| 1 | Accepted-Technical NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Accepted-Technical DOCUMENTS ARE IN ORDER |
| 2 | Accepted-Technical | Accepted-Technical DOCUMENTS ARE IN ORDER |
| 3 | Accepted-Technical | Accepted-Technical DOCUMENTS ARE IN ORDER |
| 4 | Accepted-Technical 6 51 OLD POST OFFICE LANE UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | Accepted-Technical DOCUMENTS ARE IN ORDER |
| 5 | Accepted-Technical | Accepted-Technical DOCUMENTS ARE IN ORDER |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
31 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 881 EWS, C/O 56 APO
GE 881 EWS, C/O 56 APO
SPL REPAIR TO BLDG NOs P-34 P-89 AND SPL REPAIR TO MAIN FIRE STATION BUILDING NO P-90 IN AOR OF AGE B/R-I UNDER GE 881 EWS
2025_MES_744961_1
GE/PNH-60/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE 881 EWS, C/O 56 APO
As tender documents
8 documents required · 8 mandatory
₹500
Yes
GE 881 EWS
₹88,000
12 Jan 2026
17 Dec 2025
2 Jan 2026
17 Dec 2025
31 Dec 2025
25 Dec 2025
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
B/R Portion : Demolition of cement concrete (un-reinforced) not exc 15cm thick (below or above GL) complete all as specified and directed.
M&L for 5 mm thick rendering on ceiling surfaces in cement mortar 1:3, finished even & smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick work or cement concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement including mixing of water proofing compund complete all as specified and directed (Note: supply only liquid Water Proofing compound shall be measured and paid for separately)
M&L for applying wall care putty 1 to 2 mm thick on wall surfaces & smoothening the surfaces with sand papers etc., applying two coats of distemper oil emulsion (OBD) over a coat of primer complete all as specified and directed.
M&L for complete removal of existing treatment, applying wall care putty 1 to 2 mm thick on wall surfaces & smoothening the surfaces with sand papers etc and applying two coats of distemper oil emulsion (OBD) over a coat of primer complete all as specified and directed.
Preparing new surfaces of plasters and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered wall surface and applying two coats of cement base piant in camouflage pattern over a coat of alkali resistant primer complete all as specified and directed. (Note : pattern & colour of camouflage shall be as directed by Engr-in-Charge).
M&L for preparation of old steel or iron surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint, complete, all as specified and directed.
E/M Portion : Taking down carefully aluminium/copper point wiring (light, fan socket or power) complete including fittings & fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. and making good disturbed surfaces of walls, floors etc complete all as required and keeping serviceable light fittings in safe custody for reuse in the work as directed.
M&L for 75mm thick in Plain cement concrete type C2 ( 1:3:6)( using 40 mm graded aggregate ) as in plinth protection, laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth at top without using extra cement and providing joints throughout the thickness of plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4), type B-1 using 20 mm graded stone aggregate in floors, finished even and smooth using extra cement and laid in alternate bays, each panel shall not exceed 4 sqm complete all as specified and directed.
Complete removal of existing roof treatment of any description including screed bed etc. (any type and thickness) & coved fillets and removing demolished material out side MoD land complete all as specified & directed.
M & L for roughing of concerte surface, cleaning with steel wire issue brush to remove all loose dirt, dust & brushing with neat cement slurry @ 3 Kg per Sqm area complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:3 mixed with water proofing compound while concrete surface is green and finish the surface even and smooth without using extra cement complete all as specified and directed. (Note :- supply only WPC shall be measured & paid separetely)
M& L for Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends complete all as specified and directed
Supply & Fixed in repair counter top oval shape Wash hand basin as per existing size, White colour, Vitreous China excluding taps including waste pipe 32 mm dia of GI medium grade, to be fixed in grenite shelf including making of required hole in shelf and providing chromium plated coupling complete all as specified and directed.
Description all as per item No 27 above but except stone complete all as specified and directed.
M&L for post construction antitermite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed by Engr-in-Charge.
M&L 10 mm thick rendering in cement mortar 1:6 on stone masonry or other than fair faces of brick work, surface finished even & smooth without using extra cement complete all as specified and directed.
M & L for GI wire chicken mesh of size 25mmX25mm to concrete of joists, etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste fixed with nails complete all as specifed and directed.
M&L dry sand as in sand cushioning to under ground cable 8 cm thick before laying cable 15cm thick after laying cable including punning down complete all as specified and directed. (Note :- punned thickness 18 cm shall be measured & paid)
M&L for cement concrete 25 mm mini
mium thickness levelling course, type B-0, 1:2:4 (12.5mm graded stone aggregate) as in roof padding including filling of depressions & maintaining required slope including coved fillets complete all, as specified and directed by Engr-in-Charge.
Taking down carefully existing lightening conductor of any description and size from the roof or wall of bldgs and refixing at same location after repairing the roof treatment or wall plastering work incl necessary fixing arrangement (in case any damage to the conductor durig taking down & fixing, the same shall be repair/replaced with out any extra cost to the Govt.
M&L for 25mm thick PCC 1:2:4, type B-0 (using 12.5mm graded aggregate) as in sub base of floor/path/hardstanding complete all as specified and directed.
M&L for PCC type B0 (1:2:4) using 12.5mm graded stone aggt in filling of holdfast and steel etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but not exc 2 Sqm each with shutters. Complete all as specified and directed.
M & L for preparation of surfaces and applying bituminous primer (conforming to IS-3384-1965) @ 0.40 Kg/Sqm complete all as specified & directed.
S&F GI tubing medium grade 15mm bore with all fittings, cutting, threading and fixing to walls,ceiling or in floors. Complete all as specfied and directed.
M&L for 18-20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including moulding of corners as required, all as specified and directed..
M&L for 150mm bore reinforcement concrete pipes, class NP2, laid in trenches and jointed with collars complete all as specified and directed
Excavation in trenches not exc 1.5 m deep and 1.5 m wide and getting out in any type of soil complete all as specified and directed.
S & F for PVC (SWR)110mm bore vent cowl. Complete all as specfied and directed.
Removing excavated materials to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M&L for complete removal of existing treatment on plastered surface of wall and applying two coat of cement base paint in camoufalge pattern over a coat of alkali resistance primer complete all as specified and directed (Note : camoufalge pattern & colour shall be as directed by Engr-in-Charge).
Stainless steel decorative curtain rod 25 dia with decorative head on both end of rod and necessary clamps / fixing brackets, stops, rollers etc complete all as specified and as directed.
M& L for rough cast plaster as specified in clause 14.22 of SSR Part -I complete all as specified and directed.
Description all as per item No 51 above but without glazing bars.
S&F Aluminium alloy, anodised, sliding door bolt 250 mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed. Complete all as specfied and directed.
S&F switch piano flush type single pole, one way 6 amp complete all as specified and directed
M & L100 mm thick PCC 1:2:4 type B-2 using 40 mm graded crushed stone aggregate as in sub base of floors complete all as specified and directed
S&F switch piano flush type single pole, one way 15 amp complete all as specified and directed .
S&F socket outlet 2 in 1 , 3 pin 15 A flush type complete all as specified and directed.
S&F ceiling rose 65x50mm three terminals 230 volt complete all as specified and directed.
S&F socket outlet 2 in 1 , 3 pin 5 A flush type complete all as specified and directed.
S&F step type fan regulator electronic type in 5 step, 100 watt capacity switch/socket type complete all as specified and directed.
Supply and fixing inverter LED lamp, CDL 9 watt, B22 base, complete all as specified and directed.
Supply and fixing inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete
S&F distribution board double door type(for incoming MCCB & outgoing MCBs) TPN 4 way vertical type sheet steel powder painted with bus bar ,neutral link & earth bar etc. with IP 43 degree of protection flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified and as directed.
S&F sheet metal enclosures for MCB distribution board 230 Volts single pole and neutral 8 way double door type flushed inside the wall with 200 Amp rated bus bar incl making the surface good complete all as specified.
S&F MCBs SPN 63 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete.
S&F MCBs SPN 40 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete.
S&F MCBs SP 5 to 32 amp B curve 240 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete.
S & F in repair Vitreous china wash down water closet (pedestal pattern) white, with ‘P’ or ‘S’ trap, fixing long screws including connection to drain or outgoing pipe and to flushing pipe, and anti siphon pipe. Complete all as specfied and directed.
M & L for Cement concrete type E-2, 1:5:10 using 40 mm graded crushed stone aggregates as in foundation filling and mass concrete complete all as specified and directed
M&L for providing opening and grouting the nuts and bolts for fixing of exhaust fan in wall incl civil work as required on site and making the good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades, complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding the ceiling fan 1200mm Sweep with the same gauge of copper winding wire as well as number of turns and reassembling the fan after replacing the unserviceable spares like bushes, shafts, fasteners, bearings, capacitors and flexible cord for putting fan in serviceable condition including refixing the same after carrying out necessary repairs to original place all as directed by Engineer-in-Charge.
M&L for painting of ceiling fans and writing of MES No on fans in situ with synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc, complete all as specified and directed by Engineer-in-Charge.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 1.5 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.
S&F single pole and neutral sheet metal enclosures with a two pin and earth plug and socket 240 V, 230 volts, 50 HZ complete with one single pole MCB 20 A complete.
S&F lamp holder,PVC/Polycarbonate type and back plate suitable for batten fitting complete all as specified and directed.
S&F energy efficient LED light fitting, 45W, input voltage 110V to 280VAC, 50Hz with ingress protection IP 66, LM 80, stranded luminries with efficiency 100lumen/Watt, with secondary optics, perfectly matched lenses, complying to IEC60598/IS10322, with auto shut down on high voltage, CRI>70, PF>0.95, with short circuit & reverse circuit protection against 10kV high surges, minimum 25000 burning hours (life), operating temperature 1 to 50oC, rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 45W=10%W, rated lumens, 120o view angle, constant current type driver having THD<10%, including all fixing arrengment like clamps, nuts, bolts, washers, 45W LED rod lamp (havng PF>0.9, input voltage 90-300V, IP-66, LM80) with all accessories pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging, etc.including bracket complete all as specified and as directed
S&F MCCB 100 Amp, 4 pole 16 KA with adjustable thermal release fixed magnetic protection complete all as specified.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed
M&L for point wiring on wall/ surface in PVC casing caping of size 20mm complete with 1.5 Sqmm single core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade drawn through and including PVC casing caping and providing 1.5 sqmm FRLS PVC insulated unsheathed cable 1100 volt grade with multi stranded copper conductor to common earth and connected to earth dolly with sunken type pressed steel/welded MS terminal boxes made out of 1.6 mm MS sheet, 3mm thick laminated sheet top cover for mounting of fittings,switches, sockets outlets,regulators etc complete One light/Fan point controlled by one switch 5 amp one way complete.
S&F rotational moulded polyethylene water storage tanks duble layer, ISI marked (Cylindrical vertical with threaded closed top) hoisted and fixed in position all as specified in SSR Pt-I, capacity of tank 1000 Ltrs including dismantling existing unsericeable and removing to store. Complete all as specfied and directed.
S&F ceiling fans complete with three blade, down rod, accessories 230V, 1200mm sweep, BLDC fan with 5 star rating including fan regulator complete all as specified and directed.
M&L for Making bore to road/cement path/hard standing/Road for providing GI pipe 40mm for passing armoured cable incl making good the disturbed surface complete all as specified and directed.
S&F bus bar chamber of size 600x600x450mm suitable of 3 phase 433V outdoor type fabricated out of 3.15mm thick MS sheet with 300A rated aluminium busbar 4Nos., PVC sleeves (coloured red, yellow, blue and black) with suitable locking arrangments and four legged angle iron stand made of angle iron of size 40x40x6mm duly grouted in and including foundation in PCC 1:2:4 type C1 using 20mm graded stone aggregates alongwith all necesary cable connections, lugs and cable glands including applying two coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for coloured chequered cement concrete tiles with chemical resistant coating of size 30cmx30cmx2.5cm thick, machine pressed, laid in floors/Path etc. set and jointed with neat cement slurry and pointed with coloured cement to match laid over and including 20 mm thick screed bed or bedding layer of mortar in CM 1:4. complete all as specified and directed.
M&L for brick protection cover of old size bricks common sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
tender60.pdf
Tender Documents • 1.47 MB
BOQ_834142.xls
BOQ • 1.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .