Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹28.0 LAccepted-AOC 10 2 NARAYAN BAG INDORE M P | 1st | Accepted-AOC The lowest bidder M/s SS Engineers accepted please. | |
| 2 | 2nd₹29.5 L+₹1.5 L (5.35%)Rejected-Finance | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹30 L+₹2.0 L (7.19%)Rejected-Finance | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹32.5 L+₹4.5 L (16.0%)Rejected-Finance | 4th | Rejected-Finance L4 | |
| 5 | 5th₹32.8 L+₹4.8 L (17.3%)Rejected-Finance | 5th | Rejected-Finance L5 |
Tender Value
₹37.1 L
EMD Value
₹74,300
Closing Date
5 Jun 2023, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
ROVN OF 90 NO. LED ENERGY EFFICIENT PERIMETER STREET LIGHT FROM GATE NO. 03 TO STUDENT OFFRS MESS APPROACH ROAD INSIDE ARMY WAR COLLEGE MHOW
2023_MES_593536_1
8667 GE(AWC) /MHOW / OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
GE AWC MHOW
All as per NIT and Tender Documents
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹74,300
Yes
24 Jun 2023
6 May 2023
6 Jun 2023
8 May 2023
5 Jun 2023
22 May 2023
Amount
Supply, Installing, Testing and commissioning of LED Street light Fitting with a nominal system 5300 lumen output of lumens, minimum system efficacy of 115 lm/W and total power consumption not exceeding 45 W (including driver). The luminaire shall have a rated system lifetime of 50000 burning hours at L70B50. The Luminaire should have a colour temperature of 5700 - 6500 K and CRI > 80. The Luminaire shall meet IP66/Ik07 or IK08 rating with THD<10% and PF > 0.95. The luminaire housing should made of pressure die cast aluminium and the integrated luminaire optics shall have a high efficiency diffuser with more than 85% transmittance. The fitting should have an internal SPD of minimum 4 KV. The driver should have phase to phase protection for 8 hours. The luminaire should have a NABL approved LM79 report. LM80 report from the LED manufacture is a must along with biological report. Luminaire and the driver shall ben BIS certified separately and shall posses separate '' R'' numbers fitting should include nut bolt and SS screws for suitably fixing on the existing solar street light pole complete all specified and directed. Note:- 1. The light should have a beam angle >= 60 degrees 2. The Street Light should have a minimum 05 years warranty submitted by the tenderer from manufacture.
S & F Bracket for street light fitting made out of GI tubing 40 mm light grade pipe 2' x 1 -1/2' 135 degree bend with duly aluminium painted, cutting, welding and two MS bracket with nut bolts and washer bracing to pole/on fencing for street light fittings.
Excavation in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for laying of cables, pipes etc. and getting out all excavated material in any type of soil complete all as specified and directed.
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed.
Removing of excavated surplus soil to a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
M&L of Locally available river sand filling in trenches below and above / around UG cable for cable protection, in duct under & above the cables including punning around cable complete all as specified and directed. Note - Punned thickness shall only be measured and paid.
Supply and laying unreinforced PCC Cable protection cover, class LV, type-1 flat with size 250 x 150 x 40 mm laid flat width wise complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq. mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq. mm 4 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq. mm 4 core complete all as specified and directed.
S & F in replacement of PVC junction box IP -66/67 thermoplastic poly carbonate of size 205 X 255 X 112 mm , including connector block , two holes for incoming and outgoing cables, providing clamps made out of MS flat iron 25 X 4 mm, PVC glands of suitable size, MS hexagonal bolts, nuts and washers for arrangement to pole / surface complete all as specified and directed.
S & F in 12 KW , Three phase nature switch for automatic switching on /off street light based on lux level of nature light , consisting of sensor , overload protection fuse gear , power contractor and MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole / wall mountable enclosure made out of rust proof, shock proof , termite proof FR grade SMC , conforming to IP-54 , with universal lock and key arrangement complete all as specified and as directed.
S & L Tubes, 'light grade', galvanised, 50 mm dia for cable protection with all fittings and fixed complete to walls and ceiling or laid in floors/road crossing, all as specified.
S&F weather proof elastomer sheathed flat 3 core Copper wire cable of size 2.5 sqmm for connection of street light complete all as specified and directed.
Supply, installation, testing and commissioning LT PANEL board outdoor type (CPRI Approved) of suitable size Kiosk type factory assembled fabricated and of suitable size angle iron, channel and MS sheet 3.0 mm to 3.15 mm thick (inner compartment is 2.0 mm thick) double door type, front and rear openable with locking arrangement and duly prewired with colour code three phases and neutral for 415 volts, 50 Hz electric supply with and including suitable sizes of cable glands for incoming and outgoing cables cubical type duly powder coated over a coat of primer, grouting of panel 60 cm above the ground level by provisioned 90 cm long angle iron frame bottom of panel 40 x 40 x 5 mm thick, welded on all four corners, embedded in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate up to 30 cm and grouting the panel board on and including suitable size foundation structure with the following components. (a) MCCB TPN 250 Amps, 35KA 415 volts, Ics= 100% Icu, Adjustable short circuit setting type (incoming) – 01 Nos (b) MCCB TPN 100 Amps, 25 KA, 415 Volts Ics= 100% Icu, Adjustable short circuit setting type (outgoing) -01 Nos (c) MCCB TPN 63 Amps, 35 KA,415 Volts Ics= 100% Icu (out going ) -02 Nos (d) MCB TPN 63 Amps 10 KA, 415 Volts -02 No. (e) Aluminium Bus bar of capacity 600 Amps 3phase and neutral -1 set. (f) Digital type volt meter 0-500 volts. (g) Digital type Ammeter with CT of suitable ratio for reading up to 400 amps load-01 No (h) Indicating lamps R,Y& B -01 set (j) S & F in 12 KW , Three phase nature switch for automatic switching on /off street light based on lux level of nature light , consisting of sensor , overload protection fuse gear , power contractor and MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole / wall mountable enclosure made out of rust proof, shock proof , termite proof FR grade SMC , conforming to IP-54, with universal lock and key arrangement . (k) ON Load Change Over 4 pole 200Amp -01Nos
Design, Supply, installation, testing and commissioning of bus bar chamber box of size ) outdoor type along with one incoming MCCB 250 A 4 Pole 25 KA (Ics = 100% Icu) factory fabricated made out of CRCA sheet of 3 to 3.15 mm thick ,fully enclosed and angle iron frame of size 40 x 40 x 6mm thick and T section with front and rear openable double door shutter, dust and vermin proof and rear opening complete with locking arrangement, having a system of bus bars of aluminium of suitable size of 600 Amps duly insulated and mounted on Epoxy/porcelain insulators in totally enclosed chamber with three phase and neutral 415 volts, AC, system. incl provn of suitable cable glands, duly powder coated complete all as specified and as directed.
M&L earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.25 m deep below the normal ground level) with top edge of the earth plate not less than 1.5 m below normal ground level, connected to GI strip 25 x 4 mm size by means of bolts, nuts, check nuts and washers of , all as shown in electrical plate No. 3 connected to earthing test point and complete all as specified and directed. Note:- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C-1 (using 20 mm grade crushed stone aggregate) earth chamber, RCC 1:1.5:3, type A-1 cover slab, 40 mm thick reinforced with 6 mm dia TMT bar @ 150 mm C/C both ways, 10 mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 15 mm bore GI light grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
Raj Contruction
Vinayak Trading House
Ms Kailash Chandra Babulal
M/S UnitedConstruction
MODI CORPORATION
AGARWAL BUILDERS
Bharadwaj Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .