Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.0 LAccepted-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | L1 | Accepted-AOC OK | |
| 2 | L2₹20.5 L+₹93,596 (4.79%)Rejected-AOC 49 PARAG DAS STREET SEUJI LAKSHMI PATH PANDU SADILAPUR KAMRUP M GUWAHATI 781012 ASSAM | KAMRUP METRO | ASSAM | 781012 | L2 | Rejected-AOC OK | |
| 3 | L3₹20.9 L+₹1.4 L (6.96%)Rejected-AOC | L3 | Rejected-AOC OK | |
| 4 | L4₹21.0 L+₹1.5 L (7.53%)Rejected-AOC | L4 | Rejected-AOC OK | |
| 5 | L5₹21.1 L+₹1.6 L (8.15%)Rejected-AOC | L5 | Rejected-AOC OK |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
5 Aug 2021, 6:00 pmClosed
AGE (I) AF Digaru
AGE (I) AF Digaru
REPAIR / MAINT OF LT FEEDER PILLAR BOX / PANEL, ELECTRIC POLE, CABLE AND OTHER MISC ITEMS AT AF STN DIGARU.
2021_MES_460548_1
8494/E8 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
DIGARU
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹36,000
Yes
16 Oct 2021
16 Jul 2021
7 Aug 2021
16 Jul 2021
5 Aug 2021
31 Jul 2021
Amount
Dismantling of UG cable any size duly disconnecting all electrical connections including taking down all accessories Complete all as specified & directed by Engr-in-Charge.
Supply, laying, jointing and testing in repairs XLPE insulated, PVC bedded, Galvanized steel strip or wire armoured underground heavy duty electric power cable with stranded aluminum conductor 1100 volts grade, laid in trenches / duct / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of cross sectional area 50 Sqmm 3.5 core complete all as specified and as directed.
All as per item No-2 here in above but of size 70 Sqmm x3.5 core complete all as specified and as directed.
All as per item No-2 here in above but of size 95 Sqmm x3.5 core complete all as specified and as directed.
All as per item No-2 here in above but of size 240 Sqmm x3.5 core complete all as specified and as directed.
Excavation in trenches, not exceeding 1.50m wide and not exeeding 1.50m in depth for foundations, trenches of cable or pipe lines etc or and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all specified and as directed.
Removing excavated materials (soil) to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all specified and as directed.
Supply and laying Sand filling under trench for covering of UG Cables complete all as specified and as directed.
Supply and laying well burnt sub class- B bricks old size bricks, laid flat dry, in trenches with width of the bricks laid to the axis of cable for cable protection complete all as specified and as directed.
M&L for Cleaning the area including uprooting of weeds/grass and removing creepers from fencing or poles / posts and brooming the complete area of sub station around panels,transformers and four pole structures all as specified & directed.
Dismantling of MCCBs of any size any type duly disconnecting all electrical connections including taking out all accessories complete all as specified & directed by Engr-in-Charge.
S&F in repairs MCCB 63 Amps, 4 Pole, 25 KA breaking capacity, "A" Frame size ,Adjustable Thermal & Fixed magnetic setting.Make:Havells, cat part No- IHLASF0063 or equivalent make of L&T/ C&S/ Scheneider )
All as per item No-13 above but MCCB 125 Amps, 4 Pole, 35 KA breaking capacity, "A" Frame size , Adjustable Thermal & Adjustable magnetic setting.Make:Havells, cat part No- IHLASDCF0125 or equivalent make of L&T/ C&S/ Scheneider )
S&F Bollard light with die cast aluminium housing and high corrosion resistant surface finish, with B-22 holder type including 9W LED bulb 6500K, acrylic diffuser, IP-65 protection, total height from ground 0.8m, with fixing bolts, including dismantling old U/S light and fitting complete all as specified and directed. Make: Century LED Magik Cat Part No. OGFB00001042 or Equivalent in Havells/Bajaj/Philips
S & F in repair GI pipe “Light Grade” in trenches, under floors, roads, along poles or walls including suitable size clamps for protection of cables and sealing ends complete all as specified and directed for the e following pipes as under:
(a) 20 MM BORE
(b) 40 MM BORE
(c) 50 MM BORE
Dismantling of steel pole/struts of any size & type duly disconnecting all electrical connections including taking down cross arms / ACSR conductors etc. Complete all as specified & directed by Engr-in-Charge.
Supply, erecting and fixing in true vertical position GI poles complete with GI base plate, finial taper plug,bolts,nuts & screws as specified type 410 SP-31 (9.0 metres long) , incl earthwork for 60x60cm pit of 1.65m depth and PCC 1:4:8 bed 15cm at bottom and PCC 1:3:6 till ground level and PCC 1:2:4 for coping above ground for 30cm including removal of excavated earth to a distance n.exc 50m and depositing as directed by Engineer-in-charge complete all as specified and directed.
Dismantling and taking down of unserviceable street light fittings of any watt and any make and removing of dismantled material from work site complete all as specified and as directed.
S&F street light fittings 60 Watt LED new generation energy saving roadway luminaire IP-66 degree of protection complete all as specified and as directed. Make: Bajaj/ Havells/HPL/CG/Surya
S&F in repair bracket suitable for pole mounting for flood light mounting on GI/MS pole at desired height, 02 Nos mounting slots opposite at each other on one pole, including MS clamp and painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and as directed.
S&F in repair of polycarbonate cable junction box of size 300X200X105mm with complete three phase terminal with connecting clamps,nuts,screws etc complete with fixing arrangement complete all as specified and as directed. Make : Syntax or equivalent
S&F in repair 50 watt Jeta Neo Energy saving,environmental friendly,long life,LED flood light luminaire with IP-66 degree of protection complete all as specified and as directed .( Make - Havells or equiv of Bajaj/Surya/ HPL.)
Dismantling existing unsv LT panel from HQ Area signal section and Supply install commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel indoor type CPRI approved, fully comparted type , fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, with IP-65 Protection complete, with provn of front Double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation 30 CM below the ground and 20 CM above the ground, duly powder coated paint over one coat of red oxide primer complete all as directed. Comprising of Following
i) Copper Bus bar TPN 600 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of Make Denson/M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 Set. ii) MCCB 400 Amp Ics 36 KA , 4 Pole, 415 V, 50 Hz, with thermal, magnetic release adjustable- 1 Nos . iii) MCCB 250 Amp, Ics 25 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 2 Nos. iv) MCCB 63 Amp, Ics 25 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 1 Nos. iv) Indicator lamp RYB- 1 Set. v) Multifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96 x96 sqmm flush mounted case, accuracy class 1.0- 01 No. v) Danger notice plate riveted on the outer body 440 volt. Note: (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication.
Dismantling existing unsv LT panel from HQ Area guard room and Supply install commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel indoor type CPRI approved, fully comparted type , fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, with IP-65 Protection complete, with provn of front Double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation 30 CM below the ground and 20 CM above the ground, duly powder coated paint over one coat of red oxide primer complete all as directed. Comprising of Following
i) Copper Bus bar TPN 600 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of Make Denson/M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 Set. ii) MCCB 400 Amp Ics 36 KA , 4 Pole, 415 V, 50 Hz, with thermal, magnetic release adjustable- 1 Nos . iii) MCCB 200 Amp, Ics 25 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 2 Nos. iv) MCCB 100 Amp, Ics 25 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 1 Nos. iv) Indicator lamp RYB- 1 Set. v) Multifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96 x96 sqmm flush mounted case, accuracy class 1.0- 01 No. v) On load changeover switch 4 pole 400 amps 415 V AC, 50 Hz- 01 Nos. vi)Danger notice plate riveted on the outer body 440 volt. Note: (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication
Dismantling existing unsv LT panel from HQ Area admin block and Supply install commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel indoor type CPRI approved, fully comparted type , fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, with IP-65 Protection complete, with provn of front Double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation 30 CM below the ground and 20 CM above the ground, duly powder coated paint over one coat of red oxide primer complete all as directed. Comprising of Following
i) Copper Bus bar TPN 400 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of Make Denson/M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 Set. ii) MCCB 200 Amp Ics 25 KA , 4 Pole, 415 V, 50 Hz, with thermal, magnetic release adjustable- 1 Nos . iii) MCCB 125 Amp, Ics 25 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 2 Nos. iii) Indicator lamp RYB- 1 Set. iv) tifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96 x96 sqmm flush mounted case, accuracy class 1.0- 01 No. v) Danger notice plate riveted on the outer body 440 volt. Note: (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication
Dismantling existing unsv LT panel from MES Complex and Supply install commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel indoor type CPRI approved, fully comparted type , fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, with IP-65 Protection complete, with provn of front Double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation 30 CM below the ground and 20 CM above the ground, duly powder coated paint over one coat of red oxide primer complete all as directed. Comprising of Following
i) Copper Bus bar TPN 200 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of Make Denson/M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 Set. ii) MCCB 125 Amp Ics 25 KA , 4 Pole, 415 V, 50 Hz, with thermal, magnetic release adjustable- 1 Nos . iii) MCCB 100 Amp, Ics 25 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 1 Nos. iv) MCCB 40 Amp, Ics 16 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 1 Nos. iv) Indicator lamp RYB- 1 Set. v) Multifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96 x96 sqmm flush mounted case, accuracy class 1.0- 01 No. v) On load changeover switch 4 pole, 125 amp, 415 v AC, 50 hz-01 Nos. vi) Danger notice plate riveted on the outer body 440 volt. Note: (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication
Dismantling existing unsv LT panel from HQ Area Offr mess area and Supply install commissioning and testing of factory made type, dust and vermin proof, totally enclosed control panel indoor type CPRI approved, fully comparted type , fabricated out of 3.15mm thick CRCA sheet, duly painted with epoxy powder coating with 10 tank process, with IP-65 Protection complete, with provn of front Double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5 mm and legs grouted on PCC foundation 30 CM below the ground and 20 CM above the ground, duly powder coated paint over one coat of red oxide primer complete all as directed. Comprising of Following
i) Copper Bus bar TPN 200 Amp of suitable length and section covered with coloured heat shrinkable anti track insulation tape of Make Denson/M-seal or equivalent of finished thickness not more than 1mm and fixed on epoxy base post insulator of both dia and height not less than 40mm- 01 Set. ii) MCCB 125 Amp Ics 25 KA , 4 Pole, 415 V, 50 Hz, with thermal, magnetic release adjustable- 1 Nos . iii) MCCB 63 Amp, Ics 16 KA, 4 pole, 415 V, 50 Hz with adjustable thermal and fixed magnetic release- 3 Nos. iii) Indicator lamp RYB- 1 Set. iv) Multifunction meter digital compatible to measure voltage, current, PF, frequency with 3 lines display LCD in 96 x96 sqmm flush mounted case, accuracy class 1.0- 01 No. v) Danger notice plate riveted on the outer body 440 volt. Note: (a) All existing and new connections of incoming/outgoing cables shall be done through appropriate size of copper thimbles (b) Drawing, circuit diagram and all materials/instruments for panel shall be approved by AGE(I) before fabrication
M & L for increasing height of LT panel using MS angle iron of size 50x50x6mm up to 3.5 feet using gas welding including cutting and 2 coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
Nripen Kalita
M/s J H Associates
M/s Capital Traders
M/S DAS CONSTRUCTION
FRIENDS ENTERPRISE
M/S Trio Engineers And Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .