Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 478 3 834004 | RANCHI | JHARKHAND | 834004 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical AT SELECTED DHORI COLLIERY POST PHUSRO BAZAR DIST BOKARO JHARKHAND 829144 | PHUSRO BAZAR | BOKARO | JHARKHAND | 829144 | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical AT AWADH CINEMA ROAD PHUSRO BAZAR PO PHUSRO BAZAR DIST BOKARO JHARKHAND 829144 | BOKARO | JHARKHAND | 829144 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
Refer Docs
EMD Value
₹5,700
Closing Date
30 Mar 2026, 11:00 amClosed
STAFF OFFICER EnM
STAFF OFFICER EnM Dhori Area
Fresh wiring in Shiv Mandir and Community hall near Singh nagar petrol pump under G.M. unit, Dhori Area
2026_CCL_357128_2
GM(D)/SO(EnM)/NIT/2025-26/34 dtd- 19.03.2026
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
GM Unit
Please refer tender documents
2 documents required · 2 mandatory
₹5,700
9 May 2026
19 Mar 2026
31 Mar 2026
20 Mar 2026
30 Mar 2026
20 Mar 2026
20 Mar 2026 - 25 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 0.1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A a) Bulb point | 47 | points | - | - |
| 0.2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A b) Tube point | 16 | points | - | - |
| 0.3 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required: Group A c) Fan point | 12 | points | - | - |
| 0.4 | Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep (nominal size) on surface in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). | 12 | Each | - | - |
| 0.5 | Supplying and fixing metal box of 180 mm x 100 mm x 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. | 6 | Each | - | - |
| 0.6 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, ‘’C’’ curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole & neutral | 4 | Each | - | - |
| 0.7 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/isolator). : 6 way, double door. | 1 | Each | - | - |
| 0.8 | Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 3 x 1.5 sq.mm | 182 | Mtrs. | - | - |
| 0.9 | Supplying and drawing following sizes FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed steel/ PVC conduit as required. : 3 x 2.5 sq.mm | 155 | Mtrs. | - | - |
| 1 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 Amp TP&N. | 1 | Each | - | - |
stage.html
html • 0.03 MB
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.24 MB
BOQ_369997.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .