Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹43.8 CrAccepted-AOC | ₹43.8 Cr | 1 | Accepted-AOC Being lowest bidder L1 |
| 2 | 2₹43.9 CrRejected-Finance NIRJULI SHORT CUT PO PS NIRJULI PAPUM PARE ARUNACHAL PRADESH 791109 | NIRJULI | PAPUM PARE | ARUNACHAL PRADESH | 791109 | ₹43.9 Cr | 2 | Rejected-Finance Second Lowest Bid |
| 3 | 3₹43.9 CrRejected-Finance | ₹43.9 Cr | 3 | Rejected-Finance Highest Bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical Non-responsive in evaluation sheet |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non-responsive in evaluation sheet |
Tender Value
₹43.9 Cr
EMD Value
₹43.9 L
Closing Date
4 Jan 2023, 10:00 amClosed
Executive Engineer, Tezu Division, PWD
Office of the Executive Engineer, Tezu Division, PWD
Construction of C.C. Road in Tezu Township
2022_PWDAP_942_1
TDW/NIT-15/SPA/2022-23/03
Open Tender
Civil Works – Roads
730 days
Tezu
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,000
EE PWD Tezu
₹43.9 L
Yes
Office of the Executive Engineer Tezu PWD
15 Mar 2023
20 Dec 2022
4 Jan 2023
20 Dec 2022
4 Jan 2023
20 Dec 2022
2 Jan 2023
Amount
SH:- Intermediate lane RCC Pavement - Length 19.220 Km
Dismatling Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately) By Manual Means A Bituminous courses
Dismantling of Fencing (Dismantling of barbed wire fencing/ wire mesh fencing including posts, foundation concrete, back filling of pit by manual means including disposal of dismantled material with all lifts and up to a lead of 1000 metres, stacking serviceable material and unserviceable material separately)
C.C. Pavement Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, for M40 Grade having minimum 28 days flexural strength of 4.5 Mpa, using approved admixtures, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. )
SH:- Double lane RCC Pavement - Length 3.355 Km
Dismantling Dismantling of Flexible Pavements (Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately) By Manual Means A Bituminous courses
Dismantling of Fencing (Dismantling of barbed wire fencing/ wire mesh fencing including posts, foundation concrete, back filling of pit by manual means including disposal of dismantled material with all lifts and up to a lead of 1000 metres, stacking serviceable material and unserviceable material separately)
C.C. Pavement Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, for M40 Grade having minimum 28 days flexural strength of 4.5 Mpa, using approved admixtures, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. )
SH:- Widening of Road for intermediate lane - Length 19.220 Km
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH:- Widening of road for double lane - Length 2.790 Km
Embankment Construction with Material Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2)
SH:- C.C. Side Drain - Length 2.899 Km(For both Sides)
Excavation in Soil by Manual Means. (Excavation for roadway in soil using manual means including loading in truck for carrying of cut earth to embankment site with all lifts and lead upto1000 metres.)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications B) PCC Grade M20
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications RCC Grade M20 Case-1 Using concrete mixer
Centring and shuttering including strutting, propping etc and removal of form work for : b) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc.
a) Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications
12 mm cement plaster 1 : 3 (1 cement : 3 fine sand).
Neat cement punning.
Providing weep holes in Brick masonry/Plain/Reinforced concrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing foce. Complete as per drawing and Technical specifications
SH. :- Construction of new culvert (Span 1.00 m) - 12 Nos.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.) Ordinary soil A) Manual Means (Depth upto 3 m)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plan/Reinforced cement concrete in sub structure complete as per drawing and technical specifications. a) PCC Grade M15 Height upto 5m
Supplying, fitting and placing HYSD bar reinforcement complete in super structure as per drawing and technical specification.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per drawing and Technical Specification. A) RCC Grade M20 Case-I Using Concrete Mixer a) Height upto 5m
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. a) Granular material
SH. :- SH: Widening of existing culvert @ 2.00 m on both sides - 12 Nos.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.) i) Ordinary soil A) Manual Means (Depth upto 3 m)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plan/Reinforced cement concrete in sub structure complete as per drawing and technical specifications. a) PCC Grade M15 Height upto 5m
Supplying, fitting and placing HYSD bar reinforcement complete in super structure as per drawing and technical specification.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. A) RCC Grade M20 Case-I Using Concrete Mixer a) Height upto 5m
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. a) Granular material
SH. :- Widening of existing culvert @ 1.00 m on both sides - 15 Nos.
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, backfilling the excavation earth to the extent required and utilising the remaining earth locally for road work.) i) Ordinary soil A) Manual Means (Depth upto 3 m)
PCC 1:3:6 in Foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)
Plan/Reinforced cement concrete in sub structure complete as per drawing and technical specifications. a) PCC Grade M15 Height upto 5m
Supplying, fitting and placing HYSD bar reinforcement complete in super structure as per drawing and technical specification.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. A) RCC Grade M20 Case-I Using Concrete Mixer a) Height upto 5m
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification. a) Granular material
SH:- Widening of Junction/Curves - 54 Nos.
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, for M40 Grade having minimum 28 days flexural strength of 4.5 Mpa, using approved admixtures, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing. )
NABAM TULLON LLP
Ms Yuma Enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid