Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC OK | |
| 2 | L2₹12.7 L+₹1.9 L (17.2%)Rejected-Finance 99 MODEL TOWN PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹12.8 L+₹2.0 L (18.5%)Rejected-Finance I 910 JAHANGIR PURI NEAR BY ANAND MAYA HOSPITAL NORTH WEST DELHI DELHI 110033 UDYAM DL 06 0040830 | NORTH DELHI | DELHI | 110033 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹14.6 L+₹3.8 L (35.6%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹17.1 L+₹6.3 L (58.2%)Rejected-Finance BX 167 4 ISHWAR NAGAR PATHANKOT PUNJAB 145001 UDYAM PB 16 0001334 03AALFR1593C1ZE B R | PATHANKOT | PUNJAB | 145001 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
8 Jun 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
REPAIR AND REPLACEMENT OF HIGH MAST LIGHTS , PERIMETER LIGHTS INCLUDING ALLIED WORKS UNDER GE (WEST) PATHANKOT
2020_MES_329161_1
CWE/P-60/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Pathankot
class E and above Category b i
9 documents required · 9 mandatory
₹500
Yes
GE (West) Pathankot
₹50,000
Yes
24 Jun 2020
27 Feb 2020
10 Jun 2020
27 Feb 2020
8 Jun 2020
12 Mar 2020
Amount
Taking down old UNSV light fitting of any type and S&F LED light fitting 45 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded) FR cable of 6 Sq mm size in PVC conduit 20 mm dia , min 1.8 mm thickness with clamps complete all as specified and directed by Engr-in-Charge.
Taking down old UNSV light fitting of any type and S&F LED light fitting 75 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded) FR cable of 6 Sq mm size in PVC conduit 20 mm dia , min 1.8 mm thicknesswith clamps complete all as specified and directed by Engr-in-Charge.
Taking down old UNSV light fitting of any type and S&F LED light fitting 90 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded) FR cable of 6 Sq mm size in PVC conduit 20 mm dia , min 1.8 mm thickness with clamps complete all as specified and directed by Engr-in-Charge.
Taking down old UNSV light fitting of any type and S&F LED light fitting 120 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 120 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded)FR cable of 6 Sq mm size in PVC conduit 20 mm dia , min 1.8 mm thickness with clamps complete all as specified and directed by Engr-in-Charge.
Taking down old UNSV light fitting of any type and S&F LED Flood Light 150 W LED, CCT not less 6000K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 150 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded)FR cable of 6 Sq mm size in PVC conduit with clamps complete all as specified and directed by Engr-in-Charge.
Taking down old UNSV light fitting of any type and S&F LED High mast light fitting 150 W LED, CCT not less 6500K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 150 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded)FR cable of 6 Sq mm size in PVC conduit 20 mm dia , min 1.8 mm thickness with clamps complete all as specified and directed by Engr-in-Charge.
Taking down old UNSV light fitting of any type and S&F LED Bay light fitting 150 W LED, CCT not less 6500K pressure die cast aluminium housing ,heat resistance toughened glass with frame IP 66 protection LED lumen efficacy not less then 150 lumen/watt, reflector lenses for uniform light distribution on each LED complete fixed on New bracket and making connections with provision of PVC insulated Aluminium conductor (multistranded) FR cable of 6 Sq mm size in PVC conduit 20 mm dia , min 1.8 mm thickness with clamps complete all as specified and directed. Notes forSrl item no 1 to 7 :- The LEDs used in the product shall be of reputed make as approved by GE with minimum LED efficacy of 130lm/W. The LED shall be tested with LM80-08 standard with Useful life of 50000 Hrs @ L70. The LEDs used in Street Light shall have CCT of ANSI Bin Warm White (between 5000-6500 K ) with CRI of 70. LEDs used must be tested as per EN62471 for Photobiological Safety of humans.
The Input voltage range shall be 150V to 270V. The LED Street Light luminaire shall have secondary lens optics for optimum light distribution. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED luminaire shall have minimum 3.2KV surge protection. The LED Street Light shall have power factor more than 0.95 with THD less than 10%. LED Driver Output voltage shall be less than SELV Limits for safe operation and maintenance. The driver should be fully designed and manufactured in India .The letter of Association with LED manufacturer for LEDs used in the fixture should be submitted to ensure high quality led chips are used in the fixture. LM79,LM80 and photobiological reports should be submitted.
M&L for bracket in replacement for fixing of street light fittings bend to shape, made out of 32 mm dia GI pipe medium grade upto 1.5 metre long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge.
S&F three core Aluminium conductor PVC insulated cable of size 6 sqmm FR multistranded 1100 volts grade complete all as directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/loose soil for laying of cable ,pole foundation,stay,laying of pipe etc complete all as specified and directed.
Ditto all as per item No.10 above but depth exceeding 1.5 metre and not exceeding 3 metre.
Returning filling in, including spreading ,leveling ,watering and well ramming in layers not exc 25 cm complete all as specified.
M&L for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying and punned upto 18 cm, stretching and testing the cable as specified in clause 19.75 of SSR Part-1
Brick covering with equal to length of brick as mechanical protection to cable with well burnt sub class 'B' bricks laid as directed.
Removing excavated soil to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, in replacement of cross-sectional area 16 Sqmm, 2 core including taking down of old UNSV cable.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminum conductor, 1100 volts grade, in replacement of cross-sectional area 10 Sqmm, 2 core including taking down of old UNSV cable.
M&L for GI tubing light grade 50 mm bore for cable protection laid in trenches in road crossing or fixed to wall/Pole.
M&L for Prestressed concrete pole, 9.0 metre long 102mm x 152mm at top and 102 mm x 289 mm at bottom, class 10 in replacement including dismantling of old UNSV pole , numbering new pole and applying two coats of synethic enamel paint upto 1.5 mtr from top of coping in black and white strip alternately each 30 cm wide.(Note: Earth work including excavation ,Returning filing,PCC work,removing excated material will be measured and paid separetly under respective items of schedule)
M&L PCC 1:4:8 type D-2 ( Using 40mm graded stone aggregate ) as in foundation of poles filling and mass concrete complete all as specified.
M&L PCC 1:3:6 type C-1 ( using20mm graded stone aggregate) as in foundation of poles/coping,stay etc complete all as specified.
M&L for factory made sheet metal enclosure of suitable size out door type fabricated out of 2.4 mm thick CRCA sheet powder coated dust and vermin proof having entry from lower side with cable gland for cable of size 10 Sq mm 2 core with aluminium bus bar single phase and nautral current carrying capacity of aluminium bus bar should be upto 63 Amps mounted on poreclain insulator complete with operating voltage 220 volts, 50 Hz including one number MCB of capacity 6 amp for street light mounted in sheet enclosure prewired with minimum 1.5 Sq mm copper conductor cable with lugs including locking arrangement complete and enclosure fitting on pole with clamps nuts, bolts and washers including making connection from Junction box to S/L fitting with 1.5 sqmm PVC insulated FR cable for phase, neutral and earth complete or all as specified and directed by Engr-in-Charge.
Supply and Fixing Automatic street light timer switch single phase 3kW, 230 V Swadeep-02EC 3 kW1P model as a pole mountable SMC enclosure consisting of Nature Switch-02 as the controlling unit, Power Contactor(s) & MCBs 25 Amps (both Input-Output) of suitable power rating and Copper wiring (min.10 sq.mm.) with proper lugs & terminal blocks. The SMC enclosure comes complete with open able door and mounting clamps. The SINTEX make enclosure is made of UV stabilized, FR grade special moulding compound and it is Rust proof, Electric Shock proof, Termite proof, Outdoor mountable conforming to IP54 .Make : Swadeep-02EC 3 kW1P or equivalent in Hager/ L&T all as directed by Engr-in-charge.
Supply and Fixing Automatic street light timer switch three phase 3kW, 230 V Swadeep 02 EC 8kW3P model as a pole mountable SMC enclosure consisting of Nature Switch-02 as the controlling unit, Power Contactor(s) & MCBs 32 Amps (both Input-Output) of suitable power rating and Copper wiring (min.10 sq.mm.) with proper lugs & terminal blocks. The SMC enclosure comes complete with open able door and mounting clamps. The SINTEX make enclosure is made of UV stabilized, FR grade special moulding compound and it is Rust proof, Electric Shock proof, Termite proof, Outdoor mountable conforming to IP54 .Make : Swadeep -02 EC 8kW3P or equivalent in Hager/ L&T all as directed by Engr-in-charge.
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule (BoQ) to arrive at Contract Sum.
satpal and brothers
SATISH AND CO
commercial traders
M/S RUDHRAKSH TRADING CO
dinesh enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .