Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.4 LAccepted-AOC | L-1 | Accepted-AOC Lowest rate quoted by Firm | |
| 2 | L-2₹6.6 L+₹15,500 (2.40%)Rejected-Finance | L-2 | Rejected-Finance The rate quoted by the firm is second lowest evaluated for subject work. | |
| 3 | Rejected-Technical 6 KAMMAVAR STREET MITTANAMALLEE IAF AVADI TIRUVALLUR TAMIL NADU 600055 | THIRUVALLUR | TAMIL NADU | 600055 | - | Rejected-Technical The Firm not fulfill all the parameters |
Tender Value
Refer Docs
EMD Value
₹13,500
Closing Date
31 Jan 2024, 1:30 pmClosed
DIG(Medical)
Office of the DIG(Medical) Composite Hospital,
Repair and maintenance of Electrical items of Composite Hospital Avadi CRPF
2024_CRPF_791939_1
B.V.1/2023-24-CH-Works
Open Tender
Electrical Works
Works
45 days
Office of the DIG(Medical) Composite Hospital
Please refer Tender documents.
2 documents required · 2 mandatory
₹1
Yes
The DIG(Medical)/MS Composite Hospital, CRPF Ava
₹13,500
2 Mar 2024
24 Jan 2024
1 Feb 2024
24 Jan 2024
31 Jan 2024
24 Jan 2024
24 Jan 2024 - 31 Jan 2024
Repair and maintenance of Electrical items of Composite Hospital Avadi CRPF at Group Centre Avadi Chennai-65
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 60 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. :: 63 AMP
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 A socket outlet
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Double pol
Supplying and fixing brass batten/ angle holder including connection etc. as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing following rating, three pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 AMP
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 AMP
Supplying and fixing following rating Wall mounted Fan complete connections as required.
Supply and fixing of 20 watt surface /wall mounted white power coated CRCA housing 4 feet LED Batten along with 1 No. LED tube IP 20 with polycarbonate opel diffuser lumens efficiency=100 lu/per watt or above lumens with 5200 k to 6500 k,Guarantee > 5 year complete with testing and commissioning etc.as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, four core cable in surface/ recessed medium class PVC conduit as required. 35 sq. mm cable Earth wire
B MURUGESAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .