Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | ₹23.7 L Quoted ₹24.9 L | L1 | Accepted-AOC being L1 bidder |
| 2 | L2₹28.4 L+₹3.6 L (14.4%)Rejected-Finance A 63 ELDECO COUNTY PHASE II RAJGARH JHANSI U P 284135 | JHANSI | JHANSI | UTTAR PRADESH | 284135 | ₹28.4 L+₹3.6 L (14.4%) | L2 | Rejected-Finance not become lowest bidder |
| 3 | L3₹28.5 L+₹3.6 L (14.5%)Rejected-Finance | ₹28.5 L+₹3.6 L (14.5%) | L3 | Rejected-Finance not become lowest bidder |
| 4 | L4₹29.1 L+₹4.2 L (17.0%)Rejected-Finance 840 1B MADHUR VIHAR COLONY CIVIL LINES JHANSI UP 284 001 | JHANSI | JHANSI | UTTAR PRADESH | 284001 | ₹29.1 L+₹4.2 L (17.0%) | L4 | Rejected-Finance not become lowest bidder |
| 5 | L5₹29.6 L+₹4.7 L (18.9%)Rejected-Finance | ₹29.6 L+₹4.7 L (18.9%) | L5 | Rejected-Finance not become lowest bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
30 May 2024, 6:00 pmClosed
Major Sunny Kumar Attri
Garrison Engineer Jhansi
REPAIRS AND RENEWALS TO MCB DBs, MCBs, SERVICE CONNECTIONS, SUB MAIN WIRING, REWIRING WORKS AND OTHER MISC WORKS AREA IN ZONE A AND B AREA AT JHANSI CANTT UNDER AGE E/M AT GE JHANSI
2024_MES_653565_1
GE/JHA/TOK/28 OF 2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Jhansi
As per NIT and Tender Documents
9 documents required · 9 mandatory
₹500
Yes
GE Jhansi
₹70,000
Yes
5 Jul 2024
11 May 2024
1 Jun 2024
11 May 2024
30 May 2024
24 May 2024
11 May 2024 - 23 May 2024
Amount
Taking down carefully existing copper/aluminium point wiring (light, fan, socket or power) complete of any description including fitting such as switches, ceiling roses, pendants, tube light fitting, regulators, sockets, bell push and call bell wooden boards, laminated sheets from sunken boxes, boards, shades light fitting etc and making good the disturbed surfaces of walls, floors, ceiling etc with cement plaster, putty and paint to match with the existing surface complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLSH insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLSH insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of elctrogalvanised steel terminal box of thickness not less than 18 SWG / with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated sheet fixed with brass/GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed for the following points:-
One light / ceiling fan / exhaust fan / call bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per item No. 2.00 here-in-before but with 2.5 sqmm FRLSH copper wire with 2.5 Sqmm FRLSH copper earth wire for one 16A socket point controlled by one 16A switch on independent board .
All as per srl item No 2 here-in-before but with 4 sq mm FRLSH copper wire with 4 Sqmm FRLSH copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
All as per item No. 2.00 here-in-before but with 2.5 Sqmm one 16A socket point controlled by one 16A switch on independent board but just below / above the existing socket points / DBs up to one meter distance in the same vertical plane.
M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length)
2 runs X 2.5 Sqmm + 1 run X 2.5 Sqmm (earth wire).
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
2runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire)
Notes for item No. 3 : (i) Quoted rate shall deemed to include the cost of cutting chases on wall/floor for concealed conduit wiring and making good with cement plaster, putty and paint to match with the existing surface. (ii) If any beam / column / Rock wall is encountered while cutting chases, that particular portion may be provided with PVC casing & capping or surface conduit for drawing cables and surface PVC gang box fully enclosed type for mounting switches, sockets & regulators etc to avoid any damage to the structure. (iii) No cutting shall be done on ceiling for laying PVC conduit for ceiling fan point wiring. Surface conduit or PVC casing capping may be used in that portion.
M&L for sub main wiring along with earth wire with FRLSH insulated copper conductor, single core cable drawn through in & incl PVC trunking of size not less than 32x12mm ISI marked ivory white and its all accessories including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for the following sizes:- (Note: Three runs of copper cable and one run of PVC casing caping shall be measured as one unit length)
2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire)
2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire)
S&F of Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F of Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F of electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed.
S&F of Socket 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
S&F of Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F of Lamp holder, angle type with metal ring, PVC/Polycarbonate body complete all as specified and directed.
S&F of Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
Taking down light fitting of any capacity and any size and in any position complete all as specified and directed.
S&F of integrated LED batten 20 watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built-in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5sqmm from ceiling rose to connector of fitting complete all as specified and directed.
S&F of LED street/security light fitting 30 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
S&F of LED street/security light fitting 45 watts with high efficiency long life LEDs with In-built electronic driver and surge protection upto 10 Kv complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including provision of GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
S&F LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type (Cool white & warm white) gypsum ceiling with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type (Cool white & warm white) gypsum ceiling with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed by Engineer-in-Charge.
S&F of modular MCB protected plug and socket board in sheet steel enclosure with 25A rated mini MCB and 20A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed.
Taking down unserviceavle VTPN/ TPN DB with MCB's of any make/capacity complete all as specified and directed by Engr-in-Charge.
S&F of MCCB / MCB distribution board, Vertical TPN, 4 way, 415 V, 3 phase, AC with MCCB as incomer and MCBs as outgoing in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surfacecomplete all as specified and directed. Note: MCCB / MCBs shall be measured and paid separately.
S&F of MCB distribution board, TPN, 4 way, 415 V, 3 phase, AC in sheet steel powder painted enclosure double door type with minimum IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface complete all as specified and directed. Note: MCBs shall be measured and paid separately.
Taking down unserviceavle Sheet metal box & MCB DB SPN with MCB's of any make/capacity complete all as specified and directed by Engr-in-Charge.
All as per item No. 22 here-in-before but SPN, 12 way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
All as per item No. 22 here-in-before but SPN, 8 way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
All as per item No. 22 here-in-before but SPN, 4way, 230 V, 1 phase, AC Note: MCBs shall be measured and paid separately.
S&F of MCCB 100A, 16 KA, 4 Pole, 415 V, 50 Hz with fixed thermal magnetic release complete all as specified and directed.
S&F of MCB 100A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed.
S&F of MCB 63A, 10 KA, TPN, 415 V, 50 Hz complete all as specified and directed.
S&F of MCB 40A, 10 KA, SPN, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
S&F of MCB 6 - 32A, 10 KA, single Pole, 'C' curve, 240 V, 50 Hz complete all as specified and directed.
Taking down ceiling fan/exhaust fan of any sweep, removing blade, cleaning the fan completely of dust and dirt and Re- hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook rubber pad, nut bolts and washers etc, complete all as specified and directed by Engr-in-Charge.
Supply and fix of ceiling fans complete with blades, down rods, and accessories, 230 V, 1200 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper winding with brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose all as specified and directed by Engr-in-Charge. Note: Old Ser/ UNSV fans removed from the site are property of Department, will be deposited at E/M yard
Supply and fix of ceiling fans complete with blades, down rods, and accessories, 230 V, 1400 mm sweep 3 blade, white colour,. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated, copper winding with brushless direct current motor (BLDC)(with remote) and connecting up with 3 core x 0.5 sqmm flexible copper conductor cable from ceiling rose all as specified and directed by Engr-in-Charge. Note: Old Ser/ UNSV fans removed from the site are property of Department, will be deposited at E/M yard
Taking down old unserviceable of LT cable of any size complete all as specified and directed by Engr-in-Charge.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 16 sq. mm nominal cross section, 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or strip and overall PVC sheathed, 25 sq mm 4 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc complete all as specified and directed.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanized steel wire or strip and overall PVC sheathed, 10 sq. mm nominal cross section, 2 core in service connections as per IS 7098(Part 1) including connecting on LT OH line / LT panel /DB with suitable lugs, glands, binding wire etc including taking down existing unserviceable service cable of any description complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of GI Pipe and getting out in hard/dense of soil complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including leveling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by Engineer-in-Charge.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- (a) The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. (b) Earthing result should be less than 5 Ohm required.
S&F of Deep Recess - mounting COB LED downlights nucleus Deep Recess 10W made of extruded aluminium housing and high lumen LED as a light source with clear diffuser and separate electronic driver complete all as specified and directed.
Supply and fixing in replacement PVC conduit including fitting such as tee,elbow,bend etc 20mm dia ISI (MMS)grade, incl taking down old unserviceable conduit all as specified and directed.
Supply and fixing in replacement PVC casing Caping tee, elbow,bend etc 20/25 mm size ISI (MMS) incl taking down old unservecable cassing capping all as specified and directed.
ROHIT ENTERPRISES
JAI BALAJI CONSTRUCTIONS
M/S Kumar Contractors
AGRASEN ENTERPRISES
PRAGATI ELECTRICALS AND ELECTRONICS
M/s Sohanil Construction
M/S SHARADA ASOCIATE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .