| 1 | L1₹8.2 CrAccepted-AOC | ₹8.2 Cr | L1 | Accepted-AOC REASONABLE LOWEST BIDDER |
| 2 | L2₹8.3 Cr+₹9.5 L (1.16%)Rejected-Finance | ₹8.3 Cr+₹9.5 L (1.16%) | L2 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 3 | L3₹8.5 Cr+₹28.3 L (3.46%)Rejected-Finance | ₹8.5 Cr+₹28.3 L (3.46%) | L3 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 4 | L4₹8.5 Cr+₹28.7 L (3.51%)Rejected-Finance | ₹8.5 Cr+₹28.7 L (3.51%) | L4 | Rejected-Finance NOT BEING LOWEST BIDDER |
| 5 | L5₹8.8 Cr+₹63.8 L (7.78%)Rejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹8.8 Cr+₹63.8 L (7.78%) | L5 | Rejected-Finance NOT BEING LOWEST BIDDER |
Tender Value
₹9.5 Cr
EMD Value
₹8.0 L
Closing Date
15 Nov 2022, 6:00 pmClosed
CE RND SECUNDERABAD
CE RND OPP JBS PICKET SECUNDERABAD
PROVISION OF TEST FACILITIES FOR INFRASTRUCTURE EVELOPMENT FOR MULTISTATIC SURVEILLANCE SYSTEM MSS AT DRDO SITE S1 AND S2 FOR LRDE BANGALORE
2022_MES_553529_1
82631
Open Tender
Civil Works
Lump-sum
365 days
BENGALURU
AS PER NIT
8 documents required · 8 mandatory
₹3,000
Garrison Engineer I RnD WEST Bengaluru
₹8.0 L
Yes
30 Dec 2022
22 Sept 2022
22 Nov 2022
22 Sept 2022
15 Nov 2022
8 Nov 2022
22 Sept 2022 - 10 Oct 2022
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.04) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Test Facilities for MSS at S1 at LRDE complete all as shown on drawings and as per specification. complete all as shown on drawings and as per specification.
Lumpsum price worked out by the contractor for Construction of Test Facilities for MSS at S2 at LRDE complete all as shown on drawings and as per specification. complete all as shown on drawings and as per specification.
Lumpsum price worked out by the contractor for Provision of LLDPE septic tank of 25 users designed to carry sewage and sullage water,excavation in any type of soil,PCC 1:4:8 below foundation, vent shaft connection etc complete all as specified and directed for 25 users.
Lumpsum price worked out by the contractor for Soakage well of size 1.20 m dia and 3.00 m effective depth, including excavation in any type of soil,foundation in PCC 1:3:6 walls of honey comber masonry with top ring of M25 concrete including intercepting chamber made of brick masonry in cement mortar,RCC cover slab in M25/SFRC cover,interconnecting pipes of RCC/DWC complete filled with brick bats complete all as specified.
Lump sum price worked out by the Contractor for “EXCAVATION, EARTHWORK, SITE CLEARANCE, AREA DEVELOPMENT AND DEMOLITION” as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of ₹60,86,163.18 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ ROAD / PATH / CULVERT / HARD STANDING ” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of ₹ 1,77,21,118.33 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹73,498.40 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of ₹10,54,066.64 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for "GALVALUME ROOF SHED FOR DG SET AND AMF PANEL” as listed in Schedule ‘A’ Part - VI representing _______ % __________________ percent Above / Below the lump sum price of ₹2,71,704.13 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for "RAMP WITH TEST BED & OPEN MS STAIRCASE TO TEST BED” as listed in Schedule ‘A’ Part - VII representing _______ % __________________ percent Above / Below the lump sum price of ₹2,94,60,791.56 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of ₹5,65,679.02 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIC SUPPLY” as listed in Schedule ‘A’ Part - IX representing _______ % _________________ percent Above / Below the lump sum price of ₹20,64,656.60 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “REFRIGERATION AND AIR CONDITIONING” as listed in Schedule ‘A’ Part - X representing _______ % _________________ percent Above / Below the lump sum price of ₹6,04,726.96 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “ INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - XI representing _______ % _________________ percent Above / Below the lump sum price of ₹15,247.62 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “ INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - XII representing _______ % _________________ percent Above / Below the lump sum price of ₹8,18,568.22 inserted by the MES in Schedule ‘A’ Part - XII
Schedule 'A' Part - XIII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 14.00 to 57.00
Surface dressing and levelling by using mechanical means (Hydraulic excavator) all as specified and directed. complete all as specified and directed.
Supply only soil approved by Accepting officer / Engr-in-charge brought from outside MD land including loading / unloading to the point, complete all as specified and directed.
EXTERNAL WATER SUPPLY Drilling, trial bore well vertically by using high speed high power DTH(Down the hole) drilling or any other approved latest method of drilling of size 6½"(inch)dia as per site requirements, through any type of soil / rock strata such as hard soil, loamy soil, sandy clay, red clay, moorum, weathered rock, hard rock, lightly fractured rock, pebbeled rock, or any other geological formation at given location by ground water survey exports all as specified in IS-2800 and as specified and directed for depth n. exc 200 mtrs below ground level for 02 Nos bore wells at S1 and S2 site
Drilling of trial borewell vertically by using high speed high power DTH(down the hole) drilling or any other approved latest method of drilling of size 6½" (inch) dia exceeding 200mtrs and not exceeding 400mtrs below ground level for 02 Nos bore well ar S1 & S2 site. Notes (for item No 16& 17):- (i) Collection and submitting of soil strata at every 10mtrs depth and every change in strata for entire depth of borewell contained in suitable hard wood box of suitable size for each sample and box shall be fixed with 3mm thick plain glass in front side and writing the details as directed. (ii) Location of bore well and depth to be dug as recommended by CGWB. (iii) 02 Nos borewells to be dug at two different locations at S1 and S2 site. (iv) Removal of mud/slurry from the site shall be deemed to be included in the quoted unit rate. (v) The rate quoted is deemed to include for hire charges of rig, T&P, machinery, fuel charges, labour, consumables, transportation, drilling and operation including use and waste of all necessary appliances and materials in all respects to entire satisfaction of complete work all as specified and directed.
Electro logging test of water bearing zone identification including all tools and equipment, complete all as specified and directed for 02 Nos bore wells at S1 and S2 site .
Development of Borewell as drilled trial bore under this schedule here-in-above with compressed air by means of air compressor of suitable capacity and over pumping using suitable capacity pump set till the clear water is received from 02 Nos Bore wells at S1 and S2 site complete all as specified and directed. Note:- The item includes: (i) Collecting water samples in clean bottle / jar from borewell and getting tested for chemical, bacteriological analysis and PH value from Govt laboratory and submit the report. (ii) Filling of gravel pack provided in fine aquifers all around the bore well Casing pipe upto depth of 2mtrs or as per norms and as directed.
Carrying out yield test (V-notch type) of bore well continously for 08 hours and submitting the test report in the presence of departmental representative complete for 02 Nos bore wells at S1 and S2 site all as specified and directed. Note: T&P required for yield testing shall be arranged by the contractor without any extra cost to Govt.
Supply , lowering, testing and commissioning of Submersible pump set, vertical type, multi stage with copper wound brass impllers duly coupled to submersible motors electric driven 10 HP(approx) 415 Volts, 3Phase, 50 Hz suitable to meet the head and discharge after yield testing, including connecting of pipes and electic connections etc., as per site requirements complete complete all as specified and directed. Note: Contractor shall submit techincal literature of submersible pumpset for approved of GE. Make: KIRLOSKAR / CG / JYOTHI/ GRUNDFOS
Supply and laying submersible copper conductor cable 1100 volt grade, PVC insulated and PVC sheathed with multi stranded copper conductor of size 6.0 sq mm, 3 core cutting to required length , connecting with necessay ferruls/ water proof joint, complete all as specified and directed.
Supply, lowering, install, test and commissioning of submersible pump electric driven cap 2 HP 230Volts complete for underground sump to overhead tank purpose including starter and connection for 02 Nos bore wells at S1 and S2 site, complete all as specified and directed.
Fixing only for MS reducer bail plug well cap MS strip for centering MS iron clamps electric logging and sample strata box, complete all as specified and directed.
Supply, lowering, installation PVC casing Pipe 250 mm dia 10kg/sqcm,ISI marked heavy duty including all connected accessories and fixing arrangement duly reaming bore hole with T&P / machinery as per site requirement for 02 Nos bore wells at S1 & S2 Sites,, complete all as specified and directed
Supply, lowering, installation PVC casing Pipe 07''(inch) dia 10kg/sqcm,ISI marked heavy duty including all connected accessories and fixing arrangement duly reaming bore hole with T&P / machinery as per site requirement for 02 Nos bore wells at S1 & S2 Sites,, complete all as specified and directed
Supply, lowering, installation PVC slotted Pipe 05''(inch) dia 10kg/sqcm,ISI marked heavy duty including all connected accessories and fixing arrangement as per site requirement for 02 Nos bore wells at S1 & S2 Sites,, complete all as specified and directed
EXTERNAL ELECTRIC SUPPLY & STAND BY POWER SUPPLY Supply, fixing and testing MCCB 4 pole 100 Amps 25 KA, 415 Volts, 50 Hz fixed thermal and fixed magnetic setting type - One No in and including sheet metal enclosure outdoor type CRCA sheet not less than 3 mm thick from any CPRI certified manufacturerers with canopy all four sides duly mounted on Angle iron frame of size 50 x 5 mm along with necessary earth work PCC work for foundation, coping etc complete all as directed. Location : Near existing Elect source panel, the charges for connections of LT UG cable from existing source panel to MCCB and material i,e lugs, glands etc as per site requirements deemed to be included in the quoted rate. However LT UG cable required from existing souce panel to MCCB shall be measured and paid under relevent item of schedule here-in-after complete all directed
Supply, fabricate, installation, testing and commissioning self supporting totally enclosed factory fabricated LT feeder pillar box made out of not less than 3.15 mm with CRCA sheet from CPRI Certified panel manufactureres with projected globe roof for rain water protection, dust and vermin proof hinged double shutter doors with neorprene rubber gasket, powder coated including danger plate, earth strip ventilation louvers, bottom detachable gland plate complete with suitable size zinc chromium plated nuts, bolts and washers etc, out door type cubical panel board suitable for 3 phase 4 wire, 415 vots, 50Hz mounted on suitable size MS channel fixed on PCC foundation and pedestal height comprising the folowing :-
Cutting of road / floor for laying of new cable /GI Pipe not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for refilling / with material and, watering well ramming / compacting and making good with PCC 1;3;6,type C-1complete all as specified and directed. Note : PCC 1:3:6 shall be measured and paid under the respective item of the work.
M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth strip 32X6 mm by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI light grade 40mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil including getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I including taking up of old GI earth plate all as specified and directed. Note: Cost of Earth lead & GI protection pipe upto 7.5m shall be deemed to be included in the quoted rate.
M&L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI light grade 15mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil and getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed. Note: Cost of Earth lead & GI protection pipe upto 7.5m shall be deemed to be included in the quoted rate.
Supply, fabricate, install, testing and commissioning for outdoor type LT Bus bar Chamber Box of size 600 x 600 x400 mm from CPRI validity certified panel manufacturers with powder coated painting made out of 3 mm CRCA sheet steel front and rear opening facility with towerbolt locking , pad locks - 02 Nos,Provn of earthing points - 02 Nos and four side slanting cannopy on roof top and mild steel channels base frame of suitable siize and placed with suitable PCC pedestal of not less than 0.6 mtr height as per site requirements in and incl TPN Aluminium Bus bar of 100 Amps Capacity for looping and branch connection the bus bar chamber placed on insulators with suitable Neoprene rubber gasket to make it completely dust and vermin proof complete all as specified and directed by Engineer- in charge. Note:- The quoted rate deemed to be included for connections of Incoming and all outgoing U/G cable, terminating with suitable cable gland, aluminium lugs in and including excavation,returning,removing and PCC work as per site requirement complete all as directed by Engineer-in-charge.
Supply , Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 55 fabricated by CPRI approved panel manufacturere's in and including suitable terminal TPN 10 KA SMC Connector ( Make - Electro Fibres / Powermat / Ramanuj for 3 Phase Cable Line IN & OUT) , MCB 6 SP Amps - 02 Nos `C'curve canopy weather proof hinged doors, locking system and arrangements for fixing on Steel Poles with MS clamps of size not less than 32 x 5 mm nut bolts washers etc as per site requirement complete directed. Note : MCBs shall be measured and paid separately.
Supply & fix PVC insulated 1100 volts copper conductor for working voltage upto and including 1100 volts of size 1 sqmm 3 core round type from loop in box to fitting complete all as directed.
Supply and fixing MCB SP 6 Amps 'C' curve Type 240 Volts AC, 50 Hz complete all as specified and directed..
Supply,Installation, Testing and Commissioning of 45W LED street light . Housing Made of Die-Cast Aluminium , Diffuser should be Clear Heat Resistant Toughned Glass IK07 with IP 65 Protection , System Efficacy should be >=110 Lm/W. Operating Voltage Range of 120V- 270V AC and Frequency 50HZ, Power Factor 0.95 ,THD<10%, Each LED with Individual lens and LED Life 50000 Burning Hours as per L70, CCT 5700K ANSI, CRI >70 and Driver Should be Potted type Constant Currnet LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R numberother safety test as per IS 15885 Part-2/Sec 13 . LEDs comply to the Photo biological safety standards as per IEC62471 and RoHS complete in all respects all a directed. Make Crompton Model No : LSTS-45-CDL-M or Equivalent in Philips /Bajaj
Steel tubular swaged poles type 410 SP 31 (Overall length 9.00 metre) double swan neck, neck angle as directed based on the site requirement complete with cast iron base plate, finial taper plug, with necessary bolts, nuts and washers screws, pole shall be painted with two coat of black bituminous paint throughout internally and externally upto planting depth (i.e., embedded portion in ground / concrete) and the remaining external complete pole portion shall be painted two coat of aluminium paint over a coat of red oxide primer, painting of black & yellow alternate strips of 30cm each externally from ground level upto 1.5m with synthetic enamel paint, complete all as specified and directed. NOTE:- Excavation in trenches, PCC in bed concrete, foundation and coping shall be measured and paid separately under respective items of this Schedule.
Supply errect testing and commissioning 20 Mtr. High Mast suitable for 180 km/hr wind speed and suitable for mounting Max 8 Nos 300 W LED luminaires consisting of Head Frame Movable lantern carriage Double drum Winch-750 Kg SWL 6 mm 316 Grade S.S Hoisting Ropes of 7/19 construction Flexible Multicore cable Trailing Cable -5 Core X 4Sq. mm 1 No per mast Foundation Bolts & Nuts Anchor Plate & Template Lightning finial.Integral Power Tool complete all as directed. Make - Crompton/Philips/Bajaj Note :- The all items of works of high mast structure except here-in-after works shall be included in the quoted rate and no extra amount will be paid in this regards.
Supply,Installation, Testing and Commissioning of 300W LED Flood light . Housing Made of Die-Cast Aluminium , Diffuser should be Clear Heat Resistant Toughned Glass IK07 with IP 66 Protection , System Efficacy should be >=110 Lm/W , System Having 10KV Surge apart driver surge, Fixture should be with safety chain for safety . Operating Voltage Range of 120V- 270V AC and Frequency 50HZ, Power Factor 0.95 ,THD<10%, Each LED with Individual lens and beam angle of 60 Deg, LED Life 50000 Burning Hours as per L70, CCT 5700K ANSI, CRI >70 and Driver Should be Potted type Constant Currnet LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R numberother safety test as per IS 15885 Part-2/Sec 13 . LEDs comply to the Photo biological safety standards as per IEC62471 and RoHS omplete in all respects all a directed. Make Crompton Model No : CFS-501-300-57-60D-SL-GL-NGG Or Equivalent in Havells/Bajaj
Supply fixing testing commissioning Automatic On / Off control panel for high mast motor operation for item No 39 here-in-above complete all as directed.
Material and Labour for Civil foundation, Erection of mast with Crane, panel earth & earth connections for high mast, panel grouting etc all as per manufacturerers recommendations for item No 39 here-in-above complete all as directed.
Supply fixing testing Twin LED aviation fitting 1 No for item No 39 here-in-above complete all as directed.
Supply installation testing and commissioning of silent Diesel Engine driven generating set 415 volts, 100 KVA / 80 KW 3 phase 0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, With all complete all connected acessories in all respects for commissioning of the DG Set, with CPCB approved Accoustic enclosure IP 23, self excited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Bangalore including AMF panel and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following:-
Alternator - Standard design alternator, Power Rating 100 KVA/ 80 KW, 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8(lagging) Current 139 Amps, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, 1500 RPM, Cooling Liquid cooled, Aspiration Turbo charged, air cooled self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, A1 The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722. Make of the Alternator as per list of Makes.
Diesel Engine : Adequate capacity Diesel Engine suitable for 100 KVA coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, water cooled engine with 4 cylinder, 4 stroke mechanical governor first fill lube oil and coolant, direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under : Insulation class - 'H' , Temperature rise class - 'H' ,Excitation- Self excited Regulation performance - The voltage is kept constant with + 1%, manual voltage adjustment with in + 5%. , Frequency Regulation + 1% Suitable size & suitable number of runs of UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel is deemed to be include is quoted rate. Make of Engine as per list of makes.
(i) Flywheel with housing (ii) Cooling System : Mounted radiator with fan and belts (iii) Cooling Water Pump : Centrifugal type belt driven (iv) Exhaust System : As per OEM reccommendation/specification. (v) Starting System :- Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Batteries :- 24 Volts DC electrical batteries of suitable AH rating, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified and directed. (vii) Fuel tank of adequate capacity :- As per OEM norms and specifications designed for 8 hours full load diesel storage capacity inbuilt fuel tank. (viii) First fill of oil and diesel during commissioning and 12 hours testing at work site.
AMF Panel : Auto Main Failure (AMF) Out door type Panel made out 3.15mm thick CRCA sheet,cubical type from CPRI approved manufacturer, weather proof powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 100% load of 100 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable, all as specified with the following accessories, control cable from Gen Set to AMF Panel.
Contactor of Suitable capacity 3 pole with required nos as per OEM, TP contactor for netural for both supplies Suitable capacity of MCCB, 4 Pole for both supplies CTs 150/5A for both the supplies Push buttons Indication Lamps
2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic/Manual Switch. Hooter. Voltage sensing relay. Six window anunciator for fault indications.
Acoustic Enclosure : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions, with the following features :-
(i) Custom built product for various equipments, with ensure the optimum performance without duration. (ii) 16SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyster powder/epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic/weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.
(vii) Working space is to be provided around the equipment for easy maintenance/repairs. (viii) Necessary cut out provision for entry and exist of fuel lines cable to be incorported in the enclosure as per the requirement. (ix) See through transparent window(glass or acrylic) in front of engine panel to be provided for monitoring the operation. (x) Ducting if required, bellows, mechanical hardware like locks, hinge, fasters etc to be provided. (xi) Deliverables 75DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturers recommendations above ambient temp. (xii) The enclsoure should be provided with bulk head light fitting for inside illumination. (xiii) The exhaust pipe along with proper aluminium cladding, shall be laid to a height of above the roof level. The rates for the same are to be included in the quoted rates.
(xiv) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform. (xv) The DG set should be provided with external emergency stop push button. (xvi) Provn of 2 Nos 11 Watts LED lamp fitting of approved Make incl wiring inside canopy with single switch controlled. (xvii) Fuel gauge to be provided with the neck of fuel tank. (xviii) Tools as per manufacturers with the box. (xix) Invents of suitable company be manufacture. (xix) The acoustic enclosure parts shall be of powder coated after pre treatment process.
(e) Civil Work : All civil works including RCC/ PCC platform 1:3:6 type C2 and related to foundations including of panel and equipments including of panel and equipments including making good and existing structure of disturbed during installation and commissioning of Gen Set, The depth of the foundation shall be minimum 300mm with anti vibration pads or as recommended by the manufacturer. The foundation drawing for DG Set shall got be approved by Engr-In-Charge before laying of foundation. The Contractor has to obtain approval for RCC/PCC foundation for the DG Set with the manufactures, Rates shall be quoted accordingly with written certificate from the manufacturers for the same.
Control panel: powder coated control panel made out of CRCA sheet comprising of MCCB of suitable rating, controller which displays voltage, current,KW,PF,Frequency,Kwh, Indicating lamps for "Load on "and "Set Runing", current transformers of suitable ratings with control wiring with fuses
Supply,fixing and testing of voltage stabiliser of 5 KVA, capacity single phase input variation 170V-250V, output voltage stabilised at 230Volt,complete all as specified and as directed.
Supply,fixing and testing of voltage stabiliser of 1 KVA, capacity single phase input variation 170V-250V, output voltage stabilised at 230Volt,complete all as specified and as directed.
INTERNAL ELECTRIC SUPPLY MCCB DB sheet metal enclosure 415 volt facility to fix MCCB in incomer and MCB's outgoing, TPN vertical type 4 ways, Double door IP 43 type complete fitted with bus bars neutral links, cable entry boxes fixed flush to wall,complete all as specified and as directed.
Supply & Fix LED light fitting batten type wall mounted 20 Watts,lumens of fitting not less than 110Watt, 240 Volts, Polycarbonate housing and integrated driver complete with all accssories and fixing arrangement on wall surface by providing suitable flexible wire from ceiling rose to fitting all as specified and directed.
Supply & Fix LED light fitting batten type wall mounted 10 Watts, lumens of fitting not less than 110Watt, 240 Volts, Polycarbonate housing and integrated driver complete with all accssories and fixing arrangement on wall surface by providing suitable flexible wire from ceiling rose to fitting all as specified and directed.
Supply & Fix LED light fitting 36 Watts,lumens of fitting not less than 110Watt, 240 Volts, surface type lumniaire suitable for 2x2 feet complete with intigrated driver complete with all accessories and fixing arrangements by providing suitable flexible wire upto light fitting all as specified and directed.
Supply & Fix LED Security light fitting 20Watts,lumens of fitting not less than 110Watt, 240 Volts, Pressure die-cast powder coated suitable for Building security clear acrylic cover and complete accessories including suitable GI bracket bent to shape of adeqade length including necessary MS brackets, nuts and bolts etc. for mounting and including driver and connecting up complete all as specified and directed.
REFRIGERATION AND AIR CONDITIONING Supply install testing and commissioning RO water filter of pure water discharge 20 litres/hour and storage tank cap 11 ltr single phase 240 V complete all as directed by Engineer-in-charge. Make:Kent pearl with digital or equivalent / higher specifications model in Aqua guard,complete all as specified and as directed.
ROAD / PATH /CULVERT/HARD STANDING Supply and fix, solar road stud having 3 LEDs of colours red/yellow to a side (total 6 Nos) housed in a tough pressure die casted aluminium alloy of any size (120 x 130 mm) / (100 x 130 mm) / (125 x 125 mm) of height 20mm with built in stem-nail 30mm x 50mm long for fixing withepoxy. LEDs solar cells, battery & light sensor well protected in side under tough unbrakable polycarbonate transparent sheet roof system workable for 2-3 days(Nights) after full charge in 8-10 Hours. Make:GREENS/ GREENLITE / 3M
Supply and fix, ABS 60cm reflected convex mittor with 130 degree of viewing angle for outdoor (road side) purpose made of polycarbonate,ABS body fixed in position with hood with mounting hardware, complete all as specified and as directed.Make: ACE Polymers(India) or equivalent approved Make.
Supply and Laying riddled earth soil confirming to IS-1255 in cable trenches for protection of cables complete all as specified and directed
Material and labour for pre-Moulded joint filler bitumen impregnated fiber board pressed and hold in poisition & fixed including preparation of existing concrete surfaces using a coat of hot bitumen of grade 85/ 25 to fix 30mm of 300mm width fiber board including 2mm thick of 150mm width aluminium shutter cover fixed with screws, complete all as specified and directed
Providing, laying, spreading and compacting ground stone aggregate(size range 53 mm to 0.075 mm) to wet mix macadam(WMM) including premixing the material with water at OMC for all leads & lifts,laying in uniform layers of 75 mm thick in two layers,a total of 150 mm with mechanical paver finisher in sub base/base course on well prepared surfaces with vibratory roller of 8 to 10 tonnes capacity to achieve the desired density as per IS 2386 complete all as specified and directed.
Painting lines, dashes, arrows, letters, etc., on roads, pavements and the like exc. 10 cm wide with Retro-Reflective Thermoplastic road marking paint, white or golden yellow, conforming to MoRT&H specification all as per manufacturer's specification and as directed.
SREEKRISHNACONSTRUCTIONS
Sri Lakshmi Constructions
M/s SRINIVASA CONSTRUCTION COMPANY
Phoenix Infra
M/s M Munivenkatappa and Company
NITYA NAND AND SONS CONTRACTORS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .