Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.3 LAccepted-Finance | ₹6.3 L | 1 | Accepted-Finance Lowest bidder |
| 2 | 2₹6.8 LAccepted-Finance 1ST FLOOR SHOP NO 11 MORI GATE RAJINDER MARKET NEW DELHI DELHI 110006 INDIA | NORTH | DELHI | 110006 | ₹6.8 L | 2 | Accepted-Finance L2 bidder |
| Sl No | Description | Qty | Unit | R.V. ELECTRICAL ENTERPRISES PVT. LTD. L2 | Friends power L1 |
|---|---|---|---|---|---|
| 1.01 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(2 X 4 sq. mm + 1 X 4 sq. mm earth wire) | 200 | Mtr. | 374 ₹74,800 | 300 ₹60,000 |
| 1.02 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(3 x 4 sq. mm) | 760 | Mtr. | 261 ₹2.0 L | 180 ₹1.4 L |
| 1.03 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(2 X 10 sq. mm + 1 X 06 sq. mm earth wire) | 250 | Mtr. | 723 ₹1.8 L | 510 ₹1.3 L |
| 1.04 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (12 way , Double door) | 10 | Each | 3,019 ₹30,190 | 2,250 ₹22,500 |
| 1.05 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Single Pole) | 50 | Each | 211 ₹10,550 | 230 ₹11,500 |
| 1.06 | Supplying and fixing following rating, 2401475 volts, "C" curve, miniattlre circuit breaker suitable for lnductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(40 A to 63 A, double pole) | 10 | Each | 652 ₹6,520 | 950 ₹9,500 |
| 1.07 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (5/6 A switch) | 800 | Each | 47 ₹37,600 | 98 ₹78,400 |
| 1.08 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (3 pin 5/6 A socket outlet) | 800 | Each | 90 ₹72,000 | 110 ₹88,000 |
| 1.09 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(6 Module) | 400 | Each | 119 ₹47,600 | 170 ₹68,000 |
| 1.10 | Supplying and fixing metal/ PVC box of following sizes (nominal size) on surface or in recess including painting, etc. as required. | 30 | Each | 154 ₹4,620 | 140 ₹4,200 |
Tender Value
Refer Docs
EMD Value
₹15,434
Closing Date
27 Jan 2026, 3:00 pmClosed
The Registrar IIT Patna
3rd Floor IWD Office IIT Patna
Electrical works to provide power to several machine computer in the cubical for new CC Lab Admin Building
2026_IITP_894368_1
IITP/IWU/Elect. /NIT-08/2026
Open Tender
Electrical Works
30 days
IIT Patna
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹15,434
6 May 2026
17 Jan 2026
28 Jan 2026
17 Jan 2026
27 Jan 2026
17 Jan 2026
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(2 X 4 sq. mm + 1 X 4 sq. mm earth wire)
Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.(3 x 4 sq. mm)
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.(2 X 10 sq. mm + 1 X 06 sq. mm earth wire)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (12 way , Double door)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(Single Pole)
Supplying and fixing following rating, 2401475 volts, "C" curve, miniattlre circuit breaker suitable for lnductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.(40 A to 63 A, double pole)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (5/6 A switch)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (3 pin 5/6 A socket outlet)
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(6 Module)
Supplying and fixing metal/ PVC box of following sizes (nominal size) on surface or in recess including painting, etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections, etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (6 pin 15/16 A socket outlet)
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 13.72 MB
NIT.pdf
Tender Documents • 13.70 MB
BOQ_940059.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid