Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.3 LAccepted-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹53.4 L+₹1.6 L (3.16%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹62.4 L+₹10.6 L (20.5%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹65.9 L+₹14.1 L (27.3%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | L4 | Rejected-Finance Being other than lowest |
Tender Value
₹70 L
EMD Value
₹1.3 L
Closing Date
6 Jul 2020, 6:00 pmClosed
CWE NW MUMBAI
Commander Works Engineer NW Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 05
REPAIR REPLACEMENT OF DETERIORATED FAULTY ALUMINIUM SUBMAIN WIRING WITH COPPER SUBMAIN FROM METER CABIN TO SERVICE DBS AT VARIOUS BLDGS BLOCKS UNDER GE NOFRA COLABA MUMBAI AUDITORIUM AND REPAIR REPLACEMENT OF ACS AND WATER COOLERS UNDER GE NW NA
2020_MES_348086_1
8631/CWE(NW)/MUMBAI
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE NW NOFRA
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE NW NOFRA
₹1.3 L
Yes
10 Aug 2020
29 May 2020
8 Jul 2020
29 May 2020
6 Jul 2020
22 Jun 2020
29 May 2020 - 20 Jun 2020
Amount
M&L for sub-main wiring with 2 runs of 6.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping / heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories such as tee, bends, elbow, reducers, junction box etc. as required, fixed on wall/ceiling/truss, including one run of 6.0 sqmm dia PVC insulated unsheathed copper conductor cable (FRLS grade), 1100 volts as earth dolly/mains, including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster / Plaza (c) Make of casing caping - Pressfit / Precision (d) Two runs of 06 Sqmm cable, one run of 6.0 Sqmm earth cable and one run of PVC casing Capping /conduit shall be measured as one running meter. (e) Each submain wiring shall run in seperate PVC casing caping/ conduit
M&L for sub-main wiring with 2 runs of 10.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping / heavy grade PVC conduit not less than 25mm dia (internal width) with all accessories such as tee, bends, elbow, reducers, junction box etc. as required, fixed on wall/ceiling/truss, including one run of 10.0 sqmm dia PVC insulated unsheathed copper conductor cable (FRLS grade), 1100 volts as earth dolly/mains, including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Gloster / Plaza (c) Make of casing caping - Pressfit / Precision (d) Two runs of 10.0 Sqmm cable, one run of 10.0 Sqmm earth cable and one run of PVC casing Capping /conduit shall be measured as one running meter. (e) Each submain wiring shall run in seperate PVC casing caping/ conduit
S&F in repair of SPN DB 12 Way, 240V with 100A copper busbar each phase, double door type, IP-54- IK 09 protection connecting with existing wiring circuits by providing copper pin terminals of suitable for housing MCB's all as specified and directed. Make: Legrand cat No 5076 42 or equivalent cat No. in Seimens/GE.
S&F in repair of SPN DB 8 Way, 240V with 100A copper busbar each phase, double door type, IP-54- IK 09 protection connecting with existing wiring circuits by providing copper pin terminals of suitable for housing MCB's all as specified and directed. Make: Legrand cat No 5076 41 or equivalent cat No. in Seimens/GE.
S&F in repair of SPN DB 4 Way, 240V with 100A copper busbar each phase, double door type, IP-54- IK 09 protection connecting with existing wiring circuits by providing copper pin terminals of suitable for housing MCB's all as specified and directed. Make: Legrand cat No 5076 40 or equivalent cat No. in Seimens/GE.
Supply and fix in repairs sheet metal enclosure 2 Way without bus bar with MCB comprising of suitable for housing MCB's all as specified and directed. Make: Legrand cat No 5077 91 or equivalent cat No. in Seimens/GE.
S&F in repair of vertical type VTPN DB 8 Way, 415V with 250A copper busbar for each phase with 2 neutral bar, 2 Earth bar and Cable ties for cable management, double door type, IP54- IK 09 protection suitable for housing MCB's all as specified and directed. Make: Legrand cat No 5077 52 or equivalent cat No. in Seimens/GE. NOTE FOR ITEM No. 03 to 07: MCB DBs shall be concealed in wall where ever posible including making good the surface to match with surrounding.
S&F MCCB, 3 pole, 415 Volts, fixed type, 160 Amps with breaking capacity 25 KA complete all as specified and directed. Make: Legrand cat No. 4200 47 or equivalent cat No. in Seimens/ Schneider/ GE
S&F MCB, TP 63 Amps, 10 KA (C Curve), 415 Volts complete all as specified and directed. Make: Legrand cat No 4086 61 or equivalent cat No. in Seimens/Schneider/ GE
S&F MCB, SPN 63 Amps, 10 KA (C Curve), 240 Volts complete all as specified and directed. Make: Legrand cat No 4086 20 or equivalent cat No. in Seimens/ Schneider/ GE
S&F MCB SPN 40 Amps 240 Volts, 10 KA (C Curve), complete all as specified and directed. Make: Legrand cat No 4086 18 or equivalent cat No. in Seimens/Schneider/ GE
S&F MCB SP 40 Amps 240 Volts, 10 KA (C Curve), complete all as specified and directed. Make: Legrand cat No 4085 96 or equivalent cat No. in Seimens/Schneider/ GE
S&F MCB SP 6- 32 Amps 240 Volts, 10 KA (C Curve) complete all as specified and directed. Make: Legrand cat No 4085 87-95 or equivalent cat No. in Seimens/ Schneider/ GE
S&F Isolator DP 63 Amps Breaking capacity 10 KA (C Curve) complete all as specified and directed. Make: Legrand cat No 4065 02or equivalent cat No. in Seimens/Schneider/ GE
NOEL ENGINEERS
ORIENT ELECTRIC CO
ASHOK ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .