| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.6 LAccepted-AOC 528 PREETI NAGAR 125001 | HISAR | HARYANA | 125001 | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹14.5 L+₹96,200 (7.09%)Rejected-AOC | L2 | Rejected-AOC WORK AWARDED TO L1 BIDDER | |
| 3 | L3₹16.8 L+₹3.2 L (23.6%)Rejected-AOC 7 SUNDER NAGAR PTPS COLONY GATE NO 03 PANIPAT | PANIPAT | HARYANA | L3 | Rejected-AOC WORK AWARDED TO L1 BIDDER | |
| 4 | Rejected-Technical N A | NA | NA | 121004 | - | Rejected-Technical PQR NOT FULFILLED AS PER NIT | |
| 5 | Rejected-Technical KADARPUR ROAD KADARPUR ROAD NEAR PARJAPATI DHARAMSHALA BADSHAPUR GURUGRAM 122001 | GURUGRAM | HARYANA | 122001 | - | Rejected-Technical PQR NOT FULFILLED AS PER NIT |
Tender Value
Refer Docs
EMD Value
₹28,700
Closing Date
6 Oct 2023, 6:00 pmClosed
TINKU
CE RGTPP Khedar Hisar
Annual Civil Works Maintenance of outside area of multistory residential and non-residential buildings for height above 4 m upto 30.20 m (Eight Storey) on exterior side in RGTPP Colony Khedar for the FY 2023-24
2023_HBC_311197_1
2023DC26F4C7 93FF 485E BFAD EDE48333D4CB712PGC
Open Tender
Civil Works
Works
365 days
RGTPP COLONY KHEDAR
AS PER NIT
2 documents required · 2 mandatory
₹1,180
₹28,700
Yes
15 Jan 2024
14 Sept 2023
10 Oct 2023
14 Sept 2023
6 Oct 2023
14 Sept 2023
Amount
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes- 110 mm dia pipe including fittings such as socket/tee/elbow/clamping of pipe as per requirement at height from 4 m upto 4th floor (15.60 m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes- 75 mm dia pipe including fittings such as socket/tee/elbow/clamping of pipe as per requirement at height from 4 m upto 4th floor (15.60 m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 50 mm/ 62.50 mm dia. PVC pipe of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince including fittings such as socket/tee/elbow/clamping of pipe as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of Chlorinated polyvinyl chloride (CPVC) of 25 mm outer dia. pipes of ISI mark/approved brand (as per satisfaction of Er-in-charge) including connected all CPVC plain and brass threaded fittings such as Socket/Tee/Elbow/clamping of pipes/jointing of pipes with CPVC solvent cement as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of Chlorinated polyvinyl chloride (CPVC) of 20 mm outer dia. pipes of ISI mark/approved brand (as per satisfaction of Er-in-charge) including connected all CPVC plain and brass threaded fittings such as Socket/Tee/Elbow/clamping of pipes/jointing of pipes with CPVC solvent cement as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion – Bend/Elbow 87.5°- 110 mm bend. (as per satisfaction of Er-in-charge) as per requirement at height from 4 m upto 4th floor 7(15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion – Bend/Elbow 87.5°- 75 mm bend. (as per satisfaction of Er-in-charge) as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 50 mm/62.5 mm dia. PVC elbow of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion – Coupler/Socket - 110 mm. (as per satisfaction of Er-in-charge) as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 50 mm/ 62.5 mm PVC Sockets of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of PVC Tee of 50 mm-63 mm dia. of of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince (as per satisfaction of Er-in-charge) including jointing with pipe as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 110 mm x 50 mm PVC Tee of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 75 mm x 50 mm PVC Tee of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI elbow dia. ¾” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI elbow dia. 1” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI union dia. 3/4” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI union dia. 1” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and Fixing CI/MS clamps of ISI mark/approved brand (as per satisfaction of Er-in-charge) to support the PVC/CPVC, CI, GI pipes etc. of any size at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Carrying out following work at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (a)Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge upto 50 mm average thickness and (b) 20 mm thick cement plaster 1:2 in 2 coats work
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.Metres and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge : with cement mortar of ratio 1 : 4 (1 Cement : 4 Coarse Sand) at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS Item)
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar,including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-inCharge. at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS Item)
Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS Item)
Chowkats of commercial hard wood such as hollock, champ, chikassy and chaplash etc.,(Non-coniferous timber other than teak conforming to I.S. specification no.1003 kiln seasoned, of doors and windows including iron hold fasts, corner straps, screws, bolts for hold fasts, etc., complete fixed in position at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:: 75 to 80 mm dia pipe at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:: 100 mm dia pipe at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required- In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works at height from 4 m upto 4th floor (15.60m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes- 110 mm dia pipe including fittings such as socket/tee/elbow/clamping of pipe as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 50 mm/ 62.50 mm dia. PVC pipe of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince including fittings such as socket/tee/elbow/clamping of pipe as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of Chlorinated polyvinyl chloride (CPVC) of 20 mm outer dia. pipes of ISI mark/approved brand (as per satisfaction of Er-in-charge) including connected all CPVC plain and brass threaded fittings such as Socket/Tee/Elbow/clamping of pipes/jointing of pipes with CPVC solvent cement as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion – Bend/Elbow 87.5°- 75 mm bend. (as per satisfaction of Er-in-charge) as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 50 mm/62.5 mm dia. PVC elbow of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion – Coupler/Socket - 110 mm. (as per satisfaction of Er-in-charge) as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for Unplasticised Rigid PVC rain water pipes conforming to IS :13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion - Coupler/Socket - 75 mm. (as per satisfaction of Er-in-charge) as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 50 mm/ 62.5 mm PVC Sockets of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 110 mm x 50 mm PVC Tee of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing 75 mm x 50 mm PVC Tee of Finolex/Diplast/Supreme/UniK(1st quality)/Zolloto/prince as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI elbow dia. ¾” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI elbow dia. 1” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI union dia. 3/4” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of GI union dia. 1” of ISI mark/approved brand (as per satisfaction of Er-in-charge) including jointing with pipe with CPVC solvent cement as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and Fixing CI/MS clamps of ISI mark/approved brand (as per satisfaction of Er-in-charge) to support the PVC/CPVC, CI, GI pipes etc. of any size at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Carrying out following work at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (a)Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge upto 50 mm average thickness and (b) 20 mm thick cement plaster 1:2 in 2 coats work
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.Metres and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge: with cement mortar of ratio 1 : 4 (1 Cement : 4 Coarse Sand) at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS Item)
Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 sqm and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar,including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-inCharge. at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS Item)
Providing and fixing of chicken wire mesh for avoiding cracks in plaster with necessary nail/screws etc. complete in all respect to the entire satisfaction of engineer-in-charge at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc.(NS Item)
Chowkats of commercial hard wood such as hollock, champ, chikassy and chaplash etc.,(Non-coniferous timber other than teak conforming to I.S. specification no.1003 kiln seasoned, of doors and windows including iron hold fasts, corner straps, screws, bolts for hold fasts, etc., complete fixed in position at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:: 75 to 80 mm dia pipe at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead:: 100 mm dia pipe at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required- In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item)
Providing and fixing of Chlorinated polyvinyl chloride (CPVC) of 25 mm outer dia. pipes of ISI mark/approved brand (as per satisfaction of Er-in-charge) including connected all CPVC plain and brass threaded fittings such as Socket/Tee/Elbow/clamping of pipes/jointing of pipes with CPVC solvent cement as per requirement at height from 4th floor (15.60 m) to 8th floor (30.20m) by using scaffolding and / or other required T and Ps etc. (NS item) site at their own cost.
VARUN BANSAL
aashirwad engineering
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .