Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.1 LAccepted-AOC NO 26 SRI GANESH 7TH CROSS BDS NAGAR DIBBUR RAMAIAH LAYOUT K NARAYANPURA MAIN ROAD BANGALORE 560 077 | BENGALURU URBAN | KARNATAKA | 560077 | L1 | Accepted-AOC Lowest Bid Value | |
| 2 | L2₹42.8 L+₹1.4 L (3.39%)Rejected-AOC 57 7 MEGHNAD SAHA SARANI PRADHAN NAGAR SILIGURI 734 403 DIST DARJEELING | SILIGURI | DARJEELING | WEST BENGAL | 734403 | L2 | Rejected-AOC Higher Bid Value | |
| 3 | L3₹45.9 L+₹4.5 L (11.0%)Rejected-AOC 66 C O J R NAICKER ASWATHNAGAR SANJAYNAGAR P O BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC Higher Bid Value | |
| 4 | L4₹46.8 L+₹5.4 L (13.1%)Rejected-AOC 15 MOULYA NMH LAYOUT 1ST STAGE CHIKKA BANAVARA POST BENGALURU 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L4 | Rejected-AOC Higher Bid Value | |
| 5 | L5₹47.7 L+₹6.3 L (15.2%)Rejected-AOC | L5 | Rejected-AOC Higher Bid Value |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
19 Jun 2021, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
SPECIAL REPAIRS TO SUNKEN FLOOR AND CONNECTED B/R AND E/M WORKS IN AIRMEN TOILETS AND SPECIAL REPAIR TO ROOF TREATMEN IN CERTAIN OTM ACCN AND CERTAIN MINOR WORKS AT HQTC BANGALORE
2021_MES_444771_1
8790/GE/30
Open Tender
Civil Works
Item Rate
180 days
HQ TC BANGALORE
as per NIT
5 documents required · 5 mandatory
₹500
Yes
GE (AF) BANGALORE
₹96,000
Yes
7 Sept 2021
21 May 2021
21 Jun 2021
21 May 2021
19 Jun 2021
7 Jun 2021
22 May 2021 - 31 May 2021
Amount
Surface excavation n.exc 30 cm deep and averageing 15 cm deep and getting out in soft/loose soil complete all as directed.
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth, for foudation etc, or for shafts, wells cesspits, manholes, pier holes etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil.
Excavation in trenches not exc 1.5m wide and not exc 1.50 mtrs in depth for foundations etc and getting out in hard/dense soil complete all as specified & directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft / loose soil complete all as directed.
Excavation in post holes in hard/dense soil for similar holes) each n.exc 0.5 Cum getting out, returning, filling in and rammig earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and all as specified and directed.
Removing excavated material (soil) not exc 50m and depositing where directed at a level not exc 1.50M above the starting point complete all as specified and directed.
Removing excavated materials out side MoD land exc 5Km and depositing where directed at a level not exceeding 1.5m above the starting point in soft/loose soil.
Material & labour Hard core, broken stone/boulders to gauge n exc 63 mm complete all as directed.
M&L PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) foundation fillings and mass concrete complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as foundation filling or mass concrete complete all as specified
M&L cement concrete 1:2:4, type B1 (20mm graded stone aggregate) as in padding over roof, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified
M&L for Pre-cast cement concrete block type C1 1:3:6 (20mm graded stone aggregate) masonry with solid blocks, exc. 10cm in width and setting in mortar 1:6 complete all as specified
M&L for providing precast cement concrete solid building blocks type C1 1:3:6 (20mm graded aggregate) 10cm thick (with plain or interlocking joints as directed) setting in mortar 1:4, complete in walls all as specified and directed.
M&L Providing precast cement concrete solid building blocks or slabs 10cm thick of Type C1 1:3:6 (20mm graded aggregate) (with plain or interlocking joints as directed) setting in mortar 1:6, complete, in walls complete all as specified
M&L for RCC (nominal mix) type B1 1:2:4 (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for coloumns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC (nominal mix) type B1 1:2:4 (using 20mm graded stone aggregate) in columns, pillars, piers, posts and struts complete all as specified and directed.
Cutting channels, grooves or rebates n exc 15cm girth, in stone wall and trimming surface without re-inforced and surface finish with CM 1:3 complete all as directed.
Cutting holes into or through cement concrete slabs, chajjas, etc. reinforced or otherwise superficial area n. exc. 100 sqcm and surface finished with CM 1:3 complete all as directed.
Supply only liquid water proofing compound.
Cutting chases, pinning in Stone concrete block or slab walls making good to facings where required and pointing in ement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed.
Use and waste of form work to sides of pillers, posts, struts,piers, columns and stanchions for rough finished flat surfaces of concrete, square, rectangular or polygonal, complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified
S&F solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing. (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
S&F factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site etc. complete all as specified and as directed.
S&F 100mm long Butt hinges, medium weight, cold rolled mild steel complete all as specified.
S&F for 125mm aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified.
S&F 125mm Aluminium handles, cast type anodised complete all as specified.
S&F 150mm long aluminium alloy, anodised, sliding door bolts with hasp, staple (bolt type) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc. complete all as specified and as directed by Eng-in-Charge.
S&F in repairs Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified
M&L Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; railings; and similar work conforming to Fe.290.Gde-E-165 complete all as specified
Material & labour Bands, straps, supports or stays for rainwater, ventilating pipes,including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges:large hasps and staples; chains; hand made sliding bolts; clamps;hold fasts; wall ties; hooks forhanging fans; plain angle cleats for securing purlins to woodtrusses or rafters; knee pieceinserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 etc complete all as specified & directed
S&F 1.60mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified & directed.
M&L TMT Bars 10mm dia and over, cut to length, bent to shape required, inculding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (ennealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Ditto, all as per item No 35 here in above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Supply & fix MS work for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290 (Gde E-165) complete all as specified & directed.
S&F of steel work in tubular trusses including special shaped washer etc. Complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed.
S&F Steel windows or ventilators, fixed type, with glazing bars complete all as specified
Resecuring or easing & adjusting steel window without taking down Shutters of any description and any size complete all as specified.
Welding in repairs n. exc 2.5cm in length, n.exc 6mm thickness of metal to be welded. complete all as specified
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/in ridges, fixed with self tapping screws as specified and directed.
M&L for water proofing treatment on horizondal or vertical surfaces by applyong oil bound bitumen primer & 0.20 Kg/Sqm and providing 4 mm thick APP modified water proofing membrane weighing not lesss than 4 Kg/Sqm reinforced with non-woven polyester matt weighing not less than 160 gm/sqm having softning point not less than 150 centi grade havinf tensile strength of 650 N /5cm and 350N/5cm in longitudinal and transfers direction recpectively of the reinforcement tearing strength of 180N by torch on application including minimum 10 cm side lap and 15 cm end lap torch sealed and bonded and ove membrane finished with solar reflective bituminus aluminium paint/primer @ 0.1 Kg/Sqm over RCC roof slab/ projection/ parapet after cleaning the surfaces by removing dust dirt etc as manufactures instructions including Taking down old damaged existing water proofing membrane of any thickness from roof top complete all as specified and directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations. complete all as specified and directed.
M&L for sunken slab treatment comprising of following :- (a) Taking out/down old existing sunken slab treatment and cleaning the old RCC surfaces of sunken slab including removal of the rubbish out of campus complete all as specified and directed. (b) M&L for 25mm thick PCC type B1 1:2:4 (Using 20 mm graded stone)aggregate over cleaned sunken slab surfaces. (c) M&L for applying bituminus priming coat/tack coat coat over PCC surfaces @ 0.30Kg/Sqm of surfaces. (d) M&L for 4mm thick APP modified water proofing membrane weighing not less than 4 kg/sqm reinforced with non woven polyster mat weighing not less than 160 gm/sqm including minimum 10cm lap torch sealed and bound. (e) M&L for applying bitumen grade 85/25 over primer coat @ 1.20 Kg /Sqm (f) M&L for 15 mm thick plastering in CM 1:4 mixed with liquid water proofing admixure as per manufactures instructions complete all as specified and directed by Engr-in-charge. (Note : WPC shall be measured and paid separately)
M&L 75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection, path etc finished the surface even & smooth without using extra cement complete all as specified
M&L 75mm thick PCC 1:4:8 type C-1 (using 20mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 (40mm graded aggregate) as in sub-base layer.
M&L for 75 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in flooring even and smooth finish with using extra cement all as specified.
M&L for 100 mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) as in flooring even and smooth finish with using extra cement all as specified.
M&L for 25mm thick Cement concrete type B-0, 1:2:4 (12.5mm graded stone aggregate) as in flooring all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etcRoughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc including Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as directed.
M&L for Glazed ceramic coloured tiles stone finish in vertical surface 350x250x7mm/450x350x7mm thick such as skirting, dados etc, set and jointed in neat cement slurry and pointed with white or colour cement to match over and including 10mm thick screed plaster in cement mortar 1:4 complete all as specifed.
M&L for non skid Ceramic tiles coloured 7 to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 sqm each, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick Screed bed or bedding layer in cement mortar CM 1:4 for laying floor tiles as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L for 10mm rendering CM 1:3, mixed with liquid warer proofing admixture as per manufacturer instructions on concrete surface in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified & directed.. Note: Liquid WPC shall be measured and paid separetaly)
Rendering 5mm thick cement plaster in cement morter 1:3, on concrete sufaces as in ceiling, finished even and smooth without using extra cement complete all as specified.
M&L for rendering 15mm thick cement plaster in cement morter 1:4 with and including water proofing compound @ 2% by wt. of cement, on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
M&L for 15mm thick rendering on brick wall or concrete surface in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified & directed.
M&L for 15mm thick rendering on brick wall or concrete surface in cement mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified & directed.
Taking down cement or cement lime plaster, any description on brick or stone walls, or roof top etc. Including racking out joints, hacking for key, scrubbing down with water, etc. all as specified. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
M&L for Rendering 15mm thick on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing in CM 1:6 and finished even and smooth without using extra cement all as specified.
M&L for rendering 15mm thick cement plaster in cement morter 1:4 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing, finished even and smooth without using extra cement complete all as specified. Note: WPC will be measured and paid separately.
M&L for preparation of old decorated plastered or unplastered surface of walls including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of white washing complete.
All as per item No 63 here-in-before but one coat of white washing on ceiling complete all as specified.
M&L for preparation of new plaster surface of walls and applying three coats of white on walls complete all as specified and directed
M&L for preparing new plastered on ceiling and applying three coats of white wash complete all as specified.
M&L for 2 coats of cement paint over a coat of priming plastered and other surfaced with alkali resistant priming paint including preparation of new surfaces all as specified.
S&F 4 mm thick Sheet glass, ordinary quality, ground or obscured or frosted, on one side and glazing with oil putty in square n exc 0.5 sq. m in each pane, etc. complete all as specified and as directed.
Preparation of old painted surface of any description not otherwise described wood and wood based surfaces over 10 cm width of girth and applying one coat of synthetic enamel paint complete all as specified.
M & L preparation of new or previously untrated steel surface of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer all as specifed and directed.
Preparation of old painted surface of any description not otherwise described steel and iron surface over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
S&F in repairs Grating doom 100 - 125mm dia with or without waste hole of stainless steel complete all as specified.
S&F in repairs 15mm Bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified.
S&F in repairs 15mm two in one Bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified.
S&F in repairs stop valve 15mm bore, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed all as specified.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm all as specified.
S&F in repairs Low density polyethylene (LDPE) pipes 32mm dia, of pressure rating 6 kgf/sq. cm fixed complete to walls, ceilings or in floors etc. all as specified
S&F in repairs PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F in repairs PVC (SWR) pipes 110mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified.
S&F in repairs PVC (SWR) pipes 150mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified.
S&F 110 mm bore PVC (SWR) Junction single (Single T) equal or unequal all as specified.
S&F 110 mm bore PVC (SWR) branch piece single (Single Y) equal or unequal all as specified.
S&F 110mm bore PVC (SWR) bends of any radius all as specified.
S&F in repairs 150mm bore PVC (SWR) bends of any radius all as specified.
S&F PVC (SWR) bends 110mm bore vent cowl complete all as specified
S&F PVC (SWR) 'P' or 'S' trap 110mm bore complete all as specified.
S&F in repairs PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified
S&F in repairs PVC (SWR) pipes 75mm bore, single socketed, in any length with rubber ring joints, fixed to wall complete all as specified.
S&F 75 mm bore PVC (SWR) Junction single (Single T) equal or unequal all as specified.
S&F 75 mm bore PVC (SWR) branch piece single (Single Y) equal or unequal all as specified.
S&F 75mm bore PVC (SWR) bends of any radius all as specified.
M&L for cutting into existing manholes for connecting new drains, making good to 100mm pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required complete all as specified.
S&F in repairs Brass chromium plated shower rose 125mm size all as specified.
S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified.
S&F in repairs Soap dish, any type of size approximate size 160x 60x90mm, fixed to plugs with chromium plated brass screws complete all as specified.
S&F in repairs 15mm pillar tap,cast copper alloy, with capstan head, chromium plated, fancy type screwed down high pressure,with or without lettered "Hot" or "Cold" with long screwed shank and fly-nuts, screwed for iron pipe and fixed all as specified.
S&F in repairs premium quality wall mixer system with provision for overhead shower complete with 115mm long bend pipe, connecting Legs & wall Flange complete all as specified. Make Jaguar, Cera, Somany or equivalent.
S&F in repairs Hand Shower (Health Faucet) with 8mm dia, 1Meter Long Flexible Tube & Wall Hook complete all as specified. Make Cera, Parryware, Somany, Jaguar or equivalent.
S&F in repairs wash basins, Vitreous China white,(flat back type) size 550x400mm, pedestal type, excluding taps, waste, chain and plug and porcelain stopper but including brackets, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe etc. complete all as specified and as directed.
S&F in repairs vitreous china wash down water closet pan (pedestal pattern), including 10 ltr PVC flushing cistern, flush pipe, plastic water closet seat, white or tinted, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white or tinted, with integral foot rests including 10 ltr PVC flushing cistern and flush pipe complete all as specified.
S&F in repair Vitreous China urinals,half stall urinal type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe), etc. complete all as specified and as directed.
S&F in repairs curved shaped frameless urinal partition with 8mm thick frosted toughened glass of size 450mm x 900mm with CP brackets 04 Nos etc. complete all as specified and as directed.
S&F in repairs PVC flexible Waste pipe 32mm dia and 750mm long etc. complete all as specified and as directed.
S&F UPVC 15mm internal dia pipe of pressure rating 10kgf/cm² fixed complete to walls, ceiling or in floor etc.,complete all as specified including taking up or down old pipe.
All as item No 106 above but 20mm bore
All as item No 106 above but 25mm bore
Forming Construction joint 40mm deep x 10mm wide filled with sealing compound grade 'A' all as specified and as directed.
Demolition of re-inforced cement concrete in ground floors (below or above ground level)l complete all as specified & directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dresses stonework and precast concrete articles. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Demolition of unreinforced concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations.
Dismantling wrought iron or mild steel work of any description not otherwise provided for etc. complete all as specified and as directed.
Dismantling structural steel work of any description including fencing,doors, gates, plain black sheets of any description and angle iron swan neck etc complete all as specified.
Removing old dumped junk/ building materials/ debris/ tree roots, trunk, & branches of any size etc. to a distance of 30Km or beyond, out of premises of metropolitan area, including loading, unloading by manually or by mechanical means (JCB) and to be transported through tractor-trolly or tipper and stacking at the destination complete all as specified.
Taking down carefully copper/aluminium point wiring (light fan socket or power) complete including fittings such as switches, ceiling rose, pendants, regulators, sockets, light fitting and removing retrieved materials and making good the disturbed surface, complete all as specified and directed
Taking down existing light fittings of any description from wall/ ceiling including keeping in safe custody by making good the disturbed surfaces of walls, compete all as specified and directed.
Taking down Exhaust fan, dismantaling blades, and removing fan including painting and refix the same including connecting up and provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
Point wiring with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with copper conductor drawn in and incl heavy grade PVC casing caping ISI marked including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor branded PVC moulded modular gang box fixed on wall surface with Modular suitable plate with cover and suitable screws for housing switches socket outlets fan regulators etc., all as specified and directed. Make:- .Finolex / Ravi Cab / NICCO or equivalent make.
One light/Ceiling fan point controlled by one single pole 5 Amps switch
One switch socket out let point 5 Amps on independent board
One switch socket out let point 5 Amps on same board with other switches
All as per item No 4 above but with copper conductor cable FLRS 4.0 sqmm for one 3 pin socket outlet,15 Amps and including provision of 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor on independent board, complete all as specified and directed.
Switch piano flush type single pole one way 6 Amps, complete all specified and directed.
Switch socket combination outlet 5pin multi purpose 5 Amps flush type, complete all as specified and directed.
Switch socket combination outlet 6 pin 5&15 amps multi purpose flush type universal pattern 230 v, complete all as specified and directed.
Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket with single pole MCB 20 Amps 240 Volts AC, complete all as pecified and directed
PVC ceiling rose 65 x 50 mm surface type with 3 terminals, complete all as specified and directed.
Exhaust fans turbo force sp of size 450mm sweep, AC single phase 230/ 240 V of metallic body with louver and other accessories, complete all as specified and directed.
LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts , 2500 Lumens, efficiency > 110, CCT 6500k , CRI > 80 , Wall / surface mounted , IP 20 aluminium etrusion housing complete with including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting, complete all as specified and directed. Make: Havells Catalogue No. LHEXBXPNIN1W020, Wipro Catalogue No. LL20-111-XXX-57-XX) or equivalent make.
LED batten luminaire surface mounted 2 feet system wattage of 10 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained, complete all as specified and directed. (Make: Havells Catalogue No. LHEXBXPNIN1W010, Wipro Catalogue No. LL20-111-XXX-57-XX) or equivalent make.
sub main wiring with Two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 6 sqmm in and including non-metallic rigid PVC casing and capping and accessories and fixing arrangements fixed to surface on wall, floor or ceiling etc including 6 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly, fixed as in repairs, complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC casing capping and two run of copper conductor together taken as one length for measuring unit length.
Sheet metal enclosure MCB DB double door type 230v with suitable bus bar for SPN 4 ways model, complete all as specified and directed
MCB SPN 32A, upto rupturing capacity of 10KA, C curve type, complete all as specified and directed.
MCB SP 06 to 32A, upto rupturing capacity of 10KA, C curve type fixed in PVC Cable loop box, complete all as specified and directed.
B.B. Enterprise
OM Enterprises
Moulya Builders
Raashi Constructions
TANCARE HYGIENE AND HEALTH CARE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .