Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹22.2 L+₹89,342 (4.18%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹23.7 L+₹2.4 L (11.2%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹24.6 L+₹3.2 L (15.2%)Rejected-Finance | L4 | Rejected-Finance L4 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
17 Mar 2022, 6:00 pmClosed
GE Jaipur
Garrison Engineer, Military Engineer Services, Khatipura road, Jaipur 302012
REPAIR/MAINT OF EXTERNAL ELECTRIC SUPPLY, WATER SUPPLY AND MISC E/M WORKS AT MH JAIPUR
2022_MES_509287_1
GE/J-60/2021-22
Open Tender
Civil Works
Item Rate
270 days
Jaipur
As per NIT
5 documents required · 5 mandatory
₹500
GE Jaipur
₹50,000
Yes
29 Mar 2022
19 Feb 2022
19 Mar 2022
19 Feb 2022
17 Mar 2022
4 Mar 2022
19 Feb 2022 - 3 Mar 2022
Amount
Excavation in soft / loose soil in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out complete.
Returning filling with earth obtained from excavation including spreading watering and consolidation in layers not exceeding 25 cms thick complete.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5 m above the starting point complete.
S&F Steel tubes ISI marked light grade galvanised with all fittings fixed to walls / poles / laid in road crossing etc as required of following sizes:-
(a) 40 mm bore
(b) 80 mm bore
M&L for steel tubular swaged pole 8.5m long type 410 SP-22 with cast iron or welded MS base plate including nuts / bolts / washers etc conforming to IS-2713 (Part I to III) of 1980 and comprising of following:- (a) Excavation in post holes in any type of soil not exceeding 0.5 cum each, getting out, returning filling in and ramming earth in layers not exceeding 25 cm watering and disposal of surplus soil to a distance not exceeding 50 m and making good surface. (b) PCC (1:4:8) type D2 using 40 mm graded stone aggregate in base (0.60 m dia x 0.15 m height). (c) PCC (1:3:6) type C2 using 40 mm graded stone aggregate in foundation filling (0.60 m dia x 1.5 m height). (d) PCC (1:2:4) type C2 using 40 mm graded stone aggregate in coping (0.6 m dia x 0.45 m height). (e) Pole cap 0.30 m long externally fitted on pole top duly welded with a light grade ISI marked 40 mm GI pipe bracket 1.5 m long for mounting street light fitting. (f) Painting with aluminium paint one under coat, one finishing coat over a coat of red oxide primer and making alternate colour bands of black & white colours in 30 cms width upto a height of 1.5 m from pole coping with synthetic enamelled paint complete.
Supplying, laying or fixing on wall through proper clamping or passing through pipe, testing and commissioning 1100 volts grade ISI marked XLPE insulated and PVC sheathed steel tape / wire armoured underground stranded aluminium conductor cable of following sizes:- (a) 10 sqmm 2 core
(b) 16 sqmm 4 core
(c) 25 sqmm 4 core
(d) 50 sqmm 3.5 core
(e) 70 sqmm 3.5 core
(f) 95 sqmm 3.5 core
(g) 120 sqmm 3.5 core
(h) 300 sqmm 3.5 core
(I) 400 SQ MM 3.5 Core
M&L for demolition of PCC in foundation of concrete pole including taking out concrete poles / strut of any size and removing broken PCC outside cantonment area to a distance beyond 5 km but not exceeding 15 m and depositing at a level not exceeding 1.5 m above the starting point complete.
M&L for cable jointing kit for upto 1.1 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following size :-
10 sqmm 2 core
16 sqmm 4 core
25 sqmm 4 core to 50 sqmm 3.5 core
70 to 120 sqmm 3.5 core
Supplying and making in renewal straight through joint heat shrinkable type for 1.1 KV grade XLPE cable of following sizes:- (Make - Denson / M-Seal / 3M as approved)
(a) 25 sqmm 4 core to 50 sqmm 3.5 core.
(b) 70 to 150 sqmm 3.5 core.
M&L for sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying including gently punning around cable complete all as specified in SSR Part-I and directed.
Supplying and laying old size bricks, common burnt clay building bricks sub class 'B' designation 75 laid in trenches over sand for cable protection complete.
Taking out old u/s XLPE cables of following sizes:-
(a) 10 sqmm 2 core, 1.1 KV
(b) 16 to 25 sqmm 4 core, 1.1 KV
(c) 50 to 120 sqmm 3.5 core, 1.1 KV
(d) 300 to 400 sqmm 3.5 core, 1.1 KV
Taking down old u/s GI protection pipe of sizes 40 to 80 mm bore.
M&L for horizontal boring through road / path / floor for passing UG cables as required.
M&L for filtration / dehydration of insulating oil of transformer in position to achieve dielectric strength 50 KV or above (when tested with 2.5 mm gap electrode) complete.
S&F in repair MCCB 125 amp, 4 pole, 16 KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 420016 or equivalent as approved by GE
S&F in repair MCCB 160 amp, 4 pole, 16 KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 420017 or equivalent as approved by GE
S&F in repair MCCB 250 amp, 4 pole, 24 KA (Ics=100% Icu) thermally adjustable between 70% to 100% with spreader links on both sides as per Legrand cat ref no. 420219 or equivalent as approved by GE
S& F in repair integral LED flood light 100 W 3000 K (WW) warm white with driver inside a PDC housing philips Cat part No CVP 182 LED 100 W CW FG S1 PSU GR or equivalent as approved by GE
M&L for of bus bar chamber pedestal type of size 75 cm x 60 cm x 40 cm out door dust & vermin proof front opening made out of 2.0mm thick MS sheet duly painted and consisting with aluminium bus bar 3 phase and neutral 4 Nos 400 Amp fixed on insulators and one MCCB TPN 200 Amp, 25 KA rupturing capacity including necessary fixed in PCC 1:3:6 using 20 mm graded stone aggregate including danger plate etc complete.
Renewal of MCCB 63 amp, 4 pole, Icu 16 KA (Ics=100% Icu), electronic release and adjustable between 40% to 100% with spreader links on both sides as per Legrand cat ref no. 420013 or equivalent as approved by GE
Renewal of MCCB 400 amp, 4 pole, Icu 36 KA (Ics=100% Icu), electronic release and adjustable between 40% to 100% with spreader links on both sides as per Legrand cat ref no. 422063 or equivalent as approved by GE
M&L for pipe in pipe chemical earthing with GI pipe electrode 3.0 m long having outer pipe dia 80 mm & inner pipe dia 50 mm duly filled with highly conductive and anti corrosive compound of required quantity having chemical composition Bentonite 40%, copper sulphate 20%, Gypsom 5%, Graphite 10%, Alum 5%, Zinc sulphate 10%, Aluminium sulphate 10% burried in ground by digging a bore of 150 mm dia surrounded by soil friendly backfill compound non soluble in water including connection with galvanised earth strip 32 x 6 mm, making PCC pit of size 0.3 m x 0.3 m x 0.3 m (inner size) in mix 1:3:6 type C1 with RCC 1:2:4 type B-1, 40 mm thick cover reinforced with 8 mm dia MS bars 3 Nos both ways with lifting hook made out of 8 mm dia bar and testing on completion to achieve value not more than 2.0 ohm complete. (Note - GI strip size 32x6 mm upto 7.5 m included in the item).
Renewal of transformer breather assembly oil seal type made of heavy duty transparent plastic body having top & bottom cover made of aluminium or mild steel of capacity 500 grams filled with silica gel complete.
M&L for topping up of deficient oil level of transformers with filtered and dehydrated transformer oil (conforming to IS: 335) and to withstand dielectric strength 60 KV or above (when tested with 2.5 mm gap electrode) complete. Make - Savita / Powerlink / Poweroil or equivalent as approved by GE
S&F in repair HV brass set stem of 12 KV grade suitable for transformer of capacitie 200 KVA to 400 KVA as required.
S&F in repair LV brass set stem of 1.1 KV grade suitable for transformer of capacities 200 KVA to 400 KVA as required.
Dehydration / Filtration of transformer Oil of existing transformer install at site with portable plant to improve the dielectric strength 40 to 60 KV during filling after initial filtration including testing of dielectric strength after dehydration at site.
Taking down any type HPSV fittings and Supply, installation, testing and commissioning of integral driver LED street light with a nominal system lumen output of 7200 lumens and a minimum system efficacy of 90 lumen/watt. The luminaire shall have rated system lifetime of 50,000 burning hours before reaching at L70. The luminaire should have cool white colour temperature (CCT > 5000K) and a CRI >70. The luminaire shall meet IP 66 rating & IK05 rating with THD < 20% and PF > 0.9. The luminaire housing should be made of pressure die cast aluminium with a flat glass optical cover. The total power consumption should not exceed 72W including driver. Make - Philips Greenline cat ref BRP410 LED CW 072 MR FG S1 PSU GR or equivalent as approved by GE
Renewal of street light bracket made of GI pipe light grade bend in shape of 40 mm dia, 1.5 m long and clamped with 2 pairs of 40 x 6 mm flat iron clamps, nuts / bolts / washers & painted with 2 coats of aluminium paint over a coat of red oxide primer on clamps complete.
M&L for painting of street light swaged poles 8.5 m / 9.0 long including street light brackets/clamps etc with best quality aluminium paint, making alternate black & white colour bands of 30 cms width upto a height of 1.5 m from pole coping with synthetic enamelled paint and writing pole numbers in black colour on yellow base complete.
S&F thermoplastic, IP65 cable junction box of size 200 x 160 x 98 mm with metric knockouts on all sides for cable entry or Secure duly fitted with followings:- (a) DIN Rail (35 mm) - 1 No (b) ELMEX or equivalent make connector of 10 sqmm - 4 Nos (c) ELMEX or equivalent make end plate - 1 No (d) ELMEX or equivalent make end clamps - 2 Nos (e) MCB SP 6 amp, 10 KA, 'C' series.
Supplying, installation, testing & commissioning in renewal CPRI approved outdoor cubical type MV feeder pillar box suitable for 415V, 3 phase, 4 wire 50 Hz, AC supply system with short circuit withstand capacity 35 MVA for 1 second, IP 54 protection, fabricated in compartmentalized design from stainless steel sheet (SS 316) 2.0 mm thick totally enclosed, dust, weather & vermin proof, having TPN copper bus bars of rating 1.5 times that of controlling MCCB supported on 'F' class SMC insulators, bottom base channel of MS section not less than 75 mm x 40 mm x 5 mm thick, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos earth stud, solid connections from main bus bar to switchgears with required size copper bus bars and control wiring with minimum 1.5 sqmm PVC insulated copper conductor cable, cable alleys, cable gland plates including digital multi functional meter to measure voltage, current, PF & frequency and mounted on by making suitable PCC foundation, necessary inter connection including following controls :- (Location - MH near 200 KVA transformer) Incoming:- One number MCCB 320 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz with electronic release adjustable between 40% to 100% against overload setting as per Legrand cat ref no. 422062 or equivalent as approved by GE. Outgoing:- (i) Two numbers MCCB 100 amp, 3 pole, Ics 16 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420005 or equivalent as approved by GE. (ii) Four numbers MCCB 63 amp, 3 pole, Ics 16 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420003 or equivalent as approved by GE.
Ditto as per item No 32 above but with following controls:- Incoming:- One number MCCB 160 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz with Electronic release adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420347 or equivalent as approved by GE Outgoing:- Four numbers MCCB 63amp, 3 pole, Ics 25 KA, 415 volts, 50 Hz, thermally adjustable between 70% to 100% against overload setting as per Legrand cat ref no. 420003 or equivalent as approved by GE
Supply & Fix in replacement of single type fire hydrant landing valve type A Single headed outlet of 63mm dia incl rubber gasket, nut & bolts complete all as specified and directed.
Supply & Fix in replacement of double type fire hydrant landing valve type A Double headed outlet of 63mm dia incl rubber gasket, nut & bolts complete all as specified and directed.
Supply and Fix in replacement of Branch pipe gun metal 63mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short all as specified and directed
Supply and fix in replacement of 63mm dia 15 mtr long hose confirming to IS 636 complete with male and female coupling complete all as specified and directed. Note - Contractor should visit the site before quating the tender and any other misc items required for complete the job are deemed to be incl in to rate quated by contractor.
Supply and Fix in replacement of Hose box Out door type of suitable size made out of minimum 1mm thick MS sheet with double door with 4mm thick plain sheet glasses and door frame made of 1.2 mm thick MS sheet painted fire red outside and brilliant white inside complete fixing nut bolts etc all as specified and directed
Supply and Fix in replacement cast iron Foot valve of size 80mm dia with rubber gasket and nut, bolts complete all as specified and directed .
Discoupling/ Disconnecting and taking down carefully Electric driven pumping set of capacity 40 HP (motor and pump) from foundation after disconnectingsuction and discharge line taking down from foundation bolt dismantling from base channel and transporting to civil workshop for repair. Strip opening all parts , cleaning overhauling comprising of repairs/replacement of repairable parts , such as taking out impeller shaft assembly complete taking out bearing housing , gland bush and other connected items including balancing of impeller shaft , impeller and including lathe work a required , reassembling the complete pumping set , reinstalling , mounting and fixing on base channel on existing foundation and coupling properly to existing motor with proper balancing and alingment including recoupling of suction and discharge line , commissioning and testing on full load all as specified and directed. Note for item (i) New spare parts will be measured and paid separately under relevent items (ii) Rates are deemed to be included for replacement of gaskets, packing with bearing grease, glands with graphite packing , nuts bolts , washers etc. (iii) Cost of transportation shall be deemed to be included in the rate quoted for these items.
M&L for replacement of MS shaft suitable for pump of capacity 40 HP for Becon pump type DRC-150/150.
M&L for replacement of Impeller bush brass suitable for pump of capacity 40 HP for Becon pump type DRC-150/150.
M&L for replacement of Brass Impeller suitable for pump of capacity 40 HP.
M&L for replacement of Bearing housing with bearing of existing size suitable for pump of capacity 40 HP for Becon pump type DRC-150/150.
M&L for replacement of Gasket set suitable suitable for pump of capacity 40 HP.
M&L for replacement of Gland plates MS (As per sample) suitable for pump of capacity 40 HP
M&L for replacement of Gland bush (As per sample) suitable for pump of capacity 40 HP
M&L for replacement of MS Coupling suitable for pump of capacity 40 HP.
General servicing of DG Set 25 KVA (Make - Kirloskar including adjustment of tappet cover & replacement of gasket and following spares as per existing make :-
(a) Diesel fitter
(b) Lubricating oil filter
(c) Radiator hose pipe set
(d) Fan belt.
(e) Air filter element
General servicing of DG Set 30 KVA (Make - Kirloskar including adjustment of tappet cover & replacement of gasket and following spares as per existing make :-
(a) Diesel fitter
(b) Lubricating oil filter
(c) Radiator hose pipe set
(d) Fan belt.
(e) Air filter element
General servicing of DG Set 62.5 KVA (Make - Kirloskar including adjustment of tappet cover & replacement of gasket and following spares as per existing make :-
(a) Diesel fitter
(b) Lubricating oil filter
(c) Radiator hose pipe set
(d) Fan belt.
(e) Air filter element
General servicing of DG Set 160 KVA (Make - Kirloskar) including adjustment of tappet cover & replacement of gasket and following spares as per existing make:-
(a) Diesel filter
(b) Lubricating oil filter
(c ) Radiator hose pipe
(d) Fan belt
(e) Air filter element
General servicing of DG Set 250 KVA (Make - Kirloskar) including adjustment of tappet cover & replacement of gasket and following spares as per existing make:-
(a) Diesel filter
(b) Lubricating oil filter
(c) Radiator hose pipe set
(d) Fan belt
(e) Carbon brush
General servicing of DG Set 250 KVA (Make - Cummins) including adjustment of tappet cover & replacement of gasket and following spares as per existing make:-
(a) Diesel filter
(b) Lubricating oil filter
(c) Radiator hose pipe set
(d) Fan belt
(e) Carbon brush
Supply and filling in renewal or in topping up engine oil SAE grade 20W-40 for DG Set of capacity 62.5 to 250 KVA as required.
M&L for replacement of water coolent in radiator of DG Set TVS Girling/volvo line or equivelent make as approved.
Supplying and fixing in renewal sealed maintenance free lead acid battery 12 volt, 150 AH for DG set as required.
Supplying and fixing in renewal sealed maintenance free lead acid battery 12 volt, 180 AH for DG set as required.
Schedule of Credit
SHREE BHAGWATI ENTERPRISES
M/S Sheeba Enterprises
M/S TRADE LINKERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .