area of Ground Floor of the building (in sqm) shall be considered for payment as complete item.
Sec: 2.0 PCC & RCC works Providing material and labour for laying Autoclave Aerated Concrete Block chips/ bats cement concrete in 1:4:8 (1 Cement : 4 Coarse Sand : 8 graded Autoclave Aerated Concrete Block chips/ bats) for sunk filling grade including compacting, finishing, curing etc. complete as directed by engineer in charge.
Providing material and labour for laying Plain cement concrete 1:3:6 (1- Cement : 3- Coarse sand : 6- crushed stone aggregates 20 mm nominal size) in Foundation and Plinth including compacting, finishing, curing, formwork (if required), etc complete for all level, all height/ depth as directed by engineer in charge.
Providing material and labour for laying machine batched, machine mixed Plain cement concrete M15 in Foundation and Plinth including producing in batch mix plant, transporting to site by continuous agitating mixer, pumping by any means, compacting, finishing, curing, formwork (if required), etc complete for all level, all height/ depth as directed by engineer in charge.
Providing TMT Bar FE 500D reinforcement for R.C.C. work including cutting, bending, binding (with 18 SWG -1.22 mm GI wire) and placing in position complete for all floors, all levels, all heights/ depth complete as per drawings, specifications and direction of Engineer in Charge.
Providing material and labour for laying machine mixed, machine batched controlled cement concrete M-20 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregates conforming to latest IS 383 with minimum cement content as per IS 456 (without fly ash) for durability shall be followed as per approved design mix and latest IS 456 for reinforced concrete work for all elements, all floors, any heights/ depths, any lead and lift including cost of formwork, scafolding, staging, vibreting, compacting, finishing, curing but excluding the cost of reinforcement etc complete as directed by engineer in charge.
Providing material and labour for laying in position Ready Mixed M-20 grade concrete for reinforced cement conctere for Grade slab work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere for Columns, Pillars posts, Mullion, struts work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere for Beams, Lintels, Runner, Girders, pile-cap work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere for Slabs, staircase, landing, shelves, chhaja, cantilever work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-25 grade concrete for reinforced cement conctere for any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere for Foundations, footings, Base of columns and mass concrete work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere for Columns, Pillars posts, struts work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere for Beams, Girders work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-30 grade concrete for reinforced cement conctere for any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere for Columns, Pillars posts, struts work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for laying in position Ready Mixed M-35 grade concrete for reinforced cement conctere for any type of wall work, using cement content as per approved Design Mix without Fly Ash (Min cement content as per latest IS 456 for durability) manufactured in fully automatic batching plant and transporting to site by continuous agitating mixer, pumping by any means from transit mixer to site of laying; cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability; finishing, compacting, vibrating, curing etc including cost of Form work, scafolding, staging but excluding the cost of reinforcement etc complete for all elements, all floors, any heights/depths, any lead and lift as directed by Engineer Incharge.
Providing material and labour for fixing in position pre-moulded compressible, high performance closed cell, bitumen free expansion joint filler board of 100mm thick in black colour of approved make, having minimum density 95 Kg/ Cum, non staining with less than 0.08% water absorption & compression recovery of 92% (conforming to MORTH specification clause 1015) minimum as per specifications including cutting to required size and shape, at all levels/ all floors/ all heights, etc. complete, as per drawings/ specification and as directed by Engineer in Charge.
Providing material and labour for fixing in position pre-moulded compressible, high performance closed cell, bitumen free expansion joint filler board of 50mm thick in black colour of approved make, having minimum density 95 Kg/ Cum, non staining with less than 0.08% water absorption & compression recovery of 92% (conforming to MORTH specification clause 1015) minimum as per specifications including cutting to required size and shape, at all levels/ all floors/ all heights, etc. complete, as per drawings/ specification and as directed by Engineer in Charge.
Providing material and labour for filling the expansion joints groove of size 50mm x 12.5 mm, with exterior grade one component PU sealant with application of primer including scraping/ removing the expansion filler materials from joints, cleaning, repairing of the edges with epoxy mortar of approved colour and make, placing of backup material (polyethylene baker rod), fixing of abro masking tapes on the edges to prevent the adjoining surface, at all levels/ all floors / all height etc. complete as directed by engineer-in-charge.The PU sealant shall have minimum tensile strength of 1.5 N/mm2, minimum 600% elongation at break, 75% elastic recovery (after 28 days), tear propagation resistance of 8 N/mm and resistant to water, diluted alkalis, cement grout, water dispersed detergents etc The contractor shall furnish a performance guarantee of 10 years against leakage, debonding from the edges.
Providing material and labour for fixing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for 50mm diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer in charge.
Providing material and labour for fixing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for 75mm diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer in charge.
Providing material and labour for fixing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for 110mm diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer in charge.
Providing material and labour for fixing in position rigid PVC pipe sleeves of 6Kg/cm2 and length as per design for 160mm diameters for services wherever pipes pass through walls/ slabs/ beam before concreting. All pipes shall be accurately cut to the required sizes, laid as per drawing, kept in the position while laying reinforcement and shuttering, sleeves shall not get displaced while concreting, and burrs removed before laying. Open ends of the pipe shall be closed as the pipe is installed to avoid clogging while concreting. Measurement shall be taken up to two decimal. (minimum 0.01 mt.). Rate shall be inclusive of removal of sleeves before water proofing or grouting. For all floors/ all levels/ all heights. Location of sleeve shall be approved by Engineer in charge.
Providing material and labour for wet drilling accurate and clean holes of 52 to 77mm diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge etc compete. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. (Actual depth of core cutting shall be measured for payment)
Providing material and labour for wet drilling accurate and clean holes of 77 to 102mm diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge etc compete. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. (Actual depth of core cutting shall be measured for payment)
Providing material and labour for wet drilling accurate and clean holes of 102 to 125mm diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge etc compete. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. (Actual depth of core cutting shall be measured for payment)
Providing material and labour for wet drilling accurate and clean holes of 125 to 152mm diameter in RCC walls, slabs, beam or any other RCC member without vibration by core cutting (diamond drilling) machine of approved make for laying service lines including scaffolding, safety majors, disposing the debris, cleaning, making good, providing epoxy mortar/ micro concrete/ patch repair mortar/ Non shrink grout for concrete for grouting the gaps around the pipes for all levels/ all height, after approval of engineer in charge etc compete. Measurement shall be taken for the depth of holes in running meter for specified diameter. Holes shall made by authorized approved agency. Scanning of reinforcement shall be carried out before core cutting if required and as suggested by Engineer in charge. Location of core cutting shall be approved by Engineer in charge. (Actual depth of core cutting shall be measured for payment)
Chemical Anchor: Providing material and labour for Drilling, Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 10mm and depth 150mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
Chemical Anchor: Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 12mm and depth 180mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
Chemical Anchor: Providing material and labour for Drilling/ Cleaning hole and injecting grouting chemical with the help of dispenser, into a hole of dia 16mm and depth 240mm as per manufacturer/ structural consultant's specification and fixing rebar of the required diameter subsequently. Fixing methodology shall be followed as per manufacturer’s guidelines. Steel will be paid under relevant item. Manufacture to submit Rebar Depth Calculation based on design loads & other parameters as provided by consultant and in accordance with EOTA-TR-023/029 “guidelines for post installed rebar connections” for approval. Rate shall be inclusive of all material, labour, necessary scaffolding etc complete for all floors, all height as directed by engineer in charge.
Providing material and labour for fixing of expansion joint system (tray/ pan type) for 100mm wide gap of approved make, related with floor location as per drawings and direction of Engineer-In-Charge. The joints system shall be of extruded aluminum base members, self aligning/ self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor/ floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and match with finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates/ moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design. (Material shall conform to ASTM 6063). Rate shall be inclusive of stone fixing in between the system as per drawing. Cost of stone shall be paid in relevant tender item. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as directed by engineer in charge.
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with internal wall and ceiling joint location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner/ ceiling application, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063). Rate shall be inclusive of polyester powder coating (min 50 micron) of approved shade and make. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as dircted by Engineer in charge.
Providing material and labour for fixing of expansion joint system for 100mm wide gap of approved make related with External wall joint location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning/ centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner, with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall conform to ASTM 6063). Rate shall be inclusive of polyester powder coating (min 50 micron)of approved shade and make. Expansion joint system shall be as approved for all floor all level including scafolding etc complete as dircted by Engineer in charge.
Providing material and labour for fixing machine moulded aluminium covering of approved pattern & design, made out of machine cut aluminium sheet and machine holed for receiving dash fastener, over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm long bolt including providing aluminium washers 2 mm thick & 15 mm dia , at a staggered pitch of 200mm centre to centre including drilling holes in the receiving surface and providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-charge.
Sec.3.0 Centering & Form works Providing material and labour for formwork for exposed concrete surfaces (Only extra addition cost on normal shutering) (vertical or horizontal surface) in smooth finish, desired pattern and size as per drawing and specifications, including rendering with white cement and grey cement, using laminated shuttering plywood, steel plate of required size, FRP material or any approved system for all types RCC elements like slabs, walls, columns, beams, folded staircase (all sides), sill, coping, lintels, jambs, beam hunching, vertical fins, pardi etc. including neat cleaning the exposed concrete surface, as directed by the engineer-in-charge. In case of round window opening in exposed RCC wall, for payment of expose shuttering opening cutout shall not be deducted (both side). Rate shall be applicable for all floors, all levels, all places and all shapes. The contractor shall submit shuttering pattern including tie-rod hole and groove position based on architectural conceptual drawings. (Same kind of shuttering material shall be only used for standard and residual sizes.)
Sec.4.0 Masonry works Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in foundation and plinth/ Upto basement Floor in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Ground Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for First Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Second Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Third Floor at any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Fourth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Fifth Floor at any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying Brick work using common burnt clay building Conventional bricks having crushing strength not less than 35 kg./Sq.Cm. in Cement Mortar 1:5. (1- Cement : 5 -fine sand) in superstructure above plinth level for Sixth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in foundation and plinth/ Upto Basement Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Ground Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for First Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Second Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Third Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Fourth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Fifth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Half brick masonry in common brunt clay building Conventional bricks having crushing strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -coarse sand ) in superstructure for Sixth Floor in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Ground Floor in cement mortar 1:5 (1 cement : 5 fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For First Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Second Floor in cement mortar 1:5 (1 cement : 5 fine sand) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Third Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Fourth Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Fifth Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Sixth Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Seventh Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Eighth Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Ninth Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying Masonary work using Aerated light weight concrete block having crushing strength not less than 35 kg/sqcm for super structure For Tenth Floor in cement mortar 1:5 ( 1 cement : 5 fine sand ) in any shape and thickness including finishing, racking of joints, curing, scaffolding for all height all level etc. complete as directed by engineer-in-charge.
Providing material and labour for laying of hollow concrete block masonry for jali work madeout from M20 grade 200mm thick hollow block of different size to cerate a pattern as per drawing confirming to IS 2185 Part I grade A (7.0), shape of hollow part shall be round, square or rectangle. Jali wall shall be constructed in cement mortar 1:2 (1 cement : 2 coarse sand) by providing 2 no of 6 mm dia. GI bar at each layer vertically as well as horizontally. GI wire/ rod shall be anchored in adjoining surface with quick fix chemical including roughening, cleaning, fixing and finishing/ rendering in grey and white cement sand mortar 1:1 in the line and level and in pattern including finishing, curing at all heights with necessary scaffolding etc complete as per the drawing and direction of Engineer in charge. Note: Payment shall as per actual area of jali made out of hollow block, no deduction of hollow gap of block shall be consider for payment.
SEC:5 Doors and Windows work ALUMINIUM WORKS - Providing material and labour for fixing in position frames/ shutter for any type of aluminium work for any type of door, window, partition, fixed louvers, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors/ all levels/ all heights/ all shapes/ all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections shall only be measured and shall be considered for the payment. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with a spring for rapid and secure joint assembly for casement and sliding shutter and frame; 2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Anchor fasteners of approved make for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of section for connecting style and horizontal rails; 6) providing and fixing packing at every 600mm c/c of average 6 mm PVC shims; 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installed hardware in door shutter and frame as and when required but excluding. 1) necessary hardware; 2) Glazing or Infill material.
Providing material and labour for fixing 6mm thick Clear Toughen Glass as per approved sample of any size, any shape in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 8mm thick Clear Toughen Glass as per approved sample of any size, any shape in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 10mm thick Clear Toughen Glass as per approved sample of any size, any shape in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing 12mm thick Clear Toughen Glass as per approved sample of any size, any shape in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
Providing material and labour for process charges of Frosting the glass (any thickness of glass in any pattern) as per drawing and as directed by engineer in charge. Rate shall be for only for extra cost of Forsting on Glass for all floor, all height all level.
Providing material and labour for fixing 6mm thick Wired Glass of any size, any shape in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing with EPDM quality rubber/ silicon sealant/ structural sealant on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Architect. Actual installed quantity shall be measured and paid. Rate shall be inclusive of all type of wastage.
Providing material and labour for fixing 6mm thick Compact Sheet of any size, any shape, any color, any texture of approved make and as per approved sample (approved by architect). Compact sheet shall be fixed in aluminium frame and shutter work with necessary cutting of sheet, single side, double side coloured as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ adhesive tape/ screwing on the periphery of the sheet as per the required thickness etc. complete at all floors/ all levels/ all heights as per the drawing & directed by Engineer in charge. Cut edges of the compact sheet shall be provided with masking tape. Actual installed quantity shall be measured and paid.
Providing material and labour for fixing in position SS 304 - 18 x 16 mesh and 32gauge Mosquito net of any size any shape having 50 micron pure polyster powder coating of approved make and shade in aluminium framing as per approved shop drawing prepared by contractor. Jali shall be fixed with SS304 grade screws and fasteners required to tighten the Jali/ Net including fixing channel, EPDM quality rubber/ silicon sealant etc complete for all floors, all levels, all heights as directed by engineer in charge. Only installed area of mosquito net shall be measured and paid in Sqm without considering any westage. All aluminium sections shall be paid under relevant tender item.
Providing material and labour for fixing factory made and factory pressed 35mm thick flush shutter (bare finish yhickness) made of ISI marked non decorative type flush door shutters, core of block board construction with frame of 1st class hard wood, pine filler and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters having laminates/ veneer (which paid separately) as per drawing, including providing and fixing external lipping with 6 mm wide and thicknes as per finish shutter made out of 1st class teak wood battens, on all exposed edges of door shutter as required with 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing to lipping as per drawing etc complete for all floor all level as directed by Engineer-in-charge. Cost of veneer/ laminates and all fixture/ hardware shall be paid in relevant tender items.
Providing material and labour for fixing factory made and factory pressed 25mm thick flush shutter (bare finish yhickness) made of ISI marked non decorative type flush door shutters, core of block board construction with frame of 1st class hard wood, pine filler and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters having laminates/ veneer (which paid separately) as per drawing, including providing and fixing external lipping with 6 mm wide and thicknes as per finish shutter made out of 1st class teak wood battens, on all exposed edges of door shutter as required with 2 coats of synthetic enamel painting including 1 coat of wood primer & lapi/ lacquer polishing to lipping as per drawing etc complete for all floor all level as directed by Engineer-in-charge. Cost of veneer/ laminates and all fixture/ hardware shall be paid in relevant tender items.
Providing material and labour for fixing 1 mm thick Laminate sheet of approved make and shade on Non decorative flush door, panelling work, fixed partition, any ply surface etc with necessary nails, screws, adhesives as per drawings and as per approved sample. Laminate shall be either glossy, matt, Swede or any type of texture finish. The rate shall be for all heights, all floors, all places etc complete as directed by engineer in charge. Actual laid area shall be measured and paid without considering any westage.
Providing material and labour for fixing vision panel made out of 5mm thick clear toughen glass of any shape any size in all type/ thickness of flush doors shutter. Glass shall be fixed with teak wood lipping (Lacquer polished of approved make and shade) on both side the door of required size as shown in drawing and direction of Engineer-In-Charge. Rate shall be includes the cost of cutting door, provision of glass with both side lipping, polishing, making good for all floor, all level, all height etc complete. The actual installed area of vision panel shall be measured for payment.
Providing material and labour for fixing 6mm thick frame less mirror of approve make in any shape and sizes as per drawing. Mirror shall be fixed on 6mm thick cement bonded particle board (Bison panel) backing. Cement bonded particle board shall be fixed to wall with approved SS 304 fastener. All edges of glass shall be sharp grinded, cute corner and polished. Glass shall be fixed with silicon sealant/ 3M tape etc complete at all floors/ all levels/ all heights as directed by engineer in charge. Installed area of mirror shall be considered for payment without wastage. Rate shall be inclusive of cement board.
Providing material and labour for Extra charges for machined Perforation of any size, any pattern in flush door shutter/ compact sheet of any thickness as per drawing etc complete for all floor, all height all level and as directed by Engineer in charge. Edges of perforation shall be finished and smoothen.
Providing material and labour forfixing single/ double action hydraulic floor spring with SS 304 cover plate & adjustable concealed casted top pivot (two piece) and bottom strap of approved make for wooden/ aluminium doors of specified capacity with minimum one year guarantee. Rate shall be inclusive of cutting of floor neatly, grouting the floor spring & cleaning/ polishing the floor & maintaining in good working condition until defect liability period. In case of Aluminium shutter bottom arm of floor spring & top pivot shall be firmly fixed in the aluminium members using required size of teak wood by making rabbet in the wood. The Floor Spring shall conform to EN 1154. a) Hold open having weight up to 100 kg and shutter width upto 1200mm with std. spindle and cover plate. Closing force complying with EN 1154 2 - 4
Providing material and labour for fixing hydraulic rack and pinion door closer with standard/ parallel arm (Silver finish) of approved make, with SS 304 screws to door shutter of specified width with minimum one year guarantee. All adjustment screws face fixed. Rate shall be inclusive of fixing with using the template as per manufacturer’s specification & maintain in good working condition until defect liability period. The door closer shall conform to EN 1154 standard. a) with standard/ hold open arm with two independent closing valves and latching speed adjustable by arm without mounting back plate, Closing force complying with EN 1154 2 - 4 for up to 900 mm door shutter width
Providing material and labour for fixing SS-304 grade butt hinge of 100 x 75 x 3 mm - with ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.
Providing material and labour for fixing SS-304 grade butt hinge of 100 x 64 x 2.5 mm - without ball bearing of approved make as per approved sample with necessary screws etc. complete for all floor all height all level as directed by Engineer in Charge.
Providing material and labour for fixing set of dead lock of approved make with 55mm backseat, 20mm square for end with 72 mm centers including strike plate in satin stainless steel finish as per DIN 18251-1, grade 2 and prepared for euro profile cylinder (EPC) including strike plate and EPC length 60/70 mm standard Euro profile Pin Cylinder/ Half pin cylinder with both side key/ one side key one side knob operation with one pair of SS 304 Escutcheons (key hole plate) for wooden/ aluminium/ metal doors with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.
Providing material and labour for fixing SS 304 satin finished set of narrow style dead lock of approved make with 25mm /35 mm set back necessary euro profile pin cylindrical lock 60/ 70 mm for Key and or knob operation and one pair of SS 304 Escutcheons (key hole plate) for aluminium door with necessary SS Phillips head screws etc complete for all floor, all level, all height as per approved sample and as directed by engineer in charge. The lock shall be with 3 keys.
Providing material and labour for fixing Mortise lock of approved make having 72mm centre to centre, 55mm Backset 20mm Square forend and 60/ 70mm standard Europrofile Pin Cylinder with both side key /one side key - one side knob operation and SS 304 grade hollow tubular pipe pair of Mortise handle of 22mm dia 150mm long with a pair of SS 304 Escutcheons (key hole plate) for wooden /aluminium/ metal doors with necessary ss phillips head screws etc complete for all floor, all height, all level as per approved sample as directed by engineern in charge. The lock shall be with 3 keys.
Providing material and labour for fixing Tubular dead bolt for toilet door of approved make with necessary screws etc complete for all floor, all height, all level as per approved sample as directed by engineern in charge. The lock shall be with 3 keys.
Providing material and labour for fixing Mortise shaft dead bolt of approved make with key (Alen Key lock), sleeve with 57mm backset and 25mm square forend in stainless steel satin finish etc complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing indicator bolt of approved make for toilet door with Thumb Turn inside & Emergency Release & Indicator Outside with necessary screws etc complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 200 mm long x 19mm dia made out of satin (brush) finish hollow pipe of minimum 1.0mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle shall be perfect center to center as below specified.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 300 mm long x 22 mm dia made out of satin (brush) finish hollow pipe of minimum 1.0mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle shall be perfect center to center as below specified.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 450 mm long x 25 mm dia made out of satin (brush) finish hollow pipe of minimum 1.0mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle shall be perfect center to center as below specified.
Providing material and labour for fixing SS 304 grade push-pull pair of handle of size 600 mm long x 32 mm dia made out of satin (brush) finish hollow pipe of minimum 1.0mm thick having offset type (C or D shape)/ H-shape/ D-shape of approved make with necessary screws etc. complete for wooden doors/ aluminium doors/ metal doors for all heights, all floors and all level as per approved sample and as directed by Engineer-in-charge. Rate shall be The length of handle shall be perfect center to center as below specified.
Providing material and labour for fixing chromium plated brass/ SS 304 grade handles 150mm long D shape rod handle (approximate 10 to 12mm dia) of approved make with both end bracket with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing 25mm diameter (1.2mm thick) SS 304/316 satin (brush) finish Disabled Grab Rails/ handle of 600mm long of approved make with necessary SS 304 grade screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing of SS 304 brush finish 450mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing of SS 304 brush finish 250mm height Tower bolt (barrel type with minimum rod size shall be 10mm) of approved make in wooden doors/ aluminium doors/ metal doors with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing of SS 304 satin finish lever action Flush tower bolt with 19mm projecting bolt (extended rod of 600mm length) aluminum casted of approved make for double shutters aluminum door, with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing 250mm long (minimum rod size shall be 14mm and 110mm hanging handle) "J" type SS 304 brush finish Aldrop (sliding bolt) of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing & fixing 200mm long (minimum rod size shall be 12mm and 50mm hanging handle) SS 304 brush finish Tadi (sliding bolt with out locking hole) of approved make with necessary screws, pins, bolts etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for Fixing SS 304 satin finish 100mm long Baby Latch including Bracket of 35 mm x 38mm, with necessary SS Screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing SS 304 brush finish solid Door Stopper with/ without magnet, fixed type, wall mounted/ floor mounted of any shape and required length of approved make with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing SS 304 brush finish solid Door bufer with pvc base, wall/ shutter mounted (square/ round) of approved make with necessary screws etc. complete as approved by Engineer-in-charge in Charge.
Providing material and labour for fixing Aluminium powder coated butt hinges of required capacity of approved make for casement window/ door (europrofile) with necessary accessories, screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing stainless steel (SS 304 grade) adjustable friction windows stays of size 355 X 19 mm of approved make with necessary stainless steel screws to the side hung windows etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing powder coated two point lock with mortise handle (without lock) of approved make with heavy gear mechanism of required capacity including all required accessories like handle, fork, connector, extensior, polyamide, locking point, corner transmission and striker etc as per approved manufacturer recomendatation for aluminium casement door and window (top hung or side hung) with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing powder coated inbuilt flush handle (without lock) of approved make of required capacity including all required accessories like nib, counter plate etc as per approved manufacturer recomendatation for aluminium sliding window with necessary screws etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing adjustable/ fixed Teflon roller bearing set with reinforced nylon casing of required capacity and of approved make (twin or single wheel according to weight and size) for sliding window/door as per drawing etc. complete for all floor, all height, all level as per approved sample and as directed by engineer in charge.
Providing material and labour for fixing Hollow metal 2 Hour fire rated doors (120 minute integrity and 30 minute insulation) of approved make and in any shade any finish as per IS 3614 – 2021 for stability and integrity. Pressed Galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall have doors tested at CBRI or ARAI for maximum rating of 2hrs with minimum 30 mins insulation with vision panel. Test certificates shall be available for vision liters/ panels as part of the fire door assembly. Independent glass test certificates will not be accepted. Manufacturer test certificate shall cover doors both single & double leaf doors and hardware shall be of 120 minutes Fire Rating and third party approval certificate from reputed agency such as CERTIFIRE / UL etc. Any deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Approved manufacturer subject to Engineer – in- charge approval and shall be ISO certified company. Providing material and labour for fixing Fire rated Door frame shall be single rebate profile of size 125mm x 55 mm made out of 1.60mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be as per tested design and field assembled with self tabs. All provision shall be mortised, drilled and tapped for receiving appropriate hardware. Rubber door silencers shall be provided on the striking jamb. Frames shall be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Once frame installed shall be filled with PUF as recommended by the manufacturer or engineer. Door shutter and frames shall be finished with minimum 50 micron pure polyster powder coated and shall have passed minimum 500 hours of salt spray test. The door leaf and frame shall have passed minimum 500 hours of salt spray test as per the directions of Engineer - in- charge. Rate shall be inclusive of all above mentioned components including anchor fasteners.(Cost of SS ball bearing hinges is excluded).
Providing material and labour for fixing Fire rated Door shutter shall be 46mm thick fully flush double skin door with or without vision lite. Door shutter shall be manufactured from 1.2mm (18 gauge) minimum thick galvanized steel sheet. The internal construction of the door shall be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be high density insulation material with Intumescent seals and smoke seal as per IS:3614-2021. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges shall be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. Vision lite wherever applicable shall be provided for minimum 5mm thick fire rated glass as per manufacturer’s recommendation with a clip on arrangement. Door shutter and frames shall be finished with minimum 50 micron pure polyster powder coated and shall have passed minimum 500 hours of salt sprey test. The cost includes all above material, labour, finishing, fixing except Vision panel, and required hardware, which shall be paid in relevant tender item.
Providing material and labour for fixing fixed vision panel glass in fire rated door having minimum 5mm thick, 2 hour fire rated glass of approved make with a clip-on arrangement with ceramic/ fire rated gasket and as per manufacturers recommendation.
Narrow stile mortise lock with lever handle Providing and fixing narrow stile mortise lock with lever handle package complete set including lock, cylinder 1/2 Package with Pair of Lever Handle with cap, strike plate and escutcheons. Including narrow stile lock Sash lock with Backset as per door size 20mm Square forend. EPC 60/70mm length both side key operation or one side key and inside thumb turn with necessary screw etc. as approved by Engineer in charge.
Non Fire Rated Metal Door (Including Frame , Vision Panel and Shutter) Providing and fixing of non fire rated Hollow metal door at all levels from ISO 9001 -2000 certified Manufacturer. All hollow metal doors shall be fully metal with/ without vision panel or partly metal and partly glazed shautter. Pressed Galvanized steel Single/ Double leaf to required sizes of approved make which consists of frame, shutter, infill and finish as detailed below and conforming to IS 277. Door frame shall be Double rebate profile of size 100 x 50 mm made out of 0.8mm thick galvanized steel sheet (20 gauge). Frames shall be Mitered and field assembled with self tabs. Frames shall be fixed with back plate bracket and anchor fasteners of approved size and make for installation on a finished plastered masonry wall opening. Door shutter shall be 46mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (20 gauge) minimum thick galvanized steel sheet. The internal construction of the door shall be rigid with steel stiffeners/ pads and reinforcement. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. The edges shall be interlocked with a bending radius of 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. The vision glass (wherever applicable) shall be 5mm clear toughened glass, as per joinery details with a screw on glass beading on the inside. Shutter shall be fixed to frame with SS 304 Ball Bearing Butt Hinges of size 100mm x 75mm x 3 mm (no of hinge as suggested by engineer in charge). All door shutter and frames shall be finished with etched primer coating, stove zinc phosphate primer and thermosetting polyurethane aliphatic grade paint of approved colour. The door leaf and frame shall have passed minimum 250 hours of salt spray test. Rate shall be include supply and installation of door i.e frame, anchor fastener, shutter with vision lite, hinge but exclude the cost of hardware (other than hinge) etc complete as directed by engineer in charge. Out to out area of door with frame shall be measured for payment. Incase of partly glazed shutter, area of glass shall be deducted from measurement for payment and paid in relevant tender item. Shop drawing shall be prepared and submit by contractor and approved by Architect.
Providing and fixing SS 304 grade top bottom pair of Pivot of required capacity for door with all necessary ss phillips head screws etc complete as per drawing and sample approved by Architect/ EIC.
Frosted Film Providing and fixing in position PVC Frosting Glass film of 100 to 130 micron thickness approved make (of any pattern, shade and type) on glass partitions and doors for internal use. Film shall be pasted on glass without any appearing any air bubble. The rates shall be for all shapes and all heights with necessary scaffolding complete as per the Architectural drawings and manufacturer's specification & instructions as directed by the Engineer-in-charge. Film shall be with 10 years warranty.
Providing material and labour for fixing 120 min fire rated SS 304 Ball Bearing Butt Hinges 100mm x 75mm x 3 mm CE marked for fire rated metal door of approved make with necessary screws etc. complete as recommended by manufacturer for all floor all height and as directed by Engineer in Charge.
Providing material and labour for fixing Fire rated (120 minutes) Rack and pinion door closer having third party approval certificate from reputed agency such as CERTIFIRE / UL etc. with controlled adjustable closing speed and power adjustable with back check with track arm with screws to hinged door of approved make confirming EN grade 2-4 with minimum one year guarantee. All adjustment screws face fixed. Rate shall be inclusive of fixing with using the template as per manufacturer’s specification & maintain in good working condition. The door closer shall conform to EN 1154 standards and CE marked with necessary fittings etc. complete as recommended by manufacturer and as directed by Engineer in Charge.
Providing material and labour for fixing 1 point panic device in Contur design, carry bar for single door for fire and smoke check doors, with steel latch, security anti thrust latch for door widths upto 1300mm, consisting of 2102F, 2105 in silver finish of approved make. As per EN 1125, CE marked etc. complete for all floor, all height as recommended by manufacturer and as directed by Engineer in Charge.
Providing material and labour for fixing External trim with lever handle of approved make suiting the panic bar for fire and smoke check doors prepared for half euro profile cylinder and in Silver finish with necessary fittings etc. complete for all floor all height as recommended by manufacturer and as directed by Engineer in Charge.
Providing material and labour for fixing 75mm thick wooden Asbestos Free Accoustic cum fire/smoke door of 120 minutes fire rating, conforming to BS: 476 part 22 IS: 3614 part -II, suitable to achieve apprrox. 32db, sound reducing properties suitable for fixing in wooden door frame of suitable section 140X90mm made out of Hardwood and the shutter comprising of 2 non -combustible boards sandwiching 41 mm thick fire resistant & accoustic insulation filler. The shutter is faced with 6mm thick commercial ply and 1mm thick Laminate on both faces and Hard wooden lipping all around the shutter. The frame shall be fitted with fire & smoke intumescent seal of size 10 x 4mm on all the three sides except bottom and shutter shall be fitted with fire & smoke intumescent seal of size 20 x 4mm on all the three sides except bottom. Auto drop down seal shall be fixed at bottom of each shutter. The shutter is fitted with the frame with the help of SS 304 ball bearing hinges of size 125x89x3mm (04 nos. per leaf) including all type of accoustic seal. Rate shall be inclusive of wooden frame, door shutter, laminates, all type of seals, SS 304 grade heavy duty hinge, necessary SS 304 anchor fastner etc complete. Finishing i.e. laminate, polishing shall be paid in relevanrt tender item.
Sec.7.0 Plastering & Pointing works Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Ground Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for First Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Second Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Third Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fourth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fifth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Sixth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Seventh Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Eighth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 10mm thick mala cement plaster in single coat on ceiling & stairs and soffits plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Ninth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Ground Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for First Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Second Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Third Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fourth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 15mm thick cement plaster in single coat on sides of brick work/ blocks wall/ RCC work for interior plastering and finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand) for Fifth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished upto Basement Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Ground Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for First Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Second Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Third Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Fourth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Fifth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Sixth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Seventh Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Eighth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for laying 20 mm thick internal/ external double coat mala cement plaster on interior brick/ concrete work for plastering comprising of base coat of 12 mm thick cement plaster in cement mortar (1 Cement : 4 coarse sand) in rough finishing and 8 mm thick top coat of cement mortar 1:2 (1 Cement : 2 Coarse sand) smooth trowelled finished for Ninth Floor with necessary scaffolding, curing, finishing, making grooves, forming pattas, hacking properly to RCC surface etc. complete as directed by the Engineer-in-charge.
Providing material and labour for fixing G.I. hexagonal chickenmesh of size 20mm x 20mm of 22 gauge at junction of concrete and brick work or between different materials (min 100mm on both side of junction) after making "V" grove between two different material surface and filled with rich cement mortar including necessary "U" nails/ screws/ washers with cleats for fixing, overlaps, curing, scaffolding etc complete for all floors/ all levels/ all heights/ all shapes as per direction of Engineer-in-charge.
Sec.8.0 Waterproofing works Providing material and labour for laying average 18mm thick double coat (water proof) smooth/ wired finish cement plaster on sides of masonry work/ block wall/ RCC wall, 12 mm thk first coat in CM 1:3 (1 cement : 3 coarse sand) by spraying , second coat of 6 mm of CM 1:3 (1 cement : 3 fine sand) and mixing Integral waterproofing liquid admixture of approved make for mortar in recommended proportions in both coats, finishing the surface wired finish/ smooth finish with a floating coat of neat cement slurry at 2.75 Kg/ sqm for all floors, all shapes and all height including hacking to RCC surface, scaffolding, curing etc. complete for all floor, all height as directed by engineer-in-charge. Cement slurry admixed with Integral waterproofing liquid admixture for mortar in recommended proportions is to be applied before each coat and final finishing coat.
Providing material and labour for laying average 50 mm thick IPS, water proof cement concrete flooring in 1:2:4 (1 Cement : 2 Sand : 4 Graded Aggregate 10mm Nominal size) to RCC water tanks/ planter/ sump etc at all heights in line, level and gradient including mixing water proofing compound of approved make in recommended proportions suggested by manufacturer and as approved by Engineer-in-charge and leaving the surface rough wired finish to receive any type of flooring / smooth finish etc complete for all floor all height as directed by engineer in charge.
Providing material and labour for laying integral cement based water proofing treatment (India type brick bat) including preparation of surface as required for treatment of roofs, balconies, terraces etc with average thickness of 120 mm and minimum thickness at khurra as 65 mm and consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/ brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in- charge including laying glass fibre cloth of approved quality in top layer of mortar and finally finishing the surface with wired finish to receive china mosaic flooring. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge for all height all level. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.
Toilet waterproofing Providing material and labour for carrying out waterproofing treatment to sound concrete surface of toilets, sunken slabs, corridors, wet areas etc. after proper surface preparation to remove loose dust, dirt etc., repairing of cracks (if any) using polymer modified mortar, carry out cementitious injection grouting at leakage points modified with Plasticized Expandive Grout Admixture @ 225 gms per bag of cement, carry out 50 mm thick cement mortar (1:3) vatta/ fillet with Polymer bonding agent at dosage of 2.5 Ltr per 50kg cement, Pre-dampening concrete surface, mixing and application of two coats of Elastomeric Polymer modified cementitious waterproofing coating by incorporating alkali resistance 45 gsm glass fibremesh between 1st and 2nd coat using suitable brush or roller as per coverage etc. complete for all floor al height all level as per manufacturer’s specification and as directed by engineer in charge. Cured Polymer modified cementitious waterproofing coating shall comply with ASTM D4060, ASTM D4541, ASTM D638,ASTM C836 and possess below properties: Mixed density: 1.68 g/cc, Adhesion to concrete-> 1 N/mm2, Non-toxic, Static crack accommodation-1 mm Water proofing system shall be executed by only approved applicator of approved brand and under strictly supervision of technical fellow of manufacturer. The rate includes giving 10 year guarantee for waterproofing on a Rs.100/- stamp paper in approved proforma.
Hole Packing treatment on service line Providing material and labour for applying total packing treatment on any type of pipes comes into water proofing area for all floor, all height as directed by engineer in charge as follows : Preparing the inside surface of core and Pipe by roughening using suitable Sand paper to get better adhesion prior to packing works. Cleaning the surface by wire brushing followed water jet to remove any laitance or loose flaky particles. Applying a coat of styrene- butadiene based polymer coating using Polymer bonding agent to enhance adhesion between the packing material and other surfaces. Packing the gap using Non shrink cement polymer based grout upto the surface of the bore before application of water proofing treatment. Treatment shall be executed by same agency with same manufacturer's product. Warranty includes in water proofing item.
Providing material and labour for applying hydrophilic crystalline based waterproofing for concrete walls, raft (basement and under ground water tank) with system In two coat application. The application to be done from + ve (positive) side on a wet open pore green concrete surface at coverage of 0.8 to 1 Kg/Sqm as per manufacturer specification. It shall be hydrophilic in nature, shall be able to grow crystals year after year to seal microcracks.The product shall confirm to DIN 1048 part 5 and shall provide in depth crystallization. The product technology shall be CPWD and EIL approved. Application shall be done on wet surface after 3-6 hours of casting of concrete. The material and application warranty to be given by manufacturer’s authorized distributor/ applicator on prescribed format. Rate shall be inclusive of construction joint treatment, crack repair, patch repair, grouting, including cost of scafolding for all height all level as directed by engineer in charge.
Providing and applying of controlled swellable type water stop bar (20 mm x 10 mm), non-bentonite type (expansive nature) of approved make for construction joints treatment of RCC structure, such as raft slab, retaining walls, water storage tank and at the junctions of raft slab with the retaining walls etc. For provision of swellable bar, contractor shall provide shear key in wall and raft. After cleaning the shear key, one coat of required primer for swellable water stop tape shall be applied throughout the length of the joint as per manufacturer specification. Over the primed surface swellable type water stop bar shall be placed. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge.
Sec.9.0 Flooring works Providing material and labour for laying Ceramic tiles 6mm thick in floor area of water tank, sump etc on existing levelled concrete surface, jointed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints with epoxy grout of approved make and shade including curing, finishing etc complete for all floors any heights, as directed by Engineer In charge.
Providing material and labour for laying Ceramic tiles 6mm thick on wall surface of water tank, sump etc on existing levelled plastered surface, jointed with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints with epoxy grout of approved make and shade including curing, finishing etc complete for all floors any heights, as directed by Engineer In charge.
Providing material and labour for laying 25mm thick (average) polished Kota stone slab (as per approved sample) in flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge.
Providing material and labour for laying polished kota stone slab 8-10 mm thick in risers of steps, skirting, Dedo and pillars laid on minimum 10mm thick cement mortar 1:3 (1-Cement : 3 coarse sand) and jointed with gray cement slury mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift etc complete as directed by Engineer In charge.
Providing material and labour for laying 25 mm thick mirror polished machine cut kota stone slab of size upto 2.0mt length with uniform thickness for flooring, skirting, tread, riser, window jambs, coping over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) laid over and jointed with gray cement slurry including champhering in same gauge of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. All Expose edges of stone shall be chmphered with same thickness and polished at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying cement concrete pavement (of any thickness) with 1:2:4 (1-cement : 2-coarse sand : 4-stone aggregate 20mm nominal size) including curing, finishing with floating coat of neat cement complete at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing material and labour for laying 8 to 10mm thick full body vitrified tile having size 600mm x600mm of approved make, shade, and finish (antiskid and matt finish as per approved sample) for flooring, otta, Skirting over 20 mm (average) base of cement mortar 1:5 ( 1 cement: 5 coarse sand) on new surface and fixed with cement slurry including finished with flush pointing with cement slurry with matching pigment, curing, protecting, cleaning the surface for all floors all heights, etc complete as directed by Engineer Incharge.
Providing material and labour for laying 8 to 10mm thick, full body Vitrified tiles (of any shade glossy or satin finsh) of size upto 600mm x 600mm of approved make, shade and finish (glossy, satin, or matt finish as per approved sample) in skirting, dado, risers of steps, jambs as per drawings. Wall tile is to be fixed over 10 to 12 mm thick wired finish plaster in cement mortar 1:3 (1 cement : 3 coarse sand) and average 6mm thick 1:1 cement sand mortar including pointing in white cement mixed with pigment of matching shade etc including curing, cleaning with mild oxalic acid, maintaining till handling over at all floors any heights, any lead and lift etc complete. as directed by Engineer Incharge. Rate shall be inclusive of base palster.
Providing material and labour for laying approved quality mirror polished average 18mm thick Granite of approved shade in floor, otta, sill, skirting in any pattern etc sizes upto 600mm including average 20 mm thick cement mortar bedding in 1:5 laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC and as per approved sample and as directed by Engineer in charge at all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.)
River wash finish Granite stone Flooring Providing material and labour for laying approved quality 18mm thick River wash finish Granite of approved shade in floor, otta, skirting, pavement, plaza or similar in any pattern including average 20 mm thick cement mortar bedding in 1:5 laid and jointed with white cement and matching pigment including rubbing, curing, finishing, cleaning etc complete as directed by EIC. Sample shall be approved before execution. Laying patern shall be as per drawing and instruction of EIC for all floors/ all levels/ all heights and all shapes. (Only finished work will be measured.)
Providing material and labour for fixing 18mm thick mirror polish Granite of uniform size and colour for treads and risers of stair, on coping etc size 1000mm to 2000 mm long, of approved shade, including necessary machine - cut edges, uniform thickness, rounded edges, as per design in required sizes and shapes over 20 mm (average) thick bedding of cement mortar 1:5 (1 cement: 5 coarse sand) laid and jointed with white cement and matching pigment including rubbing, re-polishing after fixing to remove any undulation between the joints (if required) with different grades of Emery, refilling of open joints, curing, daily cleaning and mopping, as directed for at least 15 days or up to the satisfaction of the EIC etc complete for all floors any heights, any lead and lift as per approved sample by Architect, drawings and instruction of EIC. The rate shall be inclusive of making rebates of 10x10mm for forming the grooves between treads and risers with polishing inside the groove. The rate includes machine cut edges of uniform thickness, rounding of edges, champhering and mirror polishing of edges and maintaing upto hand over the project.
Providing material and labour for fixing machine cut, mirror polished 18mm thick best quality Granite stone slab as per approved sample for dado, cladding, skirting, risers of steps etc., in required size and pattern as per drawing, laid on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) or fixed with stone fixing adhesive as per manufacturer's specifications including mirror polishing, champhering, edge polishing, rubbing, curing, finishing, necessary scaffolding, maintaining upto handling over the project etc complete for all floors any heights, any lead and lift etc complete as directed by Engineer Incharge. Backing coat plaster for dado shall be paid in relevant tender item. Rate shall be inclusive of SS 304 grade pin and fastner for fixing the stone with mortar if required and/ suggested by engineer in charge.
Providing material and labour for fixing both side mirror polished 18mm thick best quality Granite stone slab as per sample approved by Architect with rounded edges and mirror polished, of required size fixed as urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) with polymer, as per drawing and as per direction of Engineer-in-charge. All expose edges shall be rounded and mirror polished. Rate shall be inclusive of chasing, cutting, edge rounding/ champhering, edge polishing, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge.
Providing material and labour for fixing mirror polished 18mm thick best quality Granite stone slab as per sample approved by Architect with rounded edges and mirror polished, of required size fixed as platfrom/ vanity counter by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement mortar 1:2 (1 cement : 2 coarse sand) with polymer, as per drawing and as per direction of Engineer-in-charge. 75mm high facia shall be fixed at the edge of platform with epoxy or stone fixing adhesive as per drawing. All expose edges shall be rounded/ champhered and mirror polished. Rate shall be inclusive of chasing, cutting, edge rounding/ champhering, edge polishing, making holes, curing, finishing, maintaining upto handling ovre the project etc complete for all floors all level etc complete as directed by Engineer Incharge. Installed area of platform and facia shall be measured for payment.
Providing material and labour for laying sandwich platform comprising of a) Sandwich of 18 mm thick single side polish Granite of any size, shade and as per approved sample on top and 30 mm thick polished kota in bottom with 25mm thick cement mortar (1:4) in between b) At centre vertical sandwich supports of 30 mm thick two kota stone on sides and 20mm CM (1:4) in between and at both end walls vertical supports of 18 mm thick double side granite. c) 75 mm raised platform at bottom with kota on top and 50mm CM (1:4) at bottom, kota stone skirting as per design and approved sample. The rate includes rounding, champhering and mirror polishing of edges, facias of granite, including necessary bonding adhesive (if required). Rate shall be also inclusive of curing, making holes & cutouts for sink, wash basin, Piller tap/ Bib tap etc, at all floors all height etc complete as directed by Engineer Incharge. (Only plan area shall be measured & paid for). Rate shall be included all kota & granite mentioned in above.
Providing material and labour for roughened strip 2.5 cm wide to form antiskid surface on treads of stairs in any type of stone including forming 2 nos straight deep curved gishi (groove), 6 mm wide & 4 mm deep on two sides of the roughened area, hacking/ hammering/ flaming/ chiseling on surface between two groove, polishing the edges, sides and bottom of gishi etc. complete as per sample approved for all floor, all height. Only one time length of tread of stair shall be measured for payment.
Providing material and labour for laying broken china mosaic flooring, comprising of 20 to 25 mm size broken white/ colour pieces of ceramic/glazed tiles laid over 12 to 15mm thick cement mortar 1:6 (1 cement: 4 coarse sand) bedding including applying cement slurry at the rate of 2.75 kg per sqm on plain or sloped surfaces with joints not exceeding 5 mm, including filling the gaps with white cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6mm, mixing fibre @ 125 grams per 50kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge. The flooring shall be tampered with wooden rammer not exceeding 2 Kg in weight to bring the mortar up to the surface, including rounding of the junctions and extending them upto 15 cm. along the parapet wall. The rate shall include bands, if different colour is used, any pattern or design as per drawing and direction, making vata/ fillet, curing, cleaning with water and oxalic acid, etc. complete. Only Plan area shall be measured for payment.
Providing material and labour for laying Cement Mortar for additional floor bedding in cement mortar 1:5 (1-Cement: 5 - coarse sand) in proper level including curing etc for all floor, all level all height. Additional bedding thickness shall be as per drawing and as directed by engineer in charge.
25mm Kotastone Flooring - Lecture hall Floor with curved Flooring Providing material and labour for laying 25mm thick (average) polished Kota stone slab flooring over 20mm (Average) thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including curing, rubbing and polishing at all floors any heights, any lead and lift in any shape and pattern etc complete as directed by Engineer In charge.
Providing material and labour for laying 40 mm thick mirror polished machine cut kota stone slab of size upto 1.2mt length with uniform thickness for flooring, tread, coping, laid over 20 mm (average) thick base of cement mortar 1:6 (1 cement : 6 coarse sand) and jointed with gray cement slurry/ stone fixing adhesive of approved make including champhering/ rounding in same gauge of exposed edges, polishing, rubbing, curing, finishing, buffing after final polishing, maintaining upto handling ovre the project etc complete as directed by engineer in charge. Each stone shall be fixed with 2 no of anchore fastner of approved make having required length and capacity as directed by Engineer in charge. All Expose edges of stone shall be chmphered with same thickness and polished at all floors any heights, any lead and lift etc complete as directed by Engineer Incharge.
Italian Marble Flooring Providing and laying machine cut, mirror polished, 18mm thick Italian Marble stone of approved make, shade and design in flooring laid in required pattern all complete as per architectural drawings, laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm/ ficed with white stone fixing adhesive of approved make including pointing with white cement slurry admixed with pigment to match the marble shade including finishing, rubbing, curing, polishing, protecting etc. all complete as specified and as directed by the Engineer-in Charge.
Extra for ornamental/ Intricate inlay flooring Extra for Providing & laying ornamental/ Intricate Inlay designer flooring on base of marble/granite flooring with specified inlay pattern with different required shade of marble, sand stone, lime stone, Granite or other specified material per design. Inlay pattern shall be done with CNC cutting machine/ laser cutting/ manual or by any means as per concept image or drawing. Contactor shall prepare shop drawing base on concept drawing or image and get it approved. Contractor shall prepared mock-up as per approved shop drawing and suggested by Architect. Inlay : Providing and laying inlay pattern with specified stone over base stone flooring stone as per approved shop drawing and approved sample. Base stone and inlay marble shall be cut with CNC cutting machine/ hand cutting and making pattern as per approved shop drawing. Inlay shall be fixed with suitable adhesive on existing base flooring. The thickness of inlay material shall be of required thickness of base stone. While applying the adhesive for marble or other stone inlay, color of marble or other stone shall not get varied. After completion of laying of base and inlay, contractor shall finish entire floor (as specified) as per satisfaction of Architect and Engineer in charge. Rate shall be inclusive of inlay material, labor, adhesive, grout, wastage, curing, cleaning with water jet, finishing, etc complete for all floor level and as directed by engineer in charge. Base stone flooring shall be paid in relevant tender item. Flooring area with inlay work shall be measured for payment.
Providing & fixing UV stabilised 2 mm thick flat fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of MS supporting structure etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as approved.
Providing and fixing Brass inlay strip in stone flooring and wall paneling work or similar elements including welding, grinding, buffing, polishing and making curvature (wherever required) and fixing the elements with necessary accessories & Brass/ SS316 dash fasteners, brass bolts etc., of required size with suitable arrangement as per approval of Engineer in charge. Brass shall be heavy and good quality clear satin finish. (for payment purpose only weight of brass members shall be considered of actual installed quantity excluding fixing accessories such as nuts, bolts fasteners etc.)
Grouting the joints of flooring tiles for average size up to 600mm x 600mm having joints of 3 to 5 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade from approved make (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. Sample shall be approved before procurement of material.
Sec.10.0 Structural steel works Providing material and labour for, fabricating, assembling, hoisting/ erecting and fixing in position at all heights/ all levels/ all floors/ all shapes & sizes with all leads & lifts using MS Rolled Steel Sections, Hollow sections, Tubular Sections, MS Plates, Chequered Plates, MS Pipes, Perforated Sheet, Flats, Bars, Angles, MS Sheet, Girder, Beam, cattle trap, deep threaded MS bolts, threaded J bolts, insert plate, support plate etc as per drawing. all confirming to latest relevant IS codes for the work of steel structures like staircases, railings, handrail, jali, gates, grills, bracings, platforms, brackets, monkey ladder, cattle trap, rungs, false ceiling frame work, Roof canopy, fencing posts, M.S. Screen & fencing jali frame work etc. including straightening, cutting, bending, bolting and welding the members all as per approved shop drawings and as per detailed specifications (for materials & workmanship) including necessary scaffolding/ staging etc. complete and comprising of Profile Cutting, Smooth grinding/ machining of edges/ faces/ all welding joints; Necessary welding ; Machine drilling of holes for joining/ anchoring; dry sanding, degreasing (wet cleaning) & preparation of rustfree surface manually or mechanically, metal putty to make the surface even and smooth, 1 coat zinc chromate yellow oxide primer and 2 coat of enamel paint of approved make shade of paint over all the surfaces of the steel sections. The Contractor shall prepare shop drawing as per GFC drawing and as per actual site condition and get approved before execution by engineer in charge. (Standard measurements will be paid for as actual cut length used at site)
Extra over and above on item no - 10.1 for epoxy primer and 2 coats of PU paint of approved make and shade on MS work as per drawing for all floor, all height, all level and as suggested by Engineer in charge.
Modular Railing System Providing and fixing stainless steel (Grade 304) Railing and baluster modular system of approved make stair railing, hand rail, bump rail, guard rail or similar with knock down system in linear or curvilinear shape made of Hollow or solid section i.e. tubes, square, flat, plates, bar etc with base plate, cover cap, finishing accessories, in-filled holding brackets, fixing accessories etc. for any type of design, shape (plain/ curvature), size as per drawing. Railing shall be top mounted or side/ wall mounted. Railing shall be fixed with SS 304 grade anchor fastener of required size and as per fixing position of approved make. Any kind of welding or fabrication shall not be allowed on site. Sample shall be approved before execution. Contractor shall submit the shop drawing base on concept drawing. As per approved shop drawing, contractor shall arrange mock up of railing system (2 or 3 no) in required length as directed by Engineer in charge. Contractor shall protect railing system up till handling over the project. Rate shall be inclusive of fixing accessories and all type fasteners but for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
SS water trough Providing material and labour for, Fabricating and fixing SS 304 grade water trough of size 300mm x 450mm with 300mm high SS sheet cladding (dedo) made out of 1.2mm thick sheet and required size of angle, flat etc in satin/ brush finish including supporting fittings made out of SS 304 grade solid rods, flats, angels, compatible SS anchor fastener (mechanical or chemical) as per manufacturer's specifications, SS supporting arrangement, lath work, argon arc welding bending and bends as per the detail drawing with best (high) quality finish & as per the a sample approved by Architect and as directed by engineer-in-charge. Rate shall be inclusive of all material, labour and wastage for all floor, all height, all level. Water trough shall be measured in Rmt. Installed length shall be measured. Contractor shall prepare shop drawing based on concept drawing ant get approved before execution.
Sec.11.0 Painting works White washing with lime on wall and ceiling surface (two coats) to give an even shade including thoroughly booming the surface to remove all dirt, dust; mortar drops and other foreign matter etc complete for all floors, all heights, all level as directed by Engineer Incharge.
Providing material and labour for applying Distempeing (Two coats) with oil bound washable distemper of approved brand and manufacture and of required shade on wall and ceiling surfaces to give an even shade, over and including a priming coat with alkali resistance primer of approved brand after thoroughly brushing the surface and other foreign matter and also including preparing the surface even and sand parpered smooth etc complete for all floors, all heights, all level as directed by Engineer Incharge.
Providing material and labour for applying (Synthetic) Plastic emulsion paint (minimum 2 coats) having VOC (Volatile Organic Compound) content less than 50 gm/ltr on newly dry interior plastered surface including ceiling, roof etc.at all heights/ all levels/ all surfaces to give an even shade including applying required coats (min two coats) of white cement based putty after thoughly brushing the surfaces free from mortar dropping and other foreign matter. Preparing the surface even and sand papered smooth, after applying every coat of putty complete. Priming coat of alkali resistant cement primer (water or solvent based) is to be applied over prepared smooth surface (undulation free) etc. complete as directed by engineer-in-charge. Sample to be approved before starting of the work by Architect/ EIC. The rate shall include the cost of filler for filling the cracks on surface, thoroughly brushing the surfaces with sand paper to make it free from mortar dropping and other foreign matter, scaffolding etc. as directed by engineer in charge.
Providing material and labour for applying Finishing wall with weather proof exterior emulsion paint on wall surface (two coats) to give an required shape even shade after thoroughly brushing the surface to remove all dirt, and remains of loose powdered materials etc complete for all floors, all heights, all level as directed by Engineer Incharge. (Product with 7 years warranty)
Providing material and labour for applying external finish of average 2 to 2.5mm thick acrylic polymer based texture and pattern with standard tool and applicator as specified by manufacturer on exterior surfaces at all heights including scaffolding to give even shades including thoroughly brushing the surfaces free from mortar droping and other foreign matter and sand paper smoothed as per the manufacture specifications etc. complete for all floor, all height, all level and up to the satisfaction of Engineer in-charge/ Architect. The rate includes making of grooves, pattas and finishing as directed by Engineer in charge. Paint shall be measured and paid in seperate tender item. (Item shall be executed by approved applicator only.)
Sec.12.0 Roofing works Providing material and labour for fixing eco-friendly light weight calcium silicate false ceiling tiles having Tegular edge & 15 mm Thick Densified edges on the Tile Periphery for Extra Strength The Light weight calcium silicate ceiling tiles shall have, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity0.043° w/m KC for the best thermal Insulation. The Light weight calcium Silicate tile shall be of approved texture of size 595 X 595 x 15 mm to be laid on true horizontal level suspended inter locking metal grid of hot dipped galvanized steel sections (galvanizing @120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and size of 24X38mm made from 0.30 mm thick (minimum) sheet, 1200mm centre to centre, and cross ‘T’ of size 24X28mm made out of 0.33mm (Minimum) sheet spaced 1200mm along spaced between main ‘T’ at 600mm centre to centre to form agrid of 1200X600mm and secondary cross ’T’ to be interlocked at middle of the 1200X600mm panel to form grid of size 600X600mm resting on periphery walls/ partitions on a perimeter wall with the help of rawl plugs at 450mm centre to centre with 25mm long dry wall screws @ 230mm interval and laying 15mm thick Densified edges light weight calcium silicate ceiling tiles in the grid including, cutting /making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25X35X1.6mm fixed to ceiling with 12.5mm dia and 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel level clips of size 85X30X0.8mm, spaced at 1200mm centre to centre long main ‘T’ bottom exposed with 24mm of all T-sections shall be pre-painted with polyester baked paint, as per specifications, drawings and as directed by engineer-in-charge. Note:- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm. The calcium silicate ceiling tiles shall have NRC. Value of 0.50 (Minimum) and 0.75 NRC for Globe, light reflection 85% non-combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity. 0.043° w/m KC.for the best thermal Insulation at all floors, any heights, any lead and lift etc complete. as directed by Engineer Incharge.
Providing & Fixing M/F Suspended 12.5mm Plain Gypsum Board which includes GI Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. GI Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the GI soffit clit with Soffit Cleat and Rawl Plug creating 1220mm x 1220mm grid. GI Intermediate channel is fixed to the GI Ceiling Angle with 2 Nos of 4.2x13 GI metal to metal screw. The GI Ceiling Section is then fixed to the GI Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. Single layer of 12.5mm tapered edge Plain Gypsum Board (Confirming to IS 2095-Part-I, 2011) is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing Compound & Joint Paper tape. The contractor shall prepare shop drawings based on the concept drawing and get it approved by the Engineer-in-charge. After approval of drawings, the contractor shall prepare the sample based on the drawing and get it approved by the Engineer-in-Charge before execution. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, making grooves between wall & board or as per drawing for all floor, all level, all height etc as directed by Engineer in charge. Area of cutouts shall not be deducted and no extra payment shall be considered for additional sections provided. Only plan area shall be considered for payment.
Metal False Ceiling: Providing material and labour for, fixing and laying of plain finish GI metal ceiling system consisting of 600 mm x 600mm Clip-in with double pip self-leveling feature and special tabs to allow removal of tile to enable plenum access with plain visual consisting of 600mm x 600 mm clip in tiles of galvanized steel in 0.5 mm thickness with bevel edge in Global white color precoated with primer coat at the rear side with Light Reflectance > 60% and load carrying capacity of 14 KG/ SQM. The T-sections have a galvanizing of 90 grams/sqm and passed through 500 hrs of salt test. Tiles would have fire performance of Class A2-s1.d0 as per EN13501. Installation: To comprise 3000mm long ‘C’ channels spaced at 1200mm centers securely fixed to the structural soffit by support clamp & approved hangers. The last hanger at the end of each C channel shall not be greater than 600mm from the adjacent wall. Use a C-channel connector for splicing two pieces of C-channels. 4000mm Main carriers (spring tee bars) shall be spaced at 600mm centers in a direction perpendicular to the C-channels and shall be secured at every intersection with C channel using a hanger. Use connector to splice two pieces of main carriers. Tiles shall be clipped in between two carriers (spring tee bars) from below. Perimeter trims to be of wall angles of white color secured to walls at 450mm maximum centers. Cut tiles to be secured to the wall angles using a spring clamp. Tile, grid system and suspention system shall be of same make and as per approved sample. The Tile & Grid system used together shall carry a 10 year warrantee. Installation will be done by approved installer only. The shop drawing, specification and sample mock of miniumum 5 Sqmt with framework shall be approved by Architect/ EIC. Rate shall also include cost of making of all cutouts for light fixtures, gadgets, gizmo, pelmets, grooves, beads and also provide support/ template where ever required. The rate shall be in Sqmt for all floors/ all heights/ all levels including scaffolding etc. as directed by Engioneer in charge.
Perforated Gypsum tile acoustic false ceiling : Supplying material labour for fixing of Suspended ceiling system with 12.5mm thick glass fibre perforated gypsum plaster board/ tile of any size having any type of edges and any shape, any size, any pattern perforation and GI suspended framing system. This includes ribbed frame Perimeter Channel fixed to brick wall/partition with the help of nylon sleeves and screws at 600mm centres along the perimeter of ceiling. Then suspending ribbed section used as intermediate channel from the soffit at 1220mm centres with Ceiling Angle fixed to RCC Slab with Soffit Cleat and steel expansion Fasteners @ 600mm Centres respectively. Ultra frame ribbed Ceiling Section are then fixed to Intermediate channel with the help of four point connecting clip (0.8mm thick) and in perpendicular direction to the intermediate channel at 600mm centres. 12.5mm thick glass fibre perforated gypsum plasterboards/ tile of any size having any shape, any size, any pattern perforation with acoustical tissue backing is screw fixed with 25mm long Drywall screws at 230 mm centres. The screw fixing of gypsum plasterboards to the metal framing at the periphery, openings and cut edges shall be at 150mm centres. Finally square or tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound, Joint Paper tape and two coats of Drywall Top Coat as per the drawing & approved sample. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights/ air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/ cutouts, scafolding, making grooves between wall & board or as per drawing etc complete for all level, all height, all floor amd as directed by Engineer in charge. Only plan area shall be considered for payment.
Providing and fixing ready made Access panel/ trap door (recess type) made from minimum 1 mm thick galvanised steel. Doors shall be finished in Powder Coating with approx 60 microns DFT, in desired RAL Shades as approved by Architect. The manufacturer company must be ISO 9001-2015 certified. Same ceiling board shall be fixed in recess part (depth equal to thikness of board) of trap door. Door shall be with concealed type of hinges, locking system, safet chain and appropriate provision for hanging from celling.
Providing and fixing ready made Access panel/ trap door of size 600mm x 600mm made out of powder coated aluminium of approved make as per drawing including aluminium outer and inner frame, door, push latch, safety cable, removable hinge, intermediate and perimeter channel etc for all floor, all height etc complete as directed by engineer in charge. Contractor shall submit the technical data sheet of product regarding loading capacity to engineer in charge. Loose and fixed sample of access panel shall be approved by engineer in charge. Cost shall be inclusive of false ceiling board as per surrounding ceiling and its finishing.
Providing and fixing ready made Access panel/ trap door of size 600mm x 1200mm made out of powder coated aluminium of approved make as per drawing including aluminium outer and inner frame, door, push latch, safety cable, removable hinge, intermediate and perimeter channel etc for all floor, all height etc complete as directed by engineer in charge. Contractor shall submit the technical data sheet of product regarding loading capacity to engineer in charge. Loose and fixed sample of access panel shall be approved by engineer in charge. Cost shall be inclusive of false ceiling board as per surrounding ceiling and its finishing.
Fiber cement board : Providing material and labour for fixing exterior grade cement fibre board/ plank cement pattas of 8 mm thickness at exposed concrete ceiling/ wall/ beam bottom with brass/ SS head screws as per drawings, specification and sample approved at all floors, all levels and all shapes etc complete as directed by engineer in charge. Rate shall be inclusive of all material, labour, scafolding, tools, tackes etc complete.
Mineral wool insulation Providing material and labour for installing 50mm thick 48kg/cum density mineral wool (pre-wrapped) in the wall panelling and over acoustic false ceiling as per required application, for all floor, all height, all level as per drawing and as directed by engineer in charge.
Plywood +laminates Acoustic False ceiling Providing material and labour for fixing 12 mm thick water resistant ply confirming IS 303 BWR of approved make for false ceiling, which includes GI framing like GypSerra of Saint Gobain or equivalent. 1.0mm thick laminates of approved make and shade shall be paste on external side of 12mm thick ply with adhesive of approved make. Exposed edges of ply shall be covered with 12mm thick 1st class teak wood bedding in total depth. Bedding patti shall be finished with Lacquer polish of approved make and shade. Contractor shall cut perforations/ round holes of various sizes in uniform/ rendom pattern on ply and laminates panel as per the drawing and approved by EIC/ Architect. The holes shall be CNC cut in computer. Framing includes Perimeter Channel is fixed along the perimeter of existing wall/ partition with the help of screws at 600mm centres. Ceiling Angle is suspended at up to suitable height as per sight conditions by fixing it to the soffit clit with Soffit Cleat and Rawl Plug creating 1220mm x 1220mm grid. Intermediate channel is fixed to the Ceiling Angle with 2 Nos of 4.2x13 metal to metal screw. The Ceiling Section is then fixed to the Intermediate Channel with the help of Connecting Clip and in direction perpendicular to the Intermediate channel at 457mm c/c. Suggested/ Mentioned board/ ply is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. All members of ceiling system i.e perimeter channel, angle, soffiet cleat, intermediate channel, connecting clip etc is GI (IS513) having YS-300Mpa, Finish-Galvanised 150GSM (IS 277). Knurled steel section has effective thickness of 2T (2 x depth). Only plan area shall be measured and paid without considering any wastage. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/cut-outs, making grooves between wall & board etc complete for all floor, all level, all height. Area of cut-outs shall not be deducted and no extra payment shall be considered for additional sections provided. Contractor shall prepare shop drawing based on concept drawing and get approved by engineer in charge. Sample of all loose material shall be approved. Contractor shall prepare mock-up (minimum 2.0 Sqm) with complete finish and get approved by engineer in charge. Necessary MS structure for frame and hanging system shall be paid in relevant items.
Plywood + laminates Acoustic wall panelling with GI framing : Providing material and labour for fixing 12 mm thick water resistant ply confirming IS 303 BWR of approved make for wall panelling, which includes GI framing like GI CLOSED STUD partition of approved make. 1.0mm thick laminates of approved make and shade shall be paste on external side of 12mm thick ply with adhesive of approved make. Exposed edges of ply shall be covered with 12mm thick teak wood bedding with total depth. Bedding patti shall be finished with lacqure polish of approved make and shade. Contractor shall cut perforations/ round holes of various sizes in uniform/ rendom pattern on ply and laminates panel as per the drawing and approved by EIC/ Architect. The holes shall be CNC cut in computer. Framing - 48x0.6mm CLOSED STUD shall be placed at 600mm c/c in 50x0.5mm floor channel. Floor channel shall be cut & bend and braced with Wall and closed stud at every 900mm c/c vertically. Floor channel is anchored to the floor & True ceiling using Rawl plug of Ø8x45mm (Material-IS 513 CR1 grade, Zinc coating, Pull Out Load-7.5kN for M20 concrete grade) with suitable anchor fasteners at 600mm c/c in centerline manner. GI noggin channel of 48x0.5mm width has to be provided at the horizontal joints of the two boards. End of paneling shall be closed with same thickness of ply. Only elevation area shall be measured and paid without considering any wastage. Rates shall be inclusive of cost of making cut outs/ openings for electrical fixtures, tube lights /air-conditioners, grills, diffusers etc & providing additional sections for strengthening the openings/cut-outs, making grooves between wall & board etc complete for all floor, all level, all height. Area of cut-outs shall not be deducted and no extra payment shall be considered for additional sections provided. Contractor shall prepare shop drawing based on concept drawing and get approved by engineer in charge. Sample of all loose material shall be approved. Contractor shall prepare mock-up (minimum 2.0 Sqm) with complete finish and get approved by engineer in charge. Necessary MS structure for frame and hanging system/ service elements shall be paid in relevant items.
Fabric wall panelling Providing material and labour for fixing 13.5 mm thick 'Silance' Acoustic and Sound Absorption Panel System, size 2700mm x 1200mm & weighing 6.45 kg per sheet, manufactured from 100% polyester fibers/ poly propylene / polyethylene terephthalate panel. Fibers Needle punched and thermally bonded in a non – woven matrix semi rigid specifically tooled and pressed for maximum sound absorption, with an 70% NRC (0.70 NRC). 'Silance' Acoustic and Sound Absorption Panel System is to be fixed on 24" (600mm) gap framework, of chemically treated wood (CCA treatment) of 40 mm x 25mm wooden patti, which shall be fixed into wall and which shall create true line and level with screws, fixed horizontally or vertically (as per architectural design). 'Silance' Acoustic and Sound Absorption Panel ('Silance' Acoustic and Sound Absorption Panel System panels can also be fitted as the same way as above using Gypserra GI frame or 'Silance' Acoustic and Sound Absorption Panel System can also be installed with suitable adhesive directly on the wall. Fabric shall be covered with Fabric of approved make and shade as per the drawing in pattern of specified size. Rate shall be inclusive of fabric, Lipping, labour, necessary hardwares, adhesives required, etc. Wooden Beading shall be applied on all the sides of the panels of required size. Lacquer Polish shall be applied on expose wooden lipping etc. The rates shall be inclusive of laquer polishing, all wastages, fabric, labor for applying fabric, taxes, transportation, loading, unloading, fixing in position for all heights, scafolding etc. Complete and as directed by Engineer-in-charge. Only elevation area of fabric shall be measured and paid in Sqm. Wastage shall not be considered. Contractor shall get the sample approved by Architect/ Engineer-in-charges.
Providing material and labour for fixing of 12 mm thick approved quality soft board of approved make with cotton cloth/fabric of approved make and shade on 12mm thick BWR 300 grade ply with 1st class teak wood beading all around including lacquer polish, as approved sample and as directed by Architect. Elevation area of the soft board including lipping shall be measured and paid. The rates shall be inclusive of all wastages, laquer polishing, fabric, labor for applying fabric, for all level, all heights etc. complete as directed by Engineer-in-charge. Wastage shall not be considered. Contractor shall get the sample and approved by Architect/ Engineer-in-charges.
Providing material and labour for fixing precoated galvalume iron profile sheets (size, shape, shade and pitch of corrugation as approved by Engineer-in-charge). Profile sheet of nominal1015 mm effective cover width and nominal 28.5 mm deep ribs with subtle square fluting in the five pan at nominal 203 mm centre-to-centre. The end rib shall be designed for anti-capillary action, to avoid any seepage of water through the lateral overlap. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), 0.50mm Total thickness, Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per AS 1397 /IS 15961- Zincalume AZ150 (Min.150 gms/Sqmt total on both sides) with superior quality paint coat. The paint shall have a total coating thickness of nominal 35 μm, comprising of nominal 20 μm exterior coat on top surface and nominal 5 μm reverse coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade. The sheet shall be fixed using Self Drilling, Self Tapping bolts of approved make of required size (and all necessary overlaps complying to the manufacturer's specifications including cutting to size and shape, erecting at all levels, all height, providing openings, all fixtures and fixing, accessories with EPDM sealing, silicon sealant at ridge and valleys including all material, labour, scaffolding, wastage, tools, tackles, equipment, transportation, shop drawing, and excluding the cost of purlins and rafters etc all complete as per drawings as directed by the engineer in charge . The rate shall include end laps, side laps, bolts etc. Sheets shall be supplied in custom lengths upto 12.0 m. All overlaps shall be sealed with silicone sealants for sloped roofings. Actual plan area of roof shall be measured for payment with out considering wastage and overlap.
Sec.15.0 General Development and Road works Box cutting the road surface to proper slope and camber for making a base for road work including removing the excavated stuff and depositing on the road side slope as directed upto 1 Km lead and all lift.
Providing and laying rubble soling in plinth and sub-base of road, compacted thickness specified as following, using specified size of hard stones for average 150mm thick soling, filling, covering and leveling the surface with a layer of earth after filling the voids (upto 25%) with sand, smaller sized black trap stones 20-40mm, 40-63mm, 63-90, 90-150mm size of stone/metals or stone chips, including watering, ramming well and compacting or consolidating each layer by static roller/ vibratory roller of required capacity as directed by Engineer-in charge.
Construction of Granular Sub Base (GSB) by providing coarse graded material of any grade, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, including all material, labour, machinery with all leads and lifts etc. complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for, laying, spreading and compacting graded stone aggregate to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in mechanical mix plant carriage of mixed material by tripper to site, laying in uniform layers with paver in sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density including all material, labour, machinery with all leads and lifts etc complete as per MORTH specification and as directed by Engineer in charge.
Providing material and labour for laying precast fair finish curbing of (factory made and vacume pressed) RCC M25 grade curbing 300mm height x 125mm thick including necessary excavation, cutting the road, laying PCC 1:4:8 (1 cement: 4 sand: 8 stone aggregate 20/37 mm. down size), shuttering, exposed rendering, curing, flush pointing CM 1:3 excluding reinforcement as per the drawing, as per approved sample and as directed by Engineer in charge.
Providing material and labour for laying precast fair finish curbing of (factory made and vacume pressed) RCC M25 grade curbing 450mm height x 125mm thick including necessary excavation, cutting the road, laying PCC 1:4:8 (1 cement: 4 sand: 8 stone aggregate 20/37 mm. down size), shuttering, exposed rendering, curing, flush pointing CM 1:3 excluding reinforcement as per the drawing, as per approved sample and as directed by Engineer in charge.
Providing material and labour for laying 60mm thick Solid Concrete Combination Cobbles of differant size, made by vibro pressed method of VYARA or equivalent as approved by Architect/ EIC, with +/-3mm tolerance and thickness of wearing layer not less than 5mm of any color and shade (UV Light resistant fast colours from Lanxess only to be used) having compressive strength of 30 Kg/cm2 for footpath, parking areas, service lanes and other areas as mentioned in the drawing. Combination cobbles shall be laid as per approved pattern and suggested by manufacturer and Architect. Including providing and laying average 50 mm thick average bedding layer of coarse sand below the block as per required grading and specification.Laid paver block shall be mechanically compacted and as directed by Engineer in charge. The work shall be executed in line and level by skilled mason of flooring work only for paver blocks. The Finished surface of the paver block shall have coarse sand texture finish. Sample to be approved before starting of the work by Architect/ EIC.
Providing material and labour for fixing Ductile iron manhole frame and cover/ grating/ chamber cover of approved make and type. Man hole cover shall be any type (hinged type, double sealed or recess type), any shape (square/ rectangle/ square frame with round cover) any grade (light duty/ medium duty/ heavy duty) of required loading capacity having double sealed system as per manufacturing standard BS EN-124, with proper lifting arrangement, black bituminous coating, including fixing in CC and finishing etc complete as directed by engineer in charge. Cover shall be as per drawing and as per approved sample. Recess manhole cover depth shall be according to pavement/ finish as per drawing.
Providing material and labour for fixing in position 80 mm thick factory made machine batched & machine mixed Solid Precast RCC Rectangular Covers on cable trench of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe 500 grade @ maximum 100mm c/c on both ways , neat cement punning on finished surface, properly encased on all edges with 1.6 mm thick , 100 mm wide MS sheet duly painted over priming coat , reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc i/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge.
Sec - 16 Signage Work Providing material and labour for fixing SS 304 grade brush finish 1.2mm thick Internal signage of any shape any size with letter, numbers, graphic, symbol etc made by etching with duco paint frilling/ laser print or vinyle sticker with lamination of approved make and shade. All signage plates shall be made in CNC water jet cutting, with all smoothen edges and cute round corner. Signage matter shall be as per drawing. The plate shall be fixed on brick masonry or RCC wall/ door shutter or any other flat surface with the necessary fixing like stud, fastner, self adhesive tapr or sealant/ adhesive etc complete for all floor all height as directed by Engineer in charge.
Providing material and labour for, making and fixing 4 mm thick ACP sign of any shape and size of Flexi bond or equivalent to be cut on CNC router cutting and smoothen all corners and edges. Matter shall be cut in 3M Reflective vinyl and paste on it as per design and detail and as per manufacturer's specifications. UV stabilized lamination shall be paste on it. The ACP sheet shall be fixed with clamp on MS Pole/ fixed or mount on wall/ hung from ceiling with required fastning hardware. Content of sign shall be letters (In Gujarati & English), graphics/ maps, signs etc in any colour as per design, drawing and approved by Architect and Engineer in charge. Cost of MS Structure and Civil works shall be paid as per relevant tender items. The rate shall also include cost of scaffolding, drilling, fabrication, finishing, adhesive material etc at all height and all level as directed by Engineer in charge. The contractor shall submit the shop drawings based on concept design and do the sampling and get it approval before mass production.
2.0 PLUMBING WORKS PHE-01.00 Water Supply Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design: 18.33.1 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Supplying, & erecting C.I. swing, check type non-return (Reflux) Valve -ISI marked suitable for following size (B) 65 mm dia.
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. B) 50mm dia.
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. C) 65mm dia.
Providing, fixing, testing and commissioning C.I. body, Motorised Butterfly valve (PN10 rating) with quarter turn, on/off electric actuator, SG Iron disc with EPDM/Nitrile seat, wafer type,with panel, IP-67 water tight alluminium enclosure with postion indicator working on operated by float type level controller and manually, VOLTAGE 220V AC. D) 80mm dia.
Providing & fixing on line Electro-magnetic flow meter with preamplifier & microprocessor based electronic flow meter mounted adjacent to flow sensor with Modbus data output to the BMS Rack located in the Plumbing Plant Room. Device to monitor the Total Flow, Flow rate / velocity, etc. Including wiring from sensor to transmitter. Complete with all type of Plumbing & Electrical connections, accessories, wiring, & supports complete with all respect. The signal from read out shall be 4-20 m.amps to be received on BAS. The complete installation would be as per the approval and direction of the Engineer-in-charge. Electronic Flow Sensor & Transmitter – Media Clear Liquids; Line Size - as mentioned below; Display - 8 Digit for Flow Rate & 8 Digit for Flow Totalized – 16 x 2 Backlit Alphanumeric LCD; MOC: Body – SS with PU Coating; Flange: SS 316; Flow Tube: SS 304; Liner: Hard Rubber; Electrical Wire of 3 core x 1.5 Sq. mm of approved make with 6 amp 3 pin plug, Protection Class: IP 68; Earthing as per manufacturers' standards; Accuracy: 0.5%; complete. (B) 65mm diameter
Providing and laying in trenches galvanised Mild Steel tubes (medium grade) of the following nominal bore, and tube fitting (Earthwork in trenches to be measured and paid for separately) (E) 65mm
Excavation for foundation (executed with manual labour) upto 1.5 m depth including sorting out and stacking of useful materials and disposing off the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Supplying & erecting approved make Automatic liquid level controller 6A.as per instruction of Engineer in charge on site complete with wiring connection with existing wires , with copper conductor from pump to upper and lower tank.
Providing and fixing ball cock of approved. quality as directed.(B) Abonite (ii) 50mm dia.
Providing and fixing C.I. Manhole cover 0.60 M. x 0.45M. size having weight not less than 35Kg.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [A] 15 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [B] 20 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [C] 25 mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [D] 32mm.
Providing and fixing concealed center point to wall ceiling & floor CPVC (SDR 13.5) PIPE having National Sanitation Foundation (NSF) seal for potable water of following dia. nominal bore tube fittings and clamps including making good the wall, ceiling and floor etc. complete. [E] 40mm.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch 40) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of trenching and refilling, complete as per direction of Engineer in Charge. Buried work in sunk slab area. 65 mm nominal dia Pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (i) 15 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (ii) 20 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (iii) 25 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (iv) 32 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (v) 40 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (vi) 50 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. Internal Exposed Works (vii) 65 mm nominal outer dia pipes
Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) (Sch-40) Pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-In-Charge. (viii) 80 mm nominal outer dia pipes
Providing and fixing Gun metal check or non-return fullway wheel valve.(A) 15mm dia.
Providing and fixing Gun metal check or non-return fullway wheel valve.(B) 20mm dia.
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (f) 65mm dia nominal bore.
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. a) 15 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. b) 20 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. c) 25 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. d) 32 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. e) 40 mm nominal bore
Providing and fixing long handle unplasticized polyvinyl chloride (UPVC) Ball valves with S.S. 304 ball valve, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. f) 50 mm nominal bore
Providing and fixing PVC Ball valves with S.S. 304 ball valve on EPDM seat, having pressure bearing capacity up to 7.0 kg/cm² at 82°C, of the following sizes including cutting the pipes, solvent welding, complete as per the manufacturers standards and the direction of the Engineer-in-charge. Make: Astral / Ashirvad / Equivalent. g) 65 mm nominal bore
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (e) 50mm dia nominal bore.
Providing and fixing Gun metal gate valve with C.I. wheel of approved quality (screwed end). (f) 65mm dia nominal bore.
Providing, fixing, jointing, testing and commissioning of Pressure Reducing Valve Set for cold water supply comprising of 2 Nos Gun Metal ball valves on inlet & outlet & 01 no. Globe valve for by-pass, 01 No. Brass housing diaphragm operated Pressure Reducing Valve with flanged / screwed connection, with in-built SS 316 Filter with filter opening size 0.8 mm or lower, 1 Nos Pressure gauge on outlet, and 1 No. 15 mm dia safety valve. The complete system is tested to a pressure not less than 10 Kg/Sq.cm Including necessary pipe & fittings; i.e. flanges/ unions, nuts, bolts and washers complete as required. (installed on cold water make up line to Hot water mixing tank) with all necessary accessories, as per specification/drawings and as directed by Engineer In Charge. Note: The PRV shall be installed in an accessible location. Inlet Pressure: Max. 10 Kg/Sq.cm; Outlet Pressure: 1.5 Kg/Sq.cm; a) 25 mm dia (Brass Housing - PRV)
Providing, fixing, jointing, testing and commissioning of Pressure Reducing Valve Set for cold water supply comprising of 2 Nos Gun Metal ball valves on inlet & outlet & 01 no. Globe valve for by-pass, 01 No. Brass housing diaphragm operated Pressure Reducing Valve with flanged / screwed connection, with in-built SS 316 Filter with filter opening size 0.8 mm or lower, 1 Nos Pressure gauge on outlet, and 1 No. 15 mm dia safety valve. The complete system is tested to a pressure not less than 10 Kg/Sq.cm Including necessary pipe & fittings; i.e. flanges/ unions, nuts, bolts and washers complete as required. (installed on cold water make up line to Hot water mixing tank) with all necessary accessories, as per specification/drawings and as directed by Engineer In Charge. Note: The PRV shall be installed in an accessible location. Inlet Pressure: Max. 10 Kg/Sq.cm; Outlet Pressure: 1.5 Kg/Sq.cm; b) 32 mm dia (Brass Housing - PRV)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance ) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (a) 15 mm dia (09mm thickness of insulation)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (b) 20 mm dia (09mm thickness of insulation)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (c) 25 mm dia (13mm thickness of insulation)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (d) 32 mm dia (13mm thickness of insulation)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (e) 40 mm dia (13mm thickness of insulation)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (f) 50 mm dia (13mm thickness of insulation)
Providing, fixing, jointing, testing and commissioning of of Nitrile rubber closed cell (Thermo plastic elastomeric) insulation (insulation shall be as per class 'O' IMO fire performance) of the following diameter and thickness over pipes and fittings, of minimum 45 kg / M³ density and haivng thermal conductivity 0.037W/MK or better at 20°C mean temperature, class 'O' insulation applied by suitable adhesive complete as per manufacturers specifications (for internal and external pipes) including 22 SWG GI sheet cladding over nitrile rubber insulation on hot water pipe work with necessary accessories as per specifications/drawings all complete as per directions of the Engineer In charge. Rate includes cost of all materials including fixing the insulation with the pipes with tapes or adhesives, labour charges for working at all levels. leads and heights. For Hot & Refrigerated Water. (g) 65 mm dia (13mm thickness of insulation)
PHE-02.00 Sanitary Installations: Providing and Fixing vitreous china extended wall mount water closet (EWC) as per IS: 2556 (Part 2) of size 610 x 370 x 320mm (P Type) including seat and cover as per IS: 2548 of approved make and quality, and as approved by Engineer-in-charge, including all necessary fittings and accessories, complete. (I) Type 1 - Hindware - Twilight - Model # 92092 / Equivalent
Providing & fixing Divyang toilet set with European Closet (P Trap) & wall mount wash basin & all divyang requirements with dual flush tank, seat & lead (heavy duty) including C.I. Brackets, C.P. brass hinges, M.S. / C.I. painted brackets, 32mm CP waste Coupling, 32mm size CP bottle trap, CP brass Spatula Faucet, etc. all Internal fittings complete with S.S grab rails etc. rubber buffers, C.P nuts, bolts etc making holes in walls & floors, & finishing for ready to use.The rate includes all necessary connection charges as per product detail to the satisfaction and as directed by the Engineer-in-charge. Make: Hindware - Matrix - 70002 Set of WC, Wash Basin, Grab Bars; Make: Jaquar - Spatula Faucet - FLR-5093N; Make: WaterTech / Prayag - PTMT wastecoupling & bottle trap. Divyang Set: Make - Hindware - Matrix Set - 70002; Long Handle Basin Cock: Make: Jaquar - Florentine - FLR-5031 N / Equivalent.
PHE-02.00 Sanitary Installations:Providing and Fixing vitreous china extended wall mount water closet (EWC) as per IS: 2556 (Part 2) of size 610 x 370 x 320mm (P Type) including seat and cover as per IS: 2548 of approved make and quality, and as approved by Engineer-in-charge, including all necessary fittings and accessories, complete. (I) Type 1 - Hindware - Twilight - Model # 92092 / Equivalent
Providing and fixing white vitreous China overcounter washbasin with single hole for pillar tap fitted over the counter with required and appropriate silicon sealant and making good the same, including pillar tap, braided hose, 32mm waste coupling, 32mm CP brass bottle trap, complete as per the direction and approval of the Engineer in charge. Size: 380 mm x 380mm x 130mm depth. Wash Basin - Make: Hindware - Inox - #91066; Pillar Cock with neck aerator - Make: Cera - F3002103; Waste Couling - Make: Cera - F8050301; Bottle Trap - Make: Cera - F8060301
Providing and fixing Flat Back Urinal with back inlet water supply of approved make and quality including conecting the Urinal with waste pipe, including fixing to wall with C.P. brass screws, rawl plugs, etc. complete. Make: Hindware - Flat Back Urinal of size 300 x 330 x 450mm - Corto - 60022 / Equivalent.
Providing & fixing C.P. brass Concealed type flush valve (Metropole Flush Valve) with, 25 mm dia C.P. flush pipe with clamp and adapter, rubber joint, C.P. brass wall flange, elbow complete with all other accessories. Make: Jaquar - FLV-1085N or Equivalent
Providing and Fixing in position CP brass Pressmatic auto closing concealed Urinal Flush Valve Auto-closing system with wall flange of approved or equivalent make, including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. Make: Auot Closing Pressmatic Urinal Flush Valve: Jaquar - PRS - 073 / Equivalent.
Providing and fixing ABS Chrome plated Brass Hand Shower (Health Faucet) of approved make and quality and as approved by Engineer - In - Charge, including 8 mm dia, 1 Meter long Flexible tube & wall hook including cutting and making good the walls wherever required complete as per directions of the Engineer-in-charge. Make: Jaquar - ALD-573GA or Equivalent of the same make.
Providing and fixing C.P. brass Side single lever sink mixer with swinging spout (table mounted) with 450mm long braided hoses, of approved make and quality, and as approved by the Engineer-in-charge, and conforming to Manufacturers Standards. Make: Jaquar - Florentine - FLR-5179B / Equivalent.
Providing and fixing C.P. brass waste for washbasin or sink. (A) 32mmdia.
Providing and fixing C.P. brass waste for washbasin or sink. (B) 40mm dia.
Providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin.
Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet.(A) 100mm dia. Each
Providing and fixing C.P. brass Shower arm for over head shower of approved make and quality, and as approved by the Engineer-in-charge, and conforming to Manufacturers Standards. a) Size: Casted 190mm long light body round shape for wall mounted shower rose with flange, of approved make and as per the direction of the Engineer-in-charge. Make: Jaquar - SHA - 483 / Equivalent.
Providing and fixing C.P. brass Wall Mixer with provision for overhead shower with 115mm Long Bend pipe on upper side, connecting legs & wall flanges, complete as per approved make and as directed by the Engineer-in-charge. Make: Jaquar - Fusion - FUS 29147 / Equivalent.
Providing and fixing C.P. brass towel rail complete with C.P. brass brackets fixed to wooden plugs with C.P. brass scews.(B) 600mm x 20mm size.
Providing and fixing toilet paper holder.(A) C.P. Brass
Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia.
Providing and fixing of 15mm nominal bore CP Brass Angle valve confirming to IS: 8931, for wash basins, water coolers, geyser points, etc of approved quality and as approved by and directed by the Engineer-in-charge.
Providing and Fixing 15 mm dia. CP brass two way bib cock with wall flange and ceramic disc cartridge complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. Make: Jaquar-FLR-5041NG or Equivalent of the same make.
Providing and Fixing 15 mm dia. CP brass extended lever handle pillar cock with ceramic disc cartridge for all laboratory sinks or as directed by the Engineer-in-charge, complete, making all necessary connections etc of approved make. Make: Jaquar-Florentine - FLR-5031 N / Equivalent.
Providing and Fixing 15 mm dia. Wall mounted type CP brass pressmatic bib cock with Auto Closing System with Built-in Control Cock With Wall Flange complete, making all necessary connections etc. All complete as per directions of the Engineer-in-charge. i) 15mm dia. Make: Jaquar-PRS-043 / Equivalent.
Providing and fixing 15 mm diameter Extended Body Pillar Cock with lift tye operating knob & base flange of approved make and quality and as approved by Engineer-in-charge, including 600 mm long braided hose with M10X1 Nipple, 15mm nut, O-ring & rubber washer, including cutting and making good the counters wherever required complete as per directions of the Engineer-in-charge. Make: Jaquar - Pillar Cock - Vignette Prime - VGP 81021N; Braided Hose Pipe - ALD-801B / Equivalent.
Providing and Fixing SS Liquid Soap Dispenser of approved make and quality, and as approved by the Engineer-in-charge, including all necessary materials required for fixing. All complete as per directions of the Engineer-in-charge. Make; Jaquar - ACN-1137N / Equivalent
Providing, fixing, jointing, testing and commissioning of Heavy class SS grating of grade SS 304 of approved make and quality, and as approved by the Engineer, weighing not less than 150 gms. including setting in floor with white cement to match with floor finish as per requirement complete as per directions of Engineer in charge. Type 1 - Size 129mm x 129mm Square Matt finish with Cockroach trap consisting of 104mm diameter (101mm) perforated top cover, 77mm Ø x 70mm high Cockroach Trap ideal for 100mm drain pipe with floor trap cover as specified in approved make and quality. Make: Chilly - Square Gypsy: Model No: CCT-SG-129 / Equivalent.
Providing, fixing, jointing, testing and commissioning of Heavy class SS grating of grade SS 304 of approved make and quality, and as approved by the Engineer, weighing not less than 150 gms. including setting in floor with white cement to match with floor finish as per requirement complete as per directions of Engineer in charge. Type 2 - Size 150mm x 150mm Square Matt finish with Cockroach trap consisting of 100mm diameter solid top cover, 77mm Ø x 70mm high Cockroach Trap ideal for 100mm drain pipe with floor trap cover as specified in approved make and quality. (For Urinal only) Make: Chilly - Lifestyle Square : Model No: CCTL-S-150 / Equivalent.
Providing and fixing Structured Wall U.P.V.C. non pressurized wastewater piping conforming to IS: 13592, and fittings as per IS: 14735, including all fittings like bends, tees, reducers, Y joints, couplers, etc with rubber inserts of 3mm thickness complete, joined by manufacturer's recommended rubber lubricant, including cutting the pipes to required lenghts, including fixing the pipes with MS Split clamps with EPDM rubber lining of required diameter at 1.20 M spacing center to center, GI threaded rods, anchor fasteners, drilling of holes in ceiling slabs and walls as required, and installations at all levels and heights, as directed by the Engineer-in-Charge. Make: Ashirvad / Astral / Huliot / Equivalent. f) 200mm dia pipe
Providing and fixing of self cleansing P Trap, in Structured Wall UPVC non pressurized wastewater piping as per IS: 14735, of size 110mm x110mm with solvent cement welding, complete, including cost of cutting and making good the walls and floors. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 160mm diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing, laying and jointing in true line and level 110mm diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
Providing, laying and jointing in true line and level 90 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed & fittings conforming to ISI 14735-1999 of approved make for HVAC drainage system pipe line, pipe shall be jointed with each other with solvent cement, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls / floors as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 75 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 50 diametre P.V.C (6kg/cm2) conforming to IS 4985 with single socket, & fittings of approved make for drainage system pipe line, pipe shall be jointed with each other with appropriate solvent cement, pipe shall be shall be concealed in walls as directed, including necessary fittings such as bends, shoes etc. including testing of pipes and joints, including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 40 diametre PVC (6kg/cm2) conforming to IS 4985 with single socket, & fittings of approved make for drainage system pipe line, pipe shall be jointed with appropriate solvent cement, pipe shall be shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints, including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 75 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 110 mm Dia pipe. Make: Astral / Ashirvad / Prince.
Providing and fixing unplasticized PVC SWR as per IS: 13592 (Type B), vent cowl as approved and directed by the Engineer-in-charge. For 150 mm Dia pipe. Make: Astral / Ashirvad / Prince.
Providing, laying and jointing in true line and level 150 diametre U.P.V.C (Type A) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with each other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials. Make: Astral / Ashirvad / Prince.
Providing and fixing on wall face unplasticized-PVC rain water pipes conforming to IS : 13592 (Type A) including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion. (i) Single Socketed Pipes (110mm dia pipes)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised-PVC rain water pipes conforming to IS : 13592 (Type A), including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe Bend - 110mm dia pipe
Providing and fixing G.I. Rain water spout of 50mm dia. and 30cm. length.
PHE 03.00 Drainage: Providing laying (to level or slopes) and jointing reinforced concrete Light duty non-pressure pipes I.S. class NP2 of the following internal diameter with collars and butt ends prepared for collar joints including testing of joints complete.(C) 250mm (upto 10 ton)
Providing and erecting at the site of work steel ventilating column of 150m internal diameter and 12.20 Metre High from G.L. to bottom of top grill including C.I. grill and base plate bolts and nuts etc. and excavation in foundation of size 120cm. x 120vcm. x 165cm. and filling the pit with first layer of cement concrete 1:3:6 mix (1-cement :3-coarse sand :6-graded stone aggregate 20mm nominal size) of 120cm. x 120cm. x 90cm. and remaining pit with B.B.C. 1:3:6 mix (1-cement :3-coarse sand:6-Brickbats 40+50mm size) and providing fillet in Cement concrete 1:2:4 mix (1-cement :2- coarse sand :4-graded stone aggregate 20mm. nominal size) at G.L. and 3 coats of silver paint etc. complete. (upto 10 ton)
Constructing brick masonary chamber for under ground C.I. Inspection Chamber and bends with bricks having crushing stregth no less then 35 kg/cm2 in C.M 1 :5 having C.I. cover with frame (light duty) of size 455 mm x 610 mm internal dimension total weight of cover with frame to be not less than 38 kg (Wt. of cover 28 kg, Wt. of frame 15 kg), R.C.C. top slab with 1: 2 : 4 mix (1 Cement : 2 coarese sand : 4 grade stone aggregate 20 mm size) foundation concrete 1:5:10 inside plaster 15 mm thick with cement mortar 1 : 3 finished smooth with a floating coat of neat cement on walls and bed concerete etc. complete. (iii) Inside dimension 600 mm x 850 mm and 450 mm deep for pipe line with three or more inlets.
Constrcting Manhole with R.C.C. top slab in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 Brick bats 40 to 50 mm. size) inside plastering 15mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) finished smooth complete including curing and testing. (i) Inside size 900mm x 1200 mm and 1.50 meter deep including heavy duty FRC Manhole frame and cover of size - 560 diameter total weight of cover and frame to be not less than 128 kgs (Wt. of cover 64 kg and Wt. of frame 64 kg) (A) with 230 mm thick walls of brick masonary using bricks having crushing strength not less then 35 kg/sq.cm in cement motar 1 : 5 (1 cement : 5 coarse sand) (1) A type depth 0.9 metre for 150 mm diameter sewer.
Constrcting Manhole with R.C.C. top slab in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm. nominal size), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 Brick bats 40 to 50 mm. size) inside plastering 15mm thick with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20mm nominal size) finished smooth complete including curing and testing. (i) Inside size 900mm x 1200 mm and 1.50 meter deep including heavy duty FRC Manhole frame and cover of size - 560 diameter total weight of cover and frame to be not less than 128 kgs (Wt. of cover 64 kg and Wt. of frame 64 kg) (A) with 230 mm thick walls of brick masonary using bricks having crushing strength not less then 35 kg/sq.cm in cement motar 1 : 5 (1 cement : 5 coarse sand) (2) B type depth 1.50 metre for 150 mm diameter sewer.
PHE 04.00 Equipments Water Treatment Plant For Expansion Building: Supply, Installation, Testing and Commissioning of water treatment plant having centrifugal multistage filter feed pumps 2 (1W + 1S) of 70 LPM @ 3.5 Bar, PSF, ACF, Softener including Resin Treatment (Na++), Anti-scaling treatment to provide scaling free water, including inter-connected piping works, valves, pressure gauges, auto regeneration, auto rinse and auto filter mode, control panel for auto cut-off, auto on with IP55 protection with all necessary equipment, piping and connected activities as per specification and operating conditions as mentioned by manufacturer or as directed by engineer in charge. System Capacity: 40,000 litres per day. Make: Aquatics / Linc Digital (Ion Exchange) / Cleantech Water.
Hydro-pneumatic System for Expansion Block: Supply, Installation, Testing and Commissioning of Compact Self Contained Skid Mounted Hydro pneumatic System: Design, engineer, procure, supply, test and commission a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient pump, IE3 motors, skid mounted, complete ready-to-connect packaged variable speed water pressure booster station. The packaged variable speed water pressure booster station shall be complete with vertical multi stage centrifugal pumps connected in parallel, high efficiency IE3 motors, an air-cooled external variable frequency drive, intelligent multi-pump controller, the controller shall be mounted in a control cabinet with an IP 67 enclosure of suitable rating having Potential free contacts to monitor On/Off & Trip status with necessary sensors/switches; hot Dipped Galvanised suction and delivery manifolds; isolation ball valves on suction and discharge of each pump; non return valve on discharge side of each pump; hot dip galvanised common base frame; and diaphragm pressure vessel. Complete (Skid mounted / wall mounted) electrical control panel comprising of all accessories such as PLCs for cascade operation of all pumps and having BMS compatibility, pressure switches, pressure transducers, control wiring and any other necessary imports etc. (list to be provided by the vendor). All installations such as electrical wiring from Electrical Panel to Pump panel, civil foundations, etc is included in this scope. Set of accessories such as NRVs, isolating valves, Hot dip Galvanized Iron suction and delivery header, pressure gauge, GI base frame, pressure switches, pressure transducers, interconnecting power, control cabling, outlet pipes size: 65mm diameter (CPVC pipe size) etc. complete. Soft Water Supply: Set of Pumps: 3 (2 Working + 1 Standby) Flow Rate (Each Pump): 100 LPM (6.0 Cu. Mtr / Hr) Flow Rate (System): 200 LPM (12 Cu. Mtr / Hr) Head (Each Pump): 45 MTRS Pressure Vessel: FRP vessel of 100 litres capacity.
Hydro-pneumatic System - for all buildings (terrace): Supplying and erecting Fully Automatic hydro pneumatic booster system with cast iron housing Enclosure class IP44 minimum , with built in PTO motor protection and stainless steel impeller pump, pump model GRUNDFOS CMB 5-46 series or equivalent with 24 Liter hydro pneumatic pressurized tank capacity 8 m3/hr,Rated head :40 mtr, motor rating : 1.5 H.P. includes pressure switches, Non Return Valve, Pressure Gauge, 5 way Brass connector, with necessary Plumbing work of 25mm dia suction and delivery pipe which includes all required size of pipes, Joints valves, Bypass valve, labor all accessories required for installation of pressure pump ( Foundation work and base stand cost included)
WATER COOLERS: Providing & Erecting full SS Body (SS 304) Split type water cooler having storage capacity 160 to 175 Ltr.(Tank SS 304) & Cooling capacity 150 ltr. Per hour @ an ambient temp of 350 C.The outlet temp. of the water should drop by 150C within a hour,The water cooler should be comprising of hermetically sealed Reciprocating compressor with R134A, fan motor, Copper Condensing unit with company fabricated Outdoor Unit water tank surrounded by evaporating coil, thermostats, relay etc.complete with necessary copper tube & Insulation, M.S Chanel Stand with Painting for water tank & M.S. Powder Coated Stand for Outdoor unit with Installation. With DPELCB and 4 Way DB Box with accessory Three core Cord for connection.
WATER COOLERS: Supplying and erecting water filter cum purifier with ultra violate technology. (Aquaguard / waterdoc model or equivalent symphony/ crystal/videocon model)
R.O. Plant: Supplying & erecting reverse osmosis (RO) water purification system with M.S. powder coated pedestal frame, prefilter housing carbon filter suitable buster DC pump, auto low & high pressure switches with following size of LPH capacity & erected as directed with one year comprehensive maintenance guarantee. [F] 500 LPH with 3 phase Raw water pump of 1000LPH @ 3.0 kg/cm2 (1No - Kirloskar /CRI /Lubi), Dual media filter 13"x54" - (1No), Micron catridge filter 20" x 4.0"-1No, High pressure pump 1000LPH @ 11kg/cm2 - (1No - lubi/ Shimge/ CRI), RO Membrane housing with RO membrane of 40*40 - (2 Nos), RO pressure tube 4" x 2E -(1No), 0-2400 LPH Rotameter ( 2Nos), Dosing pump 0 -6 LPH - (1 No), with 100 Ltr Dosing tank - (1 No), with Recovery Rate 50%.
DRAINAGE SUMP PUMP: Providing and fixing compact monoblock dry motor non-clog submersible pumps of suitable rating, with non-clog free flow open impeller, solid handling capacity of up to at least 28mm suitable for operation on 415 volts +10% , 3 Phase, 50Hz, A.C supply, speed 2900 RPM including oil chamber (optional), guide wire for lifting & lowering of pump, auto-coupling, M.S. galvanized lifting chain, duck foot bend complete. The pump sets shall be supplied with required accessories & as per specification with the following : (a) Necessary cables from pump set to control panel (position of panel as marked in drawings).- 1 Set (b) Electrical control panel having IP67 rating suitable for receiving incomer cable to conncet complete. - 1 Set. (c) Each set consist of 2 nos.of pumps - 1 working & 1 stand by (Complete set as above with 2 nos. pumps including cost for valves, piping, Control Panel and Cabling, Level Controllers etc as required and as specified). The entire system alongwith pumps & control panel must be sourced from single manufacturer only for unit responsibility. Discharge: 54 Cu. Mtr / Hr; Head: 15 Meter (minimum)
Sec. 3.0 Electrical works ELW 01.00 Substation Equipment and substaion Auxiliary Supplying & Erecting Rubber mat 1.1 KV grade ISI marked 1000 x 1000 x 4 mm size.
Supplying Standard First aid box with all the Standard contents.
ELW 02.00 MV Switch Gear And Power Panel Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. MAIN SUB PANEL_EXTENSION_BUILDING As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. GROUND FLOOR PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. FIRST FLOOR PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. SECOND FLOOR PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect THIRD FLOOR PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect FOURTH FLOOR PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect FIFTH FLOOR PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect UPS OUTGOING PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect LIFT POWER PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect BASEMENT PLUMBING PANEL_EXTENSION_BLOCK As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect TERRACE PLUMBING PANEL_EXTENSION_BLOCK (OUTDOOR DUTY) As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. TERRACE HVAC PANEL (OUTDOOR DUTY) As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. MAIN PANEL_STUDENT HOSTEL As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. TYPICAL FLOOR PANEL_STUDENT HOSTEL As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. EMERGENCY PANEL_STUDENT HOSTEL As per Single line diagram
Supplying, unloading at site, shifting to site, assembling, leveling, grouting, erecting, Testing, & Commissioning compartmentalized type Panels with powder coated fabricated from CRCA sheet & folded channel totally enclosed cubical type with pad lock arrangement complete in all respect as per detail tedner specifications. The successful tenderer will have to prepare general arrangement with dimensions & get it approve through Engineer In charge / Consultant.Panels should be as per detail single line drawing with required nos of incoming and outgoing feeders and accessories complete in all respect. GF PANEL_STUDENT HOSTEL As per Single line diagram
ELW 03.00 Distribution Board DISTRIBUTION BOARD Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. TPN Distribution Board : Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 12 SPMCB as outgoing per phase (i.e. 16 way TPN D.B.) with 16 way PPI kit
Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 8 SPMCB as outgoing per phase (i.e. 12 way TPN D.B.) with 12 way PPI kit
Supplying, assembling, grouting, levelling, installation, Connecting & testing D.B of specified make but without MCB / ELMCB/MCCB etc but with all internal busbar as per requirement. Supplying, erecting, testing and commissioning of only TPN D.B. with space for FPMCB as incoming and space for DPELMCB and 4 SPMCB as outgoing per phase (i.e. 8 way TPN D.B.) with 8 way PPI kit
SPN Distribution Board : Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 12 SPMCB as outgoing per phase (i.e. 16 way SPN D.B.
Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 8 SPMCB as outgoing per phase (i.e. 12 way SPN D.B.)
Supplying, erecting, testing and commissioning of SPN D.B. with space for DPELMCB as incoming and 4 SPMCB as outgoing per phase (i.e. 8 way SPN D.B.)
Supplying, erecting, testing and commissioning of SPN D.B. suitable for outdoor mounting IP 65 with space for DPMCB as incoming and 2 SPMCB as outgoing (i.e. 4 way SPN D.B.) equivalent to Hensel make cat No. KV 7104 or Legrand make cat.no. 601994
VTPN Distribution Board: Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush / surface mounted double door (IP54) fitted with insulated copper busbar, isolated neutral link, earth bar and DIN rail, confirming to IS 13032 and BS 5486-1986,IP-54 suitable for 63/100 AMP TPN MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be used of same company of MCB to be used) 8 way outgoing
MCB 's and its Accessories Supplying, Assembling, levelling, connecting & testing following MCB / ELMCB / MCCB etc in boards as specified in 8.1, 8.2. Miniature circuit breaker single pole 6A to 25A. suitable to operate on 240V. A.C. system and having breaking capacity 10 KA to be erected in existing box. Confirming to IS 8828 / 1996 with ISI Mark.
Providing & erecting 240V MCB double pole switch for motor & inductive load (C Curve) having 10 KA breaking capacity & confirms to IS: 8828 in existing box having following capacity. 6 to 32 A DP MCB
SITC of 6A / 10A / 16A / 20A / 25A DP RCBO (RCCB+MCB) (30mA)
SITC of 32 / 40 A DP RCBO(RCCB+MCB) (30mA)
SITC of 32 A DP RCBO(RCCB+MCB) (100mA)
SITC of 40 A DP RCBO(RCCB+MCB) (100mA)
SITC of 63 A DP RCBO(RCCB+MCB) (30mA)
SITC of 63 A DP RCBO(RCCB+MCB) (100mA)
SITC of 63 A FP RCBO(RCCB+MCB) (300mA)
SITC of 6 to 32 A TP MCB
SITC of 6 to 32 A FP MCB
SITC of 40 A FP MCB
SITC of 63 A FP MCB
SITC of Sheets steel powder coated enclosure suitable for incorporating One/Two nos. MCB.
SITC of Sheet steel metal enclouser for FP MCB
Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards 1.2KV Protection level FP, Class 's', (Imax-15KA, 8/20µS) Cat 003954
Surge Protection Devices (SPD) Supplying, Assembling, levelling, connecting & testing following VSPs etc in boards 1.2KV Protection level DP, Class 's', (Imax-15KA, 8/20µS) Cat 003974
SITC of Blank Plates
Caution Board : SITC of Caution boards of size 150 x 150 mm. to be supplied & fixed on the D.B.
MCCB SITC of 100 A FP MCCB with Sheet steel metal enclouser
SITC of 125A FP MCCB with Sheet steel metal enclouser
ELW 04.00 MV Cabling CABLES Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 400 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 240 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 120 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 95 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 70 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 50 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 35 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Aluminum Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 25 Sq.mm x 3.5C Al. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 16 Sq.mm x 4C CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 10 Sq.mm x 4C CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 6 Sq.mm x 4c CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 4 Sq.mm x 4c CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 6 Sq.mm x 3c CU. Cable
Supply, testing and Laying and commissioning of XLPE steel wire/flat armoured cable of 1100 V grade of Copper Conductor of following sizes in ready made trench or mounted on wall with necessary clamping arrangement or in pre-laid RCC hume pipe with necessary cable identification mark to be provided at distance of 10 mt. The vertical cable on wall shall be drawn in prelaid conduit for vertical mechanical support. 4 Sq.mm x 3c CU. Cable
ELW 05.00 Cable Termination Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 400 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 240 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 120 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 95 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 70 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 50 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 35 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 25 Sq.mm x 3.5C Al. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 16 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 10 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 6 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 4 Sq.mm x 4C CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 6 Sq.mm x 3c CU. Cable
Supplying & fixing single compression type Brass glands & making joint with necessary bi metalic crimping socket of long nack type connecting the same to various equipment/panel/DB etc. for the following sizes: 4 Sq.mm x 3c CU. Cable
ELW 06.00 Cable Tray Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 50 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 300 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 450 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI ladder type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 600 x 100 made out of 2 mm thick ladder type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 150 x 100 made out of 2 mm thick perforated type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 300 x 100 made out of 2 mm thick perforated type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 450 x 100 made out of 2 mm thick perforated type
Supply & Installation of hot dip GI perforated type cable tray with all accessories like coupler, GI nut bolts,bend, tee, reduser etc as per specification and drawings complete with all required hardware : 600 x 100 made out of 2 mm thick perforated type
Supplying , fabricating and installation of various sizes clamps for cable tray supports using available M.S. sections & rod as per drawings or instructions of engineer in charge or consultant including applying zinc chromate yellow oxide and two to three coats of required enamel paints with anchor fasteners etc.
ELW 07.00 Internal Wiring WITH MODULAR TYPE SWITCHES Wiring of points to be done in open/concealed manner in 25 mm dia medium guage Rigid PVC FRLS pipe. Wiring shall be done with FRLS type copper flexible wire of 650V/1100V. Separate pipe should be taken for circuit mains. Nos of ciruit of the same phases may be taken in same conduit .The circuit shall be laid in 25/40 mm dia medium guage rigid PVC FRLS pipe.The point rate shall include all the necessary piping and wiring from sub panel / Distribution board to switch board & switch board to the batten holder / angle holder / connector / ceiling rose all inclusive except sub panel / Dist board. The wiring shall be done as per relevant prevailing standard. The looping of the wiring should be done in the switch boxes or light and fan point outlet boxes to avoid the junction boxes. The junction boxes and switch boxes for the ceiling light point, fan point etc shall be minimum 60/75 deep. All the necessary jarry in brick plastered walls should be done with machine cutter only , also jarry should be filled with cement, sand and wire mesh as required, the material cost for rough finish shall be included in point rate.Whenever pipes are required to be laid in flooring shall be of.Wiring should be done as per distribtion details. Each circuit should have dedicated phase, neutral & earth wire. Wire sizes to be used as under For Light Points /fan point/ wall fan / 6A 3 Pin Plug - DB to SB - 2.5sqmm for Phase & Neutral & 1.5 sqmm for Earth - SB to on board Point - 1.5 sqmm for Phase & Neutral & Earth For 6A Plug point. - 1.5 sqmm for Phase, Neutral & Earth For 6/10/16A general purpose plug point - 2.5 sqmm for Phase, Neutral & 1.5 sqmm Earth For 16A plug point for A/C and Geyser - 4 Sqmm for Phase, Neutral & 2.5 sqmm Earth For 20/32A plug point - 6 sqmm for Phases, Neutral & 4 sqmm Earth No zarry will be allowed in expose brick work. The conduit shall be provided when the walls are under construction. The pipes in slab shall be laid before the slab is casted. One light point controlled by one single way 6 A switch.
Loop light point to be controlled from same switch.(Looping from first point)
One light point controlled by two, two way 6 A switch
One ceiling fan outlet point controlled by one 6 A switch and hum free electronic type step regulator and cast iron fan box.
One 6 A x 5 pin 250 Volt universal socket outlet point controlled by one 6 A switch located on switch board.
6 A x 5 pin 250 Volt universal switched socket outlet point at convenient location.
6/16 A x 250 V switch socket point on one switch box with 2.5 sqmm flexible wires and phase and neutral and 1.5 sq nm flexible Cu. wire as earth wire. The rate should include conduiting upto DB.
6/16A x 250 Volt switched socket outlet point for body storage with 4 sq.mm wire for phase and neutral & 2.5 sq.mm earth wire.
-Do- as above but switch and socket at different location
Exhaust fan outlet point with 6A 5 pin socket controlled by one 5 single way switch located at different location.
Bell point controlled by Bell push switch with Buzzer / bell of approved make.
SITC computer power supply point with 2 nos of 6 amp 5 pin socket with 1 no. of 6/16 Amp. socket with 1 no 16 A Switch with indicator & wiring of computer point will be done through 2 nos.of 2.5 sq. mm Cu. wires as phase & Neutral and 1 nos. of 1.5 sq.mm.as earth wire. .( This cost includes the wiring from DB to Computer point.)
20 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 2 module legrand make Cat no.056669 or equivalent but without cost of wiring and piping.
32 A x 250 V plug & socket with interlocked switched socket, DP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56669 or equivalent but without cost of wiring and piping.
32 A x 415 V plug & socket with interlocked switched socket, FP MCB and surface mounting box IP 66 with DIN rail for 5 module legrand make Cat no.56674 or equivalent but without cost of wiring and piping.
METAL CLAD SWITCJH SOCKET SITC of Metal Clad Switch Socket with 10A SP MCB (2P+E)
SITC of Metal Clad Switch Socket with 20A DP MCB (2P+E)
SITC of Metal Clad Switch Socket with 20A FP ELMCB (2P+E)
SITC of Metal Clad Switch Socket with 32A FP ELMCB (P+E)
MAINS The mains is considered from the meter/sub panel to the individual distribution boards. Supplying and Laying mains with 4 nos. of 25 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 10 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 50 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 4 nos. of 16 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 6 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 4 nos. of 10 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 4 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 40 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Providing mains with 4 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 2 nos 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 4 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 6 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 4.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Providing mains with 2 nos. of 10 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 nos 6.0 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI and FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 2.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 2.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying and Laying mains with 2 nos. of 1.5 sq mm Cu. PVC insulated FRLS flexible wire with ISI approval for 650 V/ 1100 V and 1 no 1.5 sqmm Cu. PVC insulated flexible wires with ISI approval for 650 V/ 1100 V as earth wires to be drawn in 25 mm diameter rigid PVC conduit of medium guage having ISI amd FIA approval with all necessary accessories.
Supplying , fabricating and installation of various sizes junction boxes made out to 14 gauge sheet with all necessary accessories & hardware etc All the necessary fabrication required will be included in the scope of contractor. Scope also includes two coat of primer and two coat of paining of each items on all the sides complete in all respect.
ELW 08.00Light Fixtures and Fans Supplying and erecting, testing and commissioning of 21W 4' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash s (Minimum 2200 Lumens)
Supplying and erecting, testing and commissioning of 42W 7'/8' Feet LED Recessed Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash s (Minimum 4200 Lumens)
Supplying and erecting, testing and commissioning of 21W 4' Feet LED Surface/Suspended Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash S, complete with all hanging & mounting accessories.(Minimum 2400 Lumens)
Supplying and erecting, testing and commissioning of 42W 7'/8' Feet LED Surface / Suspended Hanging Mounted indoor Channel Linear Lights Fittings with opal diffuser-Make equilavent Regent make Slash S, complete with all hanging & mounting accessories.(Minimum 4200 Lumens)
Supplying and erecting, testing and commissioning of 28W 7'/8' Feet LED Surface Mounted indoor Channel Linear Wall washer Lights Fittings with opal diffuser-Make equilavent Regent make Slash Asymatric, complete with all hanging & mounting accessories
Supplying and erecting, testing and commissioning of 36W LED Recessed Mounted Square (600 x600 mm.) indoor Panel type -Make Philips RC380 LED42S or equilavent (Minimum 4200 Lumens)
Supplying and erecting, testing and commissioning of 50W LED Recessed Mounted Square indoor Panel with opal diffuser-Make Philips RC380 LED72S or equilavent (Minimum 7200 Lumens)
Supplying and erecting, testing and commissioning of 1x21W 1200mm LED Surface Mounted indoor Linear Bright Battern Lights Fittings -Make Phillips or equilavent ( BN021)
Supplying and erecting, testing and commissioning of 1x10W 600mm LED Surface Mounted indoor Linear Bright Battern Lights Fittings -Make Phillips or equilavent ( BN021)
Supplying and erecting, testing and commissioning of 20W 4 ' LED Surface Mounted indoor Battern Lights Fittings - Philips or equilavent (BN100C LED20S) For Single lamp.
Supplying and erecting, testing and commissioning of 40W 4 ' LED Surface Mounted indoor Battern Lights Fittings - Philips or equilavent (BN100C LED40S) For Double lamp.
Supplying and erecting, testing and commissioning of 27W Circular LED Recessed Mounted indoor Lights Fittings with High Efficency Translucence Diffuser -Make Wipro or equilavent ( Halo,CDSL-11R033HP57)
Supplying and erecting, testing and commissioning of 13W to 17W Circular LED Recessed Mounted indoor Lights Fittings with High Efficency Translucence Diffuser -Make Wipro or equilavent (CRDL11-R013HP57)
Supplying and erecting, testing and commissioning of 20W Circular COB LED Recessed Mounted indoor Lights Fittings with 38 degree angle -Make Regent make Aston
SITC of LED Strip Light Minimum 7.2W -240 LED per meter,(2 wire, IP-65) with non integral suitable Driver complete in all respect..
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 18W LED - Philips Make SM251 LED20S.
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter 12w LED - Philips Make SM251 LED12S.
Supplying and erecting, testing and commissioning of 26W LED Surface Mounted Down Lighter -Make Wipro or equilavent ( Halo,CRDL-11S033HP57)
Supplying and erecting, testing and commissioning of 1270mm dia LED Hanging Light Point - Klite Make Infinity KL-3232 36W or equivivalent.
Supplying and erecting, testing and commissioning of Wall Mounted LED Black Light -Crompton or equilavent (Type-STUD-LBHP-10-CDL)
Supplying and erecting, testing and commissioning of LED Surface Mounted Down Lighter -Make Regent Rea IP65-35w or equivivalent ( EXTERIOR-IP65)
Supplying and erecting, testing and commissioning of LED Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton or or equilavent (IPFC111LT8-16 1X 20W)
Supplying and erecting, testing and commissioning of LED Surface Mounted Industrail Corroson proof Fixture Ip 65 -Make Crompton or or equilavent (IPFC111LT8-16 2X 20W)
Supplying and erecting, testing and commissioning of 5W Foot Light Point Outdoor Duty IP 67
Supplying and erecting, testing and commissioning Hanging Light Point -Phillips or equilavent (Type -QPG 303) (Lamp -12 to 14w led e27)
Supplying and erecting, testing and commissioning (F) 12W LED Under Water Light,12V DC including Driver,IP-67 with die-cast/deep drawn housing with impact resistance clear toughened glass.
Supply,Installation, testing and commissioning following sizes ceiling Fans with 5 step electronic regulator. 48" Dia Sweep Ceiling Fan as per approved colour & equivalent to crompton make high speed Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with condenser A.C. 230 V. 50 Cys. 1200 mm. sweep complete, canopy and 30 cms. down rod erected on existing hook or clamp with 24/0.2, 3 core flexible wire with earthing [ Make shall be approved by Engineer in charge]
Supplying and erecting 19/20mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with necessary 24/O. 2 flat 3 core flexible wire with ear thing.
Supplying and erecting approved make low noise decorative exhaust fan having size 200mm with 1350 RPM with square frame.ABS body with inbuilt lowers & square frame.
Supplying and erecting single phase approved make industrial exhaust fan suitable for medium duty ring mounted low noise operation suitable for medium duty having following dia size and maximum speed in RPM. (A)305 mm dai 900 RPM (CAT-2)
SITC of suitable M.S. louver shutter of the Exhaust fan.
ELW 09.0 EARTHING EARTHING PIT Supplying & erecting in earthpit of minimum bore dia. 225mm size approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having 200-250 Micron galvanising, connection terminal dia of 14 mm with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for following type of applications with chamber and heavy duty cover.(approved make OEM has to submit test certificate including value of earth resistane of installation. -Length of Pipe : 3 Mtrs. -Back filling Compound :2 nos Bags of 25 Kg
Earth wire/strips : Supply and laying cu. earthing required size strips for interconnecting the earthing stations, panels, DB's etc. in built up trenches, on walls/ceiling, buried in ground generally as specified and shown on drawings complete with : a) Fixing accessories. b) Corrosion protection of buried conductors with bituminous coating and covered with PVC tapes. 25 x 3 mm/ 32X6mm / 50x6mm CU. strip/ 38x6 Cu earth link
SITC of No.8 gauge bare cu. earth wire
ELW 10.00 Miscellaneous PVC PIPES Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 25 mm dia with GI pulling wire.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 32 mm dia with GI pulling wire.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 40 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 50 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 75 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 90 mm dia.
Supplying and laying following sizes PVC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 110 mm dia.
Supplying and laying following sizes DWC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 200 mm inner dia.
Supplying and laying following sizes DWC pipe of approved make including excavation of trenches, laying the pipe as per layout and drawing and re-filling the trenches etc. complete as directed. Heavy gauge pipe in Open / Concealed manner minimum 63 mm Outer dia.
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. 25mm
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of coupling, PVC bushes, Check-nuts etc. complete of following sizes. 32mm
SITC of of 3 compatement 225 mm x 38 mm, 1.6mm thick, under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet.
SITC of of 1 compartement 100 mm x 38 mm, 1.6 mm thick, under floor metal trunking/race way with all accessories made out of hot dip pre galvanized metal coated steel sheet.
SITC of 3 compartment Access outlet / service box of 250 x 250 x 60-75 mm with all accessories made out of high pressure die cast material suitable for above race ways .
SITC of 2 compatement 100 mm x 50 mm wall trunking/race way with cover and all accessories made out of PVC .
Fire Stopper SITC of Equivalent to Hilti make Hilti Mineral Wool Board System Providing Fire resistant board system with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The fire resistant board system shall comprise of a mineral wool board coated with an ablative coating CP 670 at 0.7mm dft. The mineral wool board should be of min.160 kg/m3 density. All contact surfaces and cavities shall be sealed with a joint filler CP 606. The service lines could be of various types like electrical cables trays, metal pipes, etc. The product shall be age tested for as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 38 g/l as per LEED 2009. The product shall bear the UL and FM approval logo on the packing where applicable.
SITC of Equivalent to Hilti make CP 636 Firestop Mortar Providing & fixing Fire Barrier mortar with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls for passing service shafts. The service lines could be of various types like electrical cables trays, metal pipes, GI Ducts for AC, etc. The product shall be age tested as per Dafstb and DIBT standards. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96. The product shall be tested and approved by third party agencies such as UL and FM. The mortar should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.
SITC of Equivalent to Hilti make CP 620 Expanding Seal Providing Fire expanding foam with minimum 2 hours fire rating when tested in accordance with BS 476 part 20 and UL 1479 for horizontal openings in fire rated floors or slabs and vertical openings in walls made of concrete/ masonry or Gypsum for passing service shafts. The expanding foam expands seven times its volume to fill the cavity at the time of dispensing the material and shall fully cure within two minutes after dispensing. The product shall be age tested as per Dafstb and DIBT standards. The product shall provide water tightness when tested for W rating as per UL standards and shall be tested for providing a sound insualtion of 50 db when tested in accordance with ASTM E 90. The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 1.3 g/l as per LEED 2009. The product shall be tested and approved by third party agencies such as UL & FM. The product should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable.
ELW Sec 11.00 Lighitning Protection SITC of 8 mm dia solid Aluminium Conductor for roof top mesh grid and tested as per IEC 62561- 2 conducted in the Govt. accredited thirty party laboratory to meet the requirement of IS/IEC 62305 with Required Accessories - Aluminium Holding clamp at every 1 mtr distance, Aluminium/SS cross splicer at every crossing of Alu. conductor, Expansion piece with connectors at every 20 mtr distance, Aluminium straight Splicer to connect conductors. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230
Supply, installation, testing and commissioning of test link complete with inter connections between aluminium round conductor & GI strip or GI strip to GI strip all fixing accessories etc required for complete installation, Complete in all respect with all required accessories.
SITC of Vertical Air Termination Solid aluminium with Base- 10 mm dia and 1000 mm long. Air Termination Base tested for conditioning, Ageing Test & Lightning impulse current withstand test: 100 kA of 10/350µs waveform in an accredited Third party laboratory as per 6.3 & 6.4 of IEC 62561-1 2017 protocol with MAST 34mm dia 3000 mm long- Cold Galvanized
Down Conductor System SITC of 10 mm MS Round Solid Conductor having smooth surface Should be tested and use exclusively for lightning protection (Vertical Riser/Down Conductor which shall be concealed in Column) to meet the requirement of IS IEC 62305 With Accessories - Earthing stud of dimension SS-75mm OD plate with 10mm dia tail connector used in structural steel ring earthing system to meet the requirements of IS/IEC 62305. (For Interconnecting the Column and the Terrace AL Conductor / Strip/Flat), SS Cross Connector to connect Earth fixing point to vertical raiser/Down conductor, SS Straight Splicer at every 4 Mtr to connect MS conductor in column, Bonding /Rebar Clamp at every 3 mtr suitable for interconnecting round conductor with reinforcement inside the concrete for structural earthing system, SS connector -To connect external conductor 8- 10 mm with earth fixing point. All Accessories should be tested as per IEC 62561-1 2018 Cl. 6.3 for conditioning & Ageing Test & 6.4 for Lightning impulse current withstand test: 100 kA of 10/350µs waveform(Ageing & Electrical test ) conducted in a sequence manner & tested in the Govt. accredited Third party laboratory to meet the requirements of IS/IEC 6230
SITC of Galvanized Steel Flat 25x6 mm thickness from earth electrode directly in ground as required. Zinc coating: 500 g/m square (Approx:70 micron coating) tested and used exclusively for lightning protection earthing system and ring equipotential bonding.
SITC of Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Complete in all respect with all required accessories.
ELW 12.00 UPS Supplying and erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifier and Inverter & sealed maintenance free batteries. Three phase Input and Three Phase output with Inbuilt Isolation transformer with Unity (KVA=KW) load power factor with battery, over under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with Following size of batteries for 30 Min Backup (Minimum 46800 VAh) 40 KVA UPS with 65 AH, 60 Nos. Battery (With Provision to connect in parallel)
Supplying and erecting approved make online Un-interruptible Power Supply system with IGBT Based rectifier and Inverter & sealed maintenance free batteries. Three phase Input and Three Phase output with Inbuilt Isolation transformer with 0.9 load power factor with battery, over under voltage output with over load & short circuit protection equipment. The system housed in CRC sheet duly powder coated paint with following capacity & with Following size of batteries for 30 Min Backup (Minimum 8160 VAh) 10 KVA UPS with 34 AH, 20 Nos. Battery Certification : BIS
ELW 13.00 SOLAR SYSTEM SOLAR PLANT Design, Engineering, Supply, Installation, Testing & Commissioning of 60 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.
SOLAR PLANT Design, Engineering, Supply, Installation, Testing & Commissioning of 20 KWp Grid connected Solar PV Power Plant consisting of Solar PV modules, Power Conditioning Unit (Inverter with all accessories/ features), Junction Boxes, PVC Pipes, Cables/Wires including connectors/plugs/fuses, ACDB, Suitable Lightening Arrestor/Earthlink etc. and accessories along with Tool kit and spares for 1 year. The scope of work includes suitable mounting along with all cables, hardware, nuts, bolts etc.
ELV WORKS Sec.1.0 Telephone and Data Networking Providing and erecting ISI mark Medium class RIGID PVC PIPES of following size complete to be erected on/in wall or ceiling erected with necessary PVC fittings & Junction boxes fixed with adhesive solution & Clamps with following dia of pipes, in approved manner as directed (b) 25 mm
Providing & laying approved make Double walled corrugated pipes (DWC) of polyethylene(conforming to IS 14930 II )with necessary connecting accessories of same material at required depth in existing trench for laying of cable. below ground / road surface for enclosing cable (A)50 mm outer dia
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard approved with krone strips (c) Suitable for 50 pair
Providing & erecting main Distribution (MDF) indoor type, back mounted frame as per DoT standard approved with krone strips (e) Suitable for 200 pair
Cabling - Multipair Cables Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. (b) Armoured. (Jelly Filled) (2) Fifty Pairs.
Supplying & erecting approved make Telephone Cable electrolytic copper conductor PE insulation twisted in two pairs & wrapped with FR PVC tape & sheathed with FR PVC or HFFR outer jacket suitable for telephone wiring & confirming to C-DOT erected in existing pipe. of following size of conductors & nos. of pairs. With necessary connections. A Conductor Size 0.5 mm. (b) Armoured. (Jelly Filled) (4) One Hundred Pairs.
Telephone / Data Networking Cabling Supplying & erecting approved make LAN cable of following size in existing pipe as per direction. [C] CAT - 6
Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge. (8) Modem Jack for Computer Open RJ-45. Cat. III.
SITC of Patch Panel Cat 6 UTP Keystone Type- 24 Port-Fully Loaded as per technical specification etc. as required.
Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 3 feet as per technical specification etc. as required.
Supplying, installation, testing and commissioning of UTP CAT6 RJ45 ethernet patch cord - 7 feet as per technical specification etc. as required.
Data Networking - Fiber Optic Cable and Components SITC of O. F.Cable 06F Outdoor - Armoured Unitube SM - HDPE Sheath as per technical specification etc. as required.
Providing & erecting Optical Fiber cable should be ISO/IEC- 11801 , Outer sheath FRLSZH Shall be 9µ, Single mode OS2 steel armoured cable as per ISO/IEC- 11801 Shall be able to meet Gigabit & 10 Gigabit Ethernet performance requirement specified by IEEE 802.3z (1000 Base-X) & IEEE 802.3ae (10GBase-X) Shall have water blocked construction to prevent water absorption and consequent damages. Water blocking with flooding Gel and water blocking yarn shall comply for IEC 60332-3 for flame retardant, IEC 61034- 2 for low smoke & IEC 60754-2 for toxicity & acidity. Tensile load should be 2700 Newton or higher Optical Parameters – SM, (a) Attenuation @ 1310nm(max) ≤ 0.34 dB/Km, (b) Attenuation @ 1550nm(max) ≤ 0.22 dB/Km with neccessory connections as per technical specification etc. as required. (C) 24 core Single mode
Providing & erecting Fiber Optic LC style fully loaded Patch Panel (FOPP), 19" Rack Mount with following nos. of OS2 9/125μ Pigtails as per ISO/IEC-11801-OS2 Pigtails with LC Type Connectors Shall have all accessories including coupler plates pre loaded with duplex LC couplers (OS2), pigtails for terminating fibers on the FOPP Pigtail Attenuation ≤0.3dB measured measured against reference connector Return Loss ≥ 45dB, in mated condition Pigtail Cable Information – Outer Jacket Diamter – 0.9mm, Outer jacket colour – white , Outer Jacket Material – LSZH Shall be Front Patching Type, 1U high and rack mountable on standard 19” rack with mounting arrangements (B) 24F Loaded with Coupler, Pigtail and Splice Trays
SITC of LIU 12 PORT Rack Mount - Loaded (LC) SM as per technical specification etc. as required.
SITC of PIGTAIL LC SM SIMPLEX LENGTH- 1m as per technical specification etc. as required.
SITC of PATCH CORD LC-LC SM DUPLEX LENGTH- 3m as per technical specification etc. as required.
Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. for OFC Marker, as per technical specification etc. as required.
Networking Enclosures & Accessories Supplying, installtion, testing and commissioning of ruggedized, IP54 rated outdoor Pole/Wall mountable 9U enclosure for housing power supplies, fiber LIUs, and industrial networking switch, with suitable provisions for DIN rails, cable management as per technical specification etc. as required.
Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories. (D) 15 U
Providing & Erecting Netwrok rack with following capacity with Necessary cooling fan,Cable manager,6A PDU,equipment rack with necessary mounting accessories. (H) 24 U
Supply, Installation, Testing & Commissioning of 42U (800W X 800D) floor mount closed rack complied with UL, CSA, TUV, EIA 310, DIN 41494, DIN 41494, ISO 9001, ISO 14001, IEC 297 and current industry practices, CRCA Steel Door - Plain, Vented at Bottom, Fully perforated at front and rear side, with screw fitted side panels. 19" L type mounting angles at front and rear, top and bottom cover with cable entry provision, with required accessories as per technical specification etc. as required.
Type 2 Switch: 24 Port POE Supplying, installation, testing and commissioning of Layer 2 Manageable, Stackable Networking switch having 24 # 10/100/1000Tx ports, all 24 ports shall be capable of providing PoE+ as per 802.3at, switch having a PoE power budget of minimum 370 Watts, minimum 4 SFP+ ports complete as per technical specification etc. as required.
Type 3 Switch: 24 Port Non POE Supplying, installation, testing and commissioning of Layer 2 manageable networking switch, 24 # 10/100/1000Tx ports,minimum 4 SFP+ ports complete as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of 10G SFP+ LR singlemode transceivers, 1310nm, duplex LC termination supporting distance upto 10000 mtrs, inclusive of any hardware or interfaces such as modules for populating SM-LC transceivers complete as required.
Supply, Installation, Testing and Commissioning of Wireless indoor Access Point supporting Dual band with Wi-Fi 6 operation with MIMO support 4 x 4, Minimum 3 streams, One 10/100/1000 BASE-TX auto-sensing (RJ45) PoE port with required licenses as per existing controller, as per technical specification etc. as required.
Providing and erecting IP Phone with display with all IP system supported with required licenses as per existing EPABX System as per technical specification etc. as required.
Sec.2.0 Video Surveillance/CCTV System Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Camera, 1/2.8" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Bullet Camera, 1/2.8" CMOS, 2 MP @ 25fps, Min. Illumination required 0.01 lux @ F1.4 (color), 120dB True WDR, Min. Pixels 1920 X 1080, triple stream, 2.8 -12 mm motorized focus and zoom lens, BLC, HLC, 3DNR, Privacy Mask, IR LEDs Smart IR with upto 50m IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 2 In/ 1out, PoE, H.264 High Profile and MJPEG, Inbuilt analytics Trigger line/Intrusion/Loitering, PoE Class 3 and 12V DC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 60° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant, as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR PTZ Camera with auto tracking, 1/1.9" CMOS, 2 MP @ 25fps, triple stream, Min. Illumination required 0.005 lux @ F1.6 (color) & 0.0005 lux @ F 1.6(B/W), 120dB True WDR, Min. Pixels 1920 × 1080, triple stream, 6mm –180 mm 30x motorized focus & zoom lens, BLC, HLC, 3DNR, Defog, Electronic Image Stabilitzation, Privacy Mask, IR range with 150mtr IR distance, Dual channel Audio G.711a/G.711u/AAC, 128GB SD card support, Alarm: 7 In/ 2 out, PoE, H.264 High Profile and MJPEG, PoE Class 5 and 12V DC/24VAC, IP 67, IK 10 vandal proof, Having Operating temp range : –40°C to 70° C. Certifications: ONVIF Profile S compliant, UL, CSA 60950-22, CE (EN 50130-4 & EN 55022) , FCC Part 15 & RoHS compliant. as per technical specification etc. as required.
Supplying, installtion, testing and commissioning of Video Management Software supporting ONVIF Profile S & G, PSIA, real time streaming protocol (RTSP) standards, emerging technologies in the industry, like 4K resolution, H.265 video compression codec, 3D PTZ control, Fisheye camera and multi-imager/ lens camera support, and intelligence events. Software proposed shall have scalability of 128 cameras per server with at least 128 licenses to record all the cameras from the Day 1 and expandable up to unlimited cameras. Videom Managment Software shall support simultaneous recording, live monitoring, playback/search of recorded video for up to 4K resolution on all cameras, taking snapshots and viewing presets for PTZ cameras and system management, Videowall management. Video Management Software shall support - 1) Free Firmware upgrade; 2) Lifetime software licence, must not be renewed periodically; 3) It should support unlimited channels; 4) It should support N:1 and N:M redundancy; 5) It should have calender view for better playback investigation; 6) It should support Smart Motion Detection; 7) It Should support Surrounding View feature of cameras; 8) The camera zoom in/out, controlling and setting should be able done from software; 9) The proposed softsware should be latest versin available from OEM 10) VMS Shall support scheduled backfilling of the recordings from the edge storage/SD card of cameras to the server. For details specification refer tender technical specification etc. as required.
Supplying, installtion, testing and commissioning of Server(s) required for NSM & NVMMS - Industry standard Intel based platform, rack mounted, redundancy architecture for critical hardware components, licensed Microsoft Server operating system and requisite user licenses, licensed application suites, 2 x Quad Core Intel® Xeon latest processors or better, 8 GB of RAM, 2 x 1.2 TB of SAS HDDs, minimum 2 additional hard disk drive bays for expansion, 1,280 x 1,024 Display/ video resolution, 2 X 10/100/1000 ethernet network interface card, Video memory 2GB above, RAID support built-in, DirectX 8.1 above and pre-installed DVD-R/W Drive and Appropriate Licensed Operating Systems as per NSM & NVMMS Requirement. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Network storage required with a capacity to store the content for 128 cameras for 24Hrs x 30 days at 25fps and 1080p (Minimum 96TB from day 1). It should be scalable (should have sufficient expansion bays for HDDs) for at least additional 50 cameras. Vendor shall submit bandwidth and storage calculator for the proposed camera models, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Client PC - Industry standard Intel based platform computer system. Intel Core i7 latest generation, 4 GB of RAM DDR3 ,1 TB SATA II hard drive for OS and VMS applications, NVidia card 1 GB graphics card , 1600 x 1200 or higher screen resolution, 1 X 1000Mbps ethernet network interface card ,16x DVD+/- RW Drive alongwith appropriate licenced Operating System, licenced applications suites from OEM and application licences as per the technical specifications etc. as required.
Supplying, installing, testing and commissioning of 65-inch, LED Panel, 16:9 Aspect ratio, 350 cd/m2 Brightness, Anti-glare panel surface with viewing angle 176 degree, 4K pixels resolution, Video Input Interfaces : HDMI Type A Connector x 2, Mini D-sub 15-pin x 1, 20 Watt Built in Speakers with wall mount bracket as per technical specification etc. as required.
Sec.3.0 Fire Detection & Alarm & Digital EVAC System SITC of Microprocessor based Net-workable Analogue Addressable Fire Alarm Control Panel. The Panel shall be compliant with EN54-2, EN54-4 and approved by LPCB. The Fire Alarm Control Panel shall have expandable capacity from 2 loops to 8 loops. The Panel must have Full colour 800 x 480 LCD with resistive touch screen and automatic backlight dimming. The Panel must also have the capability to take Addressable Intelligent Wired and Wireless Devices on same loop. Each loop shall have a capacity of 127 analogue Addressable devices and 127 Base sounders/Base Sounder Beacons. The panel shall have an event log of minimum 10,000 events @ 1 second resolution, Filterable and Printable. The Panel shall have Three access levels. Panel shall support upto 5000 Cause & Effects entries, with upto 20,000 inputs controlling & 20,000 Controlling outputs across the network. The Panel shall have capability for Peer to Peer networking through RS485 network card. The Panel must have 4 inbuilt programmable sounder circuits, each circuit rated at 2.5A.The Panel must have inbuilt 3 programmable inputs and 5 inbuilt programmable relay outputs. The Panel shall have up to sub-addressable 512 programmable Inputs/Outputs via optional RS485 COMMS serially connected expansion cards. The Panel shall have 240 V AC power supply along with automatic Battery Charger. The Panel shall be fully expandable via common plug in loop driver boards. The user shall have a choice of using the panel with 5.25 Amp or 10.25 Amp power supply unit which is inbuilt in the FACP and should be approved to EN54-4. The Panel shall have configurable via USB port to PC or memory stick. The Panel shall have dedicated RS232 serial port for optional printer. Approved by LPCB, All Loop installed from day 1 complete as required. as per technical specification etc. as required.
SITC of Active Repeater Panel to be integrated with Fire Alarm Control Panel,larger display Full colour 800 x 480 LCD with resistive touch screen and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels, Panel should compliant with EN54-2, EN54-4 and Approved by LPCB. as per technical specification etc. as required.
SITC of Response Indicator - Dual LED (Metal square plate type). as per technical specification etc. as required.
SITC of Sensor common mounting base, includes stainless steel contacts, slim profile - only 8mm, quick connection via square cable clamps, facility for remote indicator, Approved by LPCB. as per technical specification etc. as required.
SITC of Sensor isolator mounting base, includes stainless steel contacts, slim profile - only 8mm, quick connection via square cable clamps, facility for remote indicator, Approved by LPCB. as per technical specification etc. as required.
Supplying, installation, testing & commissioning of intelligent aspiration detector having IS or BS (EN 54) (Vds approved) or NFPA 72 (UL/ULC/FM approved) with Latest Amendment for area coverage of minimum 5000 sq. ft. complete as required.
SITC of Analogue Addressable Single Output Module . which Includes a single output, flying leads for easy installation. Electronically addressed, Approved by LPCB & Vds. as per technical specification etc. as required.
SITC of Analogue Addressable Single Input Module. which Includes a single monitored input, flying leads for easy installation. Electronically addressed, Approved by LPCB & Vds. as per technical specification etc. as required.
SITC of Duct Detector with 0.6 Mtr Unique sampling Tube. as per technical specification etc. as required.
Manual Fire Detection, Alarm and Control System SITC of 4 Zone Fire Alarm Control Panel, with 16X2 Character LCD Display, complies with UL - 864 and NFPA-72,Standards. Approval: UL-Listed Optional: 1) Provision to connect zone wise sounder (RE-25ZS) provided in a seperate cabinet. 2) Provision to connect zone wise relay (RE- 25ZC) provided in a seperate Cabinet 3) provision to connect repeater Panel through RS-485 with RE- RP Series.with
SITC of Zone wise Relay contact box for 4 zones - RE-2554 fire alarm panel
SITC of Zone wise Sounder contact box for 4 zones - RE-2554 fire alarm panel
SITC of 5 Amps External Power Supply panel (Self Power)
SITC of Heat Combination (ROR and Fixed Temp) Detector with base.- Approval UL Listed.
SITC of Multi Sensor (Smoke and Heat combination) Detector with base - Approval: UL Listed.
SITC of Manual Pull Station - Dual Action Red in Color Approval: UL Listed with Supply of Back box for Manual pull station.
SITC of Conventional Sounder cum strobe with 24V DC, Audiable Sound 75 db @ 1 mtr range (16 V DC). It is used for Fire, Burglar & Emergency Alarm System, Low current consume @ 47 -73 mA Candela: flashing every second, 4 candela settings:15/30/75/110cd output and 2 different tone audible sound. Make: Ravel - Approval: UL Listed.
Digital Evac / Public Address System. SITC of Controller Heart of the Plena Voice Alarm System EN 54‑16 certified Built-in message manager and 240 W amplifier Six‑zone outputs 6 emergency and 6 business triggers as per technical specification etc. as required.
SITC of Power amplifier, 480W as per technical specification etc. as required.
SITC of Ceiling loudspeaker 6W, metal with clamp and back box as per technical specification etc. as required.
SITC of Cabinet loudspeaker 6W as per technical specification etc. as required.
SITC of Music source, USB/SD/Tuner MP3 playback from SD card and USB inputs FM tuner with RDS, presets and digital control Simultaneous operation of SD/USB-player and FM tuner Separate outputs for digital source and FM tuner
SITC of Volume control unit, 36W as per technical specification etc. as required.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. (A)Speaker cable Single pair, 2-core, 1.5 sqmm
Sec.4.0 Access Control System “Providing & erecting approved make Fingerprint and card based premium Door controller with LCD and Keypad having following features.”(A) Optical Fingerprint and card based Reader (Card personality Module not included) “(B) Dot – Matrix LCD and Touch sense Keypad “(C) Built-in interfaces like door lock, door sense exit Reader, Exit switch, Ethernet RS485, Aux Input & aux output port “(D) 5000 Events, access Control, Time Attendance, Tamper Detection “(E) 4 LEDS and Buzzer”
“Providing & erecting approved make Card Reader having following features. “[A] Wiegand/ RS232 Interface “(B) Power supply from COSEC Door controller or through Separate Adaptor “(C) Compatible with any COSEC Door controllers “(D) 4 LEDs (Status, Alarm, Allowed and Denied) and Buzzer “(E) Tamper Detection”
“Providing & erecting approved make Card Personality Module (CPM) having following features “(A) EM proximity Card Reader Module [Low Frequency] “(B) Compatible with any COSEC Door Controllers and COSEC Reader CA “(C) Supports EM Proximity Card”
Providing & erecting approved make Application Software Platform for 500 User having following features “(A) With 100 Users “ (B) Expandable up to 500 Users with COSEC USER 100 “(C) Supports up to 16 Door Controller “(D) Basic Access Control Basic Time Attendance and Enrollment Management (E) Compatible with all COSEC Hardware “(F) Add Other COSEC software modules on requirement.
Providing & erecting approved make Time Attendance Module (TAM) Having following features “(A) Comprehensive Time Attendance and Leave Management Software Module “(B) For 500 Users [AS per COSEC GE PLATFORM USERS] “(C) Attendance and leave Policy Creation “(D) Integration with payroll and HRM “(E) Shift Schedule, Holiday Schedule and Past Adjustment “(F) Manually Attendance Correction “(G) Leave/Tour Application and approval “(H) Report and Charts Generation
“Providing & erecting approved make Access control Module (ACM) having following features (A) Comprehensive Access Control Management (B) For 500 Users [AS PER COSEC GE PLATFORM users] (C) Time, User and Zone Based Access Control (D) Access Zones, Access Modes and Access Levels (E) Advanced Access Control Feature like 2-person rule, First in user rule, Antipass Back, Guard Tour, Duress Detection and more (F) Various Reports Generation
Supply, Installation, Testing & Commissioning of Drop Bolt Or EM Door Lock as per Door type & site Location requirement.
Sec.5.0 Cable TV Distribution System Providing following type of Modular Type Accessories mounted with pvc / metallic box covered with appropriate front plate modules erected with necessary connection. As desired by Engineer In charge. (4) TV Co-axial Socket outlet. Cat. III.
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (b) RG – 6.
Providing & Erecting approved make following size of TV Co-axial flexible cable comprising inner conductor of solid bare copper insulated with Foam PE & Secondary conductor made of poly – Aluminium film bonded Al. Braids @ suitable coverage overall sheathed with black PVC insulation. (e) RG – 11.
Sec.5.0 Audio Visual System Supply, Installation, Testing and Commissioning of 75" Smart Interactive 4K display, 7H hardness toughen anti glared glass , In-built Android 8.0, RAM 3 GB, 16 GB ROM, 10 Points Touch in Android and 20 points Touch in Windows, Smart Object recognition and responsive multi-touch, Multiple Inputs for connectivity, 15W x 2 Speakers, Inbuilt Screen Sharing Software, Slimmer Frame, Customize GUI, Wireless presentation with Quad View Option, Broadcast upto 200 Devices, Remote Display Management with required wall mount kit as per site requirement, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of 85" Smart 4K Non-Touch display , In-built Android 8.0, RAM 3 GB, 16 GB ROM, 20W x 2 Speakers , 6 no. of Beam Forming Microphones with Echo Cancellation, 50000 Hours of Life , 500 nits Brightness, Multiple Inputs for connectivity, Inbuilt Screen Sharing Software, Slimmer Frame |OPS Slot for On-Board Computer Connectivity with required mouting kit as per site requirement, as per technical specification etc. as required.
Supply, Installation, Testing and Commissioning of On-Board Computer OPS (Core i5 Processor, 8 GB RAM, 128 GB SSD) with the software as per technical specification etc. as required.
Supplying, installation, testing and commissioning of 7200 ANSI Lumens 1DLP® laser projector with 1.25-2.0:1 fixed zoom lens ,Contrast ratio 3,000,000:1,1-chip 0.67" DMD Display type, WUXGA, Inputs 2 x HDMI , HDBaseT, VGA, USB-A etc, all complete with required mounting kit as per site requirement as per technical specification etc. as required.
SITC of DLP/LCD 4000 Lumens LASER projector compatible with 4K & HDR, IP6X dust resist provides good brightness and reliability, approx 20,000 hours laser light source life and virtually zero maintenance for system, 1.3x zoom, Tilt free orientation, including portrait mode, Native Resolution ,XGS or more Contrast 25,000:1, Light Source Life 20,000 hours to 50% brightness (Eco mode) I/O Connectors HDMI x1, HDMI/MHL x1, VGA in x1, Audio in x 1, Audio out x1, USB Power (5V/1.5A), RS232, Micro USB(FW Upgrade), RJ-45 x1, wireless remote control erected as directed by engineer incharge
SITC of following standard size MW fabric Tab-Tension Tubular Motorized Screen with RF remote, Aspect Ratio-16:9, (G) 160 inch Diagonal
SITC of 135 inch Fiber Glass MW Tubular Motorized Screen with RF remote, Aspect Ratio-16:10 as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Modular Pop-Up Box / Cable cubby Includes a Universal power outlet X 2 Nos. and space for four customer-supplied cables HDMI Port X 1nos, RJ-45 X 2 Nos, as per technical specification etc. as required.
SITC of HDMI RX and giveHDBaseT/ twisted pair signal and give HDMI output ,Bi-directional RS-232 and IR signals, resolution of 4K@60 Hz at sampling rate of 4:2:0 ,Minimum data rate of 10Gbps ,HDMI signal over 180m for full HD resolution , 4K resolution upto 90m or above ,HDTV and HDCP compatible ,2K and 4K support ,3D as well as EDID pass through ,Support for Deep Color, x.v.Color™, Lip Sync, HDMI Uncompressed Audio Channels, Dolby TrueHD, DTS −HD, CEC as directed by engineer in charge (B) Premium Make (KRAMER / AMX/ EXTRON / CRESTRON)
Supplying, installation, testing and commissioning of 4K60 HDbaseT Transmitters Should have built in 2x1 switcher, 2xHDMI and 1x HDBaseT output along with 1xHDMI loopout for local monitor or an external switcher should be supplied, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of 8x4 matrix 4K video scalers cum switcher with minimum 6 X HDMI IN, 2 X STP IN and 2 X HDMI Out, 2 X STP Out, HDCP 2.2, EDID supported as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Steerable speaker : Compact Powered Multiple-Driver Digitally Steerable Column Array with Integrated DSP consisting of Minimum 8 x 3" LF, 8 x 1" HF, Class D, 16 x 100 W rms @ 4 Ohms Amplifier Channels, 120 degrees Horizontal Dispersion Vertical dispersion Variable between 10 - 100 degrees (Asymmetric & multiple beams may also be generated), Aiming angle limit +/- 70 degrees, Frequency Range (-10 dB) 130 Hz - 20 kHz, LF Beam control limit 700 HzMaximum SPL 94 dB @ 30 m, Audio inputs Analogue & AES/EBU. Standard Colour White., as per site requirement as per technical specification etc. as required.
Supply, Installation, Testing & Commissioning of Compact Full Range 6" Ceiling Speaker 50 W RMS Power @ 8 Ohms, Frequency Response (±3 dB) 105Hz - 20kHz, Frequency Range (-10 dB) 74 Hz - 20 kHz, Sensitivity 90 dB, 120 degrees conical Coverage , Maximum SPL 107 dB Average and 113 dB Peak. Transformer Taps 70/100 V: 30 W / 15 W / 7.5 W. UL and EN54 certified with steel backcan.with steel back can..as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of 40 Watt RMS Co-axial Wall Surface loudspeaker suitable for 70/100 V line, 75 Hz - 20 KHz frequency response, SPL Max.100 dB, Sensitivity 84dB, Nominal Impedance 6 Ohm, ABS Enclosure as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of 2-Channel 800W Class D Power Amplifier delivering 2 x 400W per channel at 70 V, 2, 4, 8 and 16 ohms,THD 20 Hz - 20 kHz at 1W <0.1%,Signal to Noise Ratio >112 dBA, Frequency Response 2 Hz - 40 kHz,CMR 50 dB,Sensitivity 4 dBu, as per technical specification etc. as required.
Supplying, installation, testing and commissioning of 4 in 1 Media processor - supports recording, switching, mixing and live streaming at 1080p, Supports 1080p 60/30fps video recording, Supports 4 HDMI Inputs and IP video sources, Should have minimum 1TB inbuilt storage. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Full HD 1080p, Minimum 20X Optical Zoom, 20 Presets, 30 Frames per Second, Ethernet Out, HDMI Out, 3G-SDI Out, Audio In, RS232/422 Controls, -170° ~ +170° Panning angle, -30° ~ +90° Tilting angle capturing presenter and students. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Joystick for PAN/Tilt/Zoom Cameras and Focusing, RS232C/RS455 Communication Interfaces, High Brightness OLED Display, Auto Backlit Keys.as per technical specification etc. as required.
SITC of Handheld Wireless Mic with Cardiod polar pattern,Dynamic microphone ,frequency response 80Hz-18kHz,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 30 or more channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery.The transmitter & receiver should be of metal body
SITC of Wireless Mic Lapel with condenser,frequency response 100Hz-15kHz,Cardiod polar pattern,,RF sensitivity < 1.0 Uv,Image rejection>55dB,Dyanmic range >95dB and receiver having 32 channels possible,S/N ratio >100dB A,dynamic range >95db B,distortion <1 %,frequency band:618-634MHz,more than 12hrs battery life with AA battery.The transmitter & receiver should be of metal body as per the technical specifications etc. as required.
SITC of Condenser Cardioid 18" Goose neck Microphone for Podium with back electret,with frequency response100 Hz to 15,000 Hz, Cardioid polar pattern,sensitivity of 4.5 mV/Pa and output impedance 200 ohm
Supply, Installation, Testing & Commissioning of UHF Antenna Distribution System, as per the technical specifications etc. as required.
Supply, Installation, Testing & Commissioning of UHF Wide-band Directional LPDA Antennas, as per the technical specifications etc. as required.
Supplying, installing, testing and commissioning of two way communication 10 x 6 Audio Digital Signal Processors, with Minimum 10 AEC balanced mic/line inputs, Minimum 6 balanced mic/line outputs. as per technical specification etc. as required.
Supplying, installing, testing and commissioning of Digital Processing Unit with 4 balanced mic inputs, 2 balanced Mic/Line inputs and 1 stereo unbalanced input; 1 stereo and 2 mono outputs; 2-channel USB audio interface, 6-channel Smart Mix (gate or gain sharing), Onboard acoustic echo canceler (AEC) processing, as per technical specification etc. as required.
Supply, Installation Testing & Commissioning 3 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Installation Testing & Commissioning 6 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Installation Testing & Commissioning 12 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Installation Testing & Commissioning 30 ft HDMI Interface Cable as per the detailed Specifications supports transmission of 4K Signals as per the detailed Specifications
Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 15 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required.
Supply, Laying, Testing and Commissioning of Ultra Flexible High Speed HDMI Cables HDMI Cable 20 Meter HDMI 2.0 Cable Male to Male, support Deep Color, 4K 4096 x 2160 @60Hz; 3840 x 2160 @ 60Hz 4:4:0, Minimum conductor gauge - 30AWG, gold Plating, as per technical specification etc. as required.
Supply, Laying of Shielded Twisted Pair (STP) 4Pairs 24 AWG Cable with connector, as per technical specification etc. as required.
Supply, Laying, Testing and Commissioning of Two 16 AWG conductors non- plenum Speaker Cable, for High performance cable for audio signals as per technical specification etc. as required.
Supply, Laying, Testing and Commissioning of Dual 20 AWG shielded twisted pairs with individual drain wires for Mic and Controlling Purpose, as per technical specification etc. as required.
Sec.6.0 iBMS System Supplying, installation, testing and commissioning of Intel Core I7 Processor with EISA bus and with 3GHz minimum clock speed, minimum of 8 GB RAM , 512 KB cache, Minimum of 1TB storage, optical Mouse, 104 keys key board, with 10/100 Mbps Ethernet card (Min. of 3 slots) & internal modem. Server shall be RAID 5 configured. The system shall be provided with 21" TFT monitor for viewing GUI application. The back up server takes over in case the master server fails. This will be a redundant server configuration. with 21" LED / LCD Colour Monitor. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of Laser Jet B/W Printer - A4 Size. as per technical specification etc. as required.
Supplying, installation, testing and commissioning of IBMS Server Software suite: This Web technology based software suite shall have unlimited concurrent user login licences. The client license provided shall display actual graphics as represented in the server machine. Shall be capable of interfacing with Bacnet/IP based DDC controllers, Bacnet/IP or modbus RTU 3rd party interface. Complete with Webserver for IBMS interface on Internet / Intranet. License for minimum hard/soft I/Os to be considered as per I/O Summary. Software should have the following Key features: 1. User Defined dashboard. Any Number of dashboard can be added by user. 2. Scalar/Vector Graphics to be supported. 3. Monthly Calender Dashboard: Monitor the demand/ consumption pattern for all days in a a month in a single screen. 4. Software shall be able to communicate with bacnet/ lonworks/ modbus simultaneously. 5. Mobile Platform: IPAD/ Android Compatible. 6. Software shall be Forword & Backward Compatible with 10 Years Obselation Support from OEM. 7. Display of HTML 5 Pages fromm company intranet or Internet for full smart device compatibility - with NO Java Dependancy in the Browser. 8.Database supported by software should be either SQL/oracle/db2. Also software should support 128 bit ssl encryption. Note: All required Software with original license competent with BMS software
Supply, Installation, Configuration, Programming of Web Based Energy Management & Reporting Tool software for Monitoring Building efficiency & Customization of Energy Management (For 100 Meters) Application that will Communicate with the Main Framework having Capability of Energy Profiling, Energy Mapping, Load Calculations, Predictive Energy Analysis, Energy Spectrum Analysis etc as per Functional Specifications of the Bid for 50 points. Bidders Must Consider all Application Modules and Licenses to be Part of the Bid. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for AHU's (10 Nos) VFD Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Energy Meter's ( 10 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for UPS's (2 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Breaker's Soft Data Integration on Modbus / Bacnet Over IP as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC: INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. software interface for Fire Alarm System (750 Points) Soft Data Integration on Bacnet Over IP. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for Access Control System . as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for DGs (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for STPs (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for WTPs (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for HPNs (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for RO Plant (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Installation, testing, commissioning of UL listed, BTL approved IP BASED Open protocol INTEGRATOR with Inbuilt web browser & with max 150 device capacity, multiprotocol supported & should be of the same make as the DDC : INTEGRATION OF FOLLOWING SYSTEMS ON MODBUS-rtu / BACNET: The corresponding mentioned third party vendor shall be responsible to provide serial converter [RS 485 to RS 232] and the BMS vendor to accommodate the software address required for integration. including all necessary mounting hardware and accessories. as per technical specification etc. as required. of software interface for VRV System (1 Nos.) Soft Data Integration on Modbus / RTU. as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Air Handling Unit - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Treated Fresh Air Unit - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Ventillation Fans - Smoke Exhuast , Evacuation Fans, Jet Fans as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Electrical System - as per technical specification etc. as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Plumbing System - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Water Tanks - as per IO Summary and as per technical specification etc. as required.
Supply, Developing, Testing, Commissioning of IP based 32 bit dual core microprocessor, minimum 100 MB RAM & 60 MB flash memory, true peer to peer communication,DDC to support NTP synchronization,DDC should be modular & expandable in steps for future expansion requirements, DDC with 230 VAC +_ 10 % powered will be preferrable , DDC shall have inbuilt web browser and support XML, along with DDC Panel for Fire Fighting System - as per IO Summary and as per technical specification etc. as required.
Supply, installation, testing and commissioning of hand held portable operator terminals.(POT) touch screen type, shall be able to view graphs , alarms , parameters etc These shall be required if the Controllers and Integration Units do not have a built in keypad on the facia . With required connectors etc. - 4inch. as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Outdoor type Ambient Temperature with Humidity Sensor with radiation shield , IP65 rated(Temp Range -30 to +50 °C, RH : 0-100 %). as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Blower status in Air able to measure pressure at zero pascal pressure.as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Differential Pressure switches the for indicating the Filter status in Air able to measure pressure at zero pascal pressure.as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Temperature with Humidity Sensor, IP65 rated with RH accuracy 3 %, temp accuracy +_ 0.7 deg (0 to 70 Degree) as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Air Type Differential Pressure Transmitter as per technical specification etc. as required.
Supply, Installation, Testing, Commissioning of Ultrasonic type Level Transmitter (5mtr. Depth ) as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 2 Core X 1.0 Sqmm Armoured Shielded Copper Cable (per Hard & Soft I/O points to DDC). as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 4 Core X 1.0 Sqmm Armoured Shielded Copper Cable (per I/O points hard wired to DDC). as per technical specification etc. as required.
Supplying, laying , testing and commissioning of 3 Core X 1.5 Sqmm Armoured Shielded Copper Cable (per DDC to UPS Power Supply). as per technical specification etc. as required.
5.0 FFTG Works FFTG-01.00 Fire pumps & Acce, Yard Hydrant, Internal Hydrant, Hose reel & Sprinkler System Supply, Installation, Testing and Commissioning of Electric driven Pump (Hydrant & Sprinkler pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, end suction back pull out pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 80 m. head conforming to IS standards. b) Casing - CI, Imperller-Bronze, Shaft - SS 410, Mechanical seal c) Squirrel cage induction motor with suitable HP with synchronous speed 2970 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber belows, anti-vibration arrangement, cables & other accessories as required for complete Installation of pump set. e) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement.
Supply, Installation, Testing and Commissioning of Diesel Engine driven fire pump (Standby Pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, end suction back pull out pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 2280 lpm at 80 m. head conforming to IS standards. b) Casing - CI, Imperller-Bronze, Shaft - SS 410, Mechanical seal c) Diesel Engine with suitable HP with synchronous speed 2300 RPM, diesel tank, battery, exhaust pipe with insulation with all required accessories. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber belows, anti-vibration arrangement, cables & other accessories as required for complete Installation of pump set. e) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement.
Providing, Fixing, Testing and Commissioning of Electric driven pump Hydrant & Sprinkler( pressurization pump) suitable for automatic operation and consisting of following: complete in all respect as required. a) Vertical inline pump to ensure a minimum pressure of 3.5 kg / sq.cm. at highest and farthest outlet at specified flow of 180 lpm at 80 m. head conforming to IS standards. b) Casing - SS 304, Imperller-SS 304, Shaft - SS 304, Mechnical seal c) Squirrel cage induction motor with suitable HP with synchronous speed 2900 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard and other accessories as required for complete installation of pump set. e) Suitable cement concrete foundation duly plastered with anti vibration pads.
Supply, Installation, Testing and Commissioning of Electric driven Terrace Booster Pump suitable for automatic operation and consisting of following: complete in all respect as required. a) Horizontal, centrifugal, end suction back pull out pump at specified flow of 900 lpm at 40 m. head conforming to IS standards. b) Casing - CI, Imperller-Bronze, Shaft - SS 410, Mechanical seal c) Squirrel cage induction motor with suitable HP with synchronous speed 2965 RPM, Suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, Conforming to IS standards. d) Common Base plat for Pump and motor and coupling, coupling guard, rubber belows, anti-vibration arrangement, cables & other accessories as required for complete Installation of pump set. e) Suitable cement concrete foundation with cement concrete plaster complete with anti-vibration arrangement.
Supply, Installation, Testing and Commissioning of 150 mm dia. Pressure Gauge (for all pipes) of range 0 - 15 Kg / cm² Polished Stainless Steel Case with positive seal against weather, moisture & dust, with Glycerine filled, screwed, nipple, isolation valve, U-type stainless steel siphon tube and complete with necessary as required.
Supply, Installation, Testing and Commissioning of Pressure Switches for automation of fire pumps. Pressure switches shall be SPDT type suitable for single phase supply with diaphragm, IP 67 protection as required.
M.S. Above Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, Above ground M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. a) 200 mm dia. (wall thickness 6.3 mm)
b) 150 mm dia.
c) 100 mm dia.
d) 80 mm dia.
e) 65 mm dia.
f) 50 mm dia.
g) 40 mm dia.
h) 32 mm dia.
i) 25 mm dia.
M.S. Under Ground Pipe Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, Under ground M.S. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges / wrapping coating 4mm thick / 150mm width as per IS:10221 etc., and two coats of anticorrosive primer and testing after Installation etc. as per specifications complete as required. All fittings up to 50mm shall be forged and above 50mm shall be butt welded. a) 150 mm dia.
b) 100 mm dia.
c) 80 mm dia.
Supply, Installation, Testing and Commissioning of C.I. Y type Strainer with S.S. Screen/SS 304 having 1.2mm perforation with require accessories. a) 200 mm Dia.
b) 100 mm Dia.
Supply, installation, testing and commissioning of C.I. Butterfly valve (IS:13095 , PN 16) with flanges, nut bolts, gaskets complete as required. a) 150 mm dia.
b) 100 mm dia.
c) 65 mm dia.
Supply, Installation, Testing and Commissioning of C.I. Sluice valve (IS: 14846,PN 16) with flanges, nut bolts, gaskets complete as required. a) 200 mm dia.
b) 150 mm dia.
c) 80 mm dia.
d) 65 mm dia.
Supply, Installation, Testing and Commissioning of Cast iron Dual plate Check valve (PN 1.6) a) 200 mm dia.
b) 150 mm dia.
c) 100 mm dia.
d) 65 mm dia.
Supply, Installation, Testing and Commissioning of Air vessel of size 450 x 2000 mm long fabricated from 8 mm thick M.S Plate and installed vertically on suitable legs with required necessary valves and connection with required accessories.
Supply, Installation, Testing and Commissioning S.S. Fire Hydrant Single Landing Valve with 80 mm N.B. flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290. Including fixing with anchor fastener and flanged tapping complete as required.
Supply, Installation, Testing and Commissioning of Fire Hose Cabinet wall mounting type 18swg (750 mm x 600 mm x 250 mm deep) with required accessories as per specification.
Supply, installation, testing and commissioning non-percolating rubber reinforced lined Fire Hose pipe (as per IS : 636) of 63 mm dia and 1no.x15 mtrs long. The hose shall be rated for burst pressure of 38 kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) bound as per specification.
Supply, Installation, Testing and commissioning of 63 mm dia instantaneous pattern SS short branch pipe, 20 mm dia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required by the Local Fire Authority.
Supply, installation, testing and commissioning of First Aid Hose Reel (25 kg/cm²) conforming to IS:884 comprising of hose reel drum, 8 mm shut off nozzle, hose reel tubing type-3 as per IS: 444 of 25 mm dia x 30 mtr. long, painting, fixed wall type with fixing bracket, anchor fastener, bolts & nuts etc. complete as required by Local Fire Authority.
Supply, installation, testing and commissioning of forged brass Ball Valve.(PN 25) a) 25mm dia
Supply, Installation, Testing and Commissioning of 25mm Brass Sprinkler test and Drain Valve (300 PSI) assembly with all required fittings as per drawing and as directed.(UL listed & FM approved)
Providing & fixing Gun Metal fire brigade suction hose coupling (draw-out connection) with 2 nos 63 mm dia instantaneous type male couplings complete as per specification/drawings and as directed by Engineer In Charge.
Supply, installation, testing and commissioning of Cast Iron Two Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required.
Supply, installation, testing and commissioning of Cast Iron Four Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc. complete as required.
Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve with necessary fittings. Size: 25 mm (For Riser)
Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required : 150 mm dia
Supply, Installation, Testing and commissioning of Quartzoid Bulb type Sprinkler Heads. a) Pendent Sprinkler 68°C - K-80 - standard response - UL listed
b) Pendent Sprinkler with rosette plate 68°C - K-80 - standard response - UL listed
c) Upright Sprinkler 68°C - K-80 - standard response - UL listed
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. b) Size: 700mm
c) Size: 1200mm
Supply, Installation, Testing and commissioning of Vane type Flow Indicating Switch with fittings, Flanges, nut-bolts, washers etc. as per requirement. (UL listed & FM approved) a) 150 mm dia.
b) 100 mm dia.
Supply, installation, testing and commissioning of Pump on/off Remote switches to each internal hydrant valve with required accessories.
Supply, installation, testing and commissioning of XLPE insulated FRLS copper armoured Cable from each Pump on/off switches to Panel with all necessary accessories. Size: 4 core x 2.5 sq. mm
Providing and laying Brick Masonary Valve Chamber of inside dimension 1.0M x 1.0M x 1.2M deep with 9" thick wall 20mm thick plastered from inside and 6mm thick MS cover with handle. Top cover to be painted with Red oxide primer and shall be capable of with stand 20 tone load.
Supply, installation, testing and commissioning of Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg confirm to IS:15683, stored pressure, squeeze type with ISI marked fitted with required accessories including wall suspension brackets.
Supply, installation, testing and commissioning of ABC (MAP 90%) type 6 kg stored pressure, squeeze type confirm to IS:15683, with ISI marked fitted with required accessories including wall suspension brackets.
Supply and fixing of ISI mark (IS:15683) Clean Agent HCF236fa, 10 Kg modular type ceiling mounted Fire extinguisher , Stored pressure type with pressure guage.
Providing, fixing AUTO GLOW photo luminescent Signage's as per IS standard in Block / Small Letters on rigid sheet with necessary wall or Ceiling fittings as Specified Sizes: a) Fire lift: size: 100 X 300mm
b) In case of Fire, do not use lift, use staircase: 200 X 200mm
c) Fire Equipment : size: 100 X 300mm
Supply Of Self Contained Rechargeable SWGS Emergency Egress Routes Lighting With the 1X 3 W LED Lamp. The equipment Shall Surface/hanging mounted with all require Accessories with requirement for the Fire and Safety code of practice with 3 Hours backup. Nominal Input Voltage 230 +-10 % to 240V A.C. +-10 % 50 Hz +-10 % as specified in specification. (Size:300 x 180mm)
Getting Approval/NOC of Fire protection system (Hydrant, Sprinkler etc..) from local fire authority and any other relevant statutory authority at initial and various other stages of work, including preparation of report/drawings as per fire authority.
HVAC : Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) 18 HP
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) 16 HP
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) 14 HP
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), microprocessor based Controller, top discharge type condensing unit(s), with R410 A Refrigerant (Or Eco Friendly Green Gas if any), vibration isolators, with suitable foundation, MS Stand for Unit with necessary paint etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5. (Design should be got approval before execution from engineer in charge) 12 HP
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System 1.2 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System 1.6 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity 4-way/2 way/radial flow as per approval VRV Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, max noise level 60dB @ 400 cfm per TR(minimum) complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature fresh air provision compatible for Remote Operation System 1.6 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0.8 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1.3 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 1.65 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity VRV High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with noise level maximum 60 dB @min 400 cfm /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.0 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. Low static ductable units (minimum 25 pascal external static pressure). 1.6 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. High Static Ductable units (minimum 110 pascal external static pressure) 5.5 TR
INDOOR UNIT Supply, installation, testing and commissioning of following minimum capacity and external static pressure VRV ceiling mounted ductable type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, corded remote control, outer cabinet, vibration isolators, drain pan, other necessary supports etc., suitable for operation on single phase AC supply 230 V ± 10%, 50 Hz complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. High Static Ductable units (minimum 110 pascal external static pressure) 8.0 TR
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-0 tubular insulation/with Class-0 closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc with necessary refrigerant joint as required : 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm with 19 mm thick insulation
Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments. 2C X 1.5 Sq mm Shielded Armoured
Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments. 3C X 1.5 Sq mm Shielded Armoured
Supply installation testing commissioning Shielded Shielded Control Cables for VRV System with necessary ISI mark Medium class rigid PVC pipes with necessary accessories with termination in machine and control equipments. 4C X 1.5 Sq mm Shielded Armoured
Central Control System Cord type remote control with thermostat, LED Display and internal wiring for Cassette, FCU & CSU
Central Control System Central wired Remote Control System
Double Skinned Floor / Loft Mounted Exhaust Air Units. Supply, installation, testing and commissioning of cabinet type Double skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection at suction side & exhuast ducting along with suction & descharge side dampers; ready to start unit with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. Discharge side to have GI Exhaust cowl and SS birdscreen. The unit shall be supplied with Starter Panel of required motor capacity. 8500 CFM / 50mm Static Pressure for Pump Room
Double Skinned Floor / Loft Mounted Exhaust Air Units. Supply, installation, testing and commissioning of cabinet type Double skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection at suction side & exhuast ducting along with suction & descharge side dampers; ready to start unit with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. Discharge side to have GI Exhaust cowl and SS birdscreen. The unit shall be supplied with Starter Panel of required motor capacity. 10800 CFM / 50mm Static Pressure for Toilet
Double Skinned Floor / Loft Mounted Exhaust Air Units. Supply, installation, testing and commissioning of cabinet type Double skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection at suction side & exhuast ducting along with suction & descharge side dampers; ready to start unit with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. Discharge side to have GI Exhaust cowl and SS birdscreen. The unit shall be supplied with Starter Panel of required motor capacity. 2000 CFM / 50mm Static Pressure for Lab
Double Skinned Floor / Loft Mounted Exhaust Air Units. Supply, installation, testing and commissioning of cabinet type Double skinned Centrifugal Exhuast Air Unit; unit shall have leakproof canvass connection at suction side & exhuast ducting along with suction & descharge side dampers; ready to start unit with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. Discharge side to have GI Exhaust cowl and SS birdscreen. The unit shall be supplied with Starter Panel of required motor capacity. 2500 CFM / 50mm Static Pressure for Dissection Hall
Double Skinned Floor / Loft Mounted Fresh Air Units. Supply, installation, testing and commissioning of cabinet type Double skinned Centrifugal Fresh Air Unit; unit shall have leakproof canvass connection at descharge side along with damper & filter at suction side along with plenum; ready to start unit hooked upwith 4P TEFC with IP 55 protection motor with pully / belt drive arrangement on adjustable frame; fan motor assembly mounted on corrossion proof-painted MS baseframe; baseframe to rest on vibration isolation pads. The unit shall be supplied with Starter Panel of required motor capacity. 8000 CFM / 50mm Static Pressure for Basement
Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly.Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. 12000 CFM / 15mm Static Pressure for Lift Well Pressurisation
Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly.Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. 10000 CFM / 15mm Static Pressure for Lift Well Pressurisation
Supply, installation, testing and commissioning of Tube Axial fans complete with Hot dipped Galvanised Steel Casing, adjustable pitch die cast aluminium impeller (Hub and blades), motors & spun flanges on both ends. Casing position shall be as per the job requirement and shall be marked on the fan assembly.Fan inlet & outlet side fire rated canvass connections & non return dampers to be required. All other fan Floor mounting accesories will be provide with the fan. Electrical Starter Panel supplied with matching rating for SA Fan motor, required DC Supply for control Valve, including short circuit / overload MCB protection, Motor Status On / Off / Trip, command, Automanual Status, fire status controlling, contacts for remote operation through Operating Panels, BAS compatiibility; Starter panel shall be minimum 14G MS powder coated with ventilation fan, inside light and duly internally wired and tested. 17000 CFM / 15mm Static Pressure For Staircase Pressurisation
HVAC 3.0: DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Thickness 0.80 mm sheet
Thickness 1.00 mm sheet
Thickness 1.25 mm sheet
Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications.
Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers complete as per specifications and size & shape as per site requirement and approved design.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as per specifications and size & shape as per site requirement and approved design.
Supplying, fixing testing commissioning of supply air diffuser of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core and size & shape as per site requirement and approved design.
Supplying, fixing testing commissioning of Return air diffuser of powder coated aluminium without volume control dampers with anti smudge ring & removable core and size & shape as per site requirement and approved design.
Supply, installation, testing & commissioning of thermal insulated flexible duct of following sizes duly supported at regular interval as per site requirement etc. complete as required as per specifications. (A) 200 mm dia.
Supplying, Fixing, testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire Damper
Actuator
Supplying, fixing Duct Acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommanded thickness of 15 mm. It shall be fixed inside of the duct with the help of adhesive complete as per specifications and as required. 15mm
Supplying, fixing AHU Room Acoustic Insulation of open cell nitrile rubber sheet having density of 180-220 kg/m3 and recommanded thickness of 20 mm. It shall be fixed inside of the surface with the help of adhesive complete as per specifications and as required. 20mm
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile rubber (Class "O") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 25mm
Supplying and fixing Duct thermal insulation (which is outside the building/exposed to atmosphere) - with Closed cell elastomeric foam made from Nitrile with company bonded GC sheet having density of 40-60 Kg/m3. Insulation thickness of 25 mm for Supply air duct. complete as per specifications and as required. 25mm
Supplying & fixing 50mm thick TF quality expanded polystyrene for underdeck insulation on slab / wall / shaft exposed to sun / atmosphere as per specifications.
Supply & Fixing False Ceiling Insulation Encapsulated having Density of 48 Kg/m3 and thickness of 50 mm encapsulated in black thermo-acoustic cloth, three side machine stitched and one end closed with hook and loop fastners. complete as per specifications and as required. 50mm
HVAC 4.0: Miscelleneous Works Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 50 mm dia.
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 40 mm dia.
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 32mm dia.
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 25 mm dia.
Rigid UPVC drain pipe of 10 Kg/cm2. rating with 9 mm thick.nitrile rubber insulation. 19 mm dia.
Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting. (1)For 3 Star Rating of current year (A) for 0.8 to 1.0 ton capacity
Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting. (1)For 3 Star Rating of current year (B) for 1.5 ton capacity
Providing and erecting Inverter based approved make split air-conditioning unit consisting of condensing unit with variable speed fan motor, inverter type hermetically sealed rotary compressor with accessories etc. duly connected separately erected evaporating unit and blower motor with its accessories by means of extra supplied proper insulated copper tubing,drain PVC pipes suitable for ( cost includes Eco Friendly green gas charging and 15A plug top & Remote Control & MS Stand) with necessary core cutting. (1)For 3 Star Rating of current year (C) for 1.7 to 2 ton capacity
SUB HEAD 'I' - OPERATION & MAINTENANCE SYSTEM OPERATION & MAINTENACE : Bidder shall indicate their charges for the following : Comprehensive preventive maintenance contract for the entire chilled water system supplied / Installed by the HVAC contractor inclusive of all parts, consumables and labour for all equipment supplied as well as replacement of any equipment / component / part which can not be repaired to the satisfaction of the Client. The Operation contract shall also include operatrion of entire chilled water System & VRV System based on 2 persons for 2 shifts & 1 person for night shift and 365 days per year. Only operation cost shall be considered during defect liability period. 1st year Cost of maintenance shall be inclusive in the DLP and no extra payment will be paid for the maintenance in the first year after handing over. Only Opearation Cost During DLP
1st Year after DLP
2nd Year after DLP
3rd Year after DLP
4th Year after DLP
5th Year after DLP
KITCHEN FOR STUDENT HOSTEL Store Area - SS 4 Shelf Storage rack Size - 1100x550x1650
Store Area - Wall mounted storage rack Size - 1500x300x250
Store Area - SS Storage bins on wheels, caps- 100 kg
Store Area - Potato bin - 600x600x1200
Wet Grinder AREA - Potato peeler - caps-10 kg
Wet Grinder AREA - Tilting type Masala Grinder caps-10 Ltrs.
Wet Grinder AREA - Pulveriser - caps-2 hp
Wet Grinder AREA - Dough Kneader caps-10 kg
Wet Grinder AREA - Four door refrigerator - caps-1000 ltrs
Wet Grinder AREA - Two Door Vertical freezer - caps-1000 ltrs
Veg cutting chopping Area - Work table with sink splash back & u/s, Size - 1500x600x850+150
Veg cutting chopping Area - Work table with u/s and splash back, Size - 1500x600x850+150
Veg cutting chopping Area - Veg cutting chopping m/c - caps- 110kg/hr
Cooking Area - Side table with u/s, Size - 600x600x850
Cooking Area - Kadhai Fryer, Size - 600x600x850
Cooking Area - Chapatti plate puffer, Size - 1200x600x850
Cooking Area - Marble top chapati rolling table with u/s, Size - 1800x600x850
Cooking Area - Two burner Indian cooking range with u/s, Size - 1350x600x850
Cooking Area - Single burner Indian cooking range with u/s, Size - 600x600x850
Cooking Area - Tilting type bratt pan, caps- 100 ltrs
Cooking Area - Tilting type boiling pan, caps- 100 ltrs
Cooking Area - Side table with u/s, Size - 600x600x850
Cooking Area - Idlii steamer, caps- 180 idlii
Cooking Area - Pick-up table with u/s, 1500x750x850
Service AREA - Thali Counter with 1 ambient 1/1 GN Pan and service rail & U/s (Three side covering) - Size - 1100x650+300x850
Service AREA - BAIN Marie with 4 No. hot 1/1 GN pans and 1 No ambient GN Pans with service rail and u/s (Three side covering) Size - 1800x650+300x850
Service AREA - Ice cream freezer, make- cellfrost
Service AREA - Visi Cooler, make- cellfrost
Service AREA - SS 4 shelf perforated glass & jug rack, size - 1100x550x1650
Service AREA - Water cooler, caps- 100 ltrs
Pot wash & Dish wash area - SS Pot rack, size - 1100x600x1650
Pot wash & Dish wash area - Pot wash sink unit, size - 900x900x850+150
Pot wash & Dish wash area - Soiled dish table having 75mm deep top with garbage chute, size - 1200x750x850
Pot wash & Dish wash area - Two sink pre wash unit with pre rinse shower, size - 1650x750x900
Pot wash & Dish wash area - Hood type dishwasher machine, caps- 80 raack/Hr
Pot wash & Dish wash area - Clean dish landing table, Size - 1200x750x900
Pot wash & Dish wash area - SS 4 shelf perforated clean dish rack, size - 1100x550x1650
Kitchen Drain box - SS angle with perforated bascket & pipe grating, size - 1200x300x100
Kitchen Drain box - SS angle with perforated bascket & pipe grating, size - 600x750x100
Exhaust hood with baffle filter & fresh air & LED Lights, size - 1950x1100x500
Exhaust hood with baffle filter & fresh air & LED Lights, size - 1600x1100x500
Exhaust hood with baffle filter & fresh air & LED Lights, Size -1300x1100x500
Exhaust hood with baffle filter & fresh air & LED Lights, size - 2400x1100x500
Exhaust hood with baffle filter, size - 600x750x500
GI duct for exhaust system, 800 r.sq.ft
exhaust blower, cap: 10000cfm
fresh air ducting, 600 r.sq.ft
fresh air intake blower with filter box having 15micron filter, cap: 6000 cfm
Gas Line from 1/2" C-Class pipe with pressure regulator and other fittimgs like burner pigtails, N.C Valve with 3/3 Gas bank
Supply, Installation, Testing & Commissioning of MANI FOLD - 5X2
Supply, Installation, Testing & Commissioning of MS BRAKET WITH STAND
Supply, Installation, Testing & Commissioning of MF BALL VALVE
Supply, Installation, Testing & Commissioning of N.R.V
Supply, Installation, Testing & Commissioning of C.P.T. - 2FEET
Supply, Installation, Testing & Commissioning of ADEPTOR
Supply, Installation, Testing & Commissioning of PRE-SET REGULATOR
Supply, Installation, Testing & Commissioning of D.B.C
Supply, Installation, Testing & Commissioning of MAIN LINE BALL VALVE
Supply, Installation, Testing & Commissioning of BRASS UNION
Supply, Installation, Testing & Commissioning of 1/2 X 3/8 N.C.V
Supply, Installation, Testing & Commissioning of B.P.T 4FT
Supply, Installation, Testing & Commissioning of MS BRACKET
Supply, Installation, Testing & Commissioning of 1/2 MS C CLASS PIPE
Supply, Installation, Testing & Commissioning of FRESH AIR HANDLING UNIT - 3HP WET SCRUBBER FOUNTAIN WATER SUPPLY WITH TANK DOUBLE SKIN BODY WITH PUFF INSULATION V TYPE BELT DRIVE WITH FORWARD CURVE FAN. ~ 1 YEAR WARRANTY ON MOTOR
Supply, Installation, Testing & Commissioning of CENTRIFUGAL EXHAUST BLOWER WITH PUFF INSULATION KRUGER MAKE FAN WITH HIGH EFFICENT MOTOR KRUGER MAKE FAN WITH HIGH EFFICENT MOTOR 1 YEAR WARRANTY ON MOTOR
Cylinder mounting bracket
High Pressure Gas Manifold for 2 cylinder with High pressure Manifold Block, and manifold support frame
High pressure SS braided flexible hose, 1 meter long
Check Valve, 1/4" M/F
Cylinder click on Adopter
High Pressure High Flow Single Stage Cylinder Regulator with inlet and outlet pressure gauge, Inlet Pressure: 0-40 Bar , Outlet Pressure : 5 bar
Non Return Valve 1" OD
Ball Valve, 1" OD
Tee, 1" OD
Elbow 1" OD
Union 1" OD
Reducing Tee, 1"x1/2"x1" OD
Reducer 1" x 1/2" OD
Tube, 1" OD Seamless, thickness 1.6mm
PP Clamp
Alluminium Profile, Powder coated
10 MM Hitec threaded road, 1 meter long with all required accessories loke, Hilti Anchor fastners, Washers, Nuts, bolts, etc.
Tagging
High Pressure High Flow Flash back Arrestor inlet / outlet size 1"
Connector for Flash Back Arrestor
Miscelleneous fittings & Hardware for Gas Bank
YASHNAND ENGINEERS AND CONTRACTORS PVT. LTD.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid