Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.5 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹17.0 L+₹2.5 L (16.9%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹18.7 L+₹4.2 L (28.7%)Rejected-Finance RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹29.5 L+₹14.9 L (102.7%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
Refer Docs
EMD Value
₹59,960
Closing Date
3 Oct 2020, 6:00 pmClosed
Maj ArjunSood
GE (East), Mathura
PROVN OF LED FITTINGS IN JCOs/OR MD ACCN AT OD COMPLEX AND PROVN OF SOLAR WATER HEATING SYSTEM IN BATHROOM AT BLDG NO. T-222 OR LIVING ACCN AT MATHURA CANTT UNDER GE (EAST), MATHURA
2020_MES_374754_1
8200-1159/E8
Open Tender
Civil Works
Works
180 days
GE (East)
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE (East), Mathura
₹59,960
19 Oct 2020
4 Sept 2020
5 Oct 2020
4 Sept 2020
3 Oct 2020
21 Sept 2020
Amount
Taking down old unserviceable non LED light fittings like as FTL light fittings / CFL Bulk head fittings / building security light fittings carefully and removing the material from site and making good the disturbed surfaces of walls ceiling etc complete all as directed.
M&L for Point wiring with 1.5 Sqmm (nominal area) single core PVC insulated unsheathed (FRLS) cable, multi-stranded, copper conductor, in universal colour code with & including suitable size of rigid non-metallic PVC conduit (not less then 20mm dia med gd)and its all accessories complete concealed in wall / roof incl cutting & chases( making good all to the disturbed surfaces as per existing) and modular flush metal boxes including cover plate with frame for fixing of modular switches, sockets, regulators etc including earth wire of PVC insulated (FRLS) copper conductor multistranded of 1.5 Sqmm size in green colour for one light point controlled by one way switch 5 amp complete all as specified
Supply and Fix ceiling rose surface bakelite 65mm x 50mm three terminals complete all as specified.
Supply and Fix Modular switch 6 Amps single pole one-way, 1 Module complete all as specified.
Supply & fixing indoor decorative ultra slim surface /Wall mounted aluminium extruded T5 LED batten tube light complete fitting 1x 20 watt 4' LED Tube fitting complete all as specified. Make :- Cat Part No LTTB4F20WLED Make C&S or equivalent make in philips/Havells. .
Supply & fixing indoor decorative ultra slim surface /Wall mounted aluminium extruded T5 LED batten tube light complete fitting 1x 9 watt 2' LED Tube fitting sitable for mirror light fitting complete all as specified. Make :- Cat Part No LTTB2F10WLED Make C&S or equivalent make in philips/Havells.
Supply and fixing environmental friendly, ultra modern, energy saving, surface mounted, decorative hexagon bulk head back-lit LED luminaire comprising of high brightness LEDs lamp of 10 Watt complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size of complete all as specified and as directed. Make :- Cat Part No LTB10WLED Make C&S or equivalent make in philips/Havells.
Supply and install of 25W LED building security light fitting with lens & driver, powder coated pressure die cast aluminium, voltage range of 140-280V including all connections complete all as specified. Make :- Cat Part No LTESSE25WLED C&S or equivalent make in philips/Havells.
M&L for building security light bracket made out of 40mm dia light grade GI pipe of 1.2 m length bent to required shape suitable for fixing street light fitting on Steel tubular pole including two Nos clamps made out 40mm X 6mm flat with suitable nuts and bolts including two coats of aluminium paint over a coating of red oxide primer complete all as directed taking down old unserviceable bracket as scrap any size / description.
M&L for Sub Main Wiring with two runs single core 4 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 4 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. Note :-Two run of 4 Sqmm single core cable, one run of 4 Sq mm earth wire & one run of PVC conduit will measured as one RM.
Supply, installation, testing & commissioning of Solar hot water heating system (Flat plate collector type conform to IS 12933 (part 1) with amdt no.1 & 2.. and IS : 12933 (part 2)/2003) with based on indirect transfer of heat of capacity 1000 litre per day with heat exchanger incl electrical heating back up with thermostat including cost of civil wks,aluminium angle frame mounting structure for collector box frame and mild steel support structure for hot water tank and collector with anti corrosive coating . , insulated hot water tanks (made with graded stainless steel of cap 1000 Ltrs , confirm to IS 1730 grade) , Temp Gauge, water meter and connection for heating backup etc. complete all as per latest provision and Section 26 of SSR Pt -I 2009 and as directed by Engr-in Charge. Make : Tata Power Solar Systems Ltd , Inter Solar System, Vikram Solar Pvt. Ltd. , Kotak Urja Pvt. Ltd., Inter Solar System Note : All components, equipments and accessories shall be conforming to latest Indian Standards as applicable The installation shall comply with the applicable codes of practice (wherever such codes of practice issued by the competent authority) regulations and Indian Electricity Rules and other safety regulations.
Supply & fixing Hot water pipe line 15mm bore GI Pipe medium grade conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 duly insulated with glasswool and aluminium cladding complete all as specified
Supply & fixing Hot water pipe line 25mm bore GI Pipe medium grade conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 duly insulated with glasswool and aluminium cladding complete all as specified.
Supplying & fixing 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 laid in trenches complete all as specified and as directed.
Supplying & fixing to wall and ceiling 20 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.
Supply and fix for Gun-metal gate valve / Stop Valve with iron wheel head screwed both ends for iron pipe of size 25mm bore and fixed complete all as specified and directed
Supply and fix Stop ball Valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions of size 25mm bore and fixed complete all as specified and directed
Supply and fix for Non return Valve / Reflux valve / Check Valve with by pass arrangement screwed both ends for GI pipe of size 25mm bore and fixed complete all as specified and directed
M&L for fancy type bib tap, cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe of size 15mm bore or for brass ferrule and fixed complete all as specified and directed
Supply & fix Rotational moulded polythylene water storeage tanks having 6 layer (for storage of cold water & Cleaning of colletors), ISI marked (cylinderical vertical with closed top ) hoisted and fixed in position as directed all as specified in SSR Part-I of capacity 2000 ltrs.
S&F Ball brass valve high pressure with polythene float and flynut complete screwed from iron pipe or brass ferrule and fixed of size 25mm complete all as specified .
M&L for cutting existing steel tubing of size 25/32/50mm bore for addition / alterations for new branch connection done in position without taking down.
Screwing existing steel tubing of size 25/32/50mm bore for alterations or additions done in position without taking down.
M&L and fabrication work for support mounting structure for cold storage tank with confirming to Fe-410-O or Fe-310-O as in cross arms, support, bracings, stiffeners, clamps channels, angles fabricated from structural steel including nuts, bolts and washers welding, bending cold or hot drilling holes for bolts in any shape or size all as directed including two coats of aluminium paint over a coating of red oxide primer all as directed by Engr-In-Charge.
M&L for mild steel sheet (plain or chequered) confirm to Fe 410-W(Gde-E- 250)quality-A, for fixing on top of cold storage tank structure including cutting , faabrication to required shape & size including welding work for fixing complete all as as per site requirements and as directed.
M&L Plain Cement Concrete M-15 grade (Nominal mix) using 20mm graded stone aggregate as in foundations, filling mass concrete for structure leg Posts including pilasters complete all as specified and directed by Engr - in Charge.
Earthing for Panel complete with galvanised steel earth plate electrode 60cmX60cmX6.0 mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe light grade and 40mm bore light grade GI pipe for protection of earth strip and connect to eqpt/pole/LA/panel point with use of Porceline insulator where required, common salt, charcoal dust including provision of earth test Point for earth test complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. Note: GI strip beyond 7.5Mtr length from earth electrode shall be measured and paid separately.
Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0 mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth wire of size 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with MS TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 15mm bore light grade GI pipe for protection of earth strip and connect to eqpt/pole/LA/panel point with use of Porceline insulator where required, common salt, charcoal dust including provision of earth test Point for earth test complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost all as directed by Engr-in-Charge. Note: GI wire beyond 7.5Mtr length from earth electrode shall be measured and paid separately.
Supplying & fixing 15 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 laid in trenches complete all as specified and as directed.
M&L for GI earth lead 4 mm burried in ground / fixed on walls complete with ffixing screws, nut, bolts etc complete all as specified and as directed.
M&L for GI Pipe light grade 40mm bore conforming to IS 1239 (Part-1): 2004 for earth strip protection in floor/road crossing/along bldg complete all as specified and as directed.
S&F earthing strip 32x6mm galvanized iron fixed to wall/pole/buried in ground /drawn in pipe complete.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core, laid in trenches / duct / fixing on walls / poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing including connecting with suitable lugs, glands, nuts and bolts in existing Panel to Prop Outdoor Panel and testing complete all as specified and directed.
M&L for Sub Main Wiring with three runs single core 6 Sqmm PVC insulated unsheathed (FRLS) cable with stranded copper conductor drawn in suitable size of rigid non-metallic PVC conduit and its all accessories complete concealed in wall/roof with and including 6 Sqmm copper green colour earth wire all as specified and directed by Engineer-in-Charge. Note :- Three runs of 6 Sqmm single core cable, one run of 6 Sqmm earth wire & One run of PVC conduit will measured as one RM.
Excavating in trenches not exceeding 1.5 mtr width and not exceeding 1.5 mtr in depth for laying of cables and getting out in soft /loose soil complete.
Removal of excavated surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested complete all as specified.
M&L for HDPE Double Wall Corrugated pipe of size 40mm outer dia and 32mm inner dia confirming to IS:14930 Part-II including necessary pipe fittings such as couplers, end caps, bend etc. laid in trenches / fixed to wall with suitable clamps (distance between clamps not more than 1 meters )for cable protection complete all as specified and directed. Make : Gemini/Stiple.
RAJ CONSTRUCTIONS
SM CONSTRUCTION COMPANY
R N AGRAWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .