Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.9 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹57.7 L+₹2.8 L (5.16%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹58.6 L+₹3.7 L (6.77%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹68.0 L+₹13.1 L (23.9%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹71.6 L+₹16.7 L (30.5%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹87 L
EMD Value
₹1.6 L
Closing Date
16 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE 138 WE
HQ 138 WE C/o 56 APO
Repair replacement of bldg earthing equipment earthing and lightening conductors and connected accessories and repair replacement re-routing of external electric supply including repair to Lt over head conductors and other allied works under GE 865
2021_MES_481355_1
138WE/L-73/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per Tender Doucements
8 documents required · 8 mandatory
₹1,000
Yes
GE 865 EWS
₹1.6 L
Yes
10 Dec 2021
12 Oct 2021
23 Nov 2021
12 Oct 2021
16 Nov 2021
2 Nov 2021
60 days
Amount
Material and labour for checking/ testing of resistance value of any type of earth pits by disconnecting earth continuity conductor from test terminal block/panel/equipment at various location of building earthing/equipment earhings falling under AOR of GE 865 EWS and reconnecting the earth continuity conductor after testing. Earth tester will be provided by contractor. Earth tester must be calibrated. Contractor has to prepare record of test of earthings indicating the locations in surrounding of bldgs and give the earthing No, type of earthings i.e. earthing for E/M equipments (WQ1, EQ2 etc), lightening protection earthing (LA1, LA2 etc) & Bldg earthing (BA1, BA2 etc). Earth test results shall be recorded in reference to Earth Nos provided for the instln. Earth test to be signed by rep of contractor, rep of MES and rep of user. Test reports to be submitted in duplicate complete all as specified and directed.
Material and labour for supply, installation, testing and commissioning of GI pipe electrode earthing based on 6 mtr long GI pipe 80mm dia (ID) medium grade, GI strip 32x6mm (Strip in pipe type electrode) and GI pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 Kgs approx of BFC shall be filled around the GI pipe electrode. Rate included for testing, commissioning including checking of earth continuity and earth result complete all as specified and directed. Vendors are bound to get earthing results less than or upto 5 Ohm with or without grid of earthings (Maximum number of new earthings in grid are restricted to 3 Nos) GI strip required for interconnection of earth pits in grid must be laid 2 ft below the ground level and the same must be treated with chemical (BFC) if required to achieve resistance value. Any additional work and material required to achieve the required result is inclued in the cost. Rate is included for boring of earthing in any type of soil/rock upto 200mm wide bore . Note :- (i) Earth strip from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately. (ii) Maximum No of New earthings to be connected in grid are restricted to 03 Nos
Material and labour for supply, installation, testing and commissioning of chemical earthing pure copper electrode 76mm x 6 mtr long, grade, copper strip 32x6mm (Strip in pipe type electrode) and pure copper pipe electrode shall be filled with MFC for improvement of conductivity of electrode, 120 Kgs approx of BFC shall be filled around the GI pipe electrode. Rate include for testing, commissioning including checking of earth continuity and earth result complete all as specified and directed. Vendors are bound to get earthing result less than or upto 2 Ohm with or without grid of earthings (Maximum number of new earthings in grid are restricted to 3 Nos) copper strip required for interconnection of earth pits in grid must be laid 2 ft below the ground level and the same must be treated with chemical (BFC) if required to achive resistance value. Any additional work and material required to achive the required result is included in the cost. Rate is included for boring of earthing in any type of soil/rock upto 200mm bore. Continuity of good earth resistance shall maintained upto 1 year and testing will be carried out quarterly by MES authority. Copper strip must be connected with copper pipe electrode and other joints through nut bolt in addition to welding complete all as specified and directed. Note :- (i) Earth strip from top connector of electrode to test point and further connection to LT panel/AF equipments/ for grid of earthing shall be measured and paid separately. (ii) Maximum No of New earthings to be connected in grid are restricted to 03 Nos
M&L for providing earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6mm as earthing lead buried directly in ground verically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32x6mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point, providing charcoal and common salt all as shown in electrical plate No 3 of SSR Part-I of 2009 & as specified or indicated and testing on completion incuding exaction/ earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced) with welded steel wire fabric (XPM) weight not less than 4 Kg/Sqm), funnel with wire mesh, watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32 x 6mm, 7.5 meter long, etc complete all as specified and directed. Note :- (i) Vendors are bound to get earthing result less than or upto 5 Ohm for lightning arrester earthings and less than or upto 2 Ohm for signal and power supply earthing with or without grid of earthing (Maximum number or new earthings in grid are restricted to 3 Nos). Any additional work and material required to achive the required result is included in the cost quoted by the tenderer. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate).
M&L for providing earthing complete with copper earth plate electrode 600mm x 600mmx 3.15mm thick buried directly in ground earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper earth strip 20 x 3mm by means of bolts, nuts, checknuts & washers of copper and connecting to test point, providing charcoal and common salt, all as shown in electrical plate No 3 of SSR Part-I of 2009 & as specified or indicated and testing on completion including excavation/ earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg /Sqm), funnel with wire mesh, watering pipe of 20mm bore medium grade and lugs, includig copper earth strip 20x3 mm, 7.5 meter long, etc complete all as specified and directed. Note :- (i) Vendors are bound to get earthing result less than or upto 5 Ohm for lightning arrester earthings and less than or upto 2 Ohm for signal and power supply earthing with or without grid of earthing (Maximum number or new earthings in grid are restricted to 3 Nos). Any additional work and material required to achive the required result is included in the cost quoted by the tenderer. (ii) Excavated material to be removed from the site and deposit at the distance not exceeding 50m distance and levelled. (iii) Refill the pit with black cotton soil. (M&L for black cotton soil must be included in the quoted rate).
S&F in replacement of test point made out of gun metal or phosphorous bronze of size 75 x 50x 5mm duly mounted on epoxy insulator 02 Nos. Drilling of upper & lower portion of test point for incoming & outgoing connections with brass nut bolt to be fitted in and including terminal blockmade out of MS sheet 2mm thick as per the sample duly painted with two coat of enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for fixing earth indicators made out of 3mm thick MS sheet of size 200mm x 300mm duly fixed in MS angle iron 25mm x 25mm x 3mm of 600mm long fixed to ground by means and including necessary cement concrete foundation and painting with one coat of synthetic enamel paint over a coat of red oxide primer complete for writing earth reading and connected plant/panel etc and excavation and earth work complete all as specified and directed.
Taking down carefully from roof/ wall of the building loose/ hanging/ deshaped/ GI strip/ aluminium strip/ copper strips of any size & type including unserviceable insulators etc complete all as specified and directed.
S&F GI earth continuity conductor or main earthing lead of size 32x6 mm fixed to wall on battern or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for earthing etc as required complete all as specified and directed.
S&F copper earth continuity conductor or main earthing lead of size 20x3 mm fixed to wall on batten or recess or chases or buried in ground or drawn in couduit/ pipe or fixed to poles or any other indicated situation for earthing etc as required complete all as specified and directed.
S&F GI wire 4mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for earthing etc as required complete all as specified and directed.
Supply & fix aluminium strips 25x3 mm on porceline insulator T type not more than 50 cm apart complete all as specified and directed. Note :- M&L porcelain insulators with nuts bolts and screws wiil measured and paid separately
Taking down termination rod complete all as specified and directed.
Supply and fix air termination single pointed aluminium 12mm dia & 300 mm long including nuts & bolts for fixing air termination rod to pole/pipe duly insulated by providing appropriate insulator all as required at site complete all as specified and directed.
Refixing air termination rod complete all as specified and directed.
Refixing serviceable aluminium strips of any size and fixing on porecelin insulators 'T' type placed not more than 50cm apart & fixed with screws & nut bolts complete all as speciried and directed. Note :- M&L Porecelain insulators with nuts bolts and screws will measured and paid separately.
S&F GI Sheet funnel with wire mesh complete all as specified and directed.
Refixing of GI supporting pipe 40/50mm (for termination rod) complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as mass concrete for foundation of GI tubing/ Air termination rod complete all as specified and directed.
S&F GI socket reducer 40x25 mm and aluminium gutka externally threaded suitable for 25mm GI socket and internally threaded suitable for fixing epoxy insulator for fixing terminal rod complete all as specified and directed. Note :- Material and labour for epoxy insulator is included in the rate quoted by the tenderer.
S&F in replacement of porcelian insulators with nut bolts/ screws for fixing of copper/ aluminium strips/ GI strips on wall etc complete all as specified and directed.
Refixing of porcelian insulators with nut bolts/ screws for fixing of copper/ aluminium strips/ GI strips on walls etc complete all as specified and directed.
S&F GI pipe medium grade 40mm dia embeded in concrete complete all as specified and directed. (mounting arrangement for air termination) Note :- M&L for PCC work will be measured and paid separately.
S&F in repair of GI tubing 15mm bore medium grade including all necessary fittings i.e. socket, elbow etc laid on floor or fixed to wall complete all as specified and directed.
S&F in repair of GI tubing 15mm bore medium grade including all necessary fittings i.e. socket, elbow etc laid in trenches complete all as specified and directed.
S&F Stop valve of 15mm dia complete all as specified and directed.
Supply and fix Bib tap 15mm bore size of cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified
M&L for cutting the existing GI pipe upto 50mm for tapping of 15mm branch including required fittings complete all as specified and as directed.
M&L for earthing chamber of size 150x450x300 mm depth outside & 250x250x300 mm depth of PCC (1:3:6) type C1 complete all as specified and directed.
S&F in repair of earthing pit cover 50mm thick precast slab of RCC 1:2:4 type B1, reinforeced with welded steel wire fabric (XPM) weight not less than 4 Kg/Sqm incl 6mm dia bar handle complete all as specified and directed.
M&L for excavation and earthwork for reconditioning of existing earth with border line result tying between 6 Ohms to 15 Ohms for further improvement of resistance value and re-testing the test value of the treated earth and re construction of PCC pit cover with cast iron frame work, pit cover complete all as specified and directed by Engr-in-Charge. Note : The quantity of charcoal, salt and magnesium sulphate required for reconditioning of earth will be measured and paid separately under relevant item.
Supply and filling of common salt for earthing complete all as specified and directed.
Supply and filling of magnesium sulphate for earthing complete all as specified and directed.
Supply and filling of charcoal for earthing complete all as specified and directed.
Taking down Old U/S cable of any size all as specified and directed.
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 500 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 240 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 185 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 150 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 120 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 95 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 70 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 1100 volts grade of size 50 Sqmm 3.5 core laid in trenches or passing through pipes ducts or fixed to walls/ poles complete all as specified (Earth work for cable protection and sand cushioning shall be measured and paid for separtely).
All as per Srl item No 43 above but of size 35 Sqmm, 3.5 core all as specified.
All as per Srl item No 43 above but of size 25 Sqmm, 3.5 core all as specified.
All as per Srl item No 43 above but of size 16 Sqmm, 2 core all as specified.
All as per Srl item No 43 above but of size 10 Sqmm, 2 core all as specified.
Supply and laying in replacement of XLPE insulated, armoured, heavy duty electric cables (heavy duty) with stranded aluminium conductor rating 11000 volts grade of size 95 Sqmm 3.0 core laid in trenches or passing through pipes ducts or fixed to walls/poles complete all as specified. (Earth work for cable protection and sand cushioning shall be measured and paid for separtely)
M&L for excavation in trenches, n exc 1.5m wide and n exc 1.5 m in depth for foundation etc. or for laying UG cable in trenches on plan and n exc 1.5m in depth in any type of soil and getting out all as specified and directed by Engr-in-charge.
M&L for returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc 25cm, complete all as specified.
M&L for Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified and directed.
M&L for Sand cushioning to underground cables 8 cm below the cable before laying & 15cm above the cable after laying, complete all as specified in clause 19.75 of SSR Part-I, complete all as specified. Note : Punned thickness of 18 CM shall be measured and paid for.
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 size 250mm x 150mm x 40mm complete all as specified and directed.
Supply and laying of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-1 size 300mm x 180mm x 40mm complete all as specified and directed.
Taking down old change over cubicle panel all as specified and directed.
M&L in replacment for incoming on load changover switch enclosure with 250A incoming change over switch (Front Handle) to accommodate all connected accessories Havells cat part No : IHCNFE0250 or equivalent of L&T and standard or any other equivalent make approved by GE.
M&L in replacment for incoming on load changover switch enclosure with 400A incoming change over switch (Front Handle) to accommodate all connected accessories Havells cat part No : IHCNFE0400 or equivalent of L&T and standard or any other equivalent make approved by GE.
M&L in replacment for incoming on load changover switch enclosure with 630A incoming change over switch (Front Handle) to accommodate all connected accessories Havells cat part No : IHCNFE0630 or equivalent of L&T and standard or any other equivalent make approved by GE.
Taking down Old U/S change over switch of any type/ bus bar chamber all as specified and directed.
Supply and fixing in replacement of on load change over (side handle) 100 Amp, 4 pole 415V fixing on wall/frame to accommodate in sheet enclosure necessary electric connection complete all as specified and directed.
Supply and fixing in replacement of on load change over (side handle) 200 Amp, 4 pole 415V fixing on wall/frame to accommodate in sheet enclosure necessary electric connection complete all as specified and directed.
Supply and fixing in replacement of on load change over (side handle) 320 Amp, 4 pole 415V fixing on wall/frame to accommodate in sheet enclosure necessary electric connection complete all as specified and directed.
Supply and fixing in replacement of on load change over (side handle) 400 Amp, 4 pole 415V fixing on wall/frame to accommodate in sheet enclosure necessary electric connection complete all as specified and directed.
Supply and fixing in replacement of on load change over (side handle) 630 Amp, 4 pole 415V fixing on wall/frame to accommodate in sheet enclosure necessary electric connection complete all as specified and directed.
Supply and fixing in replacement of bus bar chamber size 600x450x300mm outdoor type made out of MS sheet 2.0 mm thick mounted on angle iron frame duly painted with two coat of sythetic enemelled paint over a coat of primer and comprising of thre phase aluminium bus bar 200 Amps mounted on insulators including provisioning of foundation all as specified and directed.
Taking down Old U/S GOD all as specified and directed
Supply and fixing in replacement of lightening arresters expulsion type complete with all fittings, 30 kilo Amp discharge capacity, distribution class Make - AREVA/ ALSTHOM suitable for 11 KV HT over head network including necessary connections with HT over head lines complete all as specified and directed.
Taking down Old U/S MCCB of any type all as specified and directed.
Supply and fixing in replacement of L Frame : Adjustable Termal & fixed magnetic setting MCCB 630 Amps, 50 KA, 415 Volts four pole lcs = 100% of ICU, complete all as specified and directed.
Supply and fixing in replacement of L Frame : Adjustable Termal & fixed magnetic setting MCCB 400 Amps, 36 KA, 415 Volts four pole lcs = 100% of ICU, complete all as specified and directed
Supply and fixing in replacement of L Frame : Adjustable Termal & fixed magnetic setting MCCB 250 Amps, 36 KA, 415 Volts four pole lcs = 100% of ICU, complete all as specified and directed
M&L for fixing in replacement of cable and jointing kit for 11KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 03 core XLPE armoured aluminium conductor cable of size 95 Sqmm
M&L for fixing in replacement of cable and jointing kit for 11KV (Earthed) grade cable for outdoor type termination heat shrink type joint complete with jointing material and accessories suitable for 03 core XLPE armoured aluminium conductor cable of size 95 Sqmm
Supply and fixing in replacement of air break switch gang operated (GOD) triple pole with drop out fuses mechanically operated, mounted on insulators 15 Nos & steel frame with operating mechanism & operating rod of GI pipe 25mm & medium grade with necessary clamps to be operated from ground level 11000 volts grade working pressures and current upto 200 Amps complete all as specified.
Taking down Old U/S ACSR conductor / GI wire all as specified and directed.
M&L for fixing in replacement of ACSR conductor any size drawn straight horizontal on over head lines on existing poles including binding with insulators. Weight of conductor shall be measured straight horizontal distance between centre of two adjacent poles and calculating weight of conductor of size and length by adding 3% extra for sag, jointing jumpers etc complete all as specified.
Taking down Old U/S Stay assembly all as specified and directed.
M&L for fixing in replacement of stay assembly complete with stay plate bow, stay rod of dia 16mm and gavanised iron stay wire stranded of size 7/4mm and accessories as shown in electric plate No 1 of SSR Part-I (loop type insulator, stay clamps, excavation and concrete shall be measured separtely). complete all as specified.
Taking down old U/s insulator of any type and size all as specified and directed.
M&L for fixing in replacement of shackle insulator porcelain white, brown or green 100mm height, 65mm dia for 1100 volts grade complete all as specified.
M&L for fixing in replacement of pin insulator porcelain white, brown or green 100mm height, 65mm dia for 1100 volts grade complete all as specified.
M&L for fixing in replacement of pin type porcelain white, brown or green insulator including one galvanised mild steel spindle, with nuts, bolts and washers 150mm height, 150mm dia for working pressure 11000 volts grade complete all as specified.
M&L for fixing in replacement of Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green, assembly for tension with tension clamps for conductors, working pressure 11000 volts
Taking down old U/S cross arms/channel all as specified and directed.
M&L for fixing in replacement of cross arms bracing supports clamps, back plates fabricated from steel section made out of Fe-0-310/Fe-0-410 including nuts, bolts and washers welding, drilling hole complete with two coats of aluminium paint over one coat of primer complete all as specified.
M&L for fixing in replacement of restringing/ restretching aluminium conductor/ GI wire on LT/ HT over head lines including necessary binding with binding wire with insulator, connections of incoming and out going cables complete all as specified and directed.
M&L for fixing in replacement of galvanised steel wire 4mm dia for contineous earth wire complete all as specified.
Taking down Old U/S GI tubing of any size all as specified and directed.
Supply and fixing in replacement of tubes light grade of size 80mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
Supply & Fixing in replacement of tubes light grade of size 50mm bore galvanised with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
Supply only aluminium thimble of size 10/16/35/50/70/95 Sqmm complete all as specified.
Supply only aluminium thimble of size 120/150/185/240/300/400 Sqmm complete all as specified.
M&L for painting 9 mtr steel tubular pole after scrapping and peeling of the old existing paint, corrosive patches and painting primary coat with synthetic enamelled silver paint and another final second coat to match the entire surface area of the pole and highliting the pole with 20CM wide alternate white and red radium strips upto height of 1 mtr from Ground level complete all as specified and directed by Engr-in-charge.
M&L for painting 11 Mtr steel tubular pole after scrapping and peeling of the old existing paint, corrosive patches and painting primary coat with synthetic enamelled silver paint and another final second coat to match the entire surface area of the pole and highliting the pole with 20CM wide alternate white and red radium strips upto height of 1Mtr from ground level complete all as specified and directed by Engr-in-charge.
Replacement of earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 mtrs deep below normal ground level with top edge of earth plate not less than 1.5mtrs below normal ground level connected to galvanised iron strip 32x 6mm as earthing leads by means of galvanised bolts, nuts, check nuts and washers of galvanised iron or steel complete with 20mm dia GI Pipe light grade for watering and 40mm dia GI light grade pipe for protection of strip upto test point including test point of strip 50x50x3mm GI, charcoal dust, common salt 15cm all around the earth plate all as shown in electric plate No 5 of MES SSR Part-I all as specified or indicated and testing on completion including necessary excavation, earth work PCC pit and with RCC cover of suitable size water funnel with wire mesh all as specified and directed.
All as per item No 96 above but using GI wire 4.0 mm dia as earthing leads by means of galvanised bolts, nuts, check nuts and washer of galvanised iron or steel complete with 20mm dia GI pipe light grade for watering and 40mm dia GI light grade pipe for protection of 4.0mm dia GI wire charcoal dust, common salt 15cm all around the earth plate all as shown in electric plate No 5 of MES SSR Part-I all as specified or indicated and testing on completion including necessary excavation, earth work PCC pit and with RCC cover of suitable size water funnel with wire mesh all as directed by Engr-in-charge.
Taking down Old U/S steel pole all as specified and directed.
Supply and erect steel tublar swaged poles complete with MS sheet welded on base, final taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 meters long) including painting with two coats of synthetic enamel paint (Excavation / Earthwork & PCC work will be measured & paid separately)
All as per item No 99 above but of type 410 SP 55 (11 meters long)
M&L for cement concrete in foundations of poles, type D-2 1:4:8 (40 mm graded aggregate all as specified and directed.
M&L for cement concrete in filling and massconcrete/ coping of poles type C-2 (1:3:6) (40mm graded aggregate) all as specified and directed,
M/S MALIK CHAND SIRI RAM
SUMEET TRADING CORPORATION
R B TRADERS
Rampal Singh Contractor
S S BUILDERS
EESSI
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .