Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-Finance | L1 | Accepted-Finance Being Lowest | |
| 2 | L2₹38.8 L+₹6.0 L (18.4%)Accepted-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Accepted-Finance Not being lowest | |
| 3 | L3₹39.3 L+₹6.6 L (20.1%)Accepted-Finance | L3 | Accepted-Finance Not being lowest | |
| 4 | L4₹39.6 L+₹6.9 L (20.9%)Accepted-Finance | L4 | Accepted-Finance Not being lowest | |
| 5 | L5₹54.5 L+₹21.7 L (66.4%)Accepted-Finance | L5 | Accepted-Finance Not being lowest |
| Sl No | Description | Qty | Unit | a.k constructions L1 | M/S ANIL KUMAR L2 | Pall Associates L3 | PARMAR ENTERPRISES L4 | J V ENGINEERS / JAI SINGH L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down old unsv MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. | 153 | Each | 2 ₹306 Lowest | 2 ₹306 Lowest | 5 ₹765 | 19 ₹2,907 | 9 ₹1,377 |
| 2.00 | Taking down old submain wiring of any size, including coduit and make from the site complete all as specified. | 4,650 | RM | 2 ₹9,300 | 1 ₹4,650 Lowest | 5 ₹23,250 | 9 ₹41,850 | 5 ₹23,250 |
| 3.00 | Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified. | 176 | Each | 2 ₹352 Lowest | 5 ₹880 | 5 ₹880 | 9 ₹1,584 | 5 ₹880 |
| 4.00 | Taking down old unsv LT panel of any size & capacity complete all as specified and directed. | 35 | Each | 120 ₹4,200 | 149 ₹5,215 | 50 ₹1,750 | 199 ₹6,965 | 5 ₹175 Lowest |
| 5.00 | M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable 4.0 Sqmm in and including in and including concealed / surface PVC conduits as suitable of site (Medium grade) not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 4.0 Sqmm size stranded conductor as earthwire.
Note for item No.05, 06 & 07 : two run of main wire PVC insulated FRLS 1100 volts unsheathed stranded copper conductor and one run of earth wire with one run of PVC conduit will be measured and paid in one length. | 710 | RM | 99 ₹70,290 | 99 ₹70,290 | 120 ₹85,200 | 129 ₹91,590 | 75 ₹53,250 Lowest |
| 6.00 | M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including concealed / surface PVC conduits as suitable of site (Medium grade) of not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 6.0 Sqmm size stranded conductor as earthwire. | 3,540 | RM | 179 ₹6,33,660 | 199 ₹7,04,460 | 150 ₹5,31,000 | 149 ₹5,27,460 | 119 ₹4,21,260 Lowest |
| 7.00 | M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable10 Sqmm in and including concealed / surface PVC conduits as suitable of site (Medium grade) of not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 10 Sqmm size stranded conductor as earthwire. | 400 | RM | 265 ₹1,06,000 | 255 ₹1,02,000 | 220 ₹88,000 Lowest | 229 ₹91,600 | 249 ₹99,600 |
| 8.00 | Supply and fix 35/40 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie > 100lm/W with a life class of 25,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 140-270V, THD<20%, High and low protection along with a surge protection of 2.5 KV including provision of suitable size of GI light grade pipe 1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete. | 110 | Each | 950 ₹1,04,500 | 1,079 ₹1,18,690 | 900 ₹99,000 | 1,299 ₹1,42,890 | 899 ₹98,890 Lowest |
| 9.00 | Supply and fix MCB DB SPN 8 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complet
Note for item No 09, 10 & 13 :- Rates are inclusive of cutting / chases for mounting DB box concealed in wall and making good to the disturbed surfaces with existing colour coding by proper plastering work all well as OBD / colour wash / white wash and wall putty where ever is required all as specified directed by Engineer -in-Charge. | 38 | Each | 1,050 ₹39,900 | 1,099 ₹41,762 | 1,000 ₹38,000 | 1,099 ₹41,762 | 999 ₹37,962 Lowest |
| 10.00 | Supply and fix MCB DB SPN 12 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complet. | 20 | Each | 1,150 ₹23,000 Lowest | 1,319 ₹26,380 | 1,200 ₹24,000 | 1,299 ₹25,980 | 1,199 ₹23,980 |
Tender Value
₹50.0 L
EMD Value
₹99,980
Closing Date
9 Apr 2026, 6:00 pmClosed
LT COL MANISH E WASNIK
GE (CENTRAL) DELHI CANTT-10
8825/TOKEN-140/2025-26
2026_MES_756096_1
GE/TOKEN-140/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (CENTRAL) DELHI CANTT-10
AS PER NIT
9 documents required · 9 mandatory
₹500
Yes
GE (CENTRAL) DELHI CANTT-10
₹99,980
Yes
27 Apr 2026
12 Mar 2026
11 Apr 2026
12 Mar 2026
9 Apr 2026
26 Mar 2026
Taking down old unsv MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed.
Taking down old submain wiring of any size, including coduit and make from the site complete all as specified.
Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified.
Taking down old unsv LT panel of any size & capacity complete all as specified and directed.
M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable 4.0 Sqmm in and including in and including concealed / surface PVC conduits as suitable of site (Medium grade) not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 4.0 Sqmm size stranded conductor as earthwire. Note for item No.05, 06 & 07 : two run of main wire PVC insulated FRLS 1100 volts unsheathed stranded copper conductor and one run of earth wire with one run of PVC conduit will be measured and paid in one length.
M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including concealed / surface PVC conduits as suitable of site (Medium grade) of not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 6.0 Sqmm size stranded conductor as earthwire.
M&L for submain wiring with two single core PVC insulated FRLSH 1100 Volts unseathed stranded copper conductor cable10 Sqmm in and including concealed / surface PVC conduits as suitable of site (Medium grade) of not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 10 Sqmm size stranded conductor as earthwire.
Supply and fix 35/40 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie > 100lm/W with a life class of 25,000 burning hours at L70. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 140-270V, THD<20%, High and low protection along with a surge protection of 2.5 KV including provision of suitable size of GI light grade pipe 1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete.
Supply and fix MCB DB SPN 8 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complet Note for item No 09, 10 & 13 :- Rates are inclusive of cutting / chases for mounting DB box concealed in wall and making good to the disturbed surfaces with existing colour coding by proper plastering work all well as OBD / colour wash / white wash and wall putty where ever is required all as specified directed by Engineer -in-Charge.
Supply and fix MCB DB SPN 12 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar ,neutral link earth link complet.
M&L MCB SPN 40 Amp "C " curve all as directed.
M&L MCB SP 6 to 32 Amp "C" curve all as directed.
Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-30 protection), mechanical impact strength IK - 07, with cement spill protector double door fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified Note :- MCCB & MCB will be measured & paid separately Note :
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to VTPN DB or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to VTPN DB or any other indicated situation for loop earthing etc 25 x 4 mm dia galvanised irin strip complete all as specified.
Supply & fixing in repairs MCCB 250 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting.
Supply & fixing in repairs MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting.
Supply & fixing in repairs MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting.
Supply & fixing in repairs MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting.
S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete.
Supply & Fixing in replacement modular mini AC box with MCB 20 Amp complete with metal box and 3 Pin, 15 Amps plug top complete all as specified and directed. Make : Indo Asian/Havells/Legrand/ABB Note : Rates are inclusive of cutting / chases for mounting Modular metal box concealed in wall and making good to the disturbed surfaces with OBD / colour wash / white wash and wall putty where ever is required.
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed
M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI strip 25x4 mm dia earth lead by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed
M & L for UL certified earthing electrode 17.2 mm dia 3 mtrs long of low carbon steel electrode with copper bonding of thickness 250 micron, black-fill earthing enhancing compound AXIS ULTRA/AXIFILL type carbon based compound conductive concrete type which has a resistivity of less than 0.12 Ohm Mtr as per clouse 14.5 D of IEEE:80 complete standard. Black fill compound should be electronically conductive (like in metals) and should bedepend on moisture for conduction. Black-fill compound should be environment friendly & should be solidify when mixed with water set like concrete and should not letch/diffuse into the ground. Black - fill compound shall not be mixed with any soil whiling pouring in the bore hole. Test certificate as per IEC:62561-7 for black fill compound shall be submitted along with the material including SS clamp to be provodeboth side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID , incl copper strip of size 20x3 mm from earthing to LT panel/TPN DB/SPN DB or any other important machinery complete all as specified. Note : (i) Earth electrode should be applicable standards IS : 3043, IEC62561-2 & IEC 60364 -5 ans made of High Tensile steel rods copper bounded, High Tensile strength, good electrical conduction & effective performance and suitable for all types of soil and provided minimum distance 3 mtrs. (ii) Black-fill compound should be Compliance to the standards IEEE: 80, IS -3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification . (iii) Positive low resistance electrical connection to the earth . (iv) Does not contain hazardous chemicals. (v) Electrinically conductive (like in metals) and is not dependent on moisture (vi) Provide the desire value of earthresistance as per required specified values. (vii) Provide the Exothermic welding joints to entire grid system joints of earthing electrode (viii) Test certificate to be provide of each electrode.
Supplying & Fix in replacement 1100 volts grade 6 sqmm heavy duty stranded cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 2 mm suspension wire, one twin core cable flat or circular
Supplying & Fix in replacement 1100 volts grade 10 sqmm heavy duty stranded cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 2 mm suspension wire, one twin core cable flat or circular
Clening & servicing of LT panel of board indoor type of size & any type, made out of 2 mm thick CRCA sheet suitable for 415 volts, 3 phase, 4 wire, duly painted with two coats of synthetic enamelled paint and checking of all MCCB/MCB and connected wiring all as specified and as directed by Engineer-in-Charge Note : If require MCCB/MCB to be measured & paid separately under relevent items of works.
Supply and fixing of outdoor type luminaire post top luminrare (prince opera midi) of 240 v,50hz of capacity 40 watt LED luminare ip 65 suitable for mounting on 60 mm OD pipe on necessasry PCC works incl all fixing arrangaement complete all as specified and directed Make :Cat Part No : LPTO-40-CDL-M of CG or equivalent in Philips/C&S Cat Part No : LTGLC40WHPLED/W
Supply and fixing LED Bollard with round top 10 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation cable condits for loop in and out , cable connectors complete all as specified and directed.
S&F flood light of capacity 100 watts High efficient light fitting with pressure die cast Aluminum housing and has lenses specially designed for flood Lighting with polycarbonate cover. System level efficacy of the Luminarie > 100 lumens /watts. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 140-270V, THD<10%, High and low protection along with a surge protection of 2.5 KV including provision of suitable dia clamps, nuts, olts & washes etc for fixing the light fittings on wall fixed complete as specified and directed.
Schedule of Credit
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
tenderpage.pdf
Tender Documents • 0.92 MB
BOQ_846924.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .