Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC PULGAON | L1 | Accepted-AOC AOC | |
| 2 | L2₹35.4 L+₹1.3 L (3.96%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹35.4 L+₹1.4 L (4.08%)Rejected-Finance | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹36.5 L+₹2.4 L (7.17%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L4 | Rejected-Finance Other than Lowest | |
| 5 | L5₹36.5 L+₹2.4 L (7.20%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L5 | Rejected-Finance Other than Lowest |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
16 Mar 2023, 6:00 pmClosed
GE PULGAON
GE PULGAON CAD CAMP
REPAIR AND MAINTENANCE OF FIRE FIGHTING SERVICES FIRE ALARM SYSTEM AND CONNECTED MISC WORKS INSIDE DEPOT AREA AT CAD PULGAON UNDER GE PULGAON
2023_MES_583076_2
9065/PUL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE PULGAON
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE PULGAON
₹70,000
Yes
24 Mar 2023
25 Feb 2023
23 Mar 2023
25 Feb 2023
16 Mar 2023
11 Mar 2023
27 Feb 2023 - 10 Mar 2023
Amount
Upkeep of following equipment /machinery installed at pump house in/near building No. P-6 comprising of foam sprinkler and water sprinkler system for cooling and washing of floor, stainless steel piping with large No of opening to maintain the required discharge of water, regular flow of foam for detecting defective items and periodical minor repairs such as oiling, greasing, rubber gaskets and providing glands and all as necessary minor repairs required for proper functining of equipments complete all as specified and as directed including all the items listed in below:-
Automatic foam sprinkler system including stainless steel tank complete and filling of foam as per direction.
Centrifugal pumping set electric driven - 01 set
Standby diesel engine operated centrifugal pumping set auto/manual start- 01 set
Jockey centrifugal pump electric driven auto/manual start- 01 set
Sluice valves, NRVs off sizes alongwith pipe line
LT Panel Board with all accessories and power cables.
Note:- (i) Testing will be carried out on Monthly basis and contractor submit the test report duly signed by users rep every month and all as specified and directed by Engr-in-charge . Testing shall be measured and paid separately. (ii) The rates of Oil, grease, rubber gaskets, and gland are deemed to be incl in above quoted rates. (iii) Any welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above quoted rates. (iv) Documents as specified are maintined and put to EIC monthly. (v) Contractor shall arrange transportation of foam drum from AGE E/M store to Pump house and filling of foam in stainless steel tank insatalled at above bldgs deemed to included in above quoted rates. (vi) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repairs. Note:- The Rate mentioned in Item No 1 For 1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time.
All as per item No 1 ……………. but for buildings No P-14 complete all as specified and directed.
Upkeep of following equipment /machinery installed at pump house in/near building No P-1 water sprinkler system for cooling & washing of floor of bldg No P-1,P-10 comprising of stainless steel piping with large No of opening to maintain the required discharge of water for detecting defective items and periodical minor repairs such as oiling, greasing, rubber gaskets and providing glands and all as necessary minor repairs required for proper functioning of equipments complete all as specified and as directed including all the items listed in below:-
Cetnrifugal pumping set electric driven - 02 set
Sluice valves, NRVs off sizes alongwith pipe line
LT Panel Board with all accessories and power cables.
Note:- (i) Testing will be carried out on monthly basis and contractor submit the test report duly signed by users rep every month and all as specified and directed by Engr-in-Charge. Testing shall be measured and paid separately under respective items. (ii) The rates of Oil, grease, rubber gaskets, and gland are deemed to be included in above quoted rates. (iii) Any welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above quoted rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately in supply and fix in repairs. (v) The quoted rate shall cover for entire period of 365 days(including Sunday and Holiday). Note:- The Rate mentioned in Item No 3 For 1 Year Duration. Panel recovery of Rs 2000 Per Month shall be recovered if contractor fails to testing on monthly basis at due time.
Testing of Foam Sprinkler system installed at P-6 and P-14 sheds complete all as specified and as directed. Note: One testing in one building will be one Job
Testing of water sprinkler system installed at P-1, P-6 P-10 and P-14 sheds complete all as specified and directed. Note: One testing in one building will be one Job
Supply and fix in repairs foam spray nozzle made of stainless steel (SS304) construction with 1/2 " male BSP threaded inlet. The nozzle shall have K Factor of 30/45 and shall have aeratingarrangement to give foam of expansion 1:3 to 1:6 and suitable pattern for covarage of risk area
Supply & fix in repair Conventional 24 V DC Electronic Hooter cum Flasher. Make : spencer / Honeywell / Fire Light / NotiFier/ Ravel
Supply & fix in repair 15 mm (½") dia. NBCM Body chrome finished side wall type sprinkler / Spray nozzle Medium Velocity having rating with deflector disc of conventional construction with all accessories require to install. Make: Kartar / Shah Bhogilal / HD / Newage
Maintenance repair & testing of fire hydrant system installed at bldg shed No P-1 to P-17 'F' sub Depot including maintenance of following Parts complete all as specified and as directed.
Fire hydrant valves from outside and inside
Fire boxes from outside and insde
Female coupling lugs and repair to spring nut
Hose reel leakage and make good the same
Gland, all rubber parts
Note:- (i) Testing will be carried out quaterly basis and contractor submit the test report duly signed by users rep every quarter and all as specified and directed. Testing charges shall deemed to be included in unit rate quoted. (ii) Oil, grease, rubber guskets, and gland are deemed to be included in above quoted rates. (iii) Any lathe work, welding work , cutting of exisitng pipes inserting MS/GI / CI fittings , replacing steel pipe , sprinkler is deemed to be incl in above quoted rates. (iv) Documents as specified are maintined and put to Engr-in-Charge monthly. (v) Connected Spares required for replacement of unserviceable parts shall be measured and paid separately as supply and fix as and when required. (vi) M & R shall be quarterly and considered one job for one bldg. (vii) Panel recovery of Rs 3000 Per Qtr shall be recovered if contractor fails to testing on quarterly basis at due time.
Supply and fix in repair Weather proof hose cabinet of size 750 x 600 x 250 mm fabricated from M.S. angle iron sections and 18 GMS sheet with full glass door and locking arrangement suitable to accommodate - 2Nos 15 M long hoses and 1 No branch pipe and nozzle including stand of exisitng height . The cabinet shall be painted with one coat of primer and two or more coats of synthetic enamel paint of approved make and shade and shall be suitably mounted.
Supply and fix in repairs SS 304 Short Branch Pipe 63 mm with necessary accessories conforming to IS : 903 ISI marked. (Make : Newage / Swati / Shah Bhogilal /. Arihant)
Supply and fix in repair of Hydrant Valve Oblique Type 63 mm complete made out of SS 304 fitted with PVC main blank cap and GI Chain IS 5290 with ISI mark complete all as specified and as directed (Make : Newage/Kartar/Shah Bhogilal / Arihant)
Supply and fix in repair Hydrant valve wheel cast iron type suitable for 63mm dia hydrant valve complete all as specified and as directed
Supply and fix in replace RRL hose pipe 63 mm dia & 15 meter long with male and female coupling with ISI mark complete all as specified and as directed.
Supply and fix in repair Hydrant cap with chain for 63mm dia hydrant valve.
M & L for painting of fire hydrant boxes with stand, Hydrant Valves and MS pipe over the ground level after preparation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and as directed.
Maintenance & repairs to smoke / heat detector as well as repeater automatic fire alarm system complete with fixed temperature,heat detector,main control panel cabling 24 volt SC with FRLScable with rectifier,24 volts battery with charger unit complete installed at P-1, P-6 P-10 and P-14 sheds of 'F' sub depot and 104 AC shed in 'B' sub depot complete all as spcified and as directed.
Supply & fix in repair ionization smoke detector from shed with base plate complete all as specified and directed. Make: System sensor / Honeywell/Fire light/ Notifier
Supply & fix in repairs heat detector in shed with base plate complete with base plate complete all as specified and directed. Make: System sensor / Honeywell/Fire light/ Notifier
Supply & fix in repairs Beam detector with Reflectors range 15 mtr x 15 mtr x 60 mtr Operating voltage 24 V DC with adjustable convex mirror (all required Accessories.) complete all as specified and as directed Make : System Sensor / Honeywell / Fire Light / Notifier
Supply & fix in repair Conventional Manual call point.complete all as specified and as directed. Make : spencer / Honeywell / Fire Light / Notifier
Supply and lay in replacement of copper conductor armoured cable FRLSH of size 2 core x 1.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed . Make : POLYCAB/ PLAZA/ HAVELLS.
Supply and lay in replacement of copper conductor armoured cable FRLSH of size 4 core x 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed. Make : POLYCAB/ PLAZA/ HAVELLS.
Supply and fix in replacement of 12 Volts 7 Amps maintenance free dry cell battery, complete all as specified and as directed. Make : EXIDE / AMCO / TATA GREEN.
Supply and lay in replacement of copper conductor PVC cable FRLSH of size 2 core x 2.5 Sqmm on wall / ground with necessary clamps complete all as specified and as directed. Make : POLYCAB/ PLAZA/ HAVELLS.
Taking down existing pipe of any type & supply and laying MS Pipe 'C' Class by of following bore all as specified and directed by Engr-in-Charge.Make:-Prakash Surya,Jindal
200 mm bore
150 mm bore
100 mm bore
80 mm bore
50 mm bore
Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for above bore pipe deemend to including in above quoted rates
Taking down existing union and supply and inserting GI union of 50mm bore complete all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to in included above quoted rates
Taking down existing gate valve and supply and fix gun metal gate valve of 50mm bore all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to be included in above quoted rates.
Taking down existing NRV and supply and fix new Stainless steel NRV of following bore complete all as specified and directed. Note :- Cutting of exisitng pipe, welding works and inserting for fixing of gate valve deemed to be included in above quoted rates.
50 mm bore
100 mm bore
Taking down existing sluice valve and supply and fix new sluice valve PN 1.6 of following bore complete all as specified and directed.
200 mm bore
150 mm bore
100 mm bore
80 mm bore
65 mm bore
Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemed to be included in above quoted rates.
Taking down existing foot valve and supply and fix CI foot valve of latest model of following bore complete all as specified and as directed . Make:- Normex or as equivalent.
200 mm bore
150 mm bore
100 mm bore
Note :- Cutting of exisitng pipe, welding works and inserting any type of fittings for fixing of sluice valve deemend to be included in above quoted rates.
Taking out the burnt electric motor of capacity 5.0 HP to 7.5 HP from existing position, transporting to civil work shop, separating the stator and rotor housing, cutting and removing the existing winding of stator completely, cleaning the slots and rewinding with existing gauge of super enamelled copper winding wire with suitable insulation, applying insulation varnish and heating in heating chamber till completely dried and reassembling the motor including supply and replacement of DE(01 No.) &NDE(01 No) bearings (make: NBC/SKF/TATA), transporting back to site and re-installing in its original position including proper alignment for smooth running and testing on completion complete all as specified and directed .
All as per item no 32.00 but for 12.5 HP to 15 HP motor
All as per item no 32.00 but for 40 HP to 15 HP motor
All as per item no 32.00 but for 75 HP to 80 HP motor
M&L for taking out the defective pump set of capacity upto 5 HP to 15 HP of AC plant from existing position by carefully disconnecting all water pipe lines and electrical cables and carrying out overhauling by dismantling the pump casing, cleaning of the impeller and supply and replacement of Gunmetal bush(01 No), gland plate (01 No.) alongwith studs, nuts, gland packing rope, greasing and re-assembling and re-installing in its original position and testing on completion complete all as specified. Note:-spare parts other than mentioned above under this item will be measured and paid separately as supply only.
All as per item No 36.00 but for pump capacity 40 HP to 80 HP
supply only end ball / roller bearing set with good quality grease suitable for pump sets upto 5 HP to 15 HP Make:NBC/SKF/Tata
supply only end ball / roller bearing set with good quality grease suitable for pump sets 40 HP to 80 HP Make:NBC/SKF/Tata
Supply only star coupling key any size as per sample complete all as specified and as directed.
supply only pump shaft suitable for pump sets 5 HP to 15 HP capacity complete all as specified and as directed.
supply only pump shaft suitable for pump sets 40 HP to 80 HP capacitycomplete all as specified and as directed.
Supply only pump impeller brass suitable for pump sets 5 HP to 15 HP capacity complete all as specified and as directed.
Supply only pump impeller brass suitable for pump sets 40 HP to 80 HP capacity complete all as specified and as directed.
Supply only pump impeller brass suitable for pump sets 40 HP to 80 HP capacity complete all as specified and as directed.
Material and labour for CI special/fittings suitable for CI flanged/socket ends pipe upto 200mm bore such as bends, (any radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc) tee piece, single branch 'Y' junctin, double branch, cross (all flanged), collars, caps & plug, tail pieces, reducers, mechanical joint etc complete including taking out old fittings complete all as specified and as directed.
Repair and Maintenance of Electric operated siren of range 3 to 5KM directly coupled with 3 HP 415 V 3 phase electric motor complete all as specified and directed . (Note Items such as PVC copper wire, lugs, thimbles, nuts, bolts, washer, PVC termination ,lathe work if any are deemend to be included in above quoted rates). Note: rewinding shall be measured and paid separately
M&L for Re-winding of motor of Electric operated siren 3 HP with exisitng sizes/ guage copper wire , testing complete
Servicing of Diesel Engine installed at P-4, P-6 and P-14 and taking out the defective/unserviceable parts and re-assembling the same after repair/replaced and testing complete all as specified and directed. (Note : U/S spare parts shall be measured and paid separately as supply only here in after).
Diesel filter exisitng size
Oil filter exisitng size
Air filter exisitng size
Fan belt exisitng size
Supply and pouring of coolant suitable for radiator as per the requirement of time to time as directed by Engr-in-charge for various capacities of DG Set complete all as specified and as directed.
Supply and filling lubrication oil SAE-40 ( 20 W- 40 grade) of Make SERVO OF IOC/HINDUSTAN PETROLEUM/BPCL/ CASTROL) as approved by GE.
Supply and fix Battery Terminals (Positive and Negative - one set) copper 12V suitable for 100 / 120/ 180 AH as per existing complete all as specified and directed .
Supply and fix Battery led (Positive and Negative - one set) copper not less than 1 meter with suitable for 180 AH as per existing complete all as specified and directed.
Supply and filling distilled water for exisitng power backup system complete all as specified and as directed.
M & L for painting complete equipments / machinery / pipes / valves / Elect Panels etc installed at pump house for P-1, P-6 and P-14 after prepation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and directed.
M & L for painting complete equipments / machinery / pipes / valves / Elect Panels etc installed at foam pump house of P-6 and P-14 after prepation of old painted surface with two coat of exisiting colour synthetic enamelled paint complete all as specified and directed .
Supply, Installation in repairsTesting & Commissioning of 8 Zone Microprocessor based conventional type Fire Alarm Panel incl following items
Panel indicator LCD.
Fault Indicator
Short Indicator
Zone Isolate Indicator
System Ok Indicator
Fire Indicator
Supply Fault Indicator
Panel fabricated of 16SWG CRCA Sheet Make : spencer / Honeywell / Fire Light / Notifier
Supply and fix in replace of MCCB 3 Pole 100Amp 16kA 415V AC, 50 Hz of fixed type magnetic release to the existing panel board complete all as speciifed and directed. Make L&T/Havels/CG
Supply and fix in replace of MCCB 3 Pole 160 Amp 36kA 415V AC, 50 Hz of fixed type magnetic release to the existing panel board into the existing panel board complete all as speciifed and as directed . Make L&T/Havels/CG
Supply and fix in replace of MCCB 3 Pole 200Amp 36kA 415V AC, 50 Hz of fixed type magnetic release to the existing panel board to the existing panel board complete all as speciifed and directed . Make L&T/Havels/CG
Supply and fix in repairs MNX power contactor 3 Pole, 415 V, Current rating 70 A, 2NO + 2NC having coil voltage 240 Volts complete all as specified and as directed.
Supply & fix in replace MNX power contactor 3 Pole, 415 V, Current rating 110 Amps, 2NO + 2NC having coil voltage 240 Volts complete all as specified and as directed.Make : L&T/Havells/CG.
Supply & fix in replace spare parts kit for 3 pole MNX power contractor 50Amps, 415 volts, with coil rating 230/415 volts, type ML-3 complete all as specified and as directed. Make L&T/Havells/CG.
Supply and fix in replace Bimetalic Overload relays suitable for MNX Power Contactor 50Amps, 415 volts, with coil rating 230/415 volts complete all as specified and as directed. of make L&T/Havells/CG type ML-3.
Supply and fix in replace Bimetalic Overload relays suitable for MNX Power Contactor 70Amps, 415 volts, with coil rating 230/415 volts complete all as specified and as directed. Make L&T/Havells/CG .
Supply and fix in replace from the exisitng panel single phase preventor complete all as specified and as directed.
Supply and fixing of Cast Iron strainer of flange type of latest design of size 200/150 mm complete all as specified and as directed.
Supply and fixing stainless steel rope wire of size 4 mm for existing water level indicator for Overhead tank, Under ground sump of any height/depth complete all as specified and as directed.
Supply and fixing stainless steel float of free size for existing water level indicator for Overhead tank, Under ground sump of any height/depth complete all as specified and as directed.
M & L for painting to existing water level indicator with two coat alongwith proper level marking for overhead tank, Under ground sump of any height/depth complete all as specified and as directed
Supply and fixing float valve of size 25 mm for priming overhead tank complete all as specified and as directed.
Supply and fixing submersible water pump of capacity 1 HP to be installed at UG Sump for priming of Pump complete all as specified and as directed .Make:- Crompton,Kirloskar, CRI
Supply and fixing centrifugal pump of capacity 0.5 HP required to be installed at P-6 foam room for foam topup in foam tank complete all as specified and as directed. Make:- Kirloskar, V guard, Crompton.
Supply and fixing in replace of Priming tank of capacity 500 Ltr at P-1 Pump house complete all as specified and as directed.Make:-Syntex, Plasto.
Labour including tool & plant with any pestiside for cutting grass and bushes on monthly basis for general cleaning of Pump house, AC Plant , Sub Station, Lt Panel, Fire Hydrant including hose reel box, UG Sump, Overhead tank, Valve Pit Chamber and approach and path way for following locations :-. 5 meter sorrounding of building/ pump house and other connected area :- (a) Pump House & AC Plant Buildings Buildings- 7 Nos (b) Substation Building - 6 Nos (c) UG Sump- 05 Nos (d) Over Head Tank- 02 Nos (e) LT Panel - 10 Nos (f) Fire Hydrant and hose reel boxes including path way-62 Nos (g) Valve pit chamber- 20 Nos Note:- The rate of above JOB for duration of 12 month. However the above cleaning will be done on quarterly basis.
SHUBHAM SALES
M/s MM TRADERS
Paragon Electrotechnics
Attar Singh and Sons
M/s Prakash Agencies
M/s Dara Constructions, Pulgaon
M/S JAI BHAWANI CONSTRUCTIONS
Chhabra Enterprises
Bidder Name
Paragon Electrotechnics
Attar Singh and Sons
M/s Dara Constructions, Pulgaon
M/S Maa Durga Constructions,Pulgaon
M/s Prakash Agencies
M/s MM TRADERS
M/S JAI BHAWANI CONSTRUCTIONS
SHUBHAM SALES
Chhabra Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .