Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.4 CrAccepted-Finance | ₹3.4 Cr | L1 | Accepted-Finance L1 |
| 2 | L2₹3.6 Cr+₹12.8 L (3.73%)Accepted-Finance A 41 HIRALAL NAGAR NEAR DIXIT SWEETS SAROJINI NAGAR KANPUR ROAD LUCKNOW UTTAR PRADESH 226008 | LUCKNOW | UTTAR PRADESH | 226008 | ₹3.6 Cr+₹12.8 L (3.73%) | L2 | Accepted-Finance L2 |
| 3 | L3₹3.6 Cr+₹21.6 L (6.32%)Accepted-Finance | ₹3.6 Cr+₹21.6 L (6.32%) | L3 | Accepted-Finance L3 |
| 4 | L4₹3.9 Cr+₹48.9 L (14.3%)Accepted-Finance | ₹3.9 Cr+₹48.9 L (14.3%) | L4 | Accepted-Finance L4 |
| 5 | L5₹4.2 Cr+₹72.8 L (21.3%)Accepted-Finance | ₹4.2 Cr+₹72.8 L (21.3%) | L5 | Accepted-Finance L5 |
Tender Value
₹4.3 Cr
EMD Value
₹8.7 L
Closing Date
29 Nov 2023, 4:00 pmClosed
Executive Engineer,Elect. Division Vijaypur
Office of the Executive Engineer, Electric Diivision Vijaypur, JPDCL Jammu
PROVIDING OF UN-INTERRUPTED DEDICATED POWER SUPPLY TO BSF BOPs (BORDER OUT POSTS) WITHIN THE JURISDICTION OF ELECTRIC DIVISION VIJAYPUR
2023_PDD_236337_1
EDV/ 46 of 2023-2024 Dated 08-11-2023
Open Tender
Electrical Works
Turn-key
180 days
Samba
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,000
Executive Engineer, Electric Division Vijaypur
₹8.7 L
Office of the Executive Engineer, ED-Vijaypur
14 Dec 2023
8 Nov 2023
30 Nov 2023
9 Nov 2023
29 Nov 2023
9 Nov 2023
9 Nov 2023 - 29 Nov 2023
16 Nov 2023
Amount
SCOPE OF WORK FOR LAYING OF HT LINE ON 9 MTR PCC POLES USING ACSR RABBIT CONDUCTOR ( 26.3 Km)
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Erection of 11 Mtr Long PCC Pole ( As per JKPDD's specification) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply Installation, Testing & Commissioning of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Supply Installation, Testing & Commissioningof 11kV Polymeric composite Disc Insulator 12kV,min. failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanised Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of Aluminium Jointing sleeves
Providing and fixing of P G Clamps
Providing of Galvanized Nuts and Bolts
Creation,Testing & Commissioning of 25 KVA Distribution Transformer Sub Station ( 2 No.)
Supply, Installation & commissioning of 11/0.433 KV, 25 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminum Wound) along with LV Cable Box having detachable Aluminum Gland plate including Transportation
Supply, Transportation, Erection of 9 Mtr LongST Poles (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, GI Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminum paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200 A .
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of 25 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing & Fixing of 32/63 (TNP) Amp. with Dis connector Fuse unit
Providing of Earthing of substation --Excavation of earth pit of dia. 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm for connection of transformer body ,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts ,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of cement Bottoming 1:2:4 mix as per REC Standards 0.45 cum/Pole complete Job
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Anti Climbing device with Clamps
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia. GI stranded wire complete
Painting of ST Poles with Red Oxide Paint and Al. Paint (2 Coat Each)
Providing of Galvanized Nuts and Bolts
Scope of works for Creation,Testing & Commissioning of 63 KVA Distribution Transformer Sub Station (3 No.)
Supply, Installation & commissioning of 11/0.433 KV, 63 KVA 3-Phase Distribution Transformer with Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminum Wound) along with LV Cable Box having detachable Aluminum Gland plate including Transportation
Supply, Transportation, Erection of 9 Mtr LongST Poles (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminum paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200 A .
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of 120 mm² - Single Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing & Fixing of Distribution Box for 63 kVA DTR with MCCB for incomer & SFU's for Outgoing Circuits
Providing of Earthing of substation --Excavation of earth pit of dia. 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm for connection of transformer body ,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts ,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of cement Bottoming 1:2:4 mix as per REC Standards 0.45 cum/Pole complete Job
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Barbed Wire for Anti Climbing
Providing & Fixing of Danger Plates with Clamps
Painting of ST Poles with Red Oxide Paint and Al. Paint (2 Coat Each)
Providing & Fixing of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia. GI stranded wire complete
Providing and fixing of P G Clamps
Providing of Galvanized Nuts and Bolts
Sundry items like Al. Lugs, Jumper and Binding Tape
Creation, Testing & commissioning of 100KVA Distribution transformer sub station (2 No)
Supply, Installation testing & commissioning of 11/0.433 KV, 100 KVA 3-Phase Distribution Transformerwith Bi-metallic terminal Connectors, Energy Level: 2, "BIS Marked" (Aluminium Wound) with LV Cable Box having detachable AluminiumGland
Supply, Transportation, Erection of 9 Mtr Long ST Poles (ST410-SP33) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminum paint coated including all necessary Nut & Bolts & Washers etc.
Supply, Installation, Testing & Commissioning of 11 KV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
Supply, Installation, Testing & Commissioning of 11 KV Horn Gap Fuse Set 3 Phase 200 A .
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing & Fixing of 185 mm² - Single Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing & Fixing of Distribution Box for 100 kVA DTR with MCCB for incomer & SFU's for Outgoing Circuits
Providing of Earthing of substation --Excavation of earth pit of dia. 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm for connection of transformer body ,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts ,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing of cement Bottoming 1:2:4 mix as per REC Standards 0.45 cum/Pole complete Job
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Barbed Wire for Anti Climbing
Providing & Fixing of Danger Plates with Clamps
Painting of ST Poles with Red Oxide Paint and Al. Paint (2 Coat Each)
Providing & Fixing of Galvanized Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm),nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia. GI stranded wire complete
Providing and fixing of P G Clamps
Providing of Galvanized Nuts and Bolts
Sundry items like Al. Lugs, Jumper and Binding Tape
INSTALLATION OF CT/PT UNIT ALONG WITH TRIVECTOR METER (9 No)
11KV Pilfer resistant metering cubicle for 3phase 4wire metering system made of MS Sheet steel thickness not less than 2mm duly power coat painted suitable for indoor as well as outdoor as per the site requirement. The cubicle shall be painted through 7-tank process. The External dimensions should be adequate. Panel having two compartments upper Meter Compartment and lower CT/PT compartment. Provided with synthetic or semi synthetic gasket firmly glued to the surface, Dust, weather and Vermin proof and shall comply degree of protection IP 65 booth the chambers having one sided hinged door arrangements. The metering panel shall be provided with two No MS channels of size 100x50 mm on the front and rear sides duly welded and 4 No of lifting hooks. It should be possible to take meter reading manually, through CMRI and computer without opening the LV chamber door.
Single Phase, Single Core, Single Ratio, Epoxy resin Cast Current Transformers suitable for 11KV, copper wound primary type with rated burden 5VA and accuracy class 0.5 or better and conforming to IS2705 (part I & II) amended upto date. ISF shall be upto 5 The CT Ratio shall be 2.5/5 for 25KVA DT , 5/5 for 63KVA DT &7.5/5 for 100KVA DT
11KV/110 V, Three Phase epoxy resin cast PT with rated burden 15VA per phase and accuracy class 0.5 or better and conforming to IS:3155 (part-I&II) amended upto date with proper colour coded identification. PTs shall be of uniform insulating and withstand separate source 23KV PF for one minute
Bus Bar Details: CTs bus bar: 40x6mm copper strip or adequate size PTs bus bar: Copper wire 8 SWG or 30x0.6mm copper flat strip to connect PT terminal or adequate size duly insulated by the monoplast tape
PVC Copper wire flexible multi-strand of required size for secondary connections for CT wiring the mininum wire size shall be 4mm2 (RYB) and for PT wiring minimum wire size shall be 2.5mm2 (RYB)
Copper Lugs preferably ring type duly crimped for termination of wires and tape
Groundings bus of minimum 40mm copper, 25cm long fixed to the unit in HV Chamber. The CTs, PT meter and 11KV Cable sheath shall be grounded to the bus through grounding wire (green) of min size 10mm2
3PH 3wire HT CT/PT operated fully static Smart Tri Vector Energy Meters DLMS Complaint Category "C' with RS232 port for modern compatibility. 11KV/11OV, Ph-Ph (3P, 3W) meters for measurement of different electrical parameters including Active Energy (Kwh/Mwh), Reactive Energy (KVArh/MVArh) Apparent Energy (KVAh/MVAh) etc. (Make L&T, Secure, ABB)
Independent flexible PVC pipes for CT wiring and PT wiring of appropriate size from HT compartment to meter compartment
Pedestal made out of MS Channel of size 75x40 mm or angle iron of size 65x65x5mm, duly painted as per site requirement for mounting of metering panel including concrete foundation wherever required including cost of nuts and bolts
3Core 11KV Aluminium Cable XLPE armoured 35mm2 including cost of clamp for its fixing where ever required.
Cable termination kits suitable for 3x35mm2 XLPE Cable (indoor/Outdoor)
Earthing 40mm GI Pipe or 20 MM GI Rod, 2.5 mtr for metering unit. Earthing. Of metering cubicle through two No 25x5 mm flat iron
ERECTION & COMMISSIONING OF ISOLATION POINT/TAPPING POINT (35 No.)
Supply, Transportation, Erection of 9 Mtr Long PCC Poles (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply ,Fabrication & Fixing of GI Channel Iron, Cross arm GI, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Supply ,Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Supply, Installation, Testing & Commissioning of 11 KV GO AB Switch, 3-phase, 3-pole, 400 Amp
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip(2 nos for poles & ino. For G O Switch
Providing of Stone Pad 300 mmx300mmx75mm
Providing and fixing of P G Clamps
Providing of Galvanized Nuts and Bolts
THICKENING OF 11 KV LINES FROM ACSR WEASEL TO ASCR RABBIT CONDUCTOR (36.3 Km)
Supply, Laying & Stringing of ACSR Rabbit Conductor through insulators including proper binding & twisting with soft Aluminium Wire for thickening from Squirrel to weasel conductor (LT network)
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 5kN,Lighting Impulse 75kV Positive and 80kV Negative,creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positiveand 80kV Negative, creepage distance 320mm
Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip(2 nos for poles & ino. For G O Switch
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Providing and fixing of Aluminium Jointing sleeves
Providing and fixing of PG Clamps
Providing of Stone Pad (300mmx300mmx75mm)
Providing of Galvanized Nuts and Bolts
G.V Cross arms woith Top Bracket inlcuding Clamps
INSERTION OF 9 Mtr.PCC POLES IN LONGER SPAN IN HT LINE (107 No.)
Supply, Transportation, Erection of 9 Mtr Long PCC Pole (WL-300 KG) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of 11 KV Pin Insulator with Pins (Polymer/Porcelain) 10 KN
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminum paint coated including all necessary Nut & Bolts & Washers etc.
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad (300mmx300mmx75mm)
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Providing of Galvanized Nuts and Bolts
INSERTION OF 11 Mtr.PCC POLES IN LONGER SPAN IN HT LINE (25 No.)
Supply, Transportation, Erection of 11 Mtr Long PCC Pole (As per JKPDD's specification) including excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Providing & Fixing of 11 KV Pin Insulator with Pins (Polymer/Porcelain) 10 KN
Supply, Transportation, Fabrication & Fixing of GI Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminum paint coated including all necessary Nut & Bolts & Washers etc.
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip
Providing of Stone Pad (300mmx300mmx75mm)
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Providing of Galvanized Nuts and Bolts
IMPROVEMENT OF EXISTING SUB STATIONS (100 KVA -8 Nos, 63 KVA-2 Nos & 25 KVA-3 Nos)
Supply, Installation, Testing & Commissioning of 11 kV Horn Gap Fuse Set 3 Phase 200A
Supply & Fixing of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
Providing of Earthing of substation --Excavation of earth pit ofdia 650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wallthickness & length 2.5 mtr long as Per IS 1239.GIStrip for neutral earthing of size 25 mm x 3 mm forconnection of transformer body,G.O Set &lightening arrestor as per IS 2629/85, GI nuts &bolts,refilled with earth enhancement materialsand earth Chamber made of brick masonary withRCC slab cover.(3 at each S/Stn)
Providing & Fixing of 25 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing & Fixing of 95 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Providing & Fixing of 185 mm² Single-Core Cable,1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
Alliance Transcon Pvt. Ltd.
CEEKAY EPC PROJECTS PRIVATE LIMITED
M/s M. S. CONSTRUCTIONS
COUNTRY CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .