Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | Admitted-Finance |
| 2 | Admitted-Finance REVENUE WARD 8 8 2 220 GANDLA STREET SULLURU SULLURPET NELLORE ANDHRA PRADESH 524121 | SPSR NELLORE | ANDHRA PRADESH | 524121 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical not prequalified |
Tender Value
₹24.2 L
EMD Value
₹48,400
Closing Date
14 Feb 2022, 3:00 pmClosed
Chief Mechanical Engineer
VOC Port Trust Tuticorin
Supply, Installation and Commissioning of Thermoplastic Polycarbonate Distribution Panels at Administrative Building.
2022_VOCPT_103066_1
MEE/SE2E1/ELEC/63137/2022
Open Tender
Electrical Works
Works
90 days
Tuticorin
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
₹48,400
Yes
8 Apr 2022
25 Jan 2022
15 Feb 2022
25 Jan 2022
14 Feb 2022
25 Jan 2022
Electrical Items :
Supply, installation, Testing and commissioning of Thermoplastic polycarbonate Main distribution panel with back & bottom frame arrangement including switchgears, Bus bar chambers with copper bus bars, Meters, interconnection wiring with suitable wire/cable/bus arrangements & links, Rotary handle arrangement for MCCBs, Cable chambers, Required metering sets, indication lamp sets, Termination of existing cable, Civil works for erection (base concrete and back side bolt arrangement if any as per site condition and as per the specification enclosed (complete set) with the following arrangements – Complete set. Also the old panel shall be removed and handed over to Port stores Incoming : 400A FP, 36KA MCCB – 2 Nos. MFM with CT and RYB indication – 2 sets Outgoing : 1. 400A FP,36KA MCCB – 1 No. 2. 200A FP,36KA MCCB – 5 Nos 3. 125A, 25KA FP MCCB – 5 Nos 4. MFM with CT and RYB indication – 1 set in 1 No.200A O/G feeder 5. Required terminal blocks
Supply, installation, Testing and commissioning of Thermoplastic polycarbonate Stabilizer distribution panel with back & bottom frame arrangement including switchgears, Bus bar chambers with copper bus bars, Meters, interconnection wiring with suitable wire/cable/bus arrangements & links, Rotary handle arrangement for MCCBs, Cable chambers, required o/g wire/cable interconnection with channel box arrangements, Required metering sets, indication lamp sets, Termination of existing cable, Civil works for erection (base concrete and back side bolt arrangement if any as per site condition and as per the specification enclosed (complete set) with the following arrangements – Complete set Incoming : 400A FP, Change over – 2 Nos. MFM with CT and RYB indication – 2 sets Outgoing : 1. 250A FP,36KA MCCB – 2 Nos 2. 63A, 4P,10KA MCB – 8 Nos 3. 32A, 2P, 10KA MCB – 12 Nos 4. Required terminal blocks
Supply, installation, Testing and commissioning of Thermoplastic polycarbonate UPS supply distribution panel with back & bottom frame arrangement including switchgears, Bus bar chambers with copper bus bars, Meters, interconnection wiring with suitable wire/cable/bus arrangements & links, Rotary handle arrangement for MCCBs, Cable chambers, required o/g wire/cable interconnection with channel box arrangements, Required metering sets, indication lamp sets, Termination of existing cable, Civil works for erection (base concrete and back side bolt arrangement if any as per site condition and as per the specification enclosed (complete set) with the following arrangements – Complete set Incoming : 160A FP, Change over – 2 Nos. MFM with CT and RYB indication – 2 sets Outgoing : 1. 63A, 4P,10KA MCB – 12 Nos 2. 32A, 2P, 10KA MCB – 10 Nos Required terminal blocks
Supply, installation, Testing and commissioning of Thermoplastic polycarbonate Change over distribution panel with back & bottom frame arrangement as per site requirement including switchgears, interconnection with suitable cable/bus arrangements & links, Rotary handle arrangement for COB, Cable chambers, Required indication lamp sets, Termination of existing cable, Civil works for erection (base concrete and back side bolt arrangement if any as per site condition and as per the specification enclosed (complete set) with the following arrangements – Complete set 400A Change over switch – 1 set RYB Indication lamps – 3 sets
Supply, installation, Testing and commissioning of outdoor Thermoplastic polycarbonate SS 2 Main distribution panel with back & bottom frame arrangement including switchgears, Bus bar chambers with copper bus bars, Meters, interconnection wiring with suitable wire/cable/bus arrangements & links, Rotary handle arrangement for MCCBs, Cable chambers, Required metering sets, indication lamp sets, Termination of existing cable, Civil works for floor mounting erection (base concrete and back side frame bolt arrangement if any as per site condition and as per the specification enclosed (complete set) with the following arrangements – Complete set. Also the old panel shall be removed and handed over to Port stores Incoming : 630A FP, 36KA MCCB – 1 No. MFM with CT and RYB indication – 1 sets Outgoing : 1. 630A FP, 36KA MCCB – 1 No. 2. 250A, FP,36KA MCCB – 2 Nos. 3. 250A TP,36KA MCCB – 2 Nos 4. 125A, 25KA FP MCCB – 4 Nos 5. MFM with CT and RYB indication – 1 set in 1 No.630A feeder 6. RYB lamp arrangement in all O/Gs. 7. Required terminal blocks
Supply, installation, Testing and commissioning of Thermoplastic polycarbonate distribution panel with back & bottom frame arrangement including switchgears, Bus bar chambers with copper bus bars, Meters, interconnection wiring with suitable wire/cable/bus arrangements & links, Rotary handle arrangement for MCCBs, Cable chambers, required o/g wire/cable interconnection with channel box arrangements, Required metering sets, indication lamp sets, Termination of existing cable, Civil works for erection (base concrete and back side bolt arrangement if any as per site condition and as per the specification enclosed (complete set) with the following arrangements – Complete set. Also the old panel shall be removed and handed over to Port stores Incoming : 200 FP, 36KA MCCB – 1 No. MFM with CT and RYB indication – 1 sets Outgoing : 1. 63A, 4P,10KA MCB – 3 Nos 2. 63A, 2P,10KA MCB – 3 Nos 3. 32A, 2P, 10KA MCB – 6 Nos Required terminal blocks
Supply & providing of 300Sqmm LTUG XLPE straight through joint kit including labour charges for positioning, relaying, etc
Supply & laying of 300Sqmm LTUG ISI mark XLPE armored cable including excavation, removal of debris and other works as per site requirement
Supply & providing of 95 Sqmm LTUG XLPE straight through joint kit including labour charges for positioning, relaying, etc
Supply & laying of 95Sqmm LTUG ISI mark XLPE armored cable including excavation, removal of debris and other works as per site requirement
Supply & providing floor mat for the control room as per BIS/CEA regulation for LT switchgear operation(Floor size : 5.2M X 3.4M approx)
M/s. CHANDRA REDDY ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .