| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC | ₹1.3 Cr | L1 | Accepted-AOC Being Lowest and Reasonable |
| 2 | L2₹1.5 Cr+₹14.8 L (11.0%)Rejected-Finance | ₹1.5 Cr+₹14.8 L (11.0%) | L2 | Rejected-Finance Other than Lowest |
| 3 | L3₹1.5 Cr+₹18.0 L (13.4%)Rejected-Finance 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹1.5 Cr+₹18.0 L (13.4%) | L3 | Rejected-Finance Other than Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹2.6 L
Closing Date
7 Jul 2020, 6:00 pmClosed
CHIEF ENGINEER R AND D DELHI
HQ CHIEF ENGINEER R AND D PROBYN ROAD DELHI 54
RENOVATION TO BUILDING NO P2 OF DIPAS DELHI UNDER GE I R AND D DELHI
2020_MES_311419_1
CE R and D/DLI-16/2019-20
Open Tender
Civil Works
Item Rate
547 days
DELHI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Yes
₹2.6 L
Yes
28 Sept 2020
22 May 2020
9 Jul 2020
22 May 2020
7 Jul 2020
23 Jun 2020
Amount
B/R Portion Complete removal of existing treatment from walls, fins, chajja etc by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots including removing waste material/ debris outside MoD land complete all as specified and directed.
M&L for two coats of acrylic exterior emulsion (weather proof) on old external cement plastered/concrete vertical surfaces over 3mm thick wall care putty (in two coat first 2mm thick and another 1mm thick) complete all as specified and directed.
M&L for applying two coats of OBD over one coat of primer on old decorated plastered walls/vertical surfaces complete all as specified directed.
M&L for applying two coats of OBD over 3 mm thick wall care putty (in two coat,s first 2mm thick and another 1mm thick) on new plaster wall/vertical surfaces complete all as specified and directed.
M&L for applying one coat of white washing on ceiling, plastered surfaces after preparation of old decorated surfaces by brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and directed.
M&L for applying one coat of oil bound distemper on ceiling after preparation of old decorated surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots complete all as specified and directed.
Dismantling of wall and ceiling board (fibre pulp and insulation etc) or insulation boards/slabs/blankets any thickness including cover fillets, aluminium frame work, hangers/rods complete all as specified and as directed.
S&F powder coated aluminium snap grid of size 605 x 605 mm frame work for false ceiling for resting 10mm thick board complete all as specified and directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified
M&L for providing Gypsum Board 12mm thick in ceiling fixed with screw as per manufacturers instructions complete all as specified.
M&L for 600 x 600 x 10 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre fixed in frame work of ceilings complete all as per manufacturer's instructions and as specified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish including tiles out side MoD land complete all as specified and directed.
S&F 1st quality coloured non skid ceramic coloured tiles of grade 'B' II (a)/ II (b) and of abrasion resistance P.E. -III or above 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set & jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including20mm thick screed bed in CM (1:6) complete all as specified and directed.
M&L for light shade coloured vitrified ceramic tiles 8 to 9mm thick of size 600x600mm , 1st quality colour of grade 'B' II (a ) / II (b) and of abrasion resistance P.E. -III or above in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 20mm thick cement screed bed in CM (1:6) complete all as specified and directed.
M&L for providing glazed ceramic coloured designer tiles supper glossy 1st quality colour of grade 'B' in vertical surface such as skirting/dado of size 450x300mmx7mm to 8mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles over and including 10mm thick cement rendering in CM 1:4 complete all as specified and directed.
M&L for chequered cement concrete tile size 30 cm x 30 cm x 20 mm thick moulded in PVC frame/mould, set, jointed and pointed in neat cement slurry with grey cement and pigment laid in floors over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F in repairs pillar taps fancy type, CP brass with capstan heads, scewed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nut, screwed for iron pipes or brass ferrule of 15mm bore fixed in position complete all as specified and directed.
S&F in repairs 15mm bore laboratory pillar taps fancy type, with multi exits, CP brass with capstan heads, scewed down high pressure, with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nut, screwed for iron pipes or brass ferrule of 15mm bore fixed in position complete all as specified.
S&F in repairs chromium plated brass bib taps short/long body, fancy type with crutch or butterfly handle, screwed down for iron pipe, or brass ferrule of 15mm bore fixed in position complete all as specified and directed.
S&F in repairs angle/stop valve CP brass , fancy type, chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions or brass ferrule of 15mm bore fixed in position complete all as specified and directed.
S&F in repair vitreous china wash basin white flat back of size 550x 400 mm (excluding taps), including waste, chain , plug and C.I. or angle iron brackets complete all as specified and directed.
S&F in repairs of 1mm thick stainless steel sink with draining board for kitchen or laboratory with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cast iron or mild steel angle iron cantilever brackets and connecting union to pipe over all size of sink 915mm x 460mm and bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs Stainless steel sink, 1.00mm thick for kitchen or laboratory with plug waste pipe, washers including cantilever cast iron brackets connecting union to pipe etc. overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs UPVC 32mm bore waste pipe for W.H.B complete all as specified and directed.
S&F in repairs 10 litre capacity coloured PVC valveless syphonic action type flushing cistern low level with inlet, ball valve float, including bracket fixed in position complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to wall with m.s. clamps complete all as specified and directed.
S&F in repairs PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
S&F in repairs PVC connection 15mm size 450mm long with PTMT nuts complete all as specified and directed.
S&F in repairs doom type PTMT grating 125 mm dia with waste hole fixed on floor / nahani trap fixed with cement mortar complete all as directed.
S&F in repairs CP brass bottle trap 32 mm bore including joining to waste fitting and pipe complete all as specified and directed.
S&F in repairs vitreous china urinal half stall olymous star white including waste pipe complete all as specified and directed.
Taking up or down steel water tubing and connections, from any position including cutting of brick wall, removal of 15mm bore pipe from existing position and making good disturbed surface with existing complete all as specified and directed.
All as per item no 33 here -in- before (above) but 20 mm bore pipe.
S&F GI steel tubing medium grade galvanised 15mm bore with all accessories/ fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed. Note : Cutting chases for concealed pipes and fittings etc wherever required and making good, disturbed surfaces shall be measured and paid separately under relevant items of BOQ.
S&F GI steel tubing medium grade galvanised 20mm bore with all accessories/ fittings and fixed to walls and ceilings or laid in floors complete all as specified and directed.
S&F in repairs jet spray 15mm bore health faucet suitable for EWC including PVC chord and brass nozzle, fixed to pipe complete all as specified and directed.
S&F in repairs 9mm thick plywood, grade BWR type BB fixed with screws to timber/aluminium/steel frame complete all as specified and directed.
S & F in repairs vitreous china squating pan 'Orissa' Pattern, size 580x440mm white, with integral foot rests ( excluding flushing cistern and flush pipe ) including removing waste material/ debris to out side MoD land complete all as specified and directed.
S&F in repairs vitreous chinaware wash down water closet pan pedestal pattern white, (excluding fixing bolts) including jointing to flushing cistern and flush pipe antisyphonage pipe etc and including plastic water closet seat cover white closed pattern with flat bottom end cover and mild steel chromium plated hinging device complete all as specified and directed.
S&F in repairs brass chromium plated Tubular Towel rail 20mm dia, wall thickness not less than 1mm, D type, 60cm long between flanges of brass chromium plated and including wooden/plastic cleats complete all as specified and directed.
Taking up or down 75/80mm bore cast iron pipe (including all fittings), with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified & directed.
All as per Ser item No 42 here-in-before but 100mm bore.
S&F 75mm bore Cast iron sand cast pipes, soil, waste and vent pipes, in any length with or without ears with cement joints, laid in trenches or in floors complete all as specified & directed. Note :- Excavation and earth work will be measured & paid separately.
All as per Ser item No. 44 here-in-before but 100mm bore.
S&F 75mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed.
All as per Ser item No 46 above but 100 mm bore.
S&F in repairs 100 mm bore cast iron 'P' or 'S' trap complete all as specified and directed.
S & F in repair for 75mm dia of outlet, cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B 0 (using 12.5mm graded stone aggregates) complete all as specified and directed.
Cutting chases, pinning in brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills etc and cutting chases for concealed water tubing or concealed conduit wiring etc and making good cutting n. exc 10cm in girth including removing waste material/ debris out side MoD land complete all as specified & directed.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for including removing waste material/ debris out side MoD land complete all as specified & directed.
M&L for water proofing treatment to sunken slab complete all as specified and directed comprises the following operations/stages :- (a) Rendering 15mm thck in CM 1:4 mixed with water proofing compound @ 3% by weight of cement. (b) After drying of plastered surface suitable primer such as multiplas primer/ multiplas / cold sticker/ multiplas blown bitumen VG-10 shall be applied/coated on the plastered surfaces. (c) MULTIPLAS @3 kg/Sqm shall be unrolled over the coated surface (with overlap of 10cm) and bonded completely to the primed surface. and overlap sealed by the torch flame. (d) Topping with PLASFAL @ 2 kg /Sqm. A layer of blown bitumen of VG-10 is applied @ 1.20kg/Sqm on MULTIPLAS. Plasfal membrane shall then bonded on top of MULTIPLAS. Note (i) The above water proofing treatment shall be carried out by authorised approved applicator/agency as approved by GE. (ii) Concrete filling, if required shall be measured & paid separately. (iii) The unit rate also includes the cost of W.P.C. required while executing work. (iv) Minimum 10 years written guarantee period for any leakage, seepage in sunken portion is to be rendered by the contractor/firm.
M&L for providing cement concrete type D2 1:4:8 (using 40mm graded crushed stone aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
M&L for providing cement concrete type B2 1:2:4 (using 40mm graded crushed stone aggregate) in foundations, filling and mass-concrete complete all as specified and directed.
Taking down cement plaster on brick walls, raking out joints hacking for key, scrubbing down with water etc including removing waste material/ debris to out side MoD land complete all as specified.
M&L for rendering 15 mm thick in CM(1:6) on brickwork or concrete surfaces, finished even and smooth without using extra cement complete all as specified.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F in repairs PVC sheets, 2.00mm thick laminated plain coloured, marbled mosaic or mottled finish, laid with approved rubber based adhesive in floors as per manufacturer's instructions complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded and pointed in any mortor including removing waste material/ debris to out side MoD land complete all as specified and directed.
M&L for 16mm to 18mm thick granite ( of any type ) work (table rubbed and polished) in steps, jambs pillars, window, cill cooking platforms, shelves and like over and including 20 mm thick screed bed in cement mortar ( 1:4) and pointing in white cement ( 1:2) using marble dust with admixture of pigment to match with shade of granite slab complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and directed.
Taking down Chowkhats or frames or partitions (Aluminium / Wooden / steel ) not exc. 1.5 sq. m each with shutters (without taking off shutters or insertion of partition from the frames) complete all as specified and directed.
Taking down Chowkhats or frames or partitions(Aluminium / Wooden/ steel) exc. 1.5 sq. m but n.exc 4 sqm each (without taking off shutters or insertion of partition from the frames) complete all as specified and directed.
Taking down Chowkhats or frames or partitions (Aluminium / Wooden/ steel ) exc. 4 sq. m but n.exc 6.5 sqm each with shutters (without taking off shutters or insertion of partitions from the frames) complete all as specified and directed.
S&F aluminium section duly powder coated of any colour not less than 50micron thick for frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F aluminium section duly powder coated of any colour not less than 50micron thick for swing door shutters partly panelled and partly glazed comprising top rail 85.00x44.45x2.70mm , bottom rail 150x44.45x2.20 mm , lock rail 150x44.45x3.00 mm and styles 47.62x44.45x1.62mm and including joining cleats, aluminium snap beading , rubber gasket glazing clips and two nos disc type handle and one nos aluminium tower bolt 200mm long on one side and one number 6 lever dead lock of brass with for each leaf fixed in position complete all as specified and directed . Note: Glazing and prelaminated particle board insertion shall be measured & paid separately under relevant item of BoQ.
S & F double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed in position complete all as specified and directed.
S&F aluminium section duly powder coated of any colour not less than 50micron thick for windows/ cupboard shutters (fixed/ openable) frame made out of aluminium frame of section 63.50mmx 38.10mm x1.60mm thick and shutter fixed or open able horizontal and vertical members of aluminium section 47.50x44.45x1.60mm thick with aluminium beading rubber gasket, aluminium fittings such as 2 Nos hinges 75mm long, 02 Nos tower bolts 150mm long, 100mm stay rod and one handles 125mm , etc complete all as specified and directed. Note: Glazing and prelaminated particle board insertion shall be measured & paid separately under relevant item of BoQ.
S&F aluminium section duly powder coated of any colour not less than 50 micron thick for partly glazed/ partly panelled partitions and fixed glazing frame made out of aluminium frame of section 63.50mmx 38.10mm x1.60mm including necessary joining cleats, glazing clips, rubber packing, aluminium snap beading screws etc frame work fixed to walls, floor and ceiling with rawl plug wherever required complete all as specified and directed. Note: Glazing and prelaminated particle board insertion shall be measured & paid separately under relevant item of BoQ.
S&F aluminium grill 6 x 4.5 mm thick section 10cm centre to centre spacing duly powder coated of any colour not less than 50micron thick with necessary U-channel alround fixed in window frame/opening with screws complete all as specified and directed.
S&F 4.8 mm thick sheet glass ordinary quality, area exc 0.5 sqm in each pane and fixing by means of glazing pins and rubber beading and glazing filling materials in panels of aluminium doors / windows /partitions etc complete all as specified and directed.
All as per Srl. item No. 72 above but n exc 0.5 sqm in each pane.
S&F Solar control film 25 micron reflective type (greater sun control or equivalent) to stick on glass as per manufacturer's instructions complete all as directed.
S&F 9mm thick prelaminated particle board interior grade, prelaminated both side with decorative choice lamination both sides, fixed with screws to timber frame work or aluminium framework complete all as specified and directed.
S&F in repairs aluminium door closer (die cast body) hydraulically regulated, designation No. 2, universal type, suitable for door shutters of 701 to 850 mm in width and of weight between 36 to 60kg and fixed in position complete all as specified and directed.
Repair only aluminium door shutter by taking down from frame, opening out joints, glass or particle board, replacing the corner piece & defective members jointing again refixing the glass pane/particle board including rubber gasket etc complete all as specified and directed. Note : Aluminium section if required shall be measured & paid seperately under respective item of BoQ.
S&F in repairs dead lock, verticle type of brass complete size 100mm and 4 levers and taking down existing mortice lock complete all as specified and directed. Note: The rates include the necessary provision of escutcheon plates and two keys.
S&F in repair chromium plated urinal spreeder suitable for fixing 15 mm dia bore pipe complete all as specified and directed
Internal Electrification Taking down carefully point wiring copper/aluminium (light, fan, socket, and power) complete (fittings such as switches ceiling roses, pendent regtulators sockets sunken boxes etc and removing materials from site and making good the disturbed surfaces with existing complete all as specified and as directed.
M&L for point wring for one light/ceiling fan controlled by one switch 5/6 A one way with 1.5 sqmm multi stranded (nominal area) PVC insulated and PVC unsheathed copper conductor cable FRLSH conforming to IS-694 in and including concealed rigid non metallic PVC conduit of 20mm external dia ISI marked, including 2mm thick new G.I. sheet sunken boxes,modular frame and cover plate for fixing of modular switches as per required point in that board or independent including PVC insulated unsheathed 1.5 sqmm multi standared copper conductor cable FRLSH connected to common earth dolly complete including cutting,chasing the surface and then making good the same in CM 1:3 complete all as specified and directed.
All as per srl item No 81 here-in-before but one socket point controlled by one way switches on same board.
All as per srl item No 81 here-in-before but one 3 pin 5/6 Amps socket outlet point on indipendent board.
All as per srl item No. 81 here-in-before but with 2.5 sqmm FRLSH wire and earth wire of 2.5 sqmm FRLSH for 3 Pin 16 Amp socket outlet.
All as per srl item No. 81 here-in-before but with 4 sqmm FRLSH wire and earth wire of 4 sqmm FRLSH for 3 Pin 16 Amp socket outlet on independent board.
Supply and fixing in repairs of rigid non metallic PVC conduit, 25 mm dia (external) inclusive of all fittings such as tees, bends, elbow, reducers, with modular sheet cover, bell mouth tube ends etc and all fixing accessories such as couples, bolts, nuts, saddles, pipe hooks etc complete all as specified and directed.
Supply and fixing modular switch single pole one way 6 Amps 1 module complete all as specified and directed
Supply and fixing modular switch single pole one way 16 Amps 1 module complete all as specified and directed
Supply and fixing modular socket 6 amp-5 pin combined 2 module complete all as specified and directed.
Supply and fixing modular socket 6 A/16 amp-5 pin combined 2 module all as specified and directed.
Supply and fixing ceiling rose of size55 x 25mm, 3 terminal /PVC/polycarbonate,isolated body complete all as specified and directed.
Supply and fixing electronic modular fan regulator, step type, two module 120 watt 230 volt and making all necessary connections complete all as specified and directed.
S&F in repairs earth continuty conductor or main earthing lead 25X4 mm galvanised strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe fixed to poles or any other indicated situation for loop earthing etc complete all as specified and as directed. Note: Excavation and earth work in any type of soil in case required shall be measusred & paid separately.
Supply and in renewal of sheet metal enclosure, single pole and neutral with two pin and earth plug and socket complete with one single pole MCB SP, C Curve type of capacity 20 Amp,240V, 10 kA complete all as specified and directed.
Supply and fixing, in renewal of triple pole and earth enclosure with three pin and earth plug with socket complete (Industrial type DB) with and including one MCB TP, C Curve type of capacity 32 Amp, 10 kA , 415 volt complete all as specified and directed.
M&L in renewal wiring for circuit/submain wiring along with earth wire with 2 x 4.00 sqmm + 1 x 4 sqm earth wire of FR LSH PVC insulated copper conductor single core cable in and including concealed rigid non metallic PVC conduit of 25mm external dia including all accessories complete all as specified and as directed.
M&L in renewal wiring for circuit/submain wiring along with earth wire with 2 x 6 Sq mm +1 x 6 Sq mm earth wire of FRLSH PVC insulated copper conductor single core cable in and including concealed rigid non metallic PVC conduit of 25mm external dia including all accessories complete all as specified and as directed .
M&L in renewal wiring for circuit/submain wiring along with earth wire with 2x10 sqmm+1x10 sq mm earth wire of FRLSH PVC insulated copper conductor single core cable in and including concealed rigid non metallic PVC conduit of 25mm external dia including all accessories complete all as specified and as directed
M&L in renewal wiring for circuit/submain wiring along with earth wire with 4x4.00 sqmm+2x4 sq mm earth wire of FRLSH PVC insulated copper conductor single core cable in and including concealed rigid non metallic PVC conduit of suitable all as accessories complete all as specified and as directed.
M&L in renewal wiring for circuit/submain wiring along with earth wire with 4x10.00 sqmm+2x10sq mm earth wire of FRLSH PVC insulated copper conductor single core cable in and including concealed rigid non metallic PVC conduit of suitable dia including all accessories complete all as required or all as specified and as directed by Engineer-in-charge.
M&L in renewal wiring for circuit/submain wiring along with earth wire with 4x 16 sqmm+ 2x 16sq mm earth wire of FRLSH PVC insulated copper conductor single core cable in and including conduit pipe 25 mm external dia medium grade including all accessories completeall as required or all as specified and as directed by Engineer-in-charge.
M&L in renewal wiring for circuit/submain wiring along with earth wire with 4x 70 sqmm+ 1 x 70 Sq mm earth wire of HRFR PVC insulated copper conductor single core cable in and including conduit pipe 40 mm external dia medium grade for each length of cable including all accessories completeall as required or all as specified and as directed by Engineer-in-charge.
M&L in renewal wiring for circuit/submain wiring along with earth wire with 4x 50 sqmm+ 1x 50 sq mm earth wire of HRFR PVC insulated copper conductor single core cable in and including conduit pipe 40 mm external dia medium grade for each length of cable including all accessories complete all as required or all as specified and as directed by Engineer-in-charge.
S&F in repair light fitting 2x2,36 W recess mounted pressure die cast aluminium powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver and making all electric connection with 3 core PVC insulated PVC sheathed. Copper conductor flexible cable 1.5 Sqmm including taking down old existing one luminare complete all as specified and directed. Make C&S Cat Part No. LTCRP36WLED2X2 or equivalent of Bajaj/ Philips.
Supply and fixing in repair of LED tube light along with fixtures 4 feet, 20 Watt retrofit T8 Polycarbonate tube and making all electric each connections with three core PVC insulated, PVC sheathed copper conductor flexible cable 1.5 sqmm including taking down old unserviceable light fitting etc complete all as specified and directed. Make: C&S Cat Part No. LTIV00120LEDWD or equivalent of Bajaj/ Philips.
S&F in repair LED flood light fitting with IP 65 protection, pressure die cast aluminium housing , complete with all accessories of 70W. Make: Cat Part No LTEF70WHPLED of C&S or equivalent in Bajaj/ Philips.
Supply and fixing of down rod of sufficient size /length with and including hanging accessories etc and making all electric connections of ceiling fan complete all as specified and directed.
Taking down Ceiling/ exhaust/ Wall mounted fan of any size complete, sealing cable end, dismantling blades and removing fan and blade to store and refixing it on same and other locations after repair, greasing and applying synthetic enamel paint complete all as directed by Engr-in-charge.
Supply and fixing of Modular blank plate 01 Module size complete all as specified and directed .
Material and Labour in repair for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below Normal ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate, and up to 15 cm above the same. GI plate connected with galvanised earth lead wire 4.0mm dia by means of GI nuts, bolts and washers of galvanised iron all as shown in electrical plate no.3 connecting to earth test point all as specified or indicated including earth work, testing on completion with following:- (a) Test point GI wire 4mm dia . (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embedded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 40 mm thick with 8 mm dia deformed bars @100 c/c both ways with 02 Nos MS handles of 12 mm dia suitable for carrying of pit cover. (d) Angle iron frame made out of 40x40x4 mm for PCC pit for holding the pit cover.
S&F in repairs 4 mm dia GI wire as earth continuity conductor or main earth strip fixed to wall on batten or recess or chase or burried in ground or any other indicated situation for loop earthing etc complete all as specified and directed. Note: Necessary excavation and earth work in in case required is in to be measured and paid separately under respective item.
Supply and fixing in repair of MCCB Incomer type distribution board (load line) double door VTPN made out of CRCA steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 4 way, 415 volts with bus bar rating 250 Amps, dust and vermin proof and IP 43 - IK 09 with metal door suitable for accomodate/ incorporation of MCCB as incomer, including grouting in the wall, cutting & chasing etc complete and including taking down existing one all as specified.
Supply and fixing in repairs of MCCB Incomer type distribution board (load line) double door VTPN made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 8way, 415 volts with bus bar rating 250 Amps, dust and vermin proof and IP 43 - IK 09 with metal door suitable for accomodate/ incorporation of MCCB as incomer, including grouting in the wall, cutting & chasing etc complete and including taking down existing one all as specified.
Supply and fixing in repairs of MCB DB sheet metal enclosur double door TPN 4 way with 415V rated busbar complete all as directed.
Supply and fixing in repairs of MCB DB sheet metal enclosur double door SPN 8 way with 240 V rated busbar complete all as directed.
Supply and fixing in repairs of MCCB, 415 volts, four pole of capacity 125 Amps, 36 KA, ICS = 100% ICU, with Thermal - Magnetic Release, including spreader terminals / thimble of suitable size and making connections complete all as specified. Make : HAVELLS- IHLANECF0125/ or equivalent Hager / L&T
Supply and fixing in repairs MCB, C Curve type suitable for 415 volts AC supply, TPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 63 Amps capacity complete all as specified and directed.
Supply and fixing in repairs MCB, C Curve type suitable for 415 volts AC supply, TP with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 Amps capacity complete all as specified and directed.
Supply and fixing in repairs MCB, C Curve type suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 Amps capacity complete all as specified and directed.
Supply and fixing in repairs MCB, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 40 Amps capacity complete all as specified and directed.
S&F in repairs telephone socket jack with shutter RJ-11, complete all as specified & directed.
Supply and fixing dual ceiling mounted switch sensor movement detection 360 degree with option of setting vacancy & occupancy mode (Push button override or moble configuration) automatic terminal connection. PIR & US dual tech coverage 80 Sqm with diameter 11m having time delay setting from 0 to 60min, suitable for 100w -250w LED connected load including necessary wiring with 1.5 Sqm copper cable single core complete & testing after installation. (Cat No. 048806 of Legrand or equivalent make of Hager/L&T)
Supply and fixing digital programming set suitable to adjust the setting of motion sensor to the he nearest one decimal places suitable for setting of each detector complete (Cat No 088230 of Legrand or equivalent in Hager/L&T)
S&F DLP U PVC trunking system Plastic adoptable type 150x50mm with two compartment duly covered installed with suitable support joints including all accessories complete all as specified and as directed.( Make :Legrand/AKG/BEC/ L & T)
Fire Alarm System Taking dowm Heat/smoke fire detctor,extended existing from wiring, and all as directed.
Supply, Installation, testing and commissioning of UL listed Microprocessor based intelligent and modular panel, 100% electronically addressable system where field device addressing is done automatic in lieu of manual, complete touch screen system with peer to peer networking of 126 network nodes, minimum loop capacity of 200 devices per loop, built in battery & charger that can support backup upto 24hours idle condition and 30 minutes during alarm condition, integral thermal printer,96 Zonal LEDs on board, capacity to have upto 250 logic zones created, LCD screen of LED technology,4 NAC circuits, 3 programmable relays, dedicated Alarm relay, Event history on 9999 logs, option to load Logo on the main screen, view live analog level of field devices on the panel screen, option to download these events log and analog level report from panel, 3 detector sensitivity levels, option to change the operating temperature of heat detectors from panel, Alarm verification option, T1/T2 timer option, field outputs modules programmable with 3 stage program options, have open path programming software, capacity to communicate loop mount repeater panels, optional NAC power supply units that are loop mountable and 100% supervised from main panel ULCF30002GNC. Make : Note :- (i) The above mentioned fire alram shall be in Metal enclosure including built in Printer & Network Card.The FACP/network of FACP shall be able to accommodate the given number of devices as per BoQ and shall have 20% spare capacity to accommodate future. (ii) The rate also includes in this items for necessary taking down old existing panel.
Supply, Installation, testing and commissioning fire repeater panel of UL Listed repeater panel with mute, evacuate,silence & reset options on panel, with inbuilt battery ULCF3000PRG and including taking down old existing unserviceable fire repeater panel complete all as specified and as directed.
Supply, Installation, testing and commissioning of UL Listed Addressable 2 wire Multi criteria detector with built-in short circuit isolator, 100% soft addressing, single LED that covers 360 Deg lightpipetechnology with intensity that can handle upto 5000 Lux, Discreet design for incorporation into Common mounting base, Drift compensation, Removable detector chamber, Chamber monitoring by panel, option to connect remote indicator and detector with inbuilt isolator ULCAPT340+UCAB300 complete all as specified and as directed.
Supply, Installation, testing and commissioning of UL Listed Addressable 2 wire Multi Mode heat Detector ( Fixed + ROR) with built-in short circuit isolator, 100% soft addressing, single LED that covers 360Deg lightpipe technology with intensity that can handle upto 5000 Lux, Discreet design for incorporation into any décor, Common mounting base, Drift compensation, Removable detector chamber, Chamber monitoring by panel, option to connect remote indicator and detector with inbuilt isolator ULCAH330+UCAB300. Make : COOPER / EATON / MENVIE complete all as specified and as directed.
Supply, Installation, testing and commissioning of UL Listed Addressable 2 wire Dual action Pull Station with built in short circuit isolator, 100% soft addressed from panel, Wall mounting, resettable key option,Corrosion resistant gold plated SPST contacts,, high-gloss red enameland including taking down old existing one complete all as specified and directed.
Supply, Installation, testing and commissioning UL listed Wall mount Addressable sounder with strobe, minimum 90dB with complete accessories HSR, including taking down old existing one complete all as specified and directed.
Supply, Installation, testing and commissioning including taking down of UL Listed Addressable 2 Wire monitor module, 100% soft addressed from panel, integral short circuit isolators, application to acheive -pressure switch, flow switches, fire pump contacts ULMCIM. Make : COOPER / EATON / MENVIER
Supply, Installation, testing and commissioning including taking down of UL Listed Addressable 2 Wire Control module, 100% soft addressed, integral short circuit isolators, applications to acheive shutting down AHU’s, magnetic fire door holders. Elevator recall, fire damper, pressurization fan ULMCOM. Make : COOPER / EATON /MENVIER
Supplying, Installing, testing & commissioning including taking down of Self-contained IP65 emergency luminaire with 12x0.25W LEDs, suitable for use as an emergency luminaire or escape exit sign by application of exit sign legend, with built in NiCd Battery with charger. Make : Cooper, Heinrich, Bosch
External Water Supply Supply and fixing in repairs 80 mm bore GI tubing medium grade screwed and socket joint complete with all fittings such as bend socket, tees,elbow, union barrel, nipple plug etc laid in floors, trenches walls and ceiling with necessary GI clamps etc complete all as specified and directed. Note:- Excavation and earth work shall be measured and paid separately.
All as per item No 136 above but 50mm bore
All as per item No 136 above but 40mm bore
All as per item No 136 above but 25mm bore
M&L for repair / renewal of cast iron 80mm Dia sluice valve both ends flanged and drilled, conforming to, PN -1.0 complete with hand wheel ,cap,gland ,gland packing, thrust plate cover ,spindle, nut valve , face rings with fitting as per existing flanged including nut bolt ,gasket complete all as directed
Supply and fixing in repairs Gun metal gate valve heavy duty with iron wheel head, confirming to IS-778 & 1984 Class I screwed both ends as per IS-554 parallel for iron pipe of size 50mm, bore complete all as specified and directed.
All as per item No 141 above but size 25 mm bore.
M&L for construction valve camber of size 1200x1200x900mm (internal dimension) using fly ash bricks having compressor strength not less than 75 kg/ sq cm), brick masonery built in cm 1:6, 10cm thick internal & external plaster in CM 1:4 thick ms sheet cover welded 40x40x3mm angle iron frame fixed in coping pcc 1:2:4 type B1 ( using 20mm graded stone aggregate with 4 nos, 40X5 mm 150mm long flat iron hold fasts ) with locking arrangement and 2 nos 150mm long 10 mm dia M.S handle, 2 nos.medium weight cold rolled MS, butt hinges150mm long, painting with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer on all exposed steel surfaces and applying two coat of hot tar on embedded steel surfaces, including necessary excavation and earth work in any type of soil and removal of surplus soil outside MOD land complete all as specified and directed.
All as per item No 143 above but 900x900x600mm.
External Electric Supply. Supply and fixing passing through ducting , laid in tranches (and connected to existing main MCCB ) XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured LT under ground cable heavy duty 1100 volts grade with multi stranded aluminium conductor confirming to IS -7098, including cable gland, cables lugs for termination including taking down , cross sectional area 630 Sq mm 3.5 core. complete all as specified & directed at site.
Supply and fixing passing through ducting /tranches as site requirment (and connected to existing main MCCB ) XLPE insulated screened PVC bedded, galvanized steel strip armoured LT under ground cable heavy duty 1100 volts grade with multi stranded aluminium conductor confirming to IS -7098, including cable gland, cables lugs for including taking down , cross sectional area 120 Sq mm 3.5 core .complete all as specified & directed at site.
Supply and fixing passing through ducting /tranches as site requirment (and connected to existing main MCCB ) XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured LT under ground cable heavy duty 1100 volts grade with multi stranded aluminium conductor confirming to IS -7098, including cable gland, cables lugs for, cross sectional area 95 Sq mm 3.5 core.complete all as specified & directed at site. NOTE: for ser item no. 145 to 147 Excavation, earth work,brick protection and sand cushion shall be measured and paid separately.
Supply and fixing in repairs Offload Change Overswitch 400 Amp ,415V AC , 50Hz - AC21 (Side Handle) in sheet enclosure complete all as specified and directed.
Supply and fixing Offload Change Overswitch 200 Amp ,415V AC , 50Hz - AC21 (Side Handle) in sheet enclosure complete all as specified and directed.
M&L for bricks having compressive strength not less than 75 kg/sqcm laid dry for protection of cables laid in trenches complete all as specified and directed.
Excavation in tranches n. exc. 1.5m wide & n. exc 1.5 m deep in depth for foundation for taking up or down or laying of cables, water pipes etc. and getting out in soft/loose soil complete all as specified & directed.
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and as directed.
Removing excavated materials, soil, exceeding 1.5km but not exceeding 5 km and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified & directed.
M&L for river screened sand filling for cushion of underground cable with layer of sand 8 cm deep before laying and 15 cm deep after laying of cables complete all as specified & directed. Note : Punned down thickness will be considered for payment of sand cushion of cables
S & F 100mm dia sand cast iron soil, waste & vent pipes in any length with or without ears jointed with cement, fixed to walls complete all as specified and directed.
S & F 75mm dia sand cast iron soil, waste and vent pipes in any length with or with out ears jointed with cement, fixed to wall complete all as specifed and directed.
AMIT ASSOCIATES
Leo Network power systems
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .