| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹38.4 L+₹2.9 L (8.07%)Rejected-Finance GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L2 | Rejected-Finance Quoted high rates | |
| 3 | L3₹38.5 L+₹3.0 L (8.33%)Rejected-Finance | L3 | Rejected-Finance Quoted high rates | |
| 4 | L4₹39.1 L+₹3.6 L (10.0%)Rejected-Finance SIKAR RAJASTHAN 332311 INDIA UDYAM RJ 30 0022665 | SIKAR | RAJASTHAN | 332311 | L4 | Rejected-Finance Quoted high rates | |
| 5 | L5₹41.0 L+₹5.4 L (15.3%)Rejected-Finance | L5 | Rejected-Finance Quoted high rates |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
13 Jul 2024, 6:00 pmClosed
Col Shery Goel, CWE
HQ CWE Bikaner, Bikaner Mil Stn
Repair/Maint of Summer Appliances, Deep Freezer, Water Cooler and (AC) Air Conditioner at MFFR under GE (N) Bikaner
2024_MES_660074_1
CA No CWE BKN-Token No 29/2024-2025
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (N) Bikaner
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (N) Bikaner
₹98,000
Yes
30 Aug 2024
15 Jun 2024
20 Jul 2024
15 Jun 2024
13 Jul 2024
29 Jun 2024
15 Jun 2024 - 20 Jun 2024
Amount
REPAIR TO WATER COOLERS Taking down old unserviceable compressor including bushes, grommets sleeves, washers, mounting rubbers, nuts, bolts, terminal cover brazing and clips from existing water coolers of Make : Voltas /Usha/ Sidhwal/ Blue Star capacity cooling 60/120 litres and 150/180 litres complete all as specified and directed.
Supply and fixing new hermetically sealed unit (compressor) including provn of new bushes, grommets, sleeves, washers, mounting rubbers, nuts and bolts, terminal covers, brazing and clips and necessary accessories for water cooler capacity 150/180 Litres complete all as specified and directed. Make : Emerson/LG/Godrej/Tecumseh/kirloskar. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
Supply and fixing new hermetically sealed unit (compressor) including provn of new bushes, grommets, sleeves, washers, mounting rubbers, nuts and bolts, terminal covers, brazing and clips and necessary accessories for water cooler capacity 60/120 Litres complete all as specified and directed. Make : Emerson/LG/Godrej/Tecumseh/kirloskar. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
Supply and fixing internal wiring with PVC insulated copper conductor of size 40/0.0076 sqmm including replacement of main lead 03 meter long, terminal clips, thimbles, 03 Pin plug top 15 Amps & soldering extra including taking down carefully existing internal wiring of existing water coolers complete all as specified and directed. Make of wire : Plaza/Finolex/Havell's.
M&L for cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134a after rectification of leakage in existing water coolers any capacity complete all as specified and as directed .
M&L for removing of old rusted worn out portion of sheet/ angle/ flat iron from base, front and top etc. of the water cooler/ refrigerators/ Air Conditioners and providing new mild steel sheet, angle iron /MS flat including necessary bending, welding, riveting etc, including making provn for mounting of fan motors, compressor and condenser complete all as specified and as directed.
M&L for complete removing old faded paint from steel surfaces of water cooler by scrappers, making the surface smooth including filling of filling materials and painting the surface of any description over 10cms in width of girth not other wise described with one coat of red oxide primers and two coats of synthetic enamel paint complete all as specified and as directed.
M&L for taking down defective fan motor from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers, nuts bolts and Refixing after reassembling and testing in existing water coolers for under mentioned Fan Motor of capacity 1/16 HP, 230 volts, Single Phase, 50 Hz complete all as specified and directed. Note: The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps.
M&L for taking down defective fan motor from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers, nuts bolts and Refixing after reassembling and testing in existing water coolers for under mentioned Fan Motor of capacity 1/32 HP, 230 volts, Single Phase, 50 Hz complete all as specified and directed. Note: The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps.
M&L for taking down defective fan motor from water coolers, dismantling the old burnt winding from the motor and rewinding with super enameled copper wire as per existing size including replacement of shaft, bushes mounting rubbers, nuts bolts and Refixing after reassembling and testing in existing water coolers for under mentioned Fan Motor of capacity 1/35 HP, 230 volts, Single Phase, 50 Hz complete all as specified and directed. Note: The unit rates quoted shall be deemed to be included replacement of minor spares such as rubbers, nuts, washers insulating materials and clamps.
M&L for Fan blades made out of aluminum as per sample and existing size of water cooler complete all as specified and directed.
M&L for taking down carefully fan motor from existing water coolers and providing new fan motor 1/35 HP, 230 volts, Single Phase, 50 Hz, including replacement of mounting legs complete all as specified and as directed. Make : Frac Master, Polor or Equivalent. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
M&L for taking down carefully fan motor from existing water coolers and providing new fan motor 1/25 HP, 230 volts, Single Phase, 50 Hz, including replacement of mounting legs complete all as specified and as directed. Make : Frac Master, Polor or Equivalent. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
M&L for taking down carefully fan motor from existing water coolers and providing new fan motor 1/16 HP, 230 volts, Single Phase, 50 Hz, including replacement of mounting legs complete all as specified and as directed. Make : Frac Master, Polor or Equivalent. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
M&L for taking down carefully fan motor from existing water coolers and providing new fan motor 1/10 HP, 230 volts, Single Phase, 50 Hz, including replacement of mounting legs complete all as specified and as directed. Make : Frac Master, Polor or Equivalent. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
Supply and fixing in replacement push cock (Stainless steel) for water cooler as per sample and existing size complete all as specified and as directed.
Supply and fixing thermostat for water cooler of any capacity and make as per existing complete all as specified and as directed.
Supply and fixing in replacement of Over Load Protection suitable for water cooler complete all as specified and as directed.
Supply and fixing in replacement of running capacitor 100/120 MFD (Make : Tibcon/ Sharda/ Epcos) complete all as specified and as directed.
Supply and fixing in replacement of capacitor 80/100 MFD (Make : Tibcon /Sharda /Epcos) complete all as specified and as directed.
Supply and fixing in replacement of capacitor 60/80 MFD (Make : Tibcon/Sharda /Epcos) complete all as specified and as directed.
Supply and fixing in replacement of capacitor 40/60 MFD (Make : Tibcon/ Sharda/ Epcos) complete all as specified and as directed.
Supply and fixing in replacement of capacitor 36 MFD (Make : Tibcon/ Sharda/Epcos) complete all as specified and as directed.
Supply and fixing in replacement of capacitor 15 MFD (Make : Tibcon/ Sharda/Epcos) complete all as specified and as directed.
Supply and fixing in replacement of capacitor 10 MFD (Make : Tibcon/ Sharda/ Epcos) complete all as specified and as directed.
Supply and fixing in replacement cable 3 core, copper conductor size 40/0.0076 for water cooler (Make : Plaza/ Finolex/ Kalinga) complete all as specified and as directed.
REPAIR TO AIR CONDITIONERS/INVERTED TYPE AIR CONDITIONERS Supply & fixing compressor 2 Ton capacity including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips including taking down unserviceable compressor 2 TR capacity from the window AC/Inverted Type Window AC/ split AC/Inverted Type Split AC of any make complete all as specified and directed. Make : Emerson/ LG/Godrej/ Tecumseh/ Kirlosar. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
Supply & fixing compressor 1.5 Ton capacity including bushes, grommets, sleeves, washers, mounting rubbers, nuts, bolts, terminal covers, brazing and clips including taking down unserviceable compressor 1.5 TR capacity from the window AC/Inverted Type Window AC/ split AC/Inverted Type Split AC of any make complete all as specified and directed. Make : Emerson/ LG/Godrej/ Tecumseh/ Kirlosar. Note : Gurantee card with original purchase voucher shall be produced by the contractor.
M&L for cleaning of complete existing gas system with CTC, testing of leakage, charging of refrigerant with R-134a after rectification of leakage in existing window type/Inverted Type Window AC/ Split/ Inverted Type Split Air Conditioners 1.5/2 TR capacities of make and model as per existing complete all as specified and as directed.
M&L for taking down of old unserviceable fan motor of any capacity from the window/ Inverted type window AC/ split/ Inverted type Split Air Conditioners 1.5/2 TR capacity and dismantling old unserviceable burnt winding wire and rewinding with super enameled copper wire of existing gauge and size including heat varnishes replacement of shaft, bearing and bush complete as found unserviceable after opening complete all as specified and as directed.
Maintenance, servicing and testing of split type AC/ Inverted type split AC, capacity upto 1.5/2 Ton, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters cleaning with VINICLEAN solution using pressure jet system with water, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/ repair to inter locking device for winter/summer to ensure cutting off of compressor/ heating in case of failure of blower motor including taking down and refixing in same position complete all as specified and directed. Note : Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc is deemed to be inclusive in the unit rates quoted by the contractor.
Supply and fixing in replacement of capacitor 50 MFD (Make : Tibcon/ Sharda/Epcos) complete all as specified and directed
Supply and fixing in replacement of running capacitor 45 MFD (Make : Tibcon/Sharda / Epcos) complete all as specified and directed
Supply and fixing in replacement of capacitor 6 MFD (Make : Tibcon/ Sharda/Epcos) complete all as specified and directed
Supply and fixing in replacement printed circuit board (PCB) kit for Split/ window / Inverted type window & split AC of any type complete all as specified and directed.
Supply and fixing in replacement of remote 1.5/2 Ton capacity window/ split /Inverted type window or split AC of any make / type complete all as specified and directed.
Taking down carefully the following spare parts from the existing Air Conditioner and providing new accessories/ spare parts as per existing as under :-
PVC filters for window/split AC/ Inverted Type AC
Contactor for Air Conditioner
Starting relay for Air Conditioner
S&F in replacement of burnt out transformer of 3 to 4 KVA voltage stabilizer of any make complete all as specified and directed.
Supply and laying PVC insulated stranded aluminium conductor cable heavy duty 1100 Volts grade served with an inner sheathing of PVC tape & overall PVC sheathed 06 Sqmm 2 core nominal cross section including taking down unserviceable cable complete all as specified and directed. Make : Asian Cable Co./Finolex/Polycab
Taking down unserviceable Exhaust rooler of split AC capacity 1.5 TR from existing place and supply and fixing new Exhaust rooler of split AC 1.5 TR capacity of including bush/ bearing as per existing type complete accessories fixing in existing place complete all as specified and as directed. Make : Sumsung
Supply & Fixing in replacement of Indoor Unit complete with all necessary for 1.5 TR Split type Air Conditioner complete all as specified and directed.
Supply & Fixing in replacement of Outdoor Unit complete with all necessary for 1.5 TR Split type Air Conditioner complete all as specified and directed.
Supply & Fixing in replacement of Outdoor Unit complete with all necessary for 2.0 TR Split type Air Conditioner complete all as specified and directed. Note : Indoor/outdoor unit will be deposit in AGE MFFR yard.
REPAIR TO DESERT COOLERS Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and apply one coats of black bituminous paint complete all as specified and directed.
All as per serial item No. 43.00 here-in-before but applying spray painting with synthetic enamel paint to external surfaces of desert coolers including steel grills, side panel etc complete all as specified amd as directed. Make of paint burger/asain and colour as approved.
Taking down carefully old unserviceable water pumps heavy duty of capacity 1/70 HP, 230 volts, 50 Hz, single Phase, providing new submersible type water pump complete all as specified and directed.
Taking down carefully fan motor from existing desert coolers and providing new fan motor kit 1/5 HP to 1/6 HP, 230 volts, 50 Hz, including replacement of mounting legs & nuts bolts with capacitor 4 Mfd as required at site complete all as specified and directed. Make : Khaitan/ Indo/ Cool Home/victor/CG.
Taking down carefully fan motor 1/5 HP to 1/6 HP 230 volts, 50 Hz, from existing desert coolers of each camp at MFFR and refixing the same camp fan motor after rewinding with super enameled copper wire of existing size complete including replacement of bush/bearing mounting legs & nuts bolts capacitor 4 Mfd as required at site complete all as specified and directed. Make : Milan/Chetak Note:- Contractor will be arranged all required T&P (winding machine) repair for desert cooler motor/sevicing i.e winding/greasing /oiling in AGE MFFR yard.
Supply and Fixing in replacement capacitor for desert cooler 4 MFD, 230 volts (Make : Asian/ Tibcon/ Epcos) complete all as specified and directed.
Supply and Fixing in replacement GI sheet as per existing guage front grill including nuts bolts and washers suitable for 18/20" sweep desert coolers including necessary wire connection, regulator & on/off switch etc reqd at site, coolers all as specified and directed. Make-Alka/kinark.
Taking down part of desert cooler old rusted and M&L for bottom tank complete as per existing size 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required for fixing etc complete all as specified and as directed.
Taking down part of desert cooler old rusted and M&L for Top cover as per existing size 20 gauge GI plain sheet class-III including cost of riveting welding, nuts and bolts as required for fixing etc complete all as specified and as directed.
M&L for side panels as per existing size complete all as specified and as directed.
Supply and fixing in replacement of wood wool pad for desert coolers (set of three) complete all as specified and as directed.
Supply and fixing in replacement of Honey comb type pad for desert cooler (set of three) as per site requirement of any size and type all as specifed and directed.
Supply and fixing in replacement of supporting Jali for desert coolers (set of three) complete all as specified and as directed.
Supply and fixing in replacement of plug Top 3 pin, 5 Amp, 230 Volt complete all as specified and as directed.
Supply and fixing in replacement of plug Top 3 pin, 15 Amp, 230 Volt complete all as specified and as directed.
Supply and fixing in replacement of fan blades mode of aluminium for Desert cooler as per sample complete all as specified and as directed.
Supply and fixing in replacement cable 3 core, copper conductor size 23/0.0076 for Desert cooler Make : Plaza/ Finolex/ Kalinga complete all as specified and as directed.
Taking down old unserviceable PVC flexible tubing with distributor and elbows and providing new PVC flexible tubing with distributor and elbows for desert coolers complete all as specified and directed.
Supply and fixing in replacement tap mounting with nipple 1/2" as per sample complete all as specified and as directed.
Supply and fixing in replacement water outlet nipple with washers and check nuts (copper/brass) complete all as specified and directed.
REPAIR TO DEEP FREEZER Taking down unserviceable compressor form deep freezer including bushes, grommets sleeves, washers, mounting rubbers, nuts, bolts, terminal cover, brazing and clips from existing deep freezers of capacity 320 Litre to 405 Litre, Make : Voltas / Usha/ Sidhwal / Blue Star complete all as specified and directed.
Supply and fixing Compressor suitable for deep freezer 320 litres with necessary accessories including provn of new bushes, grommets, sleeves, washers, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and directed. Make : Emerson Model No CAJ 34/KCE 444 HAG / LG/ Godrej/Tecumseh. Note : Gurantee card and test certificate shall be produced by the contractor.
Supply and fixing Compressor suitable for deep freezer 405 litres with necessary accessories including provn of new bushes, grommets, sleeves, washers, mounting rubbers, nuts and bolts, terminal covers, brazing and clips complete all as specified and directed. Make : Emerson Model No CAJ 34/KCE 444 HAG / LG/ Godrej/Tecumseh. Note : Gurantee card and test certificate shall be produced by the contractor.
M&l for cleaning of complete deep freezer existing gas system with CTC, testing of leakage, charging of refrigerant with R-134a/ R-600a (as per site requirement) after rectification of leakage in existing deep freezer of any capacity, make and model as per existing complete all as specified and as directed.
REPAIR TO FAN Taking down ceiling fan for repair/ serviceing (i.e. greasing/ oiling etc.) size 1200/1400 mm sweep of any make and any type model, sealing cable end with tape, dismantling the blades, removing fan and deposite the blades/motor to store for repairing/serviceing complete all as specefied and as directed. Note : If the contractor fail to rectify the complaint (repair of ceiling fan, winding and servicing) within 72 hours. He will be charged Rs. 150/- per complaint per day and same shall be recovered from his RAR. The contractor has to setup repair workshop (winding and servicing) of ceiling fans inside in Mil contonment area.
Re-winding of ceiling fan of size 1200/1400mm sweep with super enameled copper winding wire of gauge as per existing size /No. of turns confirming to IS, including varnishing the motor windings with best quality varnish complete all as specefied and as directed. (Make : Milan/ Atlas/ Chetak)
S&F in replacement of ball bearing of size/No. 6201 confirming to IS complete all as specefied and as directed. (Make: NBC/SKF)
S&F in replacement of ball bearing of size/No. 6202 confirming to IS complete all as specefied and as directed. (Make: NBC/SKF)
S&F in replacement of ball bearing of size/No. 6203 confirming to IS complete all as specefied and as directed. (Make: NBC/SKF)
S&F in replacement of brass bush suitable for ceiling fan of any make and model confirming to IS complete all as specefied and as directed.
S&F in replacement of shaft for ceiling fan as per existing size and shape complete all as specefied and as directed.
S&F fabricated down rod made out of 15mm dia MS Pipe medium duty 60cm long duly painted including nut, bolt & washer etc and including drilling holles on top and bottom for ceiling fan fixing with fan hooks and ceiling fan respectively as reuired suitable for 1200/1400mm sweep of ceiling fan complete all as specified and directed.
S&F in replacement stepped type electronic fan regulator flush type on existing laminated sheet as per requirement including taking down old fan regulator complete all as specified and as directed.
S&F in replacement D Clamp with nuts, bolts, quarter pin and rubber reel suitable for 1200/1400 mm sweep of ceiling fan all as required at site complete all as specefied and as directed.
S&F in replacement of condenser 2.5 MFD confirming to IS complete all as specefied and as directed.
Supply and fixing in replacement of flexible wire of size 23/0.0076 stranded copper conductor complete all as specefied and as directed.
S&F in replacement of PVC Canopies (Set of two) as required at site complete all as specefied and as directed.
REPAIR TO EXHAUST FAN Taking down and dismantling of exhaust fan size 250mm/ 350mm/450mm sweep of any make and model, opening the cover, separating the rotor and stator assembly, locating the fault and making the fan fully serviceable condition including replacing the defected worn out screw, flexible wire of size 23/0.0076, oiling/greasing the fan and re-assembling the same position and testing complete to the satisfaction of Engineer-in-Charge. Note : If the contractor fail to rectify the complaint (repair of exhaust fan, winding and servicing) within 72 hours. He will be charged Rs. 150/- per complaint per day and same shall be recovered from his RAR. The contractor has to setup repair workshop (winding and servicing) of exhaust fans inside in Mil contonment area.
Re-winding of exhaust fan size 250mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish complete all as specefied and as directed. (Make: Milan/ Atlas/ Chetak)
Re-winding of exhaust fan size 350mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish complete all as specefied and as directed. (Make: Milan/ Atlas/ Chetak)
Re-winding of exhaust fan size 450mm sweep with super enameled copper winding wire as per existing size confirming to IS including varnishing the motor windings with best quality varnish complete all as specefied and as directed. (Make: Milan/ Atlas/ Chetak)
S&F in replacement of blades of exhaust fan size 250mm duly approved by GE complete all as specefied and as directed.
S&F in replacement of blades of exhaust fan size 350mm duly approved by GE complete all as specefied and as directed.
S&F in replacement of blades of exhaust fan size 450mm duly approved by GE complete all as specefied and as directed.
S&F in replacement exhuast fan louver shutters of size 300mm and as per existing make complete all as specified and as directed.
S&F in replacement exhuast fan louver shutters of size 450mm and as per existing make complete all as specified and as directed.
Supply & fixing in replacement of PVC fresh air (Exhaust fan) of size 250mm/ 300mm sweep, 230 Volts, Single Phase, multi speed, including making connection upto including three core PVC insulated multi stranded copper conductor cable of size 1.5 sqmm wire from ceiling rose/connector to fan of length not less than 1.0 mtr complete including marking of MES number with synthetic enamel paint complete all as specified and directed.
M&L for cleaning and preparation of old surface of ceiling and exhuast fan complete of any size and insitu with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. complete all as specified and directed. Make of paint : Asian/berger/nerolac.
M/S SHREE SHYAM TRADERS
J.M.D. CONSTRUCTION CO.
Anu Trading Co
BALAJI PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .