| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹11.2 L+₹1.2 L (12.1%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹15.8 L+₹5.8 L (57.5%)Rejected-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹9.6 L
EMD Value
₹19,100
Closing Date
7 Feb 2023, 6:00 pmClosed
AGE I RD AVADI
AGE I RD AVADI CHENNAI
REPAIR/ MAINTENANCE OF HT VCB, TRANSFORMER AND CONNECTED WORKS AT TECHNICAL AREA CVRDE AVADI
2022_MES_557086_2
8533/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AVADI
AS PER NIT DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹19,100
Yes
7 Mar 2023
4 Jan 2023
9 Feb 2023
4 Jan 2023
7 Feb 2023
23 Jan 2023
4 Jan 2023 - 23 Jan 2023
Amount
Taking out old unserviceable under ground PVC/XLPE HT cable of any size from trenches/ wall/roof/road/pipe/pole including segregation of serviceable bricks for re-use complete all as specified and as directed.
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5M depth in soft/loose soil for laying of cable, pipes etc and getting out in soft/loose soil all as specified and as directed.
Retruning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms of soil complete all as specified and as directed.
Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and as directed.
Supply and spread sand for sand cushioning of cables in trenches all as specified in MES Schedule Part-I and all as directed. Note: Punned thickness will only be measured and paid.
Re- laying old un-reinforced precast concrete cable cover, class any size all as specified and as directed
M & L for Taking proper shut down and disconnecting the cables from VCB, draw out faulty VCB breakers from panel 1250/800/630A 13.1KA rating Indoor type make of SEIMENS/ CROMPTON/SCHINDER after removing VCB spout and CT overhauling improving of IR value of hot air oven process and alightnment of mechanism including installation in the same location and testing complete all as specified and as directed.
Relaying/ re routing of old serviceable under ground PVC/XLPE LT cable any grade and any size in trenches/fixed to wall/pole/roof/laid in floor including necessary connections and thimbling complete all as specified and as directed. (Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).
Supplying and toping up new mineral grade transformer oil EHV type confirming to IS-335 to 1983 for filling and for topping up in transformer/Voltage stabilizer duly filtered with filer plant to obtain high dielectric not less 60KV (Gap 2.5mm) complete all as specified and as directed by Engineer In charge.
M& L for Purification, filtration and Dehydration of transformer oil of transformer installed at various indoor/outdoor sub station by ultra high vacuum filtration machine with stream line filtration plant at a temp 60 to 70 deg. Celsius and achieving minimum dielectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as specified and directed by Engineer-in-Charge. Note: (i) Contractor shall ensure no wastage of transformer oil. (ii) Oil required for topping up the transformer will be measured & paid separately.(iii) Contractor shall be ensure that the conservator tanks are full to its level before starting the dehydration
M&L for (in repair) cable jointing kit for 11 KV cable for indoor end termination cold shrink with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, indoor type all as directed.
M&L for (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor of size 120sqmm to 185 sqmm cable complete all as specified and as directed.
M&L for (in repair) cable jointing kit for 11 KV cable for out door end termination Heat shrinkable with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm, indoor type all as directed.,
M&L for (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE, armoured aluminium conductor of size 240sqmm to 400 sqmm cable complete all as specified and as directed.
M&L for Servicing HT VCB panel cum breaker 1250/800/630A 13.1KA rating Indoor type make of SEIMENS/ CROMPTON/SCHINDER after taking proper shut down and disconnecting the cables from panel draw out VCB breakers, earth fault relay, checking alignment of VCB isolating contact, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decarburizing of panel, bus bar section & circuit section including incoming/ outgoing cables, provide necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of worn-out/defective spares like tension springs, torsion springs, nut bolts, washers of suitable size, lingers and de-carbonizing all joints, bus bar, CTs, PTs spout metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance of breaker under the supervision of authorized dealer /representative and reconnecting the panel/breaker in its original position and testing all as specified and as directed. Note: - (i) The rate quoted inclusive of all minor spares etc. (ii) Spares parts required other than mentioned here-in-after shall be deemed to be included in the quoted rate.
Supply only shunt trip coil 220/110 or 30Volts DC
Supply only closing trip coil 220/110 or 30Volts DC
Supply only bus bar insulator 11KV complete all as specified and as directed.
Supply only contact system for VD4-630A suitable for SEIMENS/CROMPTON/SCHINDER make HT breaker
Supply only Aux switch suitable for SEIMENS/CROMPTON/SCHINDER make HT breaker
Supply only spring drum suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
Supply only spring V4207 suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
Supply only Roller chain V4208 suitable for SEIMENS/ CROMPTON/ SCHINDER make 11KV breaker
Supply only Tension spring suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
S&F in repair digital volt meter for HT breakers
Supply only motor cut off switch suitable for SEIMENS/CROMPTON /SCHINDER make 11KV HT breaker
Supply only ‘On Off’ indicator (display) suitable for SEIMENS/CROMPTON /SCHINDER make 11KV HT breaker
Supply only panel space heater 80W complete all as specified
M&L for Inspecting electronic relay (over current relay and earth fault relay) from the 11 KV VCB and calliberating the relay with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping/ functioning system complete all as specified and as directed.
S&F in fuse element 20A - 50A at 2/4pole 11KV structure unit complete all as specified and as directed.
M&L for checking Insulator, lightning arrestor and tightening/replace aluminum jumbler connection complete at 2/4 pole 11KV structure complete all as specified and as directed.
Taking proper shut down and disconnecting the cables from VCB and removing and shifting CT to other VCB suitable capacity and re connecting the cable to VCB all as specified and as directed.
M & L Taking proper shut down and disconnecting the cables from ACB, draw out faulty ACB breakers from panel any capacity after removing ACB complete general servicing and alightnment of mechanism and of major and minor defective parts,wiring including installation in the same location and testing, complete, all as specified and directed.
S&F in repair LED Indication lamps suitable for HT breakers complete all as specified and as directed.
M&L for defect rectification in HT 11KV cable lay in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size up to 240 Sqmm 3 core. Note : (i) The contractor shall bring the fault locating equipment at site withn 02 hours of instructions received from Engr-in-Charge and he shall ensure that the fault is rectified within 24 hours of receipt of intimation from Engineer-in-Charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues with effect from the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of "each job" shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch which are detected during fault detection and the contractor unit rate quated shall be deemed to include for the same and all such defects/ faults which are detected in that particular stretch shall be considered as one unit. (iii) Joints, jointing materials and cable required shall be measured and paid for separately. (iv) The payment is not applicabe for error fault finding location
M & L Disconnecting LT connections of existing Battery charger 30Volt 25 Amp with control panel at substation and repaired to authorized dealer necessary repair/replacement of major and minor defective parts,wiring including installation in the same location and testing, complete, all as specified and directed. Note: - (i) The rate quoted inclusive of all spares etc.
S & F of New air ventilation louver arrangement for existing VCB Panel including and taking down Unsv air ventilation louver all as specified and as directed
S & F air ventiltion fan with wiring of exisitng panel and taking down unsv ventilation fan with wiring complete all as specified and as directed
S& F 200 watt heater for exisitng panel and taking down unsv heater complete all as specified and as directed
Material and Labour for rewinding of HV side of copper wound transformer with using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer, complete, and hot air oven process all as specified and as directed by Engr-in-Charge. Note :- The rate quoted is deemed to be included in the unit rate for varnishing,sleeving and insulating materials.
Material and Labour for re insulation complete of LV side of copper wound transformer with using original gauge/data including insulating materials such as cotton tape, packing and sleeves etc varnishing by vacuum impregnation and baking of coil core assembly for copper wound transformer, complete and hot air oven process, all as specified and as directed by Engr-in-Charge. Note :- The rate quoted is deemed to be included in the unit rate for varnishing,sleeving and insulating materials.
S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 50 to 300 KVA
S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 400 to 1000 KVA
S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 50 to 300 KVA
S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 400 to 1000 KVA
Taking out the unserviceable breather assembly complete form indoor/outdoor type transformer capacity up to 2000KVA and supply and fixing the new breather assembly complete filled with fresh blue silica gel including connecting with proper rubberized gasket complete al as specified and as directed
S&F new silica gel complete all as directed.
S&F in replacement of Pin insulator HT 11 KV. Make: Jaipuria or equivalent
Material and Labour for preparing surfaces of transformer of capacity up to 500 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, complete all as specified and as directed .Note. Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor. Shut down schedule for painting of transformer will be submitted in advance to plan shut down in the station.
Material and Labour for preparing surfaces of transformer of capacity up to 2000 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, complete all as specified and as directed .Note. Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor. Shut down schedule for painting of transformer will be submitted in advance to plan shut down in the station.
Supply and laying HT XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable ( heavy duty ) with aluminum conductor 11000 volt grade, cross sectional area 150 Sqmm, 3 core (earthed) conforming to IS-7098 (Part-I) laid in trenches / under floor / roads / along poles/ducts etc. all as specified and directed
Taking proper shut down permission in writing and disconnecting the HT & LT connections of existing Indoor/Outdoor type transformer of capacity upto 1000 KVA mounted on 2/4 pole structure/plinth and transport to authorized workshop for repair and back to site after necessary repair/replacement of defective parts including installation in the same location and testing, complete, all as specified and directed. (i) Placing /removing standby transformer in the place of defective transformer under repair including loading/unloading, shifting including transportation and make the system/line functional will be the responsibility of the contractor, LT cables, switch gear and other connected items for temporary connection will be provided by the contractor. Contractor’s quoted rates shall be inclusive of all these factors. (a) The quoted rate quoted for the item includes the following :- (i) Arrangement of manpower, tools and plants and Recovery vehicle for transportation and shifting of transformer to work shop and back. (ii) Toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (Transformer oil will be measured and paid separately). (iii) Cutting/chipping of RCC/PCC plastering of foundation/platform and minor grill work/welding work. (iv) Winding material, labour and other items shall be measured and paid separately under respective items. (v) Contractor shall inform the department for inspection on the same day on receipt of repaired transformer from the workshop. (vi) Transformer shall be tested in presence of Engineer-in-Charge at workshop and after installation at site and test result shall be kept in record duly signed by all concerned. One day prior intimation shall be given to the Engr-in-Charge for testing. (vii) Any loss/damage occurred to transformer in all respect during transportation/ installation shall be made good by the contractor at no cost to department.
Global Safety Engineering and Management Solutions
BKR Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .