Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | L1 | Accepted-AOC Lowest bid. | |
| 2 | L2₹15.5 L+₹1.4 L (9.70%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹16.0 L+₹1.8 L (12.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
9 Sept 2023, 6:00 pmClosed
GE SOUTH MAMUN
GE SOUTH MAMUN PATHANKOT-145001
REPAIR AND REPLACEMENT OF SECURITY LIGHT LED FLOOD LIGHTS, DAMAGED LT CABLE AND CONNECTED ACCESSORIES AT D-II ZONE AND CBS GHAROTA AREA UNDER AGE E/M OF GE (S) MAMUN
2023_MES_613511_1
GE(S)/M-30/2023-24
Open Tender
Miscellaneous Works
Item Rate
270 days
GE SOUTH MAMUN
AS PER NIT
8 documents required · 8 mandatory
₹500
GE SOUTH MAMUN
₹30,000
Yes
16 Oct 2023
12 Aug 2023
16 Sept 2023
12 Aug 2023
9 Sept 2023
26 Aug 2023
Amount
S&F in replacement of bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts & washer and painting of clamps and street light fittings brackets with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint including taking out old one complete all as specified and directed.
S&F in replacement of bracket for street light fitting made out of 25mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts & washers and painting of clamps and street light fitting bracket with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint including taking out old one complete all as specified and directed.
S&F in repairs and testing of 45 W LED street Light luminaire , made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree)complete all as specified and directed including taking out old one . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed.
S&F in repairs and testing of 60 W LED street Light luminaire made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree)complete all as specified and directed including taking out old one . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed.
S&F in repairs and testing of 70/72 W LED street Light luminaire made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree)complete all as specified and directed including taking out old one . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed.
S&F in repairs and testing of 150 W LED street Light luminaire made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with individual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree)complete all as specified and directed including taking out old one . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed.
S&F in repairs of decorative post top lantern 40 watts 230 volts, 50 HZ, mushroom or oval shaped in sothing opal/ prismatic finish made up of polycarbonate, suitable for 40 watt LED, all accessories prewired complete all as specified and directed .
Note for srl item No 3 to 7 above 1. Driver shall be potted anti-vibration types. 2. LM-79 and LM-80 test report with 1 Lakh burning hours LED life from NABL lab shall be provided. 3. CRI (Colour Rendering Index) of fixture shall be > 70. 4. CCT (Colour Co-related Temperature of fixture shall be 5700K + 300 K. 5. System Lumen Efficacy shall be > 100 Lm/W. 6. 10 KV separate Surge Protection shall be provided as a part of fitting. 7. 5 years guarantee shall be provided by contractor supported by OEM covering all parts of luminaire. 8. Lenses shall be Modular Type. 9. PCB used shall be MC PCB type. 10. The defect liability period of LED light shall be 05 years from the certified date of completion & the contractor shall replace/repair the defective fitting within 07 days after handing over to contractor for replacement/repair. 11. CA No. shall be written on each fitting before installation. 12. The name of manufacturer to be embossed on the fitting. 13. The fittings shall have arrangement so that maintenance required, if any can be carried out from Top cover.
M&L in repairs for stay assembly comprising stay 14 mm dia and 40 cm long stay rod 20 mm dia and 1.8 m long threaded ends with nuts, mild steel plate 30 cm X 30 cm X 6 mm thick and two number of thimble etc. complete with accessories as shown in electrical plate No. 1 of SSR Part-I of 2009 including taking down existing stay assembly complete all as specified and directed. Note:- Loop type insulator, stay clamps, excavation & earh work and concrete shall be measured and paid separately.
M&L in repairs for galvanized steel stay wire size 7/ 4.0 mm for stay of poles complete all as specified and directed.
M&L in repairs for loop type insulator vitreous, poecelain, white/brown/green, large size, with overall dimensions 65 x 90 mm, clearance of hole 16 mm complete all as specified and directed.
S&F as in repairs of industrial switchgear busbar chambers of 200Amp,of size 600 x 600 x 150 mm, 6 way for LT cable any size including necessary PCC/Wall mounting work, cable gland, complete all as specified and directed.
S&F in repairs of old unserviceable copper conductor cable three core PVC insulated and sheathed copper conductor cable of size 1.5 sqmm laid down through the existing pole/GI pipe bracket complete all as specified and directed.
S&F in repairs optimum adjustable range MCCB FP 415 volts, IEC 60947-II 63 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
S&F in repairs optimum adjustable range MCCB FP 415 volts, IEC 60947-II 100 Amps rating with rupturing capacity 25 KA including providing thimble for out going cables and taking out unserviceable MCCB FP of any deccription / type etc. complete from LT Panel, complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable end termination joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 120 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 25 sqmm to 50 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
Supplying, jointing and connecting "as in repairs" cable straight through joint kit, out door, heat shrinkable type for underground cable including jointing kits and labour complete for making joints suitable for aluminium conductor cable of size 70 sqmm to 95 Sqmm 3.5 core, 1100 volts grade cable including excavation and earth work complete all as specified and directed.
S&F in replacement of service cable of size 10 sqmm, twin core multistranded 1100 volts grade heavy duty cable PVC insulated aluminiun conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1m apart including 4mm suspended with galavnised steel wire, including taking out old one complete all as specified and directed.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed. Note :- Rate of taking out of old cables and brick bats is deemed to be included in the qouted rate.
Excavating in trenches in any type of soil, n. exc. 1.5 m wide and exc. 1.5 m but n.exc 3 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed.
Removing excavated material (soil) n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in coping of pole complete all as specified and directed.
M&L for dry clean fine river sand as in sand cushioning to underground cable 23cm thick (8cm before laying & 15cm after laying cable) including punning down of sand layer complete all as specified and directed. Note :- Punned thickness shall only be measured and paid.
M&L for brick protection with sub class 'B' old size brick well burnt laid flat for cable protection abutting each other laid dry with width equal to length of brick complete all as specified and directed.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 6 Sqmm x 2 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 10 Sqmm x 2 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 2 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 4 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 25 Sqmm x 3.5 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 35 Sqmm x 3.5 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Relaying only in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 50 Sqmm x 3.5 core complete all as specified and directed. Note:- Cable obtained out during excavation under item No.22 shall be relaid under this item.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 2 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 4 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 25 Sqmm x 4 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 50 Sqmm x 3.5 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated PVC sheathed, armoured heavy duty electric cable , with aluminium conductor of size 95 Sqmm x 3.5 core complete all as specified and directed. Note:- Excavation and earth work, sand cushioning, brick cover and protection pipe etc. shall be measured and paid for separately.
S&F in replacement of GI tubing light grade 40 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc all as required at site including taking out old one complete all as specified and directed.
S&F in replacement of GI tubing light grade 80 mm bore cut to size and fixed along the pole for cable protection including clamp 02 Nos of size 25x4 mm, nut bolts , washers etc all as required at site including taking out old one complete all as specified and directed.
M&L for shifting of PCC/Steel pole from one location to other location after digging of earth and dismantling of PCC with the help of JCB and other connected accessories & removing accessories. Refixing the pole with connected items and providing two coat of alternative green and white strips of 30cm each upto 1.5 mtr height from coping/ ground level using synthetic enamel paint and marking of the pole number with black enamel paint over yellow circle of dia 100mm complete all as specified and directed.
M&L for scraping of old paint from the steel tubular pole 9 Mtr height with out removing accessories and preparation of surfaces for repainting, repainting the pole with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamel paint including marking the pole number with black enamel paint over yellow circle of dia 100mm. Repainting the remaining pole and iron parts i.e 'U' clamps, channels etc above 1.5 mtr height by applying one coat of alumn paint, complete all as specified and directed.
S&F in replacement of electronic driver after taking down street light, as per existing make and size, suitable for LED fittings of cap upto 60-90 watts any type and of approved make, and refixing the light complete all as specified and directed.
S&F in replacement of electronic driver after taking down street light, as per existing make and size, suitable for LED fittings of cap upto 100-150 watts any type and of approved make, and refixing the light complete all as specified and directed
S&F in replacement MCB single pole 240 volts,C series rating from 6 to 32 amps with rupturing capacity 10 KA including providing thimble for out going cables and taking out unserviceable MCB of any deccription , complete all as specified and directed.
Supply and erecting in true vertical position steel tubular swaged poles of 9.00 metres long, type 410 SP-31 complete with cast iron base plate, goose neck bracket, finial taper plug , bolt, nuts & screws as specified and painting internal surface with anti-corrosive paint and external surface painting up to 1.5 m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide over a coat of red oxide primer and remaing portion with two coats of aluminum paint over a coat of red oxide primer,including writing pole number including demolition of old pole, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
Supply and erecting in true vertical position prestressed concrete pole of 9.00 metres long,102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 including zebra painting to pcc pole up to 1.5m height from base of poles with two coats of synthetic enamel paint Ist quality black & yellow colour alternate strip 30 cm wide and remaing portion with two coats of syntheticenamel paint over a coat of primer, including writing pole number including demolition of old pole, complete all as specified and directed. Note:-Excavation and earth work and concrete in foundation and pedestal shall be measured and paid for separately.
M&L for earthing with GI earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 25x4mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate and filling of vegetable soil to the remaining 10%,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed by Engr-In-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Trimming up of Bushes/ Tree branches all around overhead lines and removing cut branches from site complete all as specified and directed. Notes :- i) The overhead lines will be kept clear from all trees by trimming of tree branches upto 5 mtr all around the line. ii)Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. iii) only effected Span at site shall be measured where tree branches are touching nearly HT/LT lines complete all as specified and directed. iv) The length of one span varies from 30 to 50 mtrs
M&L for preparing the surfaces and painting of PCC pole 9 mtr height without removing accessories with one coat of alternative green and white strips of 30cm each upto 1.5 Mtr height using synthetic enamell paint . marking the pole number with black synthetic enamel paint over yellow circle of dia 100mm. Painting the steel parts i.e clamps, channels etc by applying two coats of alumnium paint all as required at site, complete all as specified and directed.
S&F as in replacement of surge protection device of cap 10 KA after taking down street light, ISI approved company made as per existing make and size suitable for LED fittings of capacity upto 150watts complete all as specified and directed.
M&L as in repair/replacement of mild steel cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat & two coats of aluminium paint including dismantling from pole complete all as specified and directed.
Re-stretching/Re-stringing of existing over head line ACSR/copper conductor of LT/HT type on existing PCC/steel pole including 22 gauge aluminium binding wire, line connectors jumpers etc. including connections of incoming and outgoing cables, binding with spacers where required all as directed by Engineer-in-Charge. NOTE:- (a) For measurement purpose distance between centre of adjacent pole will be considered. (b) Contractors quoted rate is inclusive of rejointing of ACSR/Copper conductor if damaged during restraining.
M&L in repairs for ACSR conductor (Weasel conductor 6 x 2.59 + 1 x 2.59 Al + Steel), of any size drawn straight horizontal on over head lines on poles including binding with insulators using aluminium binding wire, jointing jumpers etc including connections of incoming and out going cables, including dismantling and taking down carefully existing old ACSR conductor/GI wire of any size from HT/LT overhead line complete all as specified and directed. Note:- 3% for sag shall be added.
M&L for in repairs GI wire 4mm dia drawn straight horizontal as continuous earth wire on poles or fabrication of cradles complete all as specified and directed.
Dismantling insulator any type, any size and keeping serviceable insulators aside for reuse removing unserviceable insulators from site complete all as specified and directed.
S & F Pin type, porcelain, vitreous, white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade all as specified and directed.
S & F in repairs Shackle type insulators porcelain, vitreous, white,brown or green insulator including one set of galvanised mild steel section of straps 31 x3 mm, dia of bolt 12mm alongwith iron washers and one galvanised iron nut, 75mm height, 95mm dia for 1100 volts grade all as specified and directed.
S&F for junction box of size 260 x 160 x 250 mm made out of 3.15mm thick CRCA powder coated sheet , front door openable with fixing arrangement by nut & bolts including 63 Amp having four number of aluminium bus bar mounted on epoxy based post insulators and drilled holes for including MCB SP 6 Amps-01 No. all as required and fixed to poles using MS clamps of size 32x6mm and including nuts, bolts and washers connected electrically complete all as specified and directed.
KULBHUSHAN AGGARWAL
GOLDEN CONSTRUCTIONS
Bidder Name
KULBHUSHAN AGGARWAL
GOLDEN CONSTRUCTIONS
M/S SHRI RAM BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .