Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.8 LAccepted-Finance UDHAMPUR | 1 | Accepted-Finance qualified | |
| 2 | 2₹12.0 L+₹19,210 (1.63%)Accepted-Finance | 2 | Accepted-Finance qualified | |
| 3 | 3₹12.6 L+₹78,130 (6.62%)Accepted-Finance JAMMU AND KASHMIR JAMMU AND KASHMIR | JAMMU | JAMMU AND KASHMIR | 181122 | 3 | Accepted-Finance qualified |
Tender Value
Refer Docs
EMD Value
₹26,000
Closing Date
2 Apr 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Creation of 250kva substation
2022_PDD_160352_1
ED/UDH/69 of 2021-22 dt. 12-02-2022
Open Tender
Electrical Works
Turn-key
45 days
Ramleela Ground Malhar Morh Garhi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division JPDCL
₹26,000
5 Jul 2022
12 Feb 2022
4 Apr 2022
12 Feb 2022
2 Apr 2022
12 Feb 2022
12 Feb 2022 - 19 Feb 2022
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning of 11kv Line on 9 mtr long ST poles at Ramleela Ground Malhar Morh Garhi Udhampur.
9 mtr. Long PCC Pole (PCC-WL-300KG)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Stone Pad (300mmX300mmX75mm)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for creation of Creation of 250 KVA Sub Station a Ramleela Ground Malhar Morh Garhi Udhampur.
11/0.433kV, 3-phase 250 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Copper Wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
240 mm² Double Core Cable,1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
LT distribution box for 250 KVA DTR with MCCB for incomer and SfU's for outgoing circuits.
Cement bottoming of ST poles in 1:2:4 mix as per REC standards 0.5 cum per pole
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of 25mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Painting of sub station ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Danger Plates with Clamps
Anti climbing GI Barbed wire
Prodigy meter
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 3 phase 4 wire LT line on 8 mtr long PCC pole at Ramleela Ground Malhar Morh Garhi Udhampur.
8 mtr. Long PCC Pole (PCC-WL-200KG)
GI U-Clamp for shackle insulator
0.03 ACSR Conductor Weasel.
Shackle Insulators
Galvinized Nuts and Bolts.
Danger Plates with Clamps
Anti- Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Stone Pad (300mmX300mmX75mm)
LT line spacers
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
AJAY KAPOOR
SUNIL KUMAR SURI CONTRACTOR
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .