Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.5 LAccepted-AOC 15 EMERSON ROAD DANAPUR CANTT PATNA 801101 | PATNA | PATNA | BIHAR | 801101 | L1 | Accepted-AOC ok | |
| 2 | L2₹20.4 L+₹86,035 (4.40%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
22 Feb 2022, 6:00 pmClosed
GE (AF) Bihta
GE (AF) Bihta PIN 801103
Repair/maintenance/replacement of unsv DG Set Spares, AMF Panels, Solar water heaters and pipe lines and connected works at AFS Bihta
2022_MES_503583_1
8193/BHT/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Bihta
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) Bihta
₹44,000
Yes
26 Mar 2022
25 Jan 2022
28 Feb 2022
25 Jan 2022
22 Feb 2022
8 Feb 2022
Amount
Inspection, maintenance and servicing including Alternator of connected DG set 75 KVA make Kirloskar excluding AMF panel installed at AF Net site 1 for routine check up [once in two months / A - check] of the engine for the smooth functioning and carrying out the complete as per the Manufacturer's instructions all as specified and directed by Engr-in-Charge. A - Checks (Item Nos. 1 to 12). (i) Check Engine oil level and topping up as and when required [Engine oil will be measuered paid separately] (ii) Check Engine Coolant oil level, if required topping up. [Coolant oil measured and paid separately] (iii) Check Belts if there is belt slippage adjust or replace. (iv) Check oil bath cleaner oil level. (v) Check Exhaust System for leakage and rectification. (vi) Drain sediment and cleaning from Fuel filter & Fuel Tank. (vii) Check dry type air filter element and clean or replace [Air filter element shall be measuered paid seperately].
(viii) Check engine alternator coupling and mounting bolts. (ix) Tight all bolts and nuts in Alternator Terminal Box. (x) Check carbon brushes [Brush type] and connections in Alternator. (xi) Check and tight all Electric connections in DC control wiring. (xii) Check all Radiator rubber Hoses, record oil pressure, water and oil temp. (xiii) Record RPM, Voltage, Amps and Hz. (xiv) Check Anti Vibrating Mountings. (xv) Check throttle linkages. (xvi) Check starting battery electrolyte level, specific gravity and topping up if required.
All as per item No 1 above but DG set of cap 75 KVA make Kirloskar installed at AF Net Site 2 all as specified and directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 62.5 KVA make Kirloskar installed at pump house No 3 and all as directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at P H No 2 and all as directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 40 KVA Make Sonilika installed at Tropo perimeter SS No 2 and all as directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at ATC sub station (Alt) and all as directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 40 KVA Make Sonilika installed at Sub station No 5 (W/T) and all as directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 40 KVA Make Cummins Jakson installed at ATC S/S and all as directed by Engr-in-Charge.
All as per item No 1 above but DG set of cap 25 KVA Make Cummins Jakson Installed at Main Guard room and all as specified and directed by the Engr-in-Charge.
All as per item No 1 above but DG set of cap 25 KVA Make Cummins Jakson Installed at Main Sub Guard room and all as specified and directed by the Engr-in-Charge.
All as per item No 1 above but DG set of cap 15 KVA Make Cummins Jakson Installed at Sub stn No 2 (Tropo) and all as specified and directed by the Engr-in-Charge.
All as per item No 1 above but DG set of cap 15 KVA Make Cummins Jakson Installed at 10 ASC and all as specified and directed by the Engr-in-Charge.
Inspection, maintenance and servicing of DG set 75 KVA installed at AF Net site 1 including Alternator, excluding AMF panels connected to DG sets for routine check up (B - check once in 6 months or 300 running hours whichever is earlier all 'A' checks included in the 'B' check deemed to be quoted rates) of the engine for the smooth functioning and carrying out the complete B-check as per Manufacturer's instructions including replacement of diesel primary filter, microfilter, engine oil filter and repairs to oil pump etc., all as specified and directed by Engr-in-Charge. Note : Engine oil & Coolant oil will be measured and paid separately.
All as per item No 13 above but DG set of cap 75 KVA installed at AF Net Site 2 all as specified and directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 62.5 KVA installed at pump house No 3 and all as directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 40 KVA installed at P H No 2 and all as directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 40 KVA installed at Tropo perimeter SS No 2 and all as directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 40 KVA installed at ATC sub station (Alt) and all as directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 40 KVA installed at Sub station No 5 (W/T) and all as directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 40 KVA installed at ATC S/S and all as directed by Engr-in-Charge.
All as per item No 13 above but DG set of cap 25 KVA Installed at Main Guard room and all as specified and directed by the Engr-in-Charge.
All as per item No 13 above but DG set of cap 25 KVA Installed at Sub Guard room and all as specified and directed by the Engr-in-Charge.
All as per item No 13 above but DG set of cap 15 KVA Installed at Sub stn No 2 (Tropo) and all as specified and directed by the Engr-in-Charge.
All as per item No 13 above but DG set of cap 15 KVA Installed at 10 ASC and all as specified and directed by the Engr-in-Charge.
Supply only engine oil SAE 20W-40W. Make: Volvoline / IOC
Supply & filling radiator coolant Make: Volvoline / IOC
Servicing & Maintenance of AMF panels (Once in two months) pertains to 75 KVA DG SET installed at AF Net site 1 for smooth functioning including repairs to the unserviceable ammeter, voltmeter, oil pressure sensor, push buttons, indicator lamps, relays, control fuse and replace minor parts like, cleaning & servicing all contact points etc complete all as directed by Engr-in-Charge. Note : Spares such as power contactors, ACB timers, Multi Display Meter, Battery charger etc. shall be measured & paid separately under "SUPPLY ONLY" item.
All as per item No 27 above but DG set of cap 75 KVA installed at AF Net Site 2 all as specified and directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 62.5 KVA installed at pump house No 3 and all as directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 40 KVA installed at P H No 2 and all as directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 40 KVA installed at Tropo perimeter SS No 2 and all as directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 40 KVA installed at ATC sub station (Alt) and all as directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 40 KVA installed at Sub station No 5 (W/T) and all as directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 40 KVA installed at ATC S/S and all as directed by Engr-in-Charge.
All as per item No 27 above but DG set of cap 25 KVA Installed at Main Guard room and all as specified and directed by the Engr-in-Charge.
All as per item No 27 above but DG set of cap 25 KVA Installed at Main Sub Guard room and all as specified and directed by the Engr-in-Charge.
All as per item No 27 above but DG set of cap 15 KVA Installed at Sub stn No 2 (Tropo) and all as specified and directed by the Engr-in-Charge.
All as per item No 27 above but DG set of cap 15 KVA Installed at 10 ASC and all as specified and directed by the Engr-in-Charge.
Removing the self starter 12 Volt DC from the engine of 15 to 75 KVA DG sets and taking to work shop for rewinding of armature / field including replacement of brush and bush and refixing the same to the engine and testing all as directed by Engr-in-Charge.
Supply only for the following spares for executing Sl item Nos. 27 to 38 (suitable for 15 to 75 KVA DG sets) :-
Supply only 12 V DC stopping solenoid
Supply only Water Temp gauge with adapter.
Supply only Oil Temp gauge with adapter.
Supply only Oil pressure guage with pipe.
Supply only AC / DC Timer.
Supply only PLA Relay with Base.
Supply only Volt meter DC.
Supply only Ammeter DC.
Supply only Battery 12 Volts.15 Amps 74 AH
Supply only Relay suitable for Kirloskar Make DG Set 62.5 - 75 KVA (existing type & voltage -24/12 Volts) in AMF panel and making connections including testing complete all as directed. Make : L&T, Siemens or equivalent
Supply only Relay suitable for Kirloskar Make DG Set 40 KVA (existing type & voltage -240 Volts AC) in AMF panel and making connections including testing complete all as directed. Make : L&T, Siemens or equivalent
Supply only SMPS unit suitable for DG Set 62.5 - 75 KVA capacity for battery charging including making connections and testing etc complete all as specified and directed. Note : The SMPS shall only be purchased from the authrised dealer.
Taking out unserviceable power contactor and supply and fixing power contactor suitable for AMF panel pertains to DG Set 40 to 75 KVA capacity. Make : TC,LC1FDP 3304A
Supply and fix in repairs Air filter element as per existing make for 62.5 to 75 KVA DG Set installed at location shown in serial Nos 1 to 3 above
Supply and fix in repairs Air filter element as per existing make for 40 KVA DG Set installed at location shown in serial Nos 4 to 8 above
Supply and fix in repairs Air filter element as per existing make for 15 to 25 KVA DG Set installed at Serial Nos 9 to 12 above
S&F dynamo fan belt set suitable for for DG Set 62.5 to 75 KVA Make : Kirloskar (2.00 to 2.50 for belts) Make: - Kirloskar/ Power king/ Power grip GTX / Dunlop
S & F dynamo fan belt set suitable for DG Set 15 to 40 KVA Make : Cummins Jakson
S & F in repair water pump suitable for 62.5 to 75 KVA DG Set Make : Kirloskar, Make : Kirloskar /Power king/ Power grip GTX/ Dunlop
S & F in repair water pump suitable for DG Set 40 KVA Make : Cummins Jakson
S & F water hose pipe set with clamps suitable for 62.5 - 75 KVA DG Set Make : Kirloskar
S & F water hose pipe set with clamps suitable for 40 KVA DG Set Make : Cummins Jakson
S & F in repair Auxiliary contact suitable for Kirloskar make DG Set 62.5-75 KVA (existing type) with logic units. Make : L&T/Legrand/ Havells/ Siemens
S & F Main contactors four pole, 220 Volt suitable for 75 KVA DG set of existing model complete all as directed. Make - L&T/Havells/legrand etc
M&L for preparation of old surfaces of aquastic enclousers, cleaning dust, dirts, etc. filling cavities with filler compound and applying two coat of DUCCO paint with existing colour by using spray machine gun including writting SM / MES No with white paint complete all as specified and directed.
M & L for replacement of damaged AMF panel wiring with 1.5 / 2.5 Sqmm copper conductor FRHS as per existing including replacement of cable treys of existing size and copper thimbles etc complete all as specified and directed
M & L for complete dismantling and servicing of existing unsv solar water heater and collector panel of capacity 100 ltr /day of any Make with electric back up system after disconnecting the existing water supply/water connection from any height of the building/ ground, including stripping out the hot water vessel by taking out, outer cover, insulating materials etc and continuous brazing /welding of the inner container where required for arresting leakages including replacemnt of defective /worn out spare parts etc and re-assembling the system connecting the water/ electrial connections complete and testing upto the satisfaction of Engr-in-Charge. NOTE:-(i) Cost of minor defective /worn out spares is deemed to be included in the quoted rate for this item. (ii) Cost for servicing of flat plate collector is also deemed to be included in the quoted rate. Major spares shall be measured and paid separately. (iii) Servicing of solar water heater shall be got through the authorised dealer of M/S RASHMI Idustries, Bangalore or original Equipment Manufacturer to avoid any defect.
~ ditto- all as per Ser item No 55 above but for solar water heater capacity 200 / 300 lts/day.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose / soft soil and getting out for under ground cable / erection of poles, stays etc complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick each complete all as specified and directed.
Removing of excavated material n. exc 50 m distance and depositing where directed at a level n. exc 1.5 m above the starting point complete all as specified.
M&L for precast RCC slab of 1:2:4 type B-1 using 20mm graded stone aggregate set in cement mortar 1:6 for drain / manhole/ duct cover complete all as specified and directed.
M&L for 6 - 8 mm dia TMT reinforcement bars for precast cover slab including binding wire as required complete all as specified.
M&L for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate for mass filling/ patching work in pole copping including making smooth surface matching with existing coping complete all as specified.
M & L brick work with sub class 'B' brick straight or curved on plan exc 6m mean radius, built in CM 1:4 complete all as specified and directed.
S & F in replacement of unsv / damaged GI tubing 15 mm bore medium grade with all fittings, fixtures and fixed in wall and ceiling or laid in floor complete all as specified and directed.
All as per item No 64 above but GI tubing 20 mm bore
All as per item No 64 above but GI tubing 25 mm bore
S&F in replacement of unsv /damaged hot water pipe line 15 mm bore insulated with glass wool and aluminium cladding complete all as specified and directed.
S&F in replacement of unsv / damaged gun metal globe or gate valve of following sizes with cast iron wheel head screwed both ends for iron pipe complete all as specified and diected :- (a) 15mm dia bore
(b) 20mm bore
(c) 25mm bore
S&F in replacement of unsv /damaged 15 mm bib tap cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
M & L for replacement of defective XLPE insulated screened PVC bedded galvanised steel or wire armoured electric power cable, heavy duty with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 2 core to be laid in existing cable in trenches /under road / along poles / through pipe etc complete all as specified and directed.
M & L for replacement of defective XLPE insulated screened PVC bedded galvanised steel or wire armored electric power cable, heavy duty with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 4 core to be laid in existing cable in trenches /under road / along poles / through pipe etc complete all as specified and directed.
S & F in replacement of unsv MCB DB 220 volts 4 way double door complete all as specified and directed.
S & F in replacement of unsv TPN MCB DB TPN 4 way double door complete all as specified and directed.
S & F in replacement of unsv / damaged Solar flat plate collector (Panel) for 100 LPD Non standard 1 No
S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 200 LPD Non standard 1 No and standard 1 No
S & F in replacement of unsv/damaged Solar flat plate collector (Panel) for 300 LPD Non standard 1 No and standard 2 No
S & F in replacement of broken/defective solar water heater storage tank for 100 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and directed.
S & F in replacement of broken/defective solar water heater storage tank for 200 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and directed.
S & F in replacement of broken/defective solar water heater storage tank for 300 LPD including making necessary Elect and water supply connections and testing etc complete all as specified and directed.
S & F in replacement of unsv hot water outlet hose pipe 20 / 25 mm dia of standard length.
S & F in replacement of unsv cold water inlet hose pipe 20 / 25 mm dia of standard length.
S & F in replacement of unsv / damaged heating element with rubber gasket threaded /push type, 230 Volts, 1.5 / 2 KW and making necessary electrical connections and testing complete all as directed. Make of element : Toshiba / Bajaj or equivalent.
S&F GI inter locking ring, clip type suitble for rubber pipe 15mm / 20 mm/ 25 mm dia or as directed by Engineer-in-Charge complete all as directed.
M & L for PUF Insulation/Glass wool insulation on solar hot water pipe line of any size including provision of aluminium foil and fixing with screws complete all as specified and directed.
Repair and maintenance of EOT crane 0.5 / 2.5 Ton installed at Radar by checking all mechnical and electrical equipment /system for normal working and testing with the load, if provided by user, including greasing, oiling and replacing minor spares and consumbles complete all as specified and directed to the entire satisfaction of Engineer -in - charge.
Supply and fix in repair breaker motor coil for the EOT crane 0.5 to 2.5 Ton complete all as directed.
Taking down carefully by disconnecting and unscrewing from boards/outlet boxes, electric meters of any locations and deposited to MES store yard as per bldg inventry by sub div complete all as specified and as directed.
Supply and fixing single Phase Static Energy Meters,ISI Marked, Digital Energy meter for netmetering with enclosure having capacity 5-30Amp, 240V, Accuracy Class 1.0,DLMS Compliant,Optical Port and Load survey including suitable SMC Meter Box, sealing arrangement along with 2 nos. polycarbonate meter seal and making connection and complete all as specified and as directed. Make:- Secure Model No-Saral or equivalent.
Supply and fixing Three Phase 4W Static Energy Meters,ISI Marked, Digital Energy meter for netmetering with enclosure having capacity 10-60Amp 415V, Accuracy Class 1.0,DLMS Compliant,Optical Port and Load survey including suitable SMC Meter Box, sealing arrangement along with 2 nos. polycarbonate meter seal and making connection and complete all as specified and as directed. Make:- Secure Model No-Saral 300 or equivalent.
S & F sub main wiring using approved colour coding (Phase-red,Neutral-black,Earth-green) complete with two single core FRLS PVC insulated and unshealthed stranded copper conductor cable 6 sqmm as current carrying conductor and one run of 6.0 sqmm as neutral cable ,voltage rating 1100 volt ,ISI marked drawn in and including concealed PVC conduit ISI marked of dia not less than 25 mm and thickness 2 mm with stranded accessories along with one run of FRLS PVC green colour insulated,unshealthed,stranded copper conductor of size 6 sqmm all as specified and directed including taking down old one Note:- Two run of single core FRLS PVC cable with one run of earth contunity conductor and conduit shall be measured as one unit.
PUJA ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .