| 1 | L1₹14.5 CrAccepted-AOC 218 26 CHAKRIYA PURI SONIPAT ROAD ROHTAK 124001 | ROHTAK | ROHTAK | HARYANA | 124001 | ₹14.5 Cr Quoted ₹14.7 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹14.7 CrRejected-Finance RAM NAGAR NEW BUS STAND NARWANA 126116 | NARWANA | JIND | HARYANA | 126116 | ₹14.7 Cr | L2 | Rejected-Finance HIGHER |
| 3 | L3₹15.1 CrRejected-Finance DLG 13 14 PUSHPA COMPLEX HISAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | ₹15.1 Cr | L3 | Rejected-Finance HIGHER |
| 4 | L4₹15.3 CrRejected-Finance | ₹15.3 Cr | L4 | Rejected-Finance HIGHER |
| 5 | L5₹15.8 CrRejected-Finance NEAR AANGANBADI CENTRE VPO THOBA DHANI TESHIL DISTT FATEHABAD 125050 | HISAR | HARYANA | 125050 | ₹15.8 Cr | L5 | Rejected-Finance HIGHER |
| Sl No | Description | Qty | Unit | m/s omparkash contractor L1 | P.S. INFRABUILD PRIVATE LIMITED L6 | Raghbir Singh Contractor L2 | Pali Ram Contractor L5 | The Tibba Dana Sher Co Op L and C Society Limited L3 | VIKASH PROBUILD PRIVATE LIMITED L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Credit of old steel bars | 923.8 | Quintal | 3,000 -₹27,71,394 | 3,000 -₹27,71,394 | 3,100 -₹28,63,773.80 | 5,000 -₹46,18,990 | 3,500 -₹32,33,293 | 1,500 -₹13,85,697 |
| 2.00 | credit of bricks and B.Bats available from dismantling of Brick Masonry | 2,657.25 | cum | 880 -₹23,38,383.52 | 880 -₹23,38,383.52 | 950 -₹25,24,391.30 | 1,000 -₹26,57,254 | 1,200 -₹31,88,704.80 | 250 -₹6,64,313.50 |
| 3.00 | Providing and fixing gates and gearing complete in all respect | 33.97 | Sqm | 75,000 ₹25.5 L | 50,000 ₹17.0 L | 65,000 ₹22.1 L | 35,000 ₹11.9 L | 70,000 ₹23.8 L | 50,000 ₹17.0 L |
Tender Value
₹16.8 Cr
EMD Value
₹33.7 L
Closing Date
2 Mar 2026, 1:00 pmClosed
ARUN MUNJAL
Rohtak W.S. Divn. Rohtak
Re-Construction of Aqueduct and Escape at RD 83000 Of Bhalaut Sub Branch (X-Ing DD8) Of Bhalaut Sub Branch.
2026_HRY_502056_1
2026938EFBB4 3AC8 49F4 A87E 6701073FD967125IRR
Open Tender
Civil Works
360 days
KAHNI 12.1/2 WISHVA KAHNI 7.1/2 WISHVA RITHAL NA
3 documents required · 3 mandatory
₹20,000
₹33.7 L
Yes
Room No. 220 1st Floor, Sinchai Bhawan
7 May 2026
11 Feb 2026
2 Mar 2026
11 Feb 2026
2 Mar 2026
11 Feb 2026
19 Feb 2026
Credit of old steel bars
credit of bricks and B.Bats available from dismantling of Brick Masonry
Providing and fixing gates and gearing complete in all respect
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[10.1.1.1]Providing and laying of base course of floors consisting of 100 mm thick cement 1:8:16 and 100 mm sand or stone filling. 1.1. Re-compacting excavated soil in plinth under floors, including watering, ramming, consolidating and dressing complete. [Through Rate]
[10.63.2]Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 2. Size of Tile 600x600 mm [Through Rate]
[11.5.1]12 mm cement plaster of mix : 1. 1:2 (1 cement: 2 fine sand) [Through Rate]
[11.5.3]12 mm cement plaster of mix : 3. 1:4 (1 cement: 4 fine sand) [Through Rate]
[11.58]Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete [Through Rate]
[11.64.1]Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : 1. New work (two or more coats) over and including water thinnable priming coat with cement primer [Through Rate]
[11.82.1]Painting the wooden / metal surface with synthetic enamel paint of approved brand and manufacture to give an even shade : 1. Two or more coats on new work [Through Rate]
[11.95.1]Finishing walls with Acrylic Smooth exterior paint of required shade : 1. New work (Two or more coat applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) [Through Rate]
[13.6.1]Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 1. Using M.S. angels 40x40x6 mm for diagonal braces [Through Rate]
[14.1]Dressing bed and preparation of sub grade for lining by mechanical/ mannual means [Through Rate]
[14.2]Dressing side slopes and preparation of sub grade for lining by mechanical/ mannual means [Through Rate]
[14.71]Excavating, supplying and filling of local earth (including royalty) by mechanical transport up to a lead of 1 km . [Through Rate]
[15.10]Providing and Laying Cutting Edge of Mild Steel weighing 40 kg per metre for Well Foundation complete as per Drawing and Technical specification MORTandH clause 1200 and 1900 [Through Rate]
[15.12.8.2]Plain/Reinforced Cement Concrete, in Well Foundations complete as per Drawing and Technical Specification, in Well Steining 8.2. RCC M35 Grade With Batching Plant, Transit Mixer and Concrete Pump [Through Rate]
[15.13.1.2]Plain/Reinforced Cement Concrete, in Well Foundations complete as per Drawing and Technical Specification, in Bottom Plug Concrete to be placed using tremie pipe 1.2. PCC Grade M20 Using Batching Plant, Transit Mixer and Crane/ concrete pump [Through Rate]
[15.15.2]Plain/Reinforced Cement Concrete, in Well Foundations complete as per Drawing and Technical Specification, in Top Plug 2. Grade M20 PCC Using Concrete Mixer [Through Rate]
[15.16.4.2]Plain/Reinforced Cement Concrete, in Well Foundations complete as per Drawing and Technical Specification, in Well Cap 4.2. RCC Grade M35 Using Batching Plant, Transit Mixer and Concrete Pump [Through Rate]
[15.17.1.1]Sinking of 6 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level MORTandH clause 1200 1.1. Sandy Soil Depth below bed level up to 3.0 M [Through Rate]
[15.17.1.2]Sinking of 6 m external diameter well (other than pneumatic method of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing and technical specifications. Depth of sinking is reckoned from bed level MORTandH clause 1200 1.2. Sandy Soil Beyond 3m up to 10m depth [Through Rate]
[15.26.1]Sand Filling and Water Filling of Wells 1. Sand Filling in Wells complete as per Drawing and Technical Specifications MORT&H clause 1207 [Through Rate]
[16.27]Filling cement bags with sand, sewing and laying in position within 30 metres in water including cost of strings by mechanical/ mannual means. [Through Rate]
[2.B0976] B0976. Empty Cement bags [Rate]
[2.RM079] RM079. Earth Cost or compensation for earth taken from private land [Rate]
[22.104.1]Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 1. 15 mm nominal bore [Through Rate]
[22.107.1]Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 1. 15 mm nominal bore [Through Rate]
[22.221.3]Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect. 3. Size 630 mm x 450 mm x 830 mm [Through Rate]
[22.51.1.1]Providing and fixing soil, waste and vent pipes : 1.1. 100 mm dia Sand cast iron S&S pipe as per IS: 1729 [Through Rate]
[22.52.2]Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes : 2. 100 mm dia pipe [Through Rate]
[22.85.2]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 2. 20 mm nominal outer dia Pipes [Through Rate]
[23.23.4]MISCELLANEOUS 4. Providing and fixing fan hook made from 8 mm dia MS rod 75 cm long of required shape and size [Through Rate]
[23.3.6.1]COPPER WIRING IN PVC CONDUIT (SURFACE/RECESS) 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) [Through Rate]
[23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. [Through Rate]
[23.8.1.13]FITTING AND ACCESSORIES 1.13. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Socket size rotary step type Electronic regulator for A.C. ceiling fan [Through Rate]
[23.8.1.2]FITTING AND ACCESSORIES 1.2. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. Wall socket 5 amp on existing sheet. [Through Rate]
[23.8.1.3]FITTING AND ACCESSORIES 1.3. Providing and fixing Piano type accessories of approved make in existing box and Bakelite sheet including fixing and making necessary connections, complete in all respect. 15 amp. switch on existing sheet. [Through Rate]
[23.8.3.4]FITTING AND ACCESSORIES 3.4. Supply and erection of suitable MS/GI Box covered with 5 mm thick Bakelite sheet as below 200 mm X 150 mm X 60 mm deep metal box [Through Rate]
[23.8.4]FITTING AND ACCESSORIES 4. Supply and erection of 10.5 cm dia M.S.Fan box including 8 mm dia 30 cm long M.S. Road made into suitable suspension hook and erected in R.C.C. slab for the erection of fan complete with all labour and material required to complete the job. [Through Rate]
[27.1]Brick masonry work in 1:3 in sub-structure including scaffolding complete excluding pointing and plastering, as per drawing and MoRTandH Specifications 1300 and 2200 [Through Rate]
[27.11.1.2]RCC Grade M30 1.2. With Batching Plant, Transit Mixer and Concrete Pump [Through Rate]
[27.13]Supplying, fitting and placing HYSD bar reinforcement in sub-structure complete as per drawing and MoRTandH Specifications 1600 & 2200. [Through Rate]
[27.15]Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing force. Complete as per drawing and MoRTandH Specifications 2706 & 2200. [Through Rate]
[27.17]Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MoRTH specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and MoRTH and Specification 710.1.4 of IRC: 78 and 2200. [Through Rate]
[27.30.1.1]Using Batching Plant, Transit Mixer and Concrete Pump. 1.1. For formwork and staging add the following: For solid slab super-structure, 20-30 per cent of labour, material and machinery cost Height up to 5m [Through Rate]
[27.44.2]Drainage Spouts complete as per drawing no. SD/205 and MoRTandH MoRTandH specification clause 2705 with 6 meter long GI 100 mm dia drainage GI light grade pipe (For Bridges) 2. For fixing in position [Through Rate]
[27.49]Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 sqm and MORT&H specification 800. [Through Rate]
[27.5]Plain/Re-inforced cement concrete in sub-structure complete as per drawing and MoRTandH specifications 1500,1700 and 2200. PCC Grade M15 (with concrete Mixer) Height up to 5m [Through Rate]
[27.51.3]Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. [Through Rate]
[35.6]Providing and laying boulders apron on river bed for protection against scour with stone boulders weighing not less than 40 kg each complete as per drawing and Technical specification. Boulder Laid Dry Without Wire Crates. Including excavation for trimming for preparation of bed. Nominal excavation required for preparation of bed has been taken into account while making provision for labour. [Through Rate]
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
[4.32]Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. [Through Rate]
[5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate]
[5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate]
[5.29.2]Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 2. Of area beyond 3 sq. metres [Through Rate]
[5.33]Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. [Through Rate]
[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
[6.1.4]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 4. 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) [Through Rate]
[6.14.1]Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) [Through Rate]
[6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform [Through Rate]
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
[6.34.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect above plinth level Note:- Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars [Through Rate]
[6.8.2]Providing and laying damp-proof course with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) 2. 40mm thick [Through Rate]
[7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
[7.22.1]Brick work with common burnt clay non-modular bricks of class designation 10.5 in superstructure above plinth level up to floor IV level in all shapes and sizes in : 1. Cement mortar 1:4 (1 cement : 4 coarse sand) [Through Rate]
[9.11.1]10 cm thick (average) mud phaska of damped brick earth on roofs laid to slope consolidated and plastered with 25 mm thick mud mortar mixed with bhusa @ 35 kg per cum of earth and gobri leaping with mix 1:1 (1 clay : 1 cow dung) and covered with flat tile bricks, grouted with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement and finished neat: 1. With common burnt clay non-modular brick tile of class designation 10 [Through Rate]
[9.18]Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_580711.xls
BOQ • 0.43 MB
OT0150946.pdf
Other Document • 0.79 MB
Download all tender documents and submit your bid