Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC PO PS BOMDILA DISTT WEST KAMENG ARUNACHAL PRADESH 790001 | BOMDILA | WEST KAMENG | ARUNACHAL PRADESH | 790001 | L1 | Accepted-AOC DUE TO L1 BIDDER | |
| 2 | L2₹52.2 L+₹1.7 L (3.43%)Rejected-Finance | L2 | Rejected-Finance REJECTED DUE TO L2 BIDDER | |
| 3 | L3₹54.8 L+₹4.3 L (8.58%)Rejected-Finance | L3 | Rejected-Finance REJECTED DUE TO L3 BIDDER | |
| 4 | L4₹55.7 L+₹5.2 L (10.4%)Rejected-Finance | L4 | Rejected-Finance REJECTED DUE TO L4 BIDDER | |
| 5 | L5₹56.5 L+₹6.0 L (12.0%)Rejected-Finance | L5 | Rejected-Finance REJECTED DUE TO L5 BIDDER |
| Sl No | Description | Qty | Unit | M/s Paramount Association of India L1 | M/S DK TRADERS L5 | M/S R P M CONSTRUCTION L8 | M/S R.N ENTERPRISE L7 | M/s 99 Enterprise of India L2 | M/S MURPHEW ENTERPRISES L6 | M/S HIGHLANDERS ASSOCIATE OF HIMALAYAS L3 | M/S ASHOK CONSTRUCTION L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminium bus bar four Nos 400 Amps each fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos
Incoming:-
(b) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%) | 1 | Each Job | 2,12,000 ₹2,12,000 Lowest | 2,50,000 ₹2,50,000 | 2,29,000 ₹2,29,000 | 2,40,000 ₹2,40,000 | 2,15,000 ₹2,15,000 | 2,48,000 ₹2,48,000 | 2,30,000 ₹2,30,000 | 2,35,000 ₹2,35,000 |
| 1.01Outgoing:- (c) MCCB, 04 Pole, 63 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 02 Nos (Ics=Icu=100%) (d) MCCB, 04 Pole, 32 Amps with ultimate breaking capacity Icu- 25 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 06 Nos (Ics=Icu=100%) (e) Spare way for MCCB 63 Amp 4 pole - 01 Nos, (f) Digital type volt meter 0-300 volt with selector switch with HRC fuses/ MCBs - 1 set. (g) Digital type ammeter meter 400 Amp with selector switch with HRC fuses/ MCBs - 1 set. (h) LED phase indication lamps R,Y,B LED type with 3 Nos of 2A HRC Fuses – 1 set:- (i) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's/SDFU. (j) Platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 mm thick in foundation, brick work in CM 1:6 with sub class B old sized bricks, renderung 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. Note :- Panel drawings & make of MCCB will be submitted by contractor for approval from Accepting Officer before ordering the panel | |||||||||||
| 2.00 | Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000V grade with stranded aluminium conductor of size 95 sqmm 3 core including taking down of old unserviceable UG cable/service wires. | 865 | RM | 930 ₹8,04,450 Lowest | 1,250 ₹10,81,250 | 1,235 ₹10,68,275 | 1,260 ₹10,89,900 | 1,000 ₹8,65,000 | 1,250 ₹10,81,250 | 1,200 ₹10,38,000 | 1,240 ₹10,72,600 |
| 3.00 | Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 120 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires. | 120 | RM | 750 ₹90,000 Lowest | 910 ₹1,09,200 | 910 ₹1,09,200 | 925 ₹1,11,000 | 800 ₹96,000 | 910 ₹1,09,200 | 900 ₹1,08,000 | 900 ₹1,08,000 |
| 4.00 | Description all as per item No 03 above but of size 70 Sqmm 3.5 core | 200 | RM | 500 ₹1,00,000 Lowest | 620 ₹1,24,000 | 598 ₹1,19,600 | 610 ₹1,22,000 | 550 ₹1,10,000 | 620 ₹1,24,000 | 600 ₹1,20,000 | 600 ₹1,20,000 |
| 5.00 | Description all as per item No 03 above but of size 35 Sqmm 3.5 core | 200 | RM | 330 ₹66,000 Lowest | 440 ₹88,000 | 419 ₹83,800 | 450 ₹90,000 | 330 ₹66,000 Lowest | 435 ₹87,000 | 400 ₹80,000 | 420 ₹84,000 |
| 6.00 | Description all as per item No 03 above but of size 35 Sqmm 3.5 core | 215 | RM | 500 ₹1,07,500 Lowest | 510 ₹1,09,650 | 505 ₹1,08,575 | 520 ₹1,11,800 | 500 ₹1,07,500 Lowest | 500 ₹1,07,500 Lowest | 500 ₹1,07,500 Lowest | 510 ₹1,09,650 |
| 7.00 | Description all as per item No 03 above but of size 25 Sqmm 4 core | 280 | RM | 530 ₹1,48,400 Lowest | 550 ₹1,54,000 | 550 ₹1,54,000 | 550 ₹1,54,000 | 530 ₹1,48,400 Lowest | 560 ₹1,56,800 | 530 ₹1,48,400 Lowest | 550 ₹1,54,000 |
| 8.00 | Description all as per item No 03 above but of size 16 Sqmm 4 core | 460 | RM | 350 ₹1,61,000 Lowest | 505 ₹2,32,300 | 510 ₹2,34,600 | 510 ₹2,34,600 | 400 ₹1,84,000 | 515 ₹2,36,900 | 500 ₹2,30,000 | 510 ₹2,34,600 |
| 9.00 | Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out soft & loose soil complete all as specified and as directed. | 465 | Cum | 630 ₹2,92,950 | 625 ₹2,90,625 Lowest | 635 ₹2,95,275 | 640 ₹2,97,600 | 630 ₹2,92,950 | 650 ₹3,02,250 | 630 ₹2,92,950 | 630 ₹2,92,950 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
15 Nov 2025, 9:00 amClosed
GE TENGA
GE TENGA PIN-790116 C/O 99 APO
RENEWAL/REPLACEMENT OF ALUMINIUM WIRING AT BLDG NO FWH-01 AND OLD VINTAGE WIRING AT SINGLE OFFICERS ACCN (BLDG NO T/OPT/92 AND TW/309 LP-21) AND SPECIAL REPAIR/REPLACMENT OF OLD UG CABLES AND CONNECTED ITEMS WORK OF E/M UNDER GE TENGA
2025_MES_736778_1
8068/E8
Open Tender
Civil Works
Item Rate
180 days
GE TENGA
PLS REF NIT
7 documents required · 7 mandatory
₹500
GE TENGA
₹98,000
Yes
22 Dec 2025
25 Oct 2025
17 Nov 2025
25 Oct 2025
15 Nov 2025
8 Nov 2025
Amount
Supply, installing, testing and commissioning, factory made and tested ,CPRI type tested LT feeder pillar, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and LT panel shall bemounted on angular frame work of 50x50x5mm thick angle iron base frame, minimum 60 cm hight and fixed with PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) in foundation for fixing panels, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door shutter and locking arrangement and consisting of the following all as specified including taking out old feeder pillar and taking out LT cable from loop for connecting in new panel and necessary excavation etc and consisting of the following:- (a) Aluminium bus bar four Nos 400 Amps each fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 04 Nos Incoming:- (b) MCCB, 04 Pole, 160 Amps with ultimate breaking capacity Icu- 36 KA at 415 volts, adjustable type with thermal and magnetic settings conforming to IEC 60947 Part-I/IS-13947 Part-I - 01 No (Ics=Icu=100%)
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 11000V grade with stranded aluminium conductor of size 95 sqmm 3 core including taking down of old unserviceable UG cable/service wires.
Supply, laying & testing in repalcement cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminum conductor, 1100V grade with stranded aluminium conductor of size 120 sqmm 3.5 core including taking down of old unserviceable UG cable/service wires.
Description all as per item No 03 above but of size 70 Sqmm 3.5 core
Description all as per item No 03 above but of size 35 Sqmm 3.5 core
Description all as per item No 03 above but of size 35 Sqmm 3.5 core
Description all as per item No 03 above but of size 25 Sqmm 4 core
Description all as per item No 03 above but of size 16 Sqmm 4 core
Excavation in trenches in any type of soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out soft & loose soil complete all as specified and as directed.
Returning fitting in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
M & L for laying of fine, clean sand (river sand) free from sharp materials and stone particals in trenches for cushioning of cable 8 cm thick under cable and 15 cm thick over the cable including gently punning complete all as specified and directed. Note:- The total thickness of sand shall be measured 18 cm after punning.
Supply and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 300mm x 180mm x 40mm, factory made of specified make , complete all as specified and directed.
Supply and laying un-reinforced precast.concrete cable protection cover of class LV, type-1, flat size 250mm x 150mm x 40 mm, factory made of specified make , complete all as specified and directed.
Supply and laying galvanised tube light grade ISI marked of size 40 mm dia incl all fittings in trenches/fixed on pole/wall/floor or laid in position complete all as specified and directed.
M & L for road cutting incl necessary excavation 45 cm wide and 90 cm in depth as in trenches in any type of soils/rock for laying LT UG cable through pipe after laying /through the cable trenches will be filling top with M&L PCC 1:3:6 type C-1 using 20 mm grdaeds stone aggregates from top over 15 cm thick hard good of broken boulders , 63 mm gauge over 15 cm bolders 100 mm dia over filled and rammed earth to make good the disburbed surface etc complete all as specified and directed.
Supply and laying Double wall corrugated HDPE duct pipe 80mm outer dia confirming to IS: 14930 (Part-II) of approved colour with fittings for cable protection complete laid in trenches or fixed on walls with clamps of suitable size all as specified and directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron strip 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, RCC pit cover , charcol, salt including provision of earth lead protected by 32 mm dia light grade GI pipe and 20 mm dia medium grade GI Pipe for watering complete.
S&F concealed in wall MCB DB double door TPN 4 way sheet phospetised powder painted with 200 Amps rated bus bar 415 Volts neutral link, IP 43 protection double door fixing on wall/woood surface making good surface complete all as spcified and as directed
M&L for repairing of existing panel and panel Doors, Hinges ,Legs including welding denting painting reveting hinges lockings arrangment etc requirment etc required at site all as specified and directed by Engr In Charge. Note :- Dissecting/Connecting of all Incomming and Out going Conections before Painting and waeling works of exiting Panels deems to be quotated rate.
Material & Labour for Point/fan wiring with 1.5 sq mm (nominal area), PVC insulated unsheathed (FRLSH), 1100 volts grade, multi-stranded copper conductor, in and including PVC casing capping of adequate size with all fittings and accessories including PVC boxes for housing the switches ( Make of box Prestoplast, Prestoteak), including PVC insulated and unsheathed (FRLSH) single core multi-stranded copper conductor cable of size 1.5 sq mm green in colour as earth continuity conductor connected to common earth dolly complete all as specified and directed.
All as per item No. 21 here in before One bell/buzzer point controlled by one bell push complete all as specified and as directed .
All as per item No. 21 here in before One 3 pin socket outlet, 6 Amps on the same board with other switches, with cables 1.5sq. mm size
All as per item No. 21 here in before but for one 3 pin socket outlet 6 Amps three pin controlled by one switch on independent board complete all as specified directed.
All as per item No. 21 here in before but for one 5 pin socket outlet 16 Amp and 6 Amp Multipurpose independent using 2.5 Sqmm copper conductor cable (multi-strand) PVC insulated and unsheathed cable and 2.5 sqmm copper (multistrand) PVC insulated and unsheathed earth wire with PVC boxes complete all as specified.
S&F bell/buzzer push 5/6 Amp,flush type complete all as specified & as directed.
S&F call bell ding dong electric AC, 240 volt, 50 HZ, surface type complete all as specified & as directed.
S&F Socket outlet 2 in 1, 3 pin, 6 amp flush type
S&F Socket outlet 2 in 1, 3 pin, 6 and 16 amp flush type
Supply & fixing switch piano flush type (ISI marked), single pole, one way 16 Amp, 240 Volts complete all as specified & directed.
Supply and fixing ceiling rose, surface bakelite, 65mm x 50mm , two to three terminals complete all as specified & directed.
Supply & fixing switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified & directed.
Supply and fixing lamp holder, insuleted body with pack plate suitable batten fitting on wall duly grouted/fixed in solid block wall or on wooden board complete all as specified and directed.
S&F LED lamp 9 Watt, CDL, B-22 cap, (Pin type), 230W, PF not less tha 0.85 (min). Make- Havells/Crompton/Syska
Supply and fixing LED light fitting 1 x 20 Watt 220 volt AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, (warm/white), 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete
Supply and fixing round/square shape 15 watt 220 volts AC (Warm/white) recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
S&F of new generation energy saving and environmental friendly long life LED building security light made up of innovative die cast aluminium housing high power LED as lighting source with IP - 66 power consumption 35 watt complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) complete including twisted 3 core copper cable of size 1.5 Sqmm dia for connecting phase, neutral and earth from ceiling rose to light length as required at site,GI bracket 32 mm dia pipe and 02 numbers of clamps, all fixing arrangements such as fastners, bolts, nuts washers etc all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm
Supply, fix and testing refrigerator, electric driven (single phase), capacity 315 Liters BEE 5 star rated,double door, frost free, all as specified and directed.
Supply, fix and testing refrigerator, electric driven (single phase), capacity 200 Liters BEE 5 star rated,double door, frost free, all as specified and directed.
Supply and fix sheet metal enclosures for double door DBs when MCBs to be used 230 volts 12 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
Supply and fix sheet metal enclosures for DBs when MCBs to be used 230 volts 8 way 200 Amp rated busbar single pole and neutral fixed on wall duly grouted in solid block wall or on wooden board.
S&F MCB SPN having braking capacity 10KA, 32 Amps, 240 V complete all as specified and directed.
S&F MCB SP having braking capacity 10KA, 6 to 32 Amps, 240 V complete all as specified and directed.
S&F in replacement MCCB 4 pole 415 Volts, 50 Hz, 36 KA of capacity 200 Amps complete all as specified and as directed
S&F in replacement MCCB 4 pole 415 Volts, 50 Hz, 16 KA of capacity 125 Amps complete all as specified and as directed
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15 mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm C/C with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge.
S&F in replacement of 1100 Volts grade heavy duty ISI marked cable PVC insulated multi stranded aluminium conductor one twin core cable flat or circular of size 16 sqmm served with inner sheathing of PVC tape & overall PVC sheathed in service connections , of size 16 Smm 2 core. Make :- Havells/ Plaza cables/ polycab /Finolex
Supply, fixing, testing and commissioning split type air conditioner, single phase AC 230 Volt, 2 TR capacity with a minimum 5 star (BEE) rating (Latest model) including necessary initial gas charging as required, fixing arrangement for blower unit and PCC (1:2:4) mounting platform of required dimensions for outdoor compressor unit, copper tubing of suitable size with insulation to the required length, PVC pipe 15 mm dia, fixed to wall surface for condensed water outlet with cooling and heating function . Make : CARRIER/HITACHI/LLOYD/BLUESTAR
Supply, fixing, testing and commissioning split type air conditioner, single phase AC 230 Volt, 1.5 TR capacity with a minimum 5 star (BEE) rating (Latest model) including necessary initial gas charging as required, fixing arrangement for blower unit and PCC (1:2:4) mounting platform of required dimensions for outdoor compressor unit, copper tubing of suitable size with insulation to the required length, PVC pipe 15 mm dia, fixed to wall surface for condensed water outlet with cooling and heating function . Make : CARRIER/HITACHI/LLOYD/BLUESTAR
Supply & fix Voltage stabilizer for automatic operation single phase naturally air cooled indoor type & designed for input variation between170 V - 280 V output voltage stabilized at 230 V with accuracy of ± 2.5 of capacity 5 KVA all as directed by Engineer-in-Charge
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 kVA
S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed FRLSH cable with multistranded copper conductor 10 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 10 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 10 sqmm earth wire and 2 Run of 10 sqmm cable shall be measured as one run.)
S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed FRLSH cable with multistranded copper conductor 6 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 6 sqmm earth wire and 2 Run of 6 sqmm cable shall be measured as one run.)
S&F wire for circuit/sub main wiring with 1100 volts grade double core PVC insulated and unsheathed FRLSH cable with multistranded copper conductor 4 Sqmm, on surface or recessed or drawn in PVC casing capping/PVC Pipe along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.(Note: One RM PVC casing capping/PVC conduit ,one run of 4 sqmm earth wire and 2 Run of 4 sqmm cable shall be measured as one run.)
Supply and fixing, metal clad socket out let with MCB single pole 20 Amp, 240 V including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified.
Supply and fix electric water heater(Geyser), storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre, BEE 5 star rated adjustable temprature setting 0-90 degree C complete with accessories such as safety wall, thermostate, NRV indication lamps, inlet outlet connections,air vent connections, connection pieces including all fixing arrangements such as fastners, bilts, nuts washers etc including making good disturbed wall surfaces matching with the existing surface and finishing complete all as specified and directed by Engr in charge
S & F incl leakage testing galvanised steel water tubing medium grade 15 mm dia bore with all fittings such as bends, elbow, socket, reducer etc, laid under floor / trenches all as specified & directed.
S&F Stop valves, cast copper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe of size 15 mm.
S&F Bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed all as specified & as directed by engr-in-charge.
M & L for PVC connections 15mm size with PTMT nuts of length 450mm for hot and cold water connection complete
Taking down point wiring carefully copper/ aluminum (light,fan, socket or power) complete (fittings such as switches ceiling rose, pendents, regulators, sockets etc)
Taking down main switches, DBs alongwith existing board and removing the same from the site and making good the disturb surfaces / Portion of the wall etc all specified and directed by EIC.
Taking down sub main wiring of any type and size and discription incl removal from DBs etc and removal of the same from site and making good the disturb surfaces or portion of wall/ceiling etc complete all as specified and directed by EIC.
M/s 99 Enterprise of India (BID ID -3470457)
M/S HIGHLANDERS ASSOCIATE OF HIMALAYAS (BID ID -3470461)
M/S ASHOK CONSTRUCTION (BID ID -3471459)
M/S DK TRADERS (BID ID -3471823)
M/S MURPHEW ENTERPRISES (BID ID -3473205)
M/S R.N ENTERPRISE (BID ID -3472591)
M/S R P M CONSTRUCTION (BID ID -3472515)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.86 MB
Tender.pdf
Tender Documents • 6.37 MB
BOQ_824966.xls
BOQ • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .