| 1 | L1₹2.0 LAccepted-AOC | L1 | Accepted-AOC Financial bid is accepted at the Price Rs. 204808.82 By Executive Engineer Maintenance Division 2 (Civil) PWD Lucknow | |
| 2 | L2₹14.2 L+₹2.2 L (18.0%)Rejected-Finance | L2 | Rejected-Finance Financial bid Rejected due to L2 |
Tender Value
₹14.4 L
EMD Value
₹1.4 L
Closing Date
23 Mar 2026, 12:00 pmClosed
EE Maintenance Division 2 (Civil) PWD Lucknow
EE Maintenance Division 2 (Civil) PWD Lucknow
Lal bhadur shastri marg sthit Awas no-6A me adhyaasan parivartan ke falswaroop meeting Hall ke pass ek general bathroom ka nirman, meeting hall ki chaat per water proofing, servant room ke 05 bathroomo ka navinikaran, awas ke bathroomo ki fittings ba
2026_PWDBL_1125107_1
457/E-Tender/2025-26 dt. 09.03.2026
Open Tender
Civil Works - Buildings
Percentage
45 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹860
₹1.4 L
EE Maintenance Division 2 (Civil) PWD Lucknow
7 Aug 2026
17 Mar 2026
23 Mar 2026
17 Mar 2026
23 Mar 2026
17 Mar 2026
18 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.DAR NO-15.3 | 1.26 | Cum | 2,889 | ₹3,640.14 |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm DAR NO-15.23.1 | 90.08 | Sqmt | 59 | ₹5,314.72 |
| 3 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. all kinds of soil . DAR NO-(2.6.1) | 4.2 | Cum | 144 | ₹604.8 |
| 4 | Providing and layeing in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level:1:5:10 (1 cement :5 coasre sand ( Zone-III) :10 graded stone aggregate 40 mm nominal size dar-4.1.10 | 1.34 | Cum | 5,303 | ₹7,106.02 |
| 5 | Brick work with common burnt clay (non madular) brick of class- 150 in foundation and plinth in::1:4( 1 cement :4 coarse sand ) (dar-6.1.1) | 1.38 | Cum | 6,410 | ₹8,845.8 |
| 6 | Brick work with common burnt clay (non madular) brick of class- 150 in superstructure above plinth level up to floor V level in all shape and sizes in cement mortar 1:4 ::(1 cement :4 coarse sand )( Dar 6.4.1) | 9.01 | Cum | 7,603 | ₹68,503.03 |
| 7 | Providing and fixing SWR pipes as per 15:13592 110 mm dia for drain & sewer system with trenching , refilling & testing of joint complete including all fitting , labour and T&P etc . | 35 | Rmt | 734 | ₹25,690 |
| 8 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). foundation concrete 1:4:8 mix (1) cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)With common burnt clay F.P.S. (non modular) bricks of class designation DSR NO-19.7.1.1 | 1 | Nos | 10,390 | ₹10,390 |
| 9 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand) with R.C.C. top slab with 1:1.5:3 mix (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size). foundation concrete 1:4:8 mix (1) cement: 4 coarse sand (zone-III): 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 DSR NO-19.7.2.1 | 2 | Nos | 21,484 | ₹42,968 |
| 10 | Providing and fixing 20mm dia chlorinated polyvinyl chloride (cpvp )pipes , having thermal stability for hot & cold water supply including the supply with clamps at 1.00m spacing . This includes jointing of pipe and fiting with one step salvent cement and testing of joints complete as per direction of Engineer in charge -Internal work - Exposed on wall (dar-18.7.2) | 105 | Rmt | 437 | ₹45,885 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.34 MB
T1_457.pdf
Tender Documents • 1.55 MB
BOQ_2097055.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .