Tender Value
₹81.6 Cr
EMD Value
₹1.6 Cr
Closing Date
28 Jul 2026, 3:00 pmClosed
Yes (up to 3 members)
No
Two Packet System
Normal Tender
Yes
25/06/2026 12:00
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
14 conditions · 3 needing a document upload
10.2. Financial Eligibility Criteria:The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
10.1 Technical Eligibility Criteria: The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender.
"Execution of traction substation of 110KV or higher voltage level or Execution of HT Substation/HT switchyard of 110KV or higher voltage level.", as under :The work must have been carried out in any of the following organization :- a) Central Government department or State Government department b) Central Government PSUs or State Government PSUs.
12 conditions · 6 needing a document upload
Annexure-VIB along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet - The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Documents for evaluating the Bid Capacity for tenders having advertised value more than Rs. 20.00 Crore (Ref: Clause 10.3 and for tenderer participating as JV firm Clause 17.15.3 of TENDER FORM (Second Sheet) along with Annexure-VI at Page Nos. 14, 25 & 35-36 of GCC APRIL 2022)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Special condition of contract for mandatory updation of labour data on Railways Shramikkalyan Portal by contractor in term of clause 54 and 55 of GCC July 2020. Railway Bd.lr. No.2018/CE- I/CT/4, dated 17.10.2018.
Design, manufacture, supply of associated equipments, erection, testing & commissioning of 1 No. 132kV/55kV (2x25kV System) Scott Connected transformer TSS , Bay modification work at Pachora TSS, along with 2 No. of Sectioning & Paralleling Post (SP) and 4 No. of Sub-sectioning & Paralleling Post (SSP) In Connection With Gauge Conversion Work From Pachora-Jamner in Bhusawal division of Central Railway.
BSL-LC-TENDER-11-2026
BSL-LC-TENDER-11-2026
Open
Works - General
12 Months
Jalgaon, Maharashtra
₹0
₹1.6 Cr
11 Jun 2026
11 Jun 2026
14 Jul 2026
25 Jun 2026
406 items across 5 schedules · ₹81,60,31,908.26 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | (1) Design & drawing of traction sub station | Each | 1.00 | 2,40,177 | 2,40,177 |
| 2 | (2) Design & drawing of feeding post(Pahur FP & Pachora FP) . | Each | 2.00 | 63,918 | 1,27,836 |
| 3 | 3(a) Supply of 25 KV DO fuse switch assembly. | Numbers | 2.00 | 11,791 | 23,582 |
| 4 | 3(b) Erection of 25 KV DO fuse switch assembly. | Numbers | 2.00 | 853 | 1,706 |
| 5 | 4(a) Supply of 132kV termination with disc insulator & adjustor. | Numbers | 30.00 | 19,826 | 5,94,780 |
| 6 | 4(b) Erection of 132kV termination with disc insulator & adjustor. | Numbers | 30.00 | 636 | 19,080 |
| 7 | 5(a) Supply of 132 kV termination with disc insulator & without adjustor. | Numbers | 30.00 | 18,779 | 5,63,370 |
| 8 | 5(b) Erection of 132 kV termination with disc insulator & without adjustor. | Numbers | 30.00 | 636 | 19,080 |
| 9 | 6(a) Supply of 50 kV termination without adjuster complete with disc insulators. | Each | 4.00 | 13,683 | 54,732 |
| 10 | 6(b) Erection of 50 kV termination without adjuster complete with disc insulators. | Each | 4.00 | 554 | 2,216 |
| 11 | 7(a) Supply without insulator of materials for termination of copper cross feeder with gantries. | Numbers | 8.00 | 7,096 | 56,768 |
| 12 | 7(b) Erection of materials for termination of copper cross feeder with gantries. | Numbers | 8.00 | 1,477 | 11,816 |
| 13 | 8(a) Supply of 250 AH, 110 V low maintenance lead acid (LMLA) batteries set with 2 nos. of suitable battery charger (1 set = 1 battery set & 2 nos. battery charger). battery charger. Battery make - EXIDE | Set | 2.00 | 6,36,401 | 12,72,802 |
| 14 | 8(b) Installation of 250 AH, 110 V low maintenance lead acid (LMLA) batteries set with 2 nos. of suitable battery charger (1 set = 1 battery set & 2 nos. battery charger). battery charger. Battery make - EXIDE | Set | 2.00 | 18,871 | 37,742 |
| 15 | (9) Transportation & Erection of 13 Mtrs. (52/60KG) release long Rails from nominated place with in 10 KM area to works site. | Set | 4.00 | 8,495 | 33,980 |
| 16 | 10(a) Supply of 132 KV/2x55KV, 60/84/100MVA, ONAN/ONAF, three phase scott connection Traction Power Transformer | Numbers | 2.00 | 11,49,02,317 | 22,98,04,634 |
| 17 | 10(b) Erection of 132 KV/2x55KV, 60/84/100MVA, ONAN/ONAF, three phase scott connection Traction Power Transformer | Numbers | 2.00 | 12,57,951 | 25,15,902 |
| 18 | 11(a) Concrete for foundation and trench in hard soil.:-Supply | cum | 88.04 | 4,688 | 4,12,731.52 |
| 19 | 11(b) Concrete for foundation and trench in hard soil.:-Erection | cum | 88.04 | 2,764 | 2,43,342.56 |
| 20 | 12(a) Concrete for foundation and trench in rock.:-Supply | cum | 88.04 | 4,833 | 4,25,497.32 |
| 21 | 12(b) Concrete for foundation and trench in rock.:-Erection | cum | 88.04 | 3,539 | 3,11,573.56 |
| 22 | 13(a) Concrete for foundation other than hard soil and rock.:-Supply | cum | 704.35 | 4,698 | 33,09,036.3 |
| 23 | 13(b) Concrete for foundation other than hard soil and rock.:-Erection | cum | 704.35 | 2,038 | 14,35,465.3 |
| 24 | 14(a) Reinforced concrete for foundation & trench:-Supply | cum | 80.69 | 5,481 | 4,42,261.89 |
| 25 | 14(b) Reinforced concrete for foundation & trench:-Erection | cum | 80.69 | 2,492 | 2,01,079.48 |
| 26 | 15(a) Reinforced concrete for cable trench covers.:-Supply | Sqm | 215.75 | 1,845 | 3,98,058.75 |
| 27 | 15(b) Reinforced concrete for cable trench covers.:-Erection | Sqm | 215.75 | 839 | 1,81,014.25 |
| 28 | 16(a) Reinforced brick work for baffle wall:-Supply | cum | 38.40 | 5,318 | 2,04,211.2 |
| 29 | 16(b) Reinforced brick work for baffle wall:-Erection | cum | 38.40 | 1,729 | 66,393.6 |
| 30 | 17(a) Plastering of brick work.:-Supply | Sqm | 213.50 | 87 | 18,574.5 |
| 31 | 17(b) Plastering of brick work.:-Erection | Sqm | 213.50 | 83 | 17,720.5 |
| 32 | 18(a) Supply of gravel / ballast in the switch area | cum | 546.45 | 1,617 | 8,83,609.65 |
| 33 | 18(b) Spreading of gravel / ballast in the switch area | cum | 546.45 | 17 | 9,289.65 |
| 34 | (19) Insulator for cross feeder | Set | 16.00 | 3,619 | 57,904 |
| 35 | 20(a) Supply 25kV Support/post Insulator | Numbers | 26.00 | 7,776 | 2,02,176 |
| 36 | 20(b) Erection 25kV Support/post Insulator | Numbers | 26.00 | 340 | 8,840 |
| 37 | 21(a) Supply 50/55 KV Support Insulator. | Numbers | 4.00 | 14,163 | 56,652 |
| 38 | 21(b) Erection 50/55 KV Support Insulator. | Numbers | 4.00 | 1,306 | 5,224 |
| 39 | 22(a) Supply of 132 Kv Support insulator | Numbers | 6.00 | 26,763 | 1,60,578 |
| 40 | 22(b) Erection of 132 Kv Support insulator | Numbers | 6.00 | 1,306 | 7,836 |
| 41 | 23(a) Supply of galvanization steel structure including Traction mast, main masts, fabricated steel other than mast , SPS , Tower gantries ,portal, suppoting structures & small part steel work. | MT | 125.63 | 1,35,237 | 1,69,89,824.31 |
| 42 | 23(b) Erection of galvanization steel structure including Traction mast, main masts, fabricated steel other than mast , SPS , Tower gantries ,portal, suppoting structures & small part steel work. | MT | 125.63 | 6,201 | 7,79,031.63 |
| 43 | 24(a) Supply of earth electrode | Numbers | 74.00 | 3,661 | 2,70,914 |
| 44 | 24(b) Erection of earth electrode | Numbers | 74.00 | 2,472 | 1,82,928 |
| 45 | 25(a) Supply of earth bus 75x8 mm. MS strip laid in the ground. | Metre | 442.00 | 341 | 1,50,722 |
| 46 | 25(b) Erection of earth bus 75x8 mm. MS strip laid in the ground. | Metre | 442.00 | 141 | 62,322 |
| 47 | 26(a) Supply of earth bus 75x8 mm. MS strip laid exposed. | Metre | 1224.00 | 341 | 4,17,384 |
| 48 | 26(b) Erection of earth bus 75x8 mm. MS strip laid exposed. | Metre | 1224.00 | 101 | 1,23,624 |
| 49 | 27(a) Supply of 8/6 SWG GI wire for earthing | Metre | 130.00 | 35 | 4,550 |
| 50 | 27(b) Erection of 8/6 SWG GI wire for earthing | Metre | 130.00 | 32 | 4,160 |
| 51 | 28(a) Supply of 32 mm dia earth rod for earth mat | Metre | 2272.75 | 525 | 11,93,193.75 |
| 52 | 28(b) Erection of 32 mm dia earth rod for earth mat | Metre | 2272.75 | 41 | 93,182.75 |
| 53 | 29(a) Supply of earth screen wire of size 19/2.5mm. | Metre | 780.00 | 372 | 2,90,160 |
| 54 | 29(b) Erection and termination of earth screen wire of size 19/2.5mm. | Metre | 780.00 | 30 | 23,400 |
| 55 | 30(a) Supply fencing panel at substation for TSS. | Metre | 329.50 | 2,561 | 8,43,849.5 |
| 56 | 30(b) Erection fencing panel at substation for TSS | Metre | 329.50 | 134 | 44,153 |
| 57 | 31(a) Supply of fencing up right. | MT | 3.95 | 91,778 | 3,62,523.1 |
| 58 | 31(b) Erection of fencing up right. | MT | 3.95 | 5,996 | 23,684.2 |
| 59 | 32(a) Supply of gates | Metre | 16.50 | 2,432 | 40,128 |
| 60 | 32(b) Erection of gates | Metre | 16.50 | 413 | 6,814.5 |
| 61 | 33(a) Supply of anti climbing device at substation. | Metre | 329.50 | 257 | 84,681.5 |
| 62 | 33(b) Erection of anti climbing device at substation. | Metre | 329.50 | 13 | 4,283.5 |
| 63 | 34(a) Supply of heavy duty ISI marked 'B' class GI pipe of 3.65mm wall thickness and 50mm dia to be laid along the wall or floor with proper galvanized clamps/ through the wall or undernaeth the floor in cement concrete as per explanatory note. | Metre | 24.00 | 181 | 4,344 |
| 64 | 34(b) Laying and fixing of heavy duty ISI marked 'B' class GI pipe of 3.65mm wall thickness and 50mm dia to be laid along the wall or floor with proper galvanized clamps/ through the wall or undernaeth the floor in cement concrete as per explanatory note. | Metre | 24.00 | 20 | 480 |
| 65 | 35(a) Supply (without Insulator) of 25 kV, 2000 Amp. Double Pole Isolator without Earthing Blade Assembly (Manually Operated) | Numbers | 18.00 | 1,02,478 | 18,44,604 |
| 66 | 35(b) Erection of 25 kV, 2000 Amp. Double Pole Isolator without Earthing Blade Assembly (Manually Operated) | Numbers | 18.00 | 5,401 | 97,218 |
| 67 | 36(a) Supply (without Insulator) of 25 kV, 2000 Amp. Double Pole Isolator without Earthing Blade Assembly (Motorized). | Numbers | 1.00 | 1,67,906 | 1,67,906 |
| 68 | 36(b) Erection of 25 kV, 2000 Amp. Double Pole Isolator without Earthing Blade Assembly (Motorized). | Numbers | 1.00 | 5,401 | 5,401 |
| 69 | 37(a) Supply of 50/55 kV Double pole isolator(With insulator). | Numbers | 4.00 | 1,48,786 | 5,95,144 |
| 70 | 37(b) Erection of 50/55 kV Double pole isolator(With insulator). | Numbers | 4.00 | 6,512 | 26,048 |
| 71 | 38(a) Supply of 132 KV Triple pole Isolator without earthing heel (Manually operated assembly with insulator). | Numbers | 3.00 | 1,81,908 | 5,45,724 |
| 72 | 38(b) Erection of 132 KV Triple pole Isolator without earthing heel (Manually operated assembly with insulator). | Numbers | 3.00 | 9,768 | 29,304 |
| 73 | 39(a) Supply of 132 KV Triple pole Isolator with earthing heel (Manually operated assembly with insulator). | Numbers | 2.00 | 2,38,551 | 4,77,102 |
| 74 | 39(b) Erection of 132 KV Triple pole Isolator with earthing heel (Manually operated assembly with insulator). | Numbers | 2.00 | 11,872 | 23,744 |
| 75 | 40(a) Extra for Supply of earthing blade assembly for 132 KV Triple pole 1250Amp isolator. | Numbers | 2.00 | 43,056 | 86,112 |
| 76 | 40(b) Extra for Erection of earthing blade assembly for 132 KV Triple pole 1250Amp isolator. | Numbers | 2.00 | 1,402 | 2,804 |
| 77 | 41(a) Supply o f 50 kV Berismis AAAC Conductor of size 36 mm dia(768 sqmm). | Metre | 334.00 | 902 | 3,01,268 |
| 78 | 41(b) Erection o f 50 kV Berismis AAAC Conductor of size 36 mm dia(768 sqmm). | Metre | 334.00 | 55 | 18,370 |
| 79 | 42(a) Supply of 132 kV/66kV/25kVconnectors, bus splices & TEE Connectors etc. required for commissioning of TSS as per explanatory note. | Each | 496.00 | 3,664 | 18,17,344 |
| 80 | 42(b) Erection of 132 kV/66kV/25kVconnectors, bus splices & TEE Connectors etc. required for commissioning of TSS as per explanatory note. | Each | 496.00 | 63 | 31,248 |
| 81 | 43(a) Supply of Aluminium jumper | Each | 140.00 | 3,008 | 4,21,120 |
| 82 | 43(b) Erection of Aluminium jumper | Each | 140.00 | 402 | 56,280 |
| 83 | 44(a) Supply of 50/39mm tubular aluminium busbar. | Metre | 650.00 | 1,153 | 7,49,450 |
| 84 | 44(b) Erection of 50/39mm tubular aluminium busbar. | Metre | 650.00 | 107 | 69,550 |
| 85 | 45(a) Supply of ACSR Zebra Conductor of size 28.62 mm dia. | Metre | 309.00 | 724 | 2,23,716 |
| 86 | 45(b) Erection of ACSR Zebra Conductor of size 28.62 mm dia. | Metre | 309.00 | 154 | 47,586 |
| 87 | 46(a) Supply of copper strip for equipment earthing. | Metre | 130.40 | 1,050 | 1,36,920 |
| 88 | 46(b) Erection of copper strip for equipment earthing. | Metre | 130.40 | 124 | 16,169.6 |
| 89 | 47(a) Supply of copper cross feeder wires (37/2.25 mm HDBC) across the track at SP/SSP/FP/BT locations | Kilometre | 0.12 | 20,28,872 | 2,43,464.64 |
| 90 | 47(b) Erection of copper cross feeder wires (37/2.25 mm HDBC) across the track at SP/SSP/FP/BT locations | Kilometre | 0.12 | 5,082 | 609.84 |
| 91 | 48(a) Supply of large copper jumper 160 sqmm cross feeder/isolator and OHE. | Numbers | 12.00 | 16,054 | 1,92,648 |
| 92 | 48(b) Erection of large copper jumper 160 sqmm cross feeder/isolator and OHE. | Numbers | 12.00 | 602 | 7,224 |
| 93 | 49(a) Supply of 12.3 MVA , 55 KV/27.5 KV , 50HZ Auto Transformer with bushing andoil and other equipments as per RDSOspec. suitable for 2 x25KV AT feedingsystem. | Numbers | 4.00 | 1,21,51,347 | 4,86,05,388 |
| 94 | 49(b) Erection of 12.3 MVA , 55 KV/27.5 KV , 50HZ Auto Transformer with bushing andoil and other equipments as per RDSOspec. suitable for 2 x25KV AT feedingsystem. | Numbers | 4.00 | 4,43,070 | 17,72,280 |
| 95 | 50(a) Supply of control & relay panel incoporating Numerical type protective relays for TSS suitable for Scott connected Power Transformer | Numbers | 1.00 | 2,06,98,798 | 2,06,98,798 |
| 96 | 50(b) Erection of control & relay panel incoporating Numerical type protective relays for TSS suitable for Scott connected Power Transformer | Numbers | 1.00 | 27,483 | 27,483 |
| 97 | 51(a) Supply of 25 KV Double pole, vaccum type circuit breaker(2000A) with interlocking . | Numbers | 8.00 | 9,99,683 | 79,97,464 |
| 98 | 51(b) Erection, testing and commissioning of 25 KV Double pole, vaccum type circuit breaker(2000A) with interlocking . | Numbers | 8.00 | 13,868 | 1,10,944 |
| 99 | 52(a) Supply of 25 KV vacuum double pole type interruptor | Numbers | 3.00 | 9,96,323 | 29,88,969 |
| 100 | 52(b) Erection, testing and commissioning of 25 KV vacuum double pole type interruptor | Numbers | 3.00 | 8,996 | 26,988 |
| 101 | 53(a) Supply of 132 KV Triple pole SF-6 Circuit breaker with interlock. | Numbers | 2.00 | 16,01,330 | 32,02,660 |
| 102 | 53(b) Erection of 132 KV Triple pole SF-6 Circuit breaker with interlock. | Numbers | 2.00 | 22,883 | 45,766 |
| 103 | 54(a) Supply of 50/66kV Double Pole SF- 6Circuit Breaker | Numbers | 4.00 | 5,56,615 | 22,26,460 |
| 104 | 54(b) Erection of 50/66kV Double Pole SF- 6Circuit Breaker | Numbers | 4.00 | 15,255 | 61,020 |
| 105 | 55(a) Supply of 25 KV current transformer(1500-750/5A) | Each | 8.00 | 1,10,715 | 8,85,720 |
| 106 | 55(b) Erection, testing and commissioning of 25 KV current transformer(1500- 750/5A) | Each | 8.00 | 2,251 | 18,008 |
| 107 | 56(a) 50 KV CT(1500-750/5A) :-Supply | Numbers | 8.00 | 1,24,119 | 9,92,952 |
| 108 | 56(b) 50 KV CT(1500-750/5A) :-Erection | Numbers | 8.00 | 3,415 | 27,320 |
| 109 | 57(a) Supply of 132 KV current transformer. | Numbers | 6.00 | 3,71,879 | 22,31,274 |
| 110 | 57(b) Erection 132 KV current transformer. | Numbers | 6.00 | 3,546 | 21,276 |
| 111 | 58(a) Supply of 25 KV potential transformer (PT)Type-I | Numbers | 6.00 | 85,932 | 5,15,592 |
| 112 | 58(b) Erection, testing and commissioning of 25 KV potential transformer (PT)Type-I | Numbers | 6.00 | 1,100 | 6,600 |
| 113 | 59(a) 27.5 kV /110 V potential transformer (type-II)(52 kV insulation class):-Supply | Numbers | 4.00 | 85,932 | 3,43,728 |
| 114 | 59(b) 27.5 kV /110 V potential transformer (type-II)(52 kV insulation class):-Erection | Numbers | 4.00 | 1,100 | 4,400 |
| 115 | 60(a) Supply 132 KV potential transformer. | Numbers | 6.00 | 2,13,643 | 12,81,858 |
| 116 | 60(b) Erection 132 KV potential transformer. | Numbers | 6.00 | 3,546 | 21,276 |
| 117 | 61(a) Supply of Lightning Arrestors 42 KV rating for 25 KV side. | Numbers | 6.00 | 44,248 | 2,65,488 |
| 118 | 61(b) Erection of Lightning Arrestors 42 KV rating for 25 KV side. | Numbers | 6.00 | 1,021 | 6,126 |
| 119 | 62(a) Supply of 60kV Lightening arrester with accessories. | Numbers | 8.00 | 1,06,572 | 8,52,576 |
| 120 | 62(b) Erection of 60kV Lightening arrester with accessories. | Numbers | 8.00 | 2,579 | 20,632 |
| 121 | 63(a) Supply of 132 KV lightening arrester(110kvLA) | Numbers | 12.00 | 1,89,276 | 22,71,312 |
| 122 | 63(b) Erection of 132 KV lightening arrester(110kvLA) | Numbers | 12.00 | 2,645 | 31,740 |
| 123 | 64(a) Supply of 240 V, AC distribution board.for TSS | Numbers | 1.00 | 95,577 | 95,577 |
| 124 | 64(b) Installation of 240 V, AC distribution board.for TSS | Numbers | 1.00 | 1,751 | 1,751 |
| 125 | 65(a) Supply of 110V DC distribution board | Numbers | 1.00 | 50,390 | 50,390 |
| 126 | 65(b) Erection of 110V DC distribution board | Numbers | 1.00 | 1,246 | 1,246 |
| 127 | 66(a) Supply of PVC insulated and sheathed copper unarmoured cable size 7 core 2.5 sqmm. | Metre | 3700.00 | 333 | 12,32,100 |
| 128 | 66(b) Installation of PVC insulated and sheathed copper unarmoured cable size 7 core 2.5 sqmm. | Metre | 3700.00 | 30 | 1,11,000 |
| 129 | 67(a) Supply of PVC insulated and sheathed copper unarmoured cable size 10 core 2.5 sqmm. | Metre | 550.00 | 465 | 2,55,750 |
| 130 | 67(b) Installation of PVC insulated and sheathed copper unarmoured cable size 10 core 2.5 sqmm. | Metre | 550.00 | 32 | 17,600 |
| 131 | 68(a) Supply of PVC insulated and sheathed copper unarmoured cable size 4x4 sqmm. | Metre | 400.00 | 313 | 1,25,200 |
| 132 | 68(b) Installation of PVC insulated and sheathed copper unarmoured cable size 4x4 sqmm. | Metre | 400.00 | 32 | 12,800 |
| 133 | 69(a) Supply of PVC insulated and sheathed copper unarmoured cable size 2x4 sqmm. | Metre | 4500.00 | 177 | 7,96,500 |
| 134 | 69(b) Installation of PVC insulated and sheathed copper unarmoured cable size 2x4 sqmm. | Metre | 4500.00 | 32 | 1,44,000 |
| 135 | 70(a) Supply of PVC insulated and sheathed copper unarmoured cable size 2x2.5 sqmm. | Metre | 2200.00 | 123 | 2,70,600 |
| 136 | 70(b) Installation of PVC insulated and sheathed copper unarmoured cable size 2x2.5 sqmm. | Metre | 2200.00 | 26 | 57,200 |
| 137 | 71(a) Supply of Al. XLPE Cable 2 core 300 Sq.mm | Metre | 145.00 | 1,510 | 2,18,950 |
| 138 | 71(b) Laying , testing and commissioning of Al. XLPE Cable 2 core 300 Sq.mm | Metre | 145.00 | 54 | 7,830 |
| 139 | 72(a) Supply of 25 KV/240V (LT), 50KVA Auxiliary transformer oil filed type with complete accessories as per latest RDSO Spec. | Numbers | 2.00 | 2,87,044 | 5,74,088 |
| 140 | 72(b) Erection of 25 KV/240V (LT), 50KVA Auxiliary transformer oil filed type with complete accessories as per latest RDSO Spec. | Numbers | 2.00 | 12,498 | 24,996 |
| 141 | (73) Supply & Erection of Fire buckets 10Ltrs | Each | 6.00 | 552 | 3,312 |
| 142 | (74) Supply & Erection Fire bucket stands for 3 Buckets. | Each | 2.00 | 3,681 | 7,362 |
| 143 | 75(a) Supply of MS angle iron for supporting cable | Kg | 1832.06 | 94 | 1,72,213.64 |
| 144 | 75(b) Erection of MS angle iron for supporting cable | Kg | 1832.06 | 9 | 16,488.54 |
| 145 | 76(a) Supply of various type of Indication Board and caution boards, safety Board, TSS Name Board, key Box, trilingual, Shock Treatment Chart, Stretcher and T&P Etc., | Set | 1.00 | 2,69,944 | 2,69,944 |
| 146 | 76(b) Erection of various type of Indication Board and caution boards, safety Board, TSS Name Board, key Box, trilingual, Shock Treatment Chart, Stretcher and T&P Etc., | Set | 1.00 | 22,048 | 22,048 |
| 147 | 77(a) Fault Locator panel for TSS including two numbers of Calculating Unit (CU) and two numbers of Measuring Unit (MU) :-Supply | Numbers | 1.00 | 46,34,053 | 46,34,053 |
| 148 | 77(b) Fault Locator panel for TSS including two numbers of Calculating Unit (CU) and two numbers of Measuring Unit (MU):-Erection | Numbers | 1.00 | 2,43,897 | 2,43,897 |
| 149 | 78(a) Fault Locator wall mount rack for OFC hut:-Supply | Numbers | 1.00 | 2,64,803 | 2,64,803 |
| 150 | 78(b) Fault Locator wall mount rack for OFC hut:-Erection | Numbers | 1.00 | 13,937 | 13,937 |
| 151 | 79(a) Supply of Control & LED Indication panel for operation of motorised isolator | Numbers | 1.00 | 16,850 | 16,850 |
| 152 | 79(b) Erection of Control & LED Indication panel for operation of motorised isolator | Numbers | 1.00 | 2,094 | 2,094 |
| 153 | 80(a) Supply of check metering panel with2PT+set of 3 phase (ABT Meter). | Numbers | 1.00 | 9,87,005 | 9,87,005 |
| 154 | 80(b) Erection of check metering panel with2PT+set of 3 phase (ABT Meter). | Numbers | 1.00 | 69,474 | 69,474 |
| 155 | 81(a) Supply of approved Make ''Dry chemical powder'' type fire extinguisher 5Kgs capacity cofirming to latest IS:2171. | Each | 4.00 | 3,988 | 15,952 |
| 156 | 81(b) Erection of approved Make ''Dry chemical powder'' type fire extinguisher 5Kgs capacity cofirming to latest IS:2171. | Each | 4.00 | 48 | 192 |
| 157 | (82) Supply of 25kV Support Insulator & Tie rod insulator. | Each | 18.00 | 39,539 | 7,11,702 |
| Schedule total | ₹38,36,84,693.03 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
AnnexureVI-A-BankguaranteeasBidsecurity.pdf
ATTACHMENT
Annexure-ITenderFormfirstSheet.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
Annexure-V.pdf
ATTACHMENT
Annexure-VIB.pdf
ATTACHMENT
SummaryofMandatoryDocumentstobeattached.pdf Summary of Mandatory Documents to b
ATTACHMENT
TBooklet11-2026_1.pdf
ATTACHMENT
Mergedespprojectsheet.pdf
ATTACHMENT
PC-JMNRsinglelinediagram.pdf
ATTACHMENT
ToAllConcern.pdf
ATTACHMENT
Soleproprietorcertificate.pdf
ATTACHMENT
SummaryofMandatoryDocumentstobeattached.pdf
ATTACHMENT
CORRECTIONSLIPS1TO10_compressed.pdf
ATTACHMENT
ACS-11.pdf
ATTACHMENT
MOM-Pre-Bid11-2026.pdf
CORRIGENDUM
TBooklet11-2026CorrectedwithSplCondn.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .