Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹5.5 L+₹52,688.06 (10.7%)Rejected-Finance 33 PEMANTLE STREET KOLKATA 700016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L2 | Rejected-Finance 2nd lowest bidder | |
| 3 | L3₹6.0 L+₹1.0 L (20.6%)Rejected-Finance RAGHABPUR DK JAGADDAL KOLKATA 700151 | 24 PARAGANAS SOUTH | WEST BENGAL | 700151 | L3 | Rejected-Finance 3rd lowest bidder | |
| 4 | L4₹6.5 L+₹1.6 L (31.8%)Rejected-Finance | L4 | Rejected-Finance 4th lowest bidder |
Tender Value
Refer Docs
EMD Value
₹13,140
Closing Date
6 Sept 2021, 12:00 pmClosed
EE_II, Kol. South Health El. Divn.,P.W.Dte.
75 D H Road Kidderpore Kol_23
Renovation of Electrical Installation work and SITC of AC machines at new Server Room at Ground Floor of Administrative Building, MRBH, Tollygunge, Kolkata.
2021_WBPWD_339574_1
WBPWD/KSHED/Q28/21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
Kolkata
Please refer Tender documents.
2 documents required · 2 mandatory
₹13,140
O/o Exe.Engr., Kol. South Health El. Divn., PWDte.
12 Nov 2021
10 Aug 2021
8 Sept 2021
10 Aug 2021
6 Sept 2021
18 Aug 2021
17 Aug 2021
Amount
Distribution wiring in 3 x 22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells / Finolex/ RR Kabel) in 20 mm size MMS PVC rigid conduit 'FR' (Precision) to light/fan/call bell points with dark brown Piano Key type switch(Anchor/Vinay/Kolors) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 3 nos. suitable size “Ph, N & E” copper bar incl. bakelite/perspex (wall matching colour) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. Average run 9 Mtr.
Distribution wiring in 1.1 KV grade 3x22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells / Finolex / RR Kabel) in 20mm size PVC rigid conduit 'FR' (Precision MMS) to 6 A 5 pin flush type dark brown plug socket & dark brown Piano Key type switch (Anchor / Vinay / Kolors) fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite (wall matching colour) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish - On Board
Distribution wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Havells/ Finolex/ RR Kabel) of the following sizes in 20/25/40 mm size PVC rigid conduit 'FR' (Precision MMS) incl. necy. fittings as required -
2 x 22/0.3 (1.5 sq. mm) + 1 x 22/0.3 (1.5 sq. mm) ECC in 20 mm PVC pipe
2 x 36/0.3 (2.5 sq. mm) + 1 x 22/0.3 (1.5 sq. mm) ECC in 20 mm PVC pipe
2 x 56/0.3 (4 sq. mm) + 1 x 36/0.3 (2.5 sq. mm) ECC in 20 mm PVC pipe
2x80/0.4 (10 sq. mm) + 1x84/0.3 (6 sq. mm) ECC in 25 mm PVC pipe
4x196/ (25 sq. mm) + 2x126/0.4 (16 sq. mm) ECC in 40 mm PVC pipe
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Anchor/Vinay/Kolors) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 2 nos. 6A, & 2 nos. 20A dark brown plug socket with separate 2 nos. 6 A & 2 nos. 20A dark brown Piano key type switch, indicator & 20A switch type SP MCB (Anchor/Vinay/Kolors) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Legrand Myrius) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall with necessary fixing arrangement & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with following accessories a) 2+8way enclosure 1 no b) 40 A DP isolator 1 no and c) 8 no's 16A SPMCB (Make – Legrand / Schneider / ABB).
Supplying and fixing double door Horizontal 6 Way TPN MCB Distribution board with IP-42/43 protection, on wall with necessary fixing arrangement & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment with following accessories a) 6 way enclosure 1 no b) 100 A FP isolator 1 no and c) 18 no's 32A SPMCB (Make - Legrand/Schneider/ABB).
Supplying and fixing 415V, 125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type 125A HRC fuse as per rating. Make: (Siemens/L&T/Havells).
Supply and Laying of 1.1 kV Gr. 4 Core 35 sq. mm XLPE/PVC insulated & sheathed Armoured Aluminium cables [Make - Polycab/Havells/RR Kabel] for on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured 4 core 35 sqmm. Cable.
Finishing the end of 4 core 35 sqmm XLPE/PVC armoured cable by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
Finishing of the PVC insulated wire ends by socketing with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2 x 36/0.3 (2.5 sq. mm) + 1 x 22/0.3 (1.5 sq. mm) ECC
2 x 56/0.3 (4 sq. mm) + 1 x 36/0.3 (2.5 sq. mm) ECC
2 x 80/0.4 (10 sq. mm) + 1 x 84/0.3 (6 sq. mm) ECC
4 x 196/ (25 sq. mm) + 2 x 126/0.4 (16 sq. mm) ECC
Supply & fixing of twin LED Tube light fitting [Make - Philips cat no. TMC 501 P 2 x T-LED / Crompton cat no. IGP162 LT8-16] complete with 2x18/20 Watt LED tube lamp [Make - Philips Master LED tube model no.18W 865 T8I 2100 lm / Crompton cat no. LTT8-20 ] suspended below the ceiling with S & F 2x20mm dia EI conduit (14 SWG) up to 25 cm long with 'L' type MS clamp and making connection as to GS.
Supply & fixing of single LED Tube light fitting [Make - Philips cat no. TMC 501 P 1 x T-LED / Crompton cat no. IGP161 LT8-16] complete with 1x18/20 Watt LED tube lamp [Make - Philips Master LED tube model no.18W 865 T8 I 2100 lm / Crompton cat no. LTT8-20 ] suspended below the ceiling with S & F 2x20mm dia EI conduit (14 SWG) up to 25 cm long with 'L' type MS clamp and making connection as to GS.
S& F of 240 V 1200 mm (48") sweep Ac ceiling fan without regulator including down rod, canopy, fan blades etc. complete set and engraving and printing the departmental no up to 15digits on fan body and making necessary interconnection as required. The fan capacitor must be burst proof P2/s type ] Make: Crompton HS plus / Usha striker plus / Orient Energy Star]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supplying & Fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
Dismantling the existing EI set up including mending good the damages as per direction.
Supply & Fixing 240 V, Double Door 12 Way, SS DB with IP-42/43 protection (Make - Legrand/Schneider/ABB) concealed in wall incl. S&F of following electrical accessories with all interconnection made by 2 x 4 & 1 x 2.5 mm² single core stranded PVC insulated copper wire (Finolex / Havells / RR Kabel), finishing the wire ends by copper socket, provision of earthing attachment :-
i) 240V 25A DP MCB (C-Curve & 10 KA) (Make - Legrand / Schneider / ABB) -- 1no
ii) 24 Hr programmable Digital timer (Legrand, Cat No. 4126 31 / Schneider, Reference CCT15441 / ABB, Type D1) -- 1no
iii) 25 A power contactor (Legrand, Cat No. 4125 44 / Schneider, Reference - A9C20732 / ABB, Type code - AX12-30-10) -- 2 nos.
iv) 25A Auto-Off-Bypass DPDT toggle switch - 2 nos.
v) LED indication lamp (approved make) -- 2 nos.
Supply & Fixing Socket type fan regulator (Step type) (Anchor/Vinay/Kolors) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Supply & Fixing of perforated GI cable tray of size 200x50x1.25mm (18SWG)with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support and 25x25x3mm angle iron support with two nos. suspenders.
Supply of 2.0 Tr. Split type Air - Conditioner Machine having features modes (Auto/cool/fan/dry ) air flow (horizontal louver/vertical swing) sleep mode timer off/on anti freeze thermostat bio/active carbon/dust air filter [Make: Hitachi, Model No. RMOG324HDXA / Daikin, Model No. IDU - FDBF24CRV16 & ODU - RGF24CRV16 / Mitsubishi Electric, Model No. IDU - MS-GK24VA & ODU - MUGK24VA].
Installation of 2.0 Tr. split AC Machine including iron bracket (powder coated) for outdoor unit.
Supply of 2.0 TR window type air conditioner fitted with power saving rotary compressor having turbo cooling capacity of 6025 watt suitable for operating at 230+/- 10%, 50Hz AC supply, Discharge air flow volume (CFM) HXLXM 589/534/475 moisture removal capacity Ltr/ Hr 2.6 having features twin turbo fan modes (auto, cool, fan, dry)anti freeze thermostat, anti dust air filters, three step fan speed adjustment with star rating -3. with cooling agent R410A. (Make:- O-General, AXGT24FHTC)/ Mitsubishi Heavy Duty (WRK24MA1-6).
Installation, testing and commissioning of 2.0 Tr window AC including 2" shall wood frame and GI tray with proper fixing arrangement and mending good the damages.
Supply & laying Refrigerant Copper Pipe minimum thickness 1.15 mm. Liquid pipe 6.35 mm (1/4") & Gas pipe 15.88 mm (5/8") [Make Royku / Totaline/ Mandeep] and Insulation by nitril rubber of refrigerant Copper Pipe minimum thickness 9 mm. Liquid pipe 6.35 mm. & Gas pipe 15.88 mm.[Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non adhesive tape.
Supply of 25 mm dia heavy duty (40 grade) UPVC pipe with necessary elbows, connector, solvent cement & clamps etc. ( Make : supreme ).
Supply & drawing 3 core 2.5 sq. mm. P.V.C. insulated wire for connecting the Power hub to Outdoor unit supply. (Make Havells / Finolex / RR Kabel)
Supply & drawing 4 core 2.5 sq. mm. P.V.C. insulated wire for connecting the outdoor to indoor supply. (Make Havells/ Finolex/ RR Kabel)
Supply and fixing 40 mm dia PVC agricultural pipe on copper pipe lines to protect it from birds and environmental damage at outside portion of building only
Fabrication and mounting (including scaffolding job)of iron platform for fixing and maintenance of outdoor units of split type AC machines. The structure will be mounted at a height of 10 ft and should be fabricated with 50mm x50mm x6 mm thick ms angle for frame and 25mmx6 mm MS flat or platform portion duly welded, painted and grouted in wall so that it can carry load of outdoor unit along with the load of a maintenance person.
Dismantling the old damaged existing indoor and outdoor unit & store as per direction of EIC. Installation of the new indoor and outdoor unit, after Connecting the pipe line testing the leak by nitrogen gas pressure (minimum 400 PSI ) hold the pressure 12 hour and vacuuming the unit properly (Minimum -30 PSI) by double stage vacuum pump, vacuum should be observed up to 24 hours.
The Agency must procure the materials from the Manufacturer/OEM or from their authorized sales channel so that the standard warranty/supprot of the Manufacturer/OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer/OEM or from their authorized sales channel and standard warranty/support should be sent from the e-mail of the Manufacturer/OEM/authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
Defect Liability Period - 1 (One) year.
MILLENNIUM AIRCON
RUBY ENTERPRISE
M/S. TOAD TO TOWER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .