O/o SE OMC-IV BTPS PTPP
Routine up keeping of power cables, cable galleries at zero meter 10 meter elevation with their racks at Boiler ,Turbine and BOP area of 2X210 MW Electrical maintenance of EOT Cranes and Electrical Hoists installed at BTPS
2022_RVUNL_736356_1
N-PAR////6000000654-00
Open Tender
Electrical Works
Lump-sum
365 days
BTPS PTPP
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
Dy. CAO, CFA BO, PTPP, Parichha
₹25,000
Yes
18 Nov 2022
11 Oct 2022
1 Nov 2022
11 Oct 2022
1 Nov 2022
11 Oct 2022
Amount
Routine up keeping of HT/LT power cables (Except Cable gallery at Zero mtr and Ten mtr)and maintaining exhaust fans and other miscellaneous work in 2X210 MW of BTPS.(One job consist of one month period).
Routine cleaning of cable galleries floors (Size : 132Mx8.6M, cleaning of cable galleries roofs, all four side of walls ) at zero meter & ten meter elevation elevation,cleaning of cables in cable galleries and out side area of DG sets building in 2X210 MW of BTPS.(One job consist of one week period).
Routine and preventive Electrical maintenance of 06 Nos. EOT Cranes and 29 Nos. hoists installed at various locations in 2x210 MW, PTPP, Parichha as per Scope of work of Part-A 1.3 detailed from Sl. No. 1 to 27.
Routine checking of ceiling fans/wall mounted fans located at different places in 2x210 MW in BTG & BOP area of BTPS .
Providing staff to attend crane/Hoist faults during Night hours(as per instructions of Executive Engineer)
Salvaging/laying of HTUE &XLPE cable per meter 1CX800 & 3CX185
Salvaging/laying of LT cable per meter 1CX800 ,3CX240 &3CX300 &1CX630 ,3CX150 & 3CX185
Salvaging/laying of LT cable per meter 1CX400 ,3CX120 &1CX300 &1CX240 ,2CX120 ,3CX95,3CX75 & 1CX185
Salvaging/laying of LT cable per meter 1CX150 ,1CX120 &3CX50
Salvaging/laying of LT cable between 35 sq mm to 50 sq mm size
salvaging/laying of LT cable below 35 sq.mmper meter
Straight through jointing of HTUE & XLPE cable per set of 1CX800 & 3CX185
Straight through jointing of LT cable per set of 1CX800, 3CX240 ,3CX300,1CX630 ,3CX150 ,3CX185
Straight through jointing of LT cable per set of &1CX400 ,3CX120 ,1CX300,1CX240 ,2CX120 ,3CX95,3CX75 ,1CX185
Straight through jointing of LT cable per set &1CX150 ,1CX120 &3CX50
Straight through jointing of LT cable size between 35 sq. mm & 50 sq.mm per meter
straight through jointing of LT cable below 35 sq.mm per meter
Relugging of HTUE &XLPE cable per set of 1CX800 , 3CX185
relugging of LT cable per set of 1CX800 ,3CX240 &3CX300
relugging of LT cable per set of 1CX630 ,3CX150 &3CX185
Relugging of LT cable per set 1CX400 ,3CX120 &1CX300,1CX240 ,2CX120 ,3CX95,3CX75, 1CX185
Relugging of LT cable per set of 1CX150 ,1CX120 ,3Cx35,3CX50
Relugging of LT cable per set from 35 sq mm to 50 sq mm per mtr
Relugging of LT cable per set below 35 sq mm per mtr
End termination of HTUE &XLPE cable per set of 1CX800 & 3CX185
End termination of LT cable per set of 1CX800 ,3CX240 &3CX300
End termination of LT cable per set of 1CX630 ,3CX150 &3CX185
End termination of LT cable per set of 1CX400 ,3CX120 &1CX300
End termination of LT cable per set 1CX240 ,2CX120 ,3CX95,3CX75 & 1CX185
End termination of LT cable per set of 1CX150 ,1CX120 &3CX50
End termination of LT cable size between 35 sq. mm & 50 sq.mm per meter
End termination of LT cable below 35 sq.mm per meter
Erection of various type of TPN switch/starter/welding receptacle upto 63 A rating.
Erection of various types of TPN switch / starter above 63 A rating.
Digging of earth for location & attending faulty portion of cable and refilling in same manner after attending the fault per cubic meter.
Providing cable markers as danger board at every 10 meter to Avoid damage to underground cable by grouting 2 Ft. long angle Pieces wherever required.
Removal & refixing of chequer plate or grid or fire proof board for attending cable fault on beneath the racks or for maintenance purpose.
Writing of nomenclature in size of 1-1/2 inch as and when required anywhere on panel board as per scope of work.
Laying/Removal of Control cables of all types from Trench/Tunnel & cartage/storage at site store by proper re-rolling.
Providing new tray cover at different locations and clamping thereof as per size.
Painting of trays/plates or other MS structure with red oxide primer with material per sq meter.
Painting of trays/plates or other MS structure with synthetic enameled of reputed brand with material per sq meter.
Re-winding of ceiling Fan /Pedestal Fan/Cabin Fan/Single phase exhaust fan /Wall Fan
Rewinding of exhaust fan up to 01 KW
Rewinding of exhaust fan above 01 KW to 03 KW
Rewinding of exhaust fan above 03 KW
Overhauling of Exhaust Fan up to 3 KW(Three phase)
Overhauling of Exhaust Fan above 3.0 KW to 5.0 KW(Three phase)
Overhauling of Ceiling Fan /Cabin Fan
Supply & replacement of bearing of ceiling fan as per scope of work.
Supply and replacement of rotor shaft of ceiling Fan Motors as per scope of work.
Supply and replacement of condenser of ceiling fan. (2.5 MF)
Supply and replacement of ceiling fan regulator
Installation/Shifting of Ceiling fan /Tubelight
Supply & replacement of bearings in exhaust fan
Supply and replacement of rotor shaft of Exhaust Fan Motors.
Supply and replacement of condenser of Exhaust Fan.
Supply & fixing of over load relay ¾ legs /3 Phase contactor of starter of exhaust fan(from 2.0 to 7.5 amp)
Supply and fixing of 8 way consumer unit with 63 amp Isolator .(Havells,Anchor,Philips,Legrand,Bajaj,SSK).
Supply & fixing of box type plastic board with plastic top suitable for 01 switch and 01 socket (without switch and socket)
Supply & fixing of Box type plastic board with plastic top suitable for more than 01 switch and 01 socket (without switch and socket)
Supply & fixing/replacement of damaged 16-32 amp MCB(Havells,Anchor,Philips,Legrand ,Bajaj,SSK )
Day to day maintenance of single core double wire/single wire dressing of loose/dismantle/damage wiring by providing gully, clamps & clips etc.
Supply & replacement of 5/6 Amp, 250 V AC, switch /socket ( Havells,Anchor,Philips ,Bajaj,SSK )
Supply & replacement of 15/16 Amp,250 V AC switch /socket. (Havells,Anchor,Philips,SSK ,Bajaj )
Complete electrical wiring for making 5 amp point along with material like switch,socket,boards ,wires ,casing capingetc
Complete electrical wiring for making 15 amp point along with material like switch,socket,boards ,wires ,casing capingetc
Supply & replacement of SP&N enclosure, any std. ISI make with 2 pole and earth metal plug & socket for incorporating SP/DP MCB of 16/20 A. (Havells,Anchor,Philips,Legrand ,Bajaj,SSK )
Supply & fixing of MCB distribution board SPN (4 way /6way and without MCB) single door in place of worn out damaged MCB Box. (Havells,Anchor,Philips,Legrand ,Bajaj,SSK )
Supply and fixing of 8'X6" SS ENCLOSURE for fixing of T.B. and emergency push button at motors
Supply of any ISO make 1200 mm ceiling fan(Crompton/havells/usha/bajaj etc make) alongwith freight.
Supply of any ISO make exhaust fan 1400 rpm ,14/18 inch (Crompton/havells/usha/bajaj )etc make alongwith freight.
Dismantling of complete length of all 3 phase busbar& its insulators of turbine area EOT.(per section of 7 m)
Fixing of 3 phase Repaired busbar with insulators of turbine area EOT in 2x210 MW BTPS(per section of 7 m)
Supply of Insulators for connecting busbar
Miscellaneous material Nut bolt, washer, m-seal ,sealant etc
Repair of Gravity/ Rotary/ Limit switches
M/S SHYAM ERECTORS
M/S THERMAL INDIA
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .