Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹41.2 L+₹1.7 L (4.20%)Rejected-Finance CHENNAI | L2 | Rejected-Finance being high bid value rejected |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
20 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Tirunelveli
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
GE/TVL/8226
2022_MES_540321_1
GE/TVL/8226
Open Tender
Miscellaneous Works
Item Rate
180 days
Ramnad
As per NIT/ Tender documents
8 documents required · 8 mandatory
₹500
GE Tirunelveli
₹76,000
Yes
3 Sept 2022
23 Jul 2022
23 Aug 2022
23 Jul 2022
20 Aug 2022
6 Aug 2022
23 Jul 2022 - 29 Jul 2022
Amount
SCHEDULE 'A' PART-I [ SEWAGE RMD]
Cleaning of septic tank including filter bed by bailing out fluid, decomposed materials sludge etc. scraping and washing the wall with fresh water and disposal of decomposed materials, sludge etc. outside MD land complete all as directed by Engr-in-Charge for the following of septic tanks :- Note 1:- Sludge / de-composed materials obtained from cleaning shall be removed outside MD land by mechnical sewage cleaning tankers. Note 2:- Rate inclusive of clearing away all grass vegetation, saplings shurbs and trees not exceeding 30 cm girth upto 3 mtrs alround the septic tank and removing rubbish upto a distance of 50 mtrs outside the periphery of the area.
(a) 100 users septic tank
(b) 50 user septic tank
Excavation in trenches, not exceeding 1.5 M wide, and not exceeding 1.5 M in depth for foundation etc and getting out in hard / dense soil all as specified
Returning filling in trenches including spreading levelling watering and well ramming in layers not exc 25cms in soil as specified and directed Engr-in-Charge
Removing excavated material/soil to a distance not exc 250 mtr but n exc 500 m away and deposing where as directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engr-in-charge
Demolition and breaking up SWG drain pipe of 150mm dia set in cement concrete as in trenches as directed by Engr-in-charge Note: Excavation and RFR will measeured and paid separately.
Demolition of Plain cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) as in concrete bed to drain pipes for 150 mm dia including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Demolition of brick work built in cement mortar or lime mortar including all quionts, arches, pillers etc but excluding ashlat facing, dressed stone work amd pre cast concrete articles all as specified and as directed.
M&L for brick work with sub class 'B' bricks old size straight or curved on plan exc 6m mean radius built in CM (1:4) all as specified.
M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in CM 1:4 mixed with water proofing compound finished fair and even (without using extra cement) complete as specified and directed. Note: Water proofing compound shall be measured and paid separately.
Supply only integral water proofing compound complete all as specified and directed.
M&L for Plain cement concrete 1:3:6 type C2 (using 40mm graded granite stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M&L Plain cement concrete 1:2:4 type B1 (using 20mm graded granite stone aggregate) as in benching to manholes, coping etc.. including necessary formworks complete all as specified and directed.
M&L for PCC (1:2:4), type B1 in surface channel & drains incl necessary form work complete all as specified & directed.
M&L 150 mm dia HDPE Pipes PN 10 including laying in trenches with all necessary fittings as specified and as directed by Engr-in-Charge
Demolition of cement concrete reinforced cover slabs of man holes etc n.exc 15 cm thick complete all as specified & directed.
M&L for Precast cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in manhole/ gully trap cover slab set in cement mortar 1:4 including necessary form work all as specified and directed.
M&L for TMT bars 10mm and over cut tro length,bend to shape required incl cranking, hooking ends and binding with and inlcuding MS wire (annealed) not less than .9mm dia complete all as specified and as directed
M&L for RCC septic tank for 100 users, including necessary excavation in any type of soil, RFR, disposal of surplus soil to a distance of n. exe 50m, foundation in PCC M 7.5, RCC Wall, base slab, Baffle walls and roof slab covers including beam etc. vent shaft, manhole opening cover connection etc. complete all as shown on drawing No. TD-389(S) sheet No. 1/3 dated 24/09/2019 complete all as specified and as directed
Material and labour for construction of Soakage wells/Pit for 100 user including necessary excavation in any type of soil, RFR, disposal of surplus soil to a distance of n. exe 50m, foundation in PCC M 7.5,RR masonry, granular fill and roof slab covers including ,manhole opening cover connection etc. complete all as shown on drawing No. TD-318(S) sheet No. 1/1 dated 10/03/2006 complete all as specified and as directed
Excavation in trenches n.exc 1.5m wide and n.ex 1.5m depth for foundation etc or for shafts wells, cesspits, manholes pier holes, sewage line etc n.exc 10 Sqm on plani n soft/loose soil complete all as specified and as directed .
Material and labour for 150mm (bore of pipe), reinforced concrete pipes, class NP3, laid to level or to falls in trenches on concrete bed and jointed complete with collars including testing complete all as specified and as directed.
M & L for PCC 1:3:6 type C2(using 20mm graded aggregate) for pre-cast cement concrete block masonry with solid blocks, exc 10cm in width and setting in mortar 1:4 as in drain, manhole complete all as specified and as directed.
Material and Labour for TMT bar 6 to 8mm dia, cut to length, bent to shape required, including cranking,bending spirally for hooping ,for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Removing excavated material to a distance n.exc 50m away and depositing where as directed at a level n.exc 1.5m above the starting point, complete all as specified and as directed.
Material and labour for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in plinth protection 75mm thick surface finished even and smooth without using extra cement complete all as specified and as directed.
M & L 15mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished surfaces even an smooth without using extra cement, complete all as specified and as directed.
Material and Labour for Three coats of white wash on wall surfaces including preparation of new surfuces complete all as specified and directed.
Supply and fixing Precast RCC 3 seater bench with arm rest, back rest 5 feet long for outdoor type including transportation and necessary fixing arrangement complete all as specified and as directed.
SCHEDULE 'A' PART-II (E/M MINOR WORKS RMD)
Material and labour for Point wiring complete with FRLS PVC insulated unsheathed cable 1100V grade conforming to IS-694, 4 Sqmm (nominal area) multistranded with copper conductor drawn through and including non metallic rigid PVC conduit 25mm dia (ISI marked) and accessories, wall / surface (concealed) on ceiling with sunken type pressed steel / welded terminal boxes made out of 1.6mm mild steel sheet, 3mm thick laminated sheet cover for mounting of switches, socket outlets, regulators etc., including provision of FRLS PVC insulated unsheathed 1.5 Sqmm FRLS multistranded with copper conductor as earth continuity conductor and connecting to common earth dolly for One 3/6 pin, 15 Amps Multi purpose switch socket combination on independent board complete all specified and as directed.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 2 runs of 4 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III)/casing caping fixed in walls (Concealed) and all accessories along with 1 run of 4 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly including taking down old complete all as specified and as directed. Note: 2 runs of 4 sqmm cable along with 1 run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
M & L for single pole and neutral (SPN) sheet metal enclosure with a two pin and earth plug and socket complet with one single pole MCB 240 V, 20 amp complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix switch Socket combination 5 Amps / 16 amps, 5 in 1 flush type 240 Volts complete all as specified and as directed.
Supply and fix MCB SP 5 A to 32 A , B curve, 10 kA complete all as specified and as directed.
Supply and fix LT under ground cable 1100 volts grade PVC /XLPE sheathed armoured multistranded heavy duty electric cable with aluminium conductor 4 core 16 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board, testing and commissioning etc complete all as specified and directed.
Material and labour for Sub main wiring with PVC insulated unsheathed 1100 volts FRLS grade single core multi stranded copper conductor cable 4 runs of 4 sqmm drawn through in and including 25mm dia PVC conduit heavy duty ISI marked(IS 9537 Part III)/casing caping fixed in walls (Concealed) and all accessories along with 2 run of 4 sqmm PVC insulated unsheathed copper conductor single core multi stranded cable 1100V FRLS grade as earth continuity conductor and connected to common earth dolly including taking down old complete all as specified and as directed. Note: 4 runs of 4 sqmm cable along with 2 run of 4 sqmm cable for earth conductor and one run of PVC conduit shall be measured as one length.
Supply and fix surface mounted industrial socket 3 Pin 32A , IP 66/67 complete all as specified and as directed.
Supply and fix surface mounted industrial socket 5 Pin 32A , IP 66/67complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 4 way DB with Degree of Protection IP 54 Suitable for MCCB's upto 125A as incomer complete all as specified and as directed.
Supply and fix sheet metal enclosure powder coated double door for Distribution Board, VTPN 6 way DB with Degree of Protection IP 54 Suitable for MCCB's upto 125A as incomer complete all as specified and as directed.
Supply and fix in repair MCB TP 25A - 63 A , C curve 10 kA complete all as specified and as directed.
Supply and fix in repair MCCB 4 pole 415 volts , 80 Amps, with rupturing capacity 16 KA complete all as specified and as directed.
Supply and fix in repair MCCB 4 pole 415 volts , 100 Amps, with rupturing capacity 16 KA complete all as specified and as directed.
Supply ,install and testing split Air conditioner of 1.5 TR capacity BEE 5 star rating with indoor and outdoor units (copper condenser coil, copper cooling coil and evaporator including required length of copper tubing and cables for connecting indoor and outdoor units ) complete with cordless remote control unit , with inverter rotary compressor ,complete all as specified and as directed. Make : VOLTAS / BLUESTAR /CARRIER/ O GENERAL/HITACHI. Note : Rate quoted is inclusive of the following:- (i) Drain pipe UPVC with insulation from indoor unit (at any floor) to ground floor level and is to be fixed with necessary clamps complete. (ii) Drilling hole on the brick wall to facilitate routing of Copper pipe, drain pipe and cable from indoor unit to outdoor unit. (iii) Sealing the hole from outside ,after installation, with white cement. (iv) Pressure testing , cooling performance check and product demonstation . (v) 4 core cable of any required length for connecting indoor and outdoor unit. (vi) Material and labour for fixing Remote stand in wall. (vii) Copper pipe, 1/2" dia and 1/4 " dia upto 3.00 Mtr each.
Supply and fixing of GI powder coated brackets , for fixing of split AC's including grouting with suitable size fastners complete all as specified and directed.
Supply and fixing Copper pipe 1/2" dia with foam insulation including connecting complete all as specified and directed.
Supply and fixing Copper pipe 1/4 " mm dia with foam insulation including connecting complete all as specified and directed.
Supply, Install ,testing and commisioning pump set, centrifugal, electric driven, 5 HP inclusive of joining suction and delivery pipes to pump and foundation for pumpset complete all as specified and directed. Make: KIRLOSKAR BROTHERS LIMITED/Crompton Greaves
Supply and fixing of DOL Controller for 5 HP Pumpset including necessary wiring to motor and connecting input power cable complete all as specified and directed.
Supply and laying, of galvanised steel water tubes, medium grade 65mm bore with and including all necessary GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/ceiling including testing complete all as specified and as directed.
Supply and laying, of galvanised steel water tubes, medium grade 50mm bore with and including all necessary GI fittings such as bends, elbows, short piece connections, backnuts, caps plugs, unions etc., laid in trenches/wall/ceiling including testing complete all as specified and as directed.
Excavating in trenches, not exc 1.5m wide and not exc 1.5m in depth; for laying pipes/cables and getting out in any type of soil, complete all as specified
Supply, spreading and compacting of riddled earth for cable cushion on both top and bottom of cable, including ramming as specified and directed by Engineer-in-Charge. (Note :- Punned thickness only will be measured)
Supply and lay bricks in trenches , common burnt clay building bricks, subclass `B’ designation 75, old size ,with width equal to the length of the brick; complete all as specified and directed.
Demolition, Cement concrete (unreinforced) in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and as directed by the Engineer-in-Charge.
M & L for 100 mm thick cement concrete 1:2:4 type B-1, using 20mm graded aggregate for making good the disturbed road surface after laying of pipe/cable line over returned filled and compacted earth surface to match with existing road level complete all as specified and as directed.
Supply and laying GI tubing Light grade of size 40 mm dia bore laid in trenches / on floors / walls/ceiling for protection of UG cable complete all as specified and as directed.
Earthing complete with GI earth plate electrode 600 x 600 x 6.0mm buried directly in ground vertically to a depth not less than 2.25 M below GL with top edge of the earth plate not less than 1.5 M below normal GL connected with GI earth wire 4mm dia by means of bolts, nuts check nut and washers of GI and earth wire protected by GI pipe 40mm bore light grade and watering pipe 20mm bore GI pipe medium grade including one test point for testing purpose with funnel and connected to switch/control board upto 7.5m away from earth electrode including earth work, PCC (1:3:6) type C-1 chamber, RCC (1:2:4) type B-1cover slab 50mm thick with 8mm dia TMT bars reinforcement both ways at 140mm C/C, charcoal, salt, water pipe, wire mesh, lugs etc and testing complete all as applicable and as per Plate No. 3 of SSR 2009 and all as specified. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia watering pipe, wire mesh,40mm dia light grade GI protection pipe for earth strip etc., complete.The rate quoted shall be deemed to include for Earth continuity conductor and GI protection pipe upto 7.5m.
VVM CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .