Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.2 LAccepted-AOC D 2 D 3 SIDCO INDUSTRIAL ESTATE METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | L1 | Accepted-AOC L1 | |
| 2 | L2₹50.3 L+₹2.0 L (4.13%)Rejected-AOC 13 1 SIDCO INDUSTRIAL ESTATE METTUR DAM 636 402 | METTUR DAM | SALEM | TAMIL NADU | 636402 | L2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹41,900
Closing Date
25 Jun 2024, 2:00 pmClosed
CE/MTPS-II
O/o CE/MTPS-II
Boiler 2nd pass Cleaning of Boiler tubes thickness survey Surface preparation metal Filing by arc welding in the eroded portions of the boiler tubes Renewal of defective boiler tubes bends and Fixing Strengthening of shrouding plates if required an
2024_EB_453521_1
OT 10
Open Tender
Maintenance Works
Works
28 days
SE/M-I/MTPS-II
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹41,900
Yes
13 Aug 2024
11 Jun 2024
26 Jun 2024
11 Jun 2024
25 Jun 2024
11 Jun 2024
Amount
Cleaning of tubes by buffing wheel to facilitate tube thickness survey at boiler II pass and other areas wherever required.
Providing the assistance for Boiler tube thickness survey in the boiler pressure parts.
Conducting tube thickness survey in boiler pressure parts including the hire charges for ultrasonic thickness gauge (Where thickness survey cannot to be taken, erosion should be checked by visually and physically)
Cleaning of tubes by buffing wheel to facilitate tube thickness survey at final reheater & Primary reheater from 63 mtr to 73 mtr elevation and other areas wherever required.
Providing the assistance for Boiler tube thickness survey final reheater & Primary reheater from 63 mtr to 73 mtr elevation in the boiler.
Conducting tube thickness survey final reheater & Primary reheater from 63 mtr to 73 mtr elevation in the boiler including the hire charges for ultrasonic thickness gauge. (Where thickness survey cannot to be taken, erosion should be checked by visually and physically)
Checking / Replacing / reconditioning the Shrouding plates with fixing clamps by welding at both sides of the tubes in the 2nd pass area, which includes LTRH,LTSH and Economizers.
Arrangement of platform and scaffolding materials and erection of the same wherever required in the boiler area for tube rectification work / hydro test and transporting the scaffolding materials.
Renewal of defective boiler tubes of size 44.5mm OD inclusive of transportation, cutting of defective tubes, edge/spool preparation, welding with IBR welder, cost of Argon gas, cutting gas, all consumables, T&P's, hire charges for welding generator, TIG set and etc.
Cutting the worn out tubes of tube dia above 44.5mm, & up to 63.5X5.2mm edge preparation of the new & existing tubes, positioning the tubes with proper alignment, TIG and ARC welding the joint with IBR welder, cost of Argon gas, cutting gas, all consumables, T&P's, hire charges for welding generator, TIG set and etc.
Surface preparation & metal Filing by arc welding to the required thickness in the eroded portions of the boiler tubes by the IBR welder including the cost of Welding electrodes & hire charges for welding generator & other T&P's etc. Welding of size up to 150x25-mm
Lowering the coils for cutting, grinding and welding with providing proper chain block support and lifting the same coils after completion of works including the charges like consumables, T&P's and etc.
Providing Platform arrangement at 3 levels entire length of width 20m (60.0m, 64.0m and 67.0m) for thickness survey, renewal of defective boiler tubes, strengthening / Reconditioning the welding with clamp and to reinstate the dislodged shrouding again in Final reheater tubes with horizontal bend in 35 degree slope of goose neck water wall from 64mtr level to 57mtr level, by following highest safety standards including charges for transportation and leading lifting of scaffolding materials to boiler required area, hire charges for T&P's etc.
Restoring / Reconditioning of shrouding of various lengths of straight / bend in final super heater & Final reheater in the interpass slope area and retrieving the fallen shrouding plate, including charges for consumables, SS welding rods, hire charges for T&P's etc.
Fin welding including the cost of Welding electrode, all consumables, hire charges for welding generator & other T&P's etc.
Removal of insulation double layer (60mm + 60mm = 120mm thick) from Boiler elevation and refixing after completion of rectification works.
KUMAR ERECTORS (BID ID -1068315)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .