| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹5.0 L+₹45,628 (10.2%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹5.9 L+₹1.4 L (30.8%)Admitted-Finance | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | IMPLA GENERAL SUPPLIERS L2 | Heaven Electricals L1 | S A S ELECTRIC WORKS L3 |
|---|---|---|---|---|---|---|
| 1.00Work items identified; | ||||||
| 1.01 | Supply,Installation ,testing and commisioning of 9mtr (410 SP-33) long Steel Tubular Poles complete with base plate(350x350x5mm), top cap, Earthing Channel (75x40x6) including digging of pit ,positioning etc, complete in all respect as per Relevant IS. | 12 | Nos. | 17,000 ₹2,04,000 | 16,400 ₹1,96,800 Lowest | 17,500 ₹2,10,000 |
| 2.01 | Supply,laying, stringing, tensioning, binding of 100 Sqmm ACSR Conductor complete in all respects as per Relevant IS. | 2.2 | Km. | 1,10,000 ₹2,42,000 | 78,000 ₹1,71,600 Lowest | 1,28,000 ₹2,81,600 |
| 3.01 | Supply Carraige upto site, fixing of GI V Cross arm & GI F Top with clamps duly fabricated as per site requirement including clamps, GI Nuts & Bolts,washers etc complete in all respects as per Relevant IS. | 252 | Kg | 120 ₹30,240 Lowest | 140 ₹35,280 | 145 ₹36,540 |
| 4.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV polymer composite Pin Insulators 12 kv.5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per Relevant IS. | 36 | No. | 250 ₹9,000 | 170 ₹6,120 Lowest | 270 ₹9,720 |
| 5.01 | Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV polymer composite Disc Insulators 12 kv.45 KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per Relevant IS. | 4 | set | 500 ₹2,000 | 400 ₹1,600 | 375 ₹1,500 Lowest |
| 6.01 | Supply,Carraige upto site,Installation,testing and Commissioning ofgalvanised stay set with 50x8mm stay clamp,guy insulator(2 No.s),anchor plate(200x200x6mm) nuts and bolts ,2 nos turn buckles,1.8 m long,16 mm diameter solid GS stay rod & 7/3.15 mm dia GI starnded wire complete | 2 | No.s | 100 ₹200 Lowest | 1,500 ₹3,000 | 1,800 ₹3,600 |
| 7.01 | Cement bottoming 1:2:4 mix as per Standards 0.5/0.45 cum/pole. | 12 | Job | 200 ₹2,400 Lowest | 1,400 ₹16,800 | 2,000 ₹24,000 |
| 8.01 | Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip.25x3mm | 12 | Job | 100 ₹1,200 Lowest | 500 ₹6,000 | 900 ₹10,800 |
| 9.01 | Painting of Poles with one coat of Red Oxide and two or more coats of alimunium paint to obtain proper finish/uniformity as per standards. | 12 | Job | 100 ₹1,200 Lowest | 200 ₹2,400 | 100 ₹1,200 Lowest |
Tender Value
₹6.5 L
EMD Value
₹12,960
Closing Date
10 Dec 2025, 4:00 pmClosed
Executive Engineer ED Budgam KPDCL
Executive Engineer ED Budgam KPDCL
1.Restoration of HT feeders
2025_PDD_296990_1
86 of 2025-26
Open Tender
Electrical and Maintenance Works
Turn-key
30 days
ED Budgam, KPDCL
AS PER SBD
7 documents required · 7 mandatory
₹500
Executive Engineer ED Budgam KPDCL
₹12,960
15 Dec 2025
1 Dec 2025
11 Dec 2025
1 Dec 2025
10 Dec 2025
1 Dec 2025
1 Dec 2025 - 3 Dec 2025
Amount
Work items identified;
Supply,Installation ,testing and commisioning of 9mtr (410 SP-33) long Steel Tubular Poles complete with base plate(350x350x5mm), top cap, Earthing Channel (75x40x6) including digging of pit ,positioning etc, complete in all respect as per Relevant IS.
Supply,laying, stringing, tensioning, binding of 100 Sqmm ACSR Conductor complete in all respects as per Relevant IS.
Supply Carraige upto site, fixing of GI V Cross arm & GI F Top with clamps duly fabricated as per site requirement including clamps, GI Nuts & Bolts,washers etc complete in all respects as per Relevant IS.
Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV polymer composite Pin Insulators 12 kv.5KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per Relevant IS.
Supply,Carraige upto site,Installation,testing and Commissioning of 11 KV polymer composite Disc Insulators 12 kv.45 KN, Lighting impulse 75 Kv positive and 80 Kv negative, Creepage distance 320mm complete in all respects as per Relevant IS.
Supply,Carraige upto site,Installation,testing and Commissioning ofgalvanised stay set with 50x8mm stay clamp,guy insulator(2 No.s),anchor plate(200x200x6mm) nuts and bolts ,2 nos turn buckles,1.8 m long,16 mm diameter solid GS stay rod & 7/3.15 mm dia GI starnded wire complete
Cement bottoming 1:2:4 mix as per Standards 0.5/0.45 cum/pole.
Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip.25x3mm
Painting of Poles with one coat of Red Oxide and two or more coats of alimunium paint to obtain proper finish/uniformity as per standards.
Supply and fixing of anti climbing device(GI barbed wire with clamps) complete in all respects as per drawings.
Supply and fixing of danger plates with clamps as per drawings.
Supply and fixing of sundry items like aluminium lugs,jumpers,bimding tape,enagement of rescue and restoration boats.
NOTE: 1.The rates quoted by the bidder for all the items shall be inclusive of GST/freight/insurance/storage/installation/testing and any other charges FOR 1.Restoration of Ht line feeder PMA05 Tengan in view of flood damage on Rakh Shalina side of river Jehlum and Pampore side of the river Jehlum. 2.Restoration of HT line feeder PMA05 Tengan on portion of the line submerged in river Jehlum at Bagi Sukur Shah Rakh Shalina. under the jurisdiction of ED Budgam, KPDCL.
IMPLA GENERAL SUPPLIERS (BID ID -2665382)
S A S ELECTRIC WORKS (BID ID -2657824)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.47 MB
Tendernotice_2.pdf
PDF • 1.84 MB
BOQ_962440.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .