Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance WARD 18 PLOT NO 153 PHASE II HOUSING COLONY NEAR ROTARY EYE HOSPITAL UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹15,760
Closing Date
15 Jul 2022, 4:00 pmClosed
Executive Engineer
Electric Division JPDCL Udhampur
Erection of substation and poles
2022_PDD_175840_1
ED/UDH/36 of 2022-23, dt. 24-06-2022
Open Tender
Electrical Works
Turn-key
90 days
At Satrari and Chaned Sumwal in District Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
Executive Engineer Electric Division JPDCL
₹15,760
8 Aug 2022
25 Jun 2022
18 Jul 2022
25 Jun 2022
15 Jul 2022
25 Jun 2022
25 Jun 2022 - 30 Jun 2022
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning of the work "Installation of 63 KVA Transformer W.No 5 & 7 at Satrari" by way of Erection of 11 KV line on 9 mtr. PCC poles, ACSR Weasel Conductor at pyt. Satrari
9 mtr. Long PCC Pole (WL-300Kg)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Angle for braces
0.03 ACSR Weasel conductor
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
11KV Pin Insulator (Polymeric) with Pins (12kv, 5KN) Creepage Distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti climbing device with clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning of the work"Installtion of 63 KVA Transformer W.No 5 & 7 at Satrari" by way of creation of 63 KVA Transformer
11/0.43 KV, 63 KVA 3-phase Distribution Transormer with Bimetallic Terminal connectors Energy Level-2 (Aluminium wound and with LV Cable Box having detachable Aluminium Gland plate
120mm2 Single Phase cable, 1.1 KV Grade, PVC insulated stranded conductor FRLS Type
Gapless Surge Arrestor, 9 KV, 10 KA, LA with polymer housing,Stn Type
11 KV GO Switch 3-Phase,3-pole, 200 AMP,vertical
11 KV Horn Gap Fuse Set 3 Phase 200A
9 mtr. Long Pole (ST-410 SP33)
11KV Disc Insulators (Polymeric 45KN ) creepage distance 320 mm with tension fittings
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts
LT Distribution Box for 63 KVA DTR with MCCB for incomer & Switch Fuse units for outgoing Cricuits
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Design, Supply, Transportation, Carriage, Erection, Testing and Commissioning for the work of "Instalation of transformer upto 63 KVA W.No. and 3 requirement of poles with wire W.No.7" by way of Upgradation of Transformer from 25 KVA to 63 KVA, W.No 3 at Chaned pyt. Sumwal
11/0.43 KV, 63 KVA 3-phase Distribution Transormer with Bimetallic Terminal connectors Energy Level-2 (Aluminium wound upto 200 KVA, copper wound for 250 KVA or higher KVA ratings) and with LV Cable Box having detachable Aluminium Gland plate
0.03 ACSR Conductor Weasel.
Flat for Mukki Clamps
120mm2 Single Phase cable, 1.1 KV Grade, PVC unarmed stranded conductor FRLS Type
GI Channe/Angle/Flat of sizes including clamps
LT Distribution Box for 63 KVA DTR with MCCB for incomer & Switch Fuse units for outgoing Cricuits
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
9 mtr. Long Pole (ST-410 SP33)
Galvanized Nuts and Bolts
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
M R ENGINEERS & TRADERS
KULBUSHAN KUMAR
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .