Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹26.9 L
EMD Value
₹53,876
Closing Date
3 Apr 2024, 6:00 pmClosed
EXECUTIVE ENGINEER (CIVIL)
1st floor old cto building
Internal external painting of building Compound wall and miscellaneous civil repair works at SATCOM building WMS compound Bangalore
2024_BSNL_192316_1
85/EEC/BSNL/CD/BGL/2023-2024
Open Tender
Civil Works - Buildings
Item Rate
90 days
BENGALURU
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
ACCOUNTS OFFICER CASH HQ BSNL BGTD BANGALORE
₹53,876
6 Apr 2024
23 Mar 2024
5 Apr 2024
24 Mar 2024
3 Apr 2024
25 Mar 2024
25 Mar 2024 - 2 Apr 2024
Amount
Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer in-charge
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
For thickness of tiles 10 mm to 25 mm
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :
All kinds of soil
Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.
Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc., up to floor five level, excluding the cost of centering, shuttering and finishing :
1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but, excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone- III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources ).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinalpartitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finishedsmooth.
Granite Stone of approved shade
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Single rubber stopper
Providing and fixing 2nd class teak wood lipping/ moulded beading or taj beading of size 18X5 mm fixed with wooden adhesive of approved quality and screws/ nails on the edges of the Pre-laminated particle board as per direction of Engineer-in-charge.
Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia. 0.50 mm with available beading all complete.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS:12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on both sides.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm)
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg., for doors, including cost of cutting floors ,embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge.
With stainless steel cover plate minimum 1.25 mm thickness.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i)Single socketed pipes.
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
Bend 87.5° 110 mm bend.
Shoe (plain) 110 mm Shoe.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams.
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main ’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x 28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting
Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all T sections shall be pre-painted with polyester baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
20 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
12 mm cement plaster of mix :
1:6 (1 cement: 6 coarse sand)
Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.
12 mm cement plaster
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
Old work (one or more coats)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work.
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
Old work (One or more coat applied @ 0.90 ltr/10 sqm).
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:
White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
10 litre capacity - White
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Semi rigid pipe 32 mm dia
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
Rectangular shape 453x357 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
25 mm nominal outer dia .Pipes.
32 mm nominal outer dia .Pipes.
40 mm nominal outer dia .Pipes.
50 mm nominal outer dia .Pipes.
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
25 to 40 mm nominal bore
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
15 mm nominal bore with 45 cm length.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design :
150 mm diameter S.W. pipe
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:
100x100 mm size P type
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps :
100 mm diameter
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Extra for depth for manholes
Size 90x80 cm
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :
For pipes 100 to 250 mm diameter
Dismantling of manhole including R.C.C. top slab, C.I. cover with frame, including stacking of useful materials near the site and disposal of unserviceable materials within 50 m lead as per direction of Engineer-in-Charge :
Rectangular manhole 90x80 cm and 45 cm deep
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter.
The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note :- (1) The elevational area of the scaffolding shall be measured for payment purpose.
(2) The payment will be made once only for execution of all items for such works.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge.
(Note: Stainless steel butt hinges and necessary S.S screws shall be paid separately)
30 mm thick
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (Note - item to be applicable in urban areas having directions for restricted hours for movement/ plying of load carrying motor vehicle of 3.5 cum or more.)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 5.0 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: complete as directed by the Engineer in charge.
15 mm nominal bore.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
Of area 3 sq. metres and below
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Old work (One or more coats)
P/F PVC MULTI FLOOR TRAPS of approved brand and manufacture; 110mmx75 mm including breaking open and removing the damaged floor trap and making good the same with white cement all complete as directed by Engineer-in-Charge.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Single socketed pipes (TYPE-B)
50 mm dia
75 mm dia
110 mm dia
Providing and fixing unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC (SWR) pipes conforming to IS : 13592 Type B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
75 mm dia bend
110 mm dia bend
160 mm dia bend
75 mm dia bend with door
110 mm dia bend with door
75 mm dia Tee with door
110 mm dia Tee with door
75 mm 'Y' with door
110 mm 'Y' with door
75 mm vent cowl
110 mm vent cowl
Providing and filling light weight cinder in sunken portions etc. complete as per directions of E-I-C (Nominal size 20mm)
Providing and laying Ceramic matfinish floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red, Brown laid on 20 mm thick CementMortar 1:4 (1 Cement : 4 Coarse sand) including pointing the joints with white cementand matching pigment etc., complete. as directed by the Engineer in charge.
Removing and refixing the PVC door shutter after removing the damaged hinges and fixing with new butt hinges etc complete as directed by the Engieer in charge.
Providing and fixing stainless steel grating with or without hole for waste pipe for covering existing floor/nahani trap
100 mm dia
Providing and fixing aluminium louver set to the aluminium frames with screws etc complee as directed by the Engineer in charge.
Removing the damaged rain water pipe by dismantling the brick work,concrete and fixing rain water pipe with necessary concrete 1:2:4 ( onw cement :two coarse sand: 4 stone aggregate 20mm) for 0.6x0.6m 50mm thickness with necessary water proofing compound finished with 12mm cement plaster 1:3 (1 cement :3 fine sand) and a coat of necement cement rounding the edge and making and fininishing the outlet complete.( Note: cost of rain water pipes shall be paid for separately.Te approximate area of concrete to dismantled is 0.5 sqm)
Dismantling FRP sheet from roof frames (of area up to 5 sqm) including removing the j bolt and stacking of serviceable material and disposal of unserviceable material with in 50m lead
Pruning, trimming, of tree branches including removal of cut materials upto 50mt. lead and as per direction of officer in charge (necessary T&P shall be arranged by the contractor).
(height Up to 15 feet) and girth up to 30 cm
Providing and fixing 15 mm Heath faucet of C.P brass head and P.V.C connection pipe of approved make etc. complete as per the directions of Engineer-in-Charge. Cost includes removal of non-funtional/worn-out health faucet.
Providing and fixing two in one tap including fittings of approved make etc. complete as per the directions of Engineer-in-Charge.Cost includes removal of non-funtional/worn-out 2 -in- 1 tap.
Arresting leakage in walls by applying brush bond or equivanet over the plastered surface etc. complete as per directions of the Engineer-in-charge.
Providing necessary repairs to the damaged MS windows/doors by removing the door shitter (either by cutting/ burning the hinges using gas welding machine at site or by removing the shutter after removing the screws and butt hinges as the case may be) and refixing the door in original position after removing the bend/ undulations in the door (members either horizontal or vertical or replacing the member it self (if required) including making good the damaged portion with necessary enamel painting (two or more coats over a coat of steel primer) all complete as per the directions of Engineer in charge. Note: The approximate door area to be repaired shall be 2.5sqm (2) The cost of MS sections if used shall be paid separately.
MS DOOR Shutters upto 2.5 Sqm area
Window Shutters upto 1.5 Sqm area
Providing and fixing Stainless steel towel rail complete with brackets fixed to wooden cleats with C.P. brass screws with two C.P. Brackets
600x20mm complete as per direction of Engineer in charge.
Providing and fixing 15mm C.P Brass pillar taps of approved quality conforming to IS. Standard and weight not less than 650 grm .
15mm nominal bore
Arresting leakage in walls including cutting the cracks in proper shape, raking out joints and filling the cracks using crack filler (Roff or equivalent) width up to 20 cm etc complee as per the directions of the Engineer-in-charge.
Providing and fixing under ground PVC pipes (Eco drain or equivalent confirming to IS 15328 4kN/sqm) including fixing it in position using SWR solvent cement ,all complete as directed by Engineer-in-Charge
160 mm dia
Necessary grouting of worn-out glazed/ceramic tile joints in flooring and dado with a mixture of white cement admixed with water proofing compound with matching colouring pigment including pointing and rounding the edges wherever required and cleaning the area with mild acid before pointing ,all complete as directed by Engineer-in-Charge
Providing and laying 2 mm thick POLYVINYL CHLORIDE (PVC) SHEET on a smooth & damp proof base using rubber based Adhesive (@ 0.2 kg/sqm) of approved quality and manufaturer like Dunlop S-758, Fevicol SR-998 or equivalent including cleaning, levelling, drying of the base, rolling with light wooden roller weighing about 5.00 kg all complete as per specification and the directions of the Engineer-in-charge.
Dismantling of wash basin/urinal/Indian type /European water closet including fittings and stacking serviceable materials and disposal of unserviceable up to 100 m lead etc. complete as per the direction of Engineer in charge(Note: serviceable materials shall be handed over to concerned authority of SATCOM bldg. with acknowldgement.
Dismantling of water supply/sanitary fittings like taps,angle cock,stopcoc k,pillar cock mirrors up to 1sqm,towelrails etc of cy size including stacking of useful materials near the site and disposal of unserviceable materials with in 50m lead.
Providing and fixing CPVC gate valve with CPVC handle of approved quality
Credit to the department by the Contractor for taking (a) dismantled damaged / defective C.P Brass/Brass/Gunmetal fittings such as ,Bib cocks , stop cocks, angle cocks, gate valves , ball cocks , waste couplings , towel rail , towel ring, Shower rose and other items identified by Engineer-in-charge.
Taking out existing damged floor spring of aluminium door shutter, etc. as required, all complete as per the direction of the Engineer-in-charge.
Cleaning of structural glazing around lift chamber in SATCOM building etc complete as directed by the Enmgineer in charge.(Note: cost includes scaffolding charges, labour charges and cost of cleaning materials, T&P and nothing extra will be paid on any account).
Providing necessary repairs to the damaged Aluminium doors by removing the door shutter by removing the screws and butt hinges as the case may be) and refixing the door in original position with new butt hinges after removing the bend/ undulations in the door (members either horizontal or vertical or replacing the member it self all complete as per the directions of Engineer in charge. Note: The approximate door area to be repaired shall be 2.5 sqm
Providing and fixing black reflective sun control film of thickness 0.16 mm of approved quality including cost of material and labour charges etc. complete as directed by the Engineer in charge.
Greasing of rolling shutter after cleaning and applying diesel with brush in the lath joints, guiding channels of roling shutters, opening MS cover and applying diesel in the inser gap of guide channe, U-clamps of rolling shaft, springs etc. cleaning excessive rust with wire brush, finally applying grease to make shutter operation smooth and refitting of MS cover etc. complete as directed (shutters shall be enumerated for payment)
Dismantling gully trap etc complete as directed by the Engineer in charge.
Supplying and installing Full back chair with knitted fabric with gas lift and tilt lock with fixed arms of Godrej Interio prime (Product Dimensions 76.1D x 76.1W x 108H Centimeters ) or equivalent approved by the Engineer in charge of required colour complete as per manufacturers speciications and directions of Engineer in charge.
Cleaning of entire toilet portion with very mild acid/approved soap solution and , cleaning of dados and flooring including cleaning wash basin, urinals, water closet etc. complete as per the direction of Engineer-in-charge.
Dismantling PVC /SWR pipe of dia up to 160mm up to floor five level etc. complete as directed by the Engineer in charge
Supplying and installing executive chair with gas lift and tilt lock with fixed arms of Godrej (Model BRAVO mid back chair NO.FU9u02R) or Featherlite or equivalent approved by the Engineer in charge of required colour complete as per manufacturers speciications and directions of Engineer in charge
Removing the damaged/worn out PVC flooring laid over existing flooring and cleaning the existing floor surface (upto floor five level) by neatly brooming, washing and mopping the floor so as to remove dust, dirt, sticky and oily substances, stains etc., from the floor surface, removing and dumping the accumulated rubbish at a identified location in ground floor upto any lead within the city exchange campus as directed by Engineerin-charge complete.
Repairs to false flooring by removing the old damaged flase flooring tiles and fixing available flooring tiles etc complete as directed by the Engineer in charge
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .