Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.9 LAccepted-AOC 46 S P MUKHERJEE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹50.9 L | L1 | Accepted-AOC AOC_Issued |
| 2 | L2₹55.6 LRejected-Finance 97 RAJA RAMMOHAN ROY ROAD SIRITY KOLKATA WEST BENGAL 700041 WB10A0004871 | KOLKATA | WEST BENGAL | 700041 | ₹55.6 L | L2 | Rejected-Finance that the bid is not L1 |
| 3 | L3₹61.2 LRejected-Finance | ₹61.2 L | L3 | Rejected-Finance that the bid is not L1 |
| 4 | Rejected-Technical | - | - | Rejected-Technical due to absence of Electrical Supervisor License part no. 3,4,7(a) respectively |
| Sl No | Description | Qty | Unit | C. CHOWDHURY AND CO L1 | switching avo Electro Power Ltd L2 | Rajalakshmi Enterprise L3 |
|---|---|---|---|---|---|---|
| 1.00 | PART-A
Supply and installation of SMF FR battery of capacity -- 65AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 10 KVA UPS | 238 | Ea. | 4,499 ₹10.7 L | 5,955 ₹14.2 L | 6,551 ₹15.6 L |
| 2.00 | Supply and installation of SMF FR battery of capacity -- 42AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 20/10 KVA UPS | 184 | Ea. | 3,459 ₹6.4 L | 4,364 ₹8.0 L | 4,801 ₹8.8 L |
| 3.00 | Supply and installation of SMF FR battery of capacity -- 26AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 6 KVA UPS | 48 | Ea. | 2,449 ₹1.2 L | 2,816 ₹1.4 L | 3,098 ₹1.5 L |
| 4.00 | SITC of 5 KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology having minimum output power factor 0.8 with 240V Single phase input & 240V single phase output and following minimum accessories. (Numeric/AVO/APC/Delta/Vertiv/Emerson).
(at MC Hub substation)
a) in built / External isolation Transformer
b) Suitable size Battery rack
c) Total minimum 5376VAH SMF battery for each UPS to provide 30mins. Battery backup at Full load. Make: Amararaja Quanta / Exide Power Safe | 1 | Ea. | 1,25,000 ₹1.3 L | 1,01,000 ₹1.0 L | 1,11,100 ₹1.1 L |
| 5.00 | PART-B
Supply and installation of SMF FR battery of capacity -- 65AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 10 KVA UPS | 16 | Ea. | 4,499 ₹71,984 | 5,955 ₹95,280 | 6,551 ₹1.0 L |
| 6.00 | Supply and installation of SMF battery of capacity -- 42AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 20/10 KVA UPS | 120 | Ea. | 3,449 ₹4.1 L | 4,364 ₹5.2 L | 4,801 ₹5.8 L |
| 7.00 | PART-C
SITC of 5 KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology having minimum output power factor 0.8 with 240V Single phase input & 240V single phase output and following minimum accessories. (Numeric/AVO/APC/Delta/Vertiv/Emerson).
a) in built / External isolation Transformer
b) Suitable size Battery rack
c) Total minimum 5376VAH SMF FR battery for each UPS to provide 30mins. Battery backup at Full load. Make: Amararaja Quanta / Exide Power Safe | 4 | Ea. | 1,25,000 ₹5 L | 1,01,000 ₹4.0 L | 1,11,100 ₹4.4 L |
| 8.00 | Supply and installation of SMF FR battery of capacity -- 65AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 10 KVA UPS | 60 | Ea. | 4,499 ₹2.7 L | 5,955 ₹3.6 L | 6,551 ₹3.9 L |
| 9.00 | Supply and installation of SMF FR battery of capacity -- 42AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 20/10 KVA UPS | 16 | Ea. | 3,449 ₹55,184 | 4,364 ₹69,824 | 4,801 ₹76,816 |
| 10.00 | Supply and installation of SMF FR battery of capacity -- 26AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 6 KVA UPS | 60 | Ea. | 2,449 ₹1.5 L | 2,816 ₹1.7 L | 3,098 ₹1.9 L |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
19 Feb 2022, 1:00 pmClosed
EE II KNHED PW Dte.
KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata -700073
Strengthening of power back up system by replacement of old Inverter UPS and battery installed at different buildings of Kolkata Medical College Hospital
2022_PWDE_364132_1
WBPWD/EEII/KNHED/NIQ-122/21-22
Open Tender
ELECTRICAL WORKS ORG
60 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.2 L
6 May 2026
2 Feb 2022
21 Feb 2022
4 Feb 2022
19 Feb 2022
4 Feb 2022
Amount
PART-A Supply and installation of SMF FR battery of capacity -- 65AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 10 KVA UPS
Supply and installation of SMF FR battery of capacity -- 42AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 20/10 KVA UPS
Supply and installation of SMF FR battery of capacity -- 26AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 6 KVA UPS
SITC of 5 KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology having minimum output power factor 0.8 with 240V Single phase input & 240V single phase output and following minimum accessories. (Numeric/AVO/APC/Delta/Vertiv/Emerson). (at MC Hub substation) a) in built / External isolation Transformer b) Suitable size Battery rack c) Total minimum 5376VAH SMF battery for each UPS to provide 30mins. Battery backup at Full load. Make: Amararaja Quanta / Exide Power Safe
PART-B Supply and installation of SMF FR battery of capacity -- 65AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 10 KVA UPS
Supply and installation of SMF battery of capacity -- 42AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 20/10 KVA UPS
PART-C SITC of 5 KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology having minimum output power factor 0.8 with 240V Single phase input & 240V single phase output and following minimum accessories. (Numeric/AVO/APC/Delta/Vertiv/Emerson). a) in built / External isolation Transformer b) Suitable size Battery rack c) Total minimum 5376VAH SMF FR battery for each UPS to provide 30mins. Battery backup at Full load. Make: Amararaja Quanta / Exide Power Safe
Supply and installation of SMF FR battery of capacity -- 65AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 10 KVA UPS
Supply and installation of SMF FR battery of capacity -- 42AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 20/10 KVA UPS
Supply and installation of SMF FR battery of capacity -- 26AH, 12V, (make-- Exide/Amaron, model-- MED VRLA/Quanta) for 6 KVA UPS
Part-D Supplying and fixing 20mm dia.PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works
(a) Supplying and fixing 32A,230V front-operated Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc. (Make - Havells / HPL/LT/ABB)
(b)Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A,SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl.S&F 20 A SP MCB breaking capcity 10kA C- Curve) in SS enclosure fixed on wall and cecessary conection make Siemens/LT/Schneider/ABB
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (RR Kabel /Polycab/ Havells) of the following sizes in the prelaid rigid pipe and by the prelaid GI fish wire and making necy. connection as required. a. 2 x 6 +1x4 Sq.mm copper wire
S & F of Netguard for battery rack and UPS machine with 35x35x5mm MS angle and 25x6mm MS flat (approval of Drawing of rack required before construction)
SITC of 6 KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology having minimum output power factor 0.8 with 240V Single phase input & 240V single phase output and following minimum accessories.(Replacement of 2KVA Inverter at Director Room,RIO) a) In built/ External isolation Transformer b) Paralelling kit. c) Suitable size Battery rack d) Total minimum 5376VAH FR SMF battery for each UPS to provide 30mins. Batterybackup at Full load. Make : Amararaja Quanta / Exide Power Safe [ VERTIV make Liebert ITA 6KVA /AVO/ NUMERIC make Digital MAX 6KVA/ APC Model No. SRCE6KUXI with additional Isolation Transformer/ Emerson/Delta]
S & Fixing of 12V, 65AH (Exide/Amaron make, EP65-12) SMF FR battery in the existing two nos UPS rack incl. interconnections with batteries.
S & Fixing of 12V, 28AH (Exide/Amaron make, EP28-12) SMF FR battery in the existing UPS rack incl. interconnections with batteries.
Commissioning of two nos UPS with batteries online/Noload with main supply as per direction of EIC and submission of Test certificate and warranty cards.
Part-D SITC of 5 KVA True Online Double Conversion IGBT based UPS system with Advanced DSP based Technology having minimum output power factor 0.8 with 240V Single phase input & 240V single phase output and following minimum accessories.(Numeric/AVO/APC/Emerson/Vertiv/Delta) a) in built / External isolation Transformer b) Suitable size Battery rack c) Total minimum 5376VAH SMF FR battery for each UPS to provide 30mins. Battery backup at Full load. Make: Amararaja Quanta / Exide Power Safe
PART-E E.I work Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works. vide pg noE-16 item no. 7(a) 20 mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. (Vide page no E 9 Item no 1) 2 x 6 sqmm + 1 x 4 sqmm
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes .vide pg no F-5 item no. 9 4 sqmm
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and nececessary conection( make Legrand) (vide pg no. D-12 it. no. 17)
Supplying and fixing 240 V ,32 A,DP Changeover switch with Sheet Steel enclosure on flat iron frame on wall with nuts bolts etc( mk -havells) vide pg no. D-1 item no. 2a
PART-F Miscellaneous work Supply & errection of special type Pilfer proof Inverter & battery net guard of giving deep fabrication to suitable M.S. angle, flats and the Section 1"x1" 10 SWG welded mech I.R.C. netting suitable for fixing on wall covering the existing Inverter & battery, should be sterdely and electri- cally welded in a measurement of front side of the board should be covered by 2 Nos. door palla made of 25mmX 5mm flat (column & vertical) and inverter & battery guard structure should be made of 40X40X5mm angle left & right side of the inverter & battery will be covered by 1"x1" , 10SWG I.R.C. Net & also raised on same combination be covered by 10 SWG I.R.C. Net with help of reqd. angle & flat to cover up fabrication will be complete in a compact position finally the protection should be painted with moisture proof red oxide primer & approved paint incl. carrying charge
Dismantling the existing batteries from UPS rack after disconnecting all the batteries and carry the dismantled materials to section store.
S & F of lead acid dry cell SMF batteries of ratting 12 V, 26 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections.
S & F of lead acid dry cell SMF batteries of ratting 12 V, 65 AH(mk.-Exide:- power safe/Amaron) in existing UPS rack incl. Interconnections.
S & F of lead acid dry cell SMF batteries of ratting 12 V, 28 AH(mk.-Exide:- power safe/Amaron)in existing UPS rack incl. Interconnections.
Commissioning of UPS with batteries online/No Load with main supply as per direction of EIC and Submission of test certificate and warranty cards.
Less cost for old unserviceable battery and dismantled materials will be deducted from gross bill for Rs 250000.00/-
Special Terms and Conditions 1. It is stated that the above work place is existing COVID Hospital, In case of any mishap or accidental to any staff that deputed by the agency the whole responsibility is to be borne by the concern agency. 2. The Agency shall be responsible for provisioning of all COVID safety measures including regular sanitiziation of work places, vaccination of employees and compliance of stated directive and COVID appropriate norms. 3. All the issues related to the safety of the staffs should be taken care by the agency itself. (Defect Labilities period for 02 year from the date of completion of work) (Rate should be quotated including all taxes and duties)
switching avo Electro Power Ltd
Rajalakshmi Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.48 MB
2911.pdf
Tender Documents • 1.86 MB
suspension.pdf
Additional Documents • 2.91 MB
BOQ_705915.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid